ObjectiveTo evaluate the mid-term outcomes between tricuspid valve detachment (TVD) and non-detachment (NTVD) for ventricular septal defect (VSD).Methods The patients who underwent perimembranous VSD repair in the Department of Cardiovascular Surgery, West China Hospital from 2015 to 2020 were included. According to the surgical method, the patients were divided into a TVD group and a NTVD group. The clinical data of the two groups were compared.Results Totally 538 patients were included in the study. There were 240 patients in the TVD group, including 121 males and 119 females, with an average age of 3.85±8.42 years and an average weight of 14.12±12.97 kg. There were 298 patients in the NTVD group, including 149 males and 149 females, with an average age of 4.42±9.36 years and an average weight of 14.87±12.51 kg. There was no statistical difference in the age, weight, sex, preoperative New York Heart Association (NYHA) classification or tricuspid regurgitation (TR) degree between the two groups (P>0.05). Median follow-up was 30 (23, 40) months in the TVD group, and 29 (23, 41) months in the NTVD group (P=0.600). After operation, one patient in each group developed third-degree atrioventricular block and recovered to sinus rhythm before discharge (P=0.848). No pacemaker was needed. There was no statistical difference in the length of stay (P=0.054), mortality (P=1.000), in-hospital reoperation (P=0.199), or follow-up reoperation (P=0.505). More than 98% of patients in both groups had postoperative TR less than moderate (P=0.926). At the last follow-up, only 7 (2.9%) patients in the TVD group were detected trivial residual shunting, and 14 (4.7%) in the NTVD group (P=0.289). No one needed to have reoperation because of residual VSD. The TVD group showed less TR during the follow-up (P=0.019).Conclusion TVD is an alternative technique which can be safely used in the closure of VSD, especially in technologically mature medical center. Appropriate tricuspid valve detachment for those hard-to-expose VSDs does not result in poorer tricuspid valve function or higher risk of atrioventricular block, and might reduce the incidence of residual shunting.
One of its primary surgical treatments of tricuspid regurgitation is tricuspid valve biological valve replacement. Catheter tricuspid valve-in-valve implantation is a novel interventional alternative for biological valve failure. The non-invasive lung fluid measuring device remote dielectric sensing (ReDSTM) has been increasingly incorporated into clinical practice as a means of monitoring chronic heart failure in recent years. This report describes the process and outcomes of the first instance of perioperative lung fluid volume evaluation following transcatheter tricuspid valve implantation utilizing ReDSTM technology. The patient has a short-term, substantial increase in postoperative lung fluid volume as compared to baseline.
With the prevalence of atrial fibrillation and the increasing use of intracardiac pacemakers, the incidence of isolated tricuspid regurgitation is gradually increasing. Severe isolated tricuspid regurgitation has a seriously negative effect on the survival rate and life quality of patients. As the major invasive therapy, surgery is not routinely carried out due to high perioperative mortality. This article attempts to summarize the etiology, natural course and adverse consequences of isolated tricuspid regurgitation, current treatment strategies, surgical indications and techniques, efficacy evaluation, prognostic factors and transcatheter treatment progress of isolated tricuspid regurgitation, aiming to provide references for cardiologists and further researches.
ObjectiveTo explore the feasibility of goat tricuspid regurgitation (TR) model by one chordae tendineae cutter via right anterior-lateral minimal incision.MethodsTR model was established in 6 goats with a self-made tricuspid valve chordae tendineae cutter. The goats were placed in a left lateral position and procedure was performed via a right anterior-lateral minimal thoracotomy in the fourth intercostal. Under the guidance of transesophageal ultrasound and digital subtraction angiography, the chordae tendineae of anterior leaflet was cut until moderate to severe regurgitation was confirmed. Echocardiography and laboratory examinations were performed preoperatively, immediately and 3 months after surgery. Additionally, all goats were sacrificed to clarify pathological evaluation.ResultsTR was successfully established in 6 goats. The right atrium pressure increased significantly immediately after surgery (P<0.05). During a follow-up of 3 months, the progression of TR was aggravated (P<0.05), and the annular diameter increased from 2.15±0.23 cm to 2.65±0.20 cm. Overall, there was no statistically significant change in transvalvular gradient and velocity between preoperation and postoperation. Laboratory test results showed no abnormalities between preoperation and postoperation. Autopsy evaluation demonstrated obvioue chordae tendineae transection of the anterior leaflet.ConclusionIt is feasible to establish TR model via a right minimal anterior lateral thoracotomy in the fourth intercostal space. This novel TR goats model will allow investigation of transcatheter interventional device and serve as a chronic model in the future.
This article reports a case of transjugular transcatheter tricuspid valve replacement (TTVR) for persistent severe tricuspid regurgitation after transcatheter mitral valve replacement. The patient was an 80 year old female who underwent transcatheter mitral valve replacement at the Department of Cardiology, West China Hospital, Sichuan University, two months before admission. After the surgery, her condition worsened due to unimproved tricuspid regurgitation and right heart failure. After admission, the patient underwent transjugular TTVR under general anesthesia. With the assistance of cardiac ultrasound and X-ray fluoroscopy, an artificial valve was successfully implanted, and tricuspid regurgitation was relieved. The patient’s surgery went smoothly, and the condition improved significantly 25 days after surgery. The patient was discharged 34 days after surgery.
Tricuspid regurgitation (TR) affects a wide population in China, and frequently coexists with other conditions as comorbidities. Moderate to severe TR is associated with a poor prognosis and medical treatment alone does not prevent progression of disease. Although minimal invasive catheter-based techniques might be an option for TR treatment in selected high risk patients, there is no relevant recommendations for the transcatheter treatment of TR in practice guidelines. Several transcatheter edge-to-edge repair devices are currently in preclinical and early clinical evaluation as potential novel treatment options for symptomatic TR in patients at increased risk for surgery, becoming as the most common technique applied for interventional TR treatment. Hence, the present study will introduce the clinical features of TR, the progress of edge-to-edge repair, and the application and challenges in the future.
ObjectiveTo assess the method and the results of tricuspid annuloplasty performed(TVP) with the Edwards MC3 ring. MethodsWe retrospectively analyzed the clinical data of 312 patients with functional tricuspid regurgitation(FTR) secondary to left-sided valve disease in our hospital from June 2012 through May 2014. There were 147 males and 165 females at mean age of 55.7±7.3 years. ResultsThere was no death in the patients because of the planting of MC3 ring. The mean follow-up rate was 99.4%(310/312) for 2 patients immigration abroad. The follow-up time was 0-24(14.2±4.7) months. The ultrasoundcardiogram showed that all the ejection fraction(EF) of right ventricle improved compared with preoperation(P<0.05). The pulmonary artery systolic pressure(SPAP), both internal diameter and regurgitation volume of right ventricle were decreased(P<0.05). In the 310 patients, 302 patients(97.4%) were with the TR class 0-Ⅰ, 5 patients(1.6%) with class Ⅱ, 3 patients(1.0%) with class Ⅲ. There was no severe TR or no patient with reoperation. ConclusionThe MC3 ring is easy for planting and has good repeatability, which provides stable and satisfactory results for plasty of the tricuspid annulus with seldom residue or recurrent TR.
Objective To investigate the effects of different types of tricuspid regurgitation, implantation positions, and device models on the treatment outcomes of K-Clip for tricuspid regurgitation using numerical simulations. Methods Three-dimensional reconstruction of the heart model was performed based on CT images. Two different regurgitation orifices were obtained by modifying the standard parameterized tricuspid valve leaflets and chordae tendineae. The effects of different K-Clip models at different implantation positions (posterior leaflet midpoint, anterior-posterior commissure, anterior leaflet midpoint, posterior septal commissure) were simulated using commercial explicit dynamics software Ls-Dyna. Conclusion For the two types of regurgitation in this study, clipping at the posterior leaflet midpoint resulted in a better reduction of the regurgitation orifice (up to 75% reduction in area). Higher clamping forces were required for implantation at the anterior leaflet midpoint and posterior septal commissure, which was unfavorable for the smooth closure of the clipping components. There was no statistical difference in the treatment outcomes between the 18T and 16T K-Clip components, and the 16T component required less clamping force. Therefore, the use of the 16T K-Clip component is recommended.
Recently, several transcatheter devices for aortic valve replacement and mitral valve repair have been used in clinic, and researchers have designed a variety of tricuspid valve (TV) intervention devices. We reviewed the current status of transcatheter TV intervention, and focused on the structures of these devices and the early results of clinical trials. Undoubtedly, transcatheter intervention for TV is promising, innovational and safe for patients with severe TV regurgitation.
ObjectiveTo explore the clinical effect of LuX-Valve implantation in patients with severe tricuspid regurgitation (TR) and review articles about similar devices.MethodsWe reported the data of a 58-year-old male patient with severe TR, who was hospitalized on March 17th, 2020 because of “abdominal distention and edema for 5 years”, and then received LuX-Valve implantation in the Department of Cardiovascular Surgery of Changhai Hospital, Naval Medical University. Articles about transcatheter tricuspid valve replacement were reviewed in PubMed according to the key words including “transcatheter tricuspid valve replacement” “TTVR” and “transcatheter tricuspid valve intervention”.ResultsThe patient with severe TR received LuX-Valve implantation under general anesthesia and the guidance of digital subtraction angiography and transesophageal echocardiography. The patient’s TR was totally corrected after implantation and postoperative one-month follow-up showed well clinical effects. The result of literature review showed that there were two similar devices and both had been implanted in TR patients.ConclusionLuX-Valve is an effective and reliable transcatheter tricuspid valve replacement device.