ObjectiveTo evaluate the long-term clinical effect and risk factors of tricuspid valve replacement (TVR) as a relief treatment for adult patients with congenitally corrected transposition of the great artery (CCTGA).Method We retrospectively analyzed the clinical data of 47 adult patients with CCTGA who underwent tricuspid valve replacement in Fuwai Hospital between 2000 and 2017 year. There were 27 males and 20 females with operation age of 14–62 (38.8±13.5) years. Preoperative echocardiography showed moderate or more tricuspid regurgitation in all patients. The basic data of patients before and during operation were recorded. Survival was followed up by telephone and ultrasound report.ResultsThe average follow-up time was 6.5±3.7 years. The 1-year, 5-year and 10-year survival rate or the incidence of heart transplant-free was 94.6%, 90.5% and 61.7%, respectively. During the follow-up period, the long-term right ventricular ejection fraction of most patients (>90%) was still greater than or equal to 40%. Increased preoperative right ventricular end diastolic diameter (RVEDD) was a risk factor for death or heart transplantation (risk ratio 1∶11, P=0.04). The survival rate of patients with RVEDD (>60 mm) before operation was significantly reduced (P=0.032).ConclusionTVP is a feasible treatment for adult patients with CCTGA. The increase of preoperative RVEDD is a risk factor for long-term mortality.
ObjectiveTo investigate the indications and clinical effects of tricuspid cone reconstruction and tricuspid valve replacement in the treatment of downward displacement of tricuspid valve (Ebstein anomaly).MethodsThe clinical data of 22 patients with Ebstein anomaly who underwent surgical treatment in our hospital from January 2013 to March 2020 were collected. There were 7 males and 15 females, aged 4-56 (33.68±17.78) years. The patients were divided into two groups according to different surgical methods: a tricuspid cone reconstruction group (tricuspid valvuloplasty group, n=12) and a tricuspid valve replacement group (n=10). The curative effect of the two operative methods were compared.ResultsTwenty-two patients underwent surgical treatment under general anesthesia and cardiopulmonary bypass. One patient died of severe low cardiac output syndrome during operation. Downward displacement of tricuspid septum was found in 22 patients, and downward displacement of tricuspid septum and posterior septum in 21 patients, downward displacement of tricuspid in 8 patients. Twelve patients were treated with tricuspid valvuloplasty, 10 patients with tricuspid valve replacement, and patients with other intracardiac structural malformations were treated at the same time. Postoperative cardiac doppler ultrasound indicated no tricuspid regurgitation in 9 patients, mild regurgitation in 8 patients, and moderate regurgitation in 4 patients. No perivalvular leakage occurred in all patients undergoing valve replacement. Four patients developed degree Ⅲ atrioventricular block after operation, among whom 3 patients recovered to sinus rhythm and 1 patient implanted the permanent pacemaker. Twenty-one patients were cured and discharged after successful operation, and were followed up for 3 to 78 months, with a follow-up rate of 100.0%. During the follow-up period, there was no severe tricuspid regurgitation in tricuspid valvuloplasty group, but mild or moderate regurgitation was found. After tricuspid valve replacement, only 1 patient had mild regurgitation, and the rest patients had no valve regurgitation.ConclusionTricuspid valvuloplasty and tricuspid valve replacement are effective in the treatment of Ebstein anomaly, and the tricuspid regurgitation is less severe after tricuspid valve replacement operation. The operation method should be selected according to the different anatomical characteristics and condition of tricuspid valve. The combined intracardiac malformation or arrhythmia can be dealt with simultaneously.
ObjectiveTo explore the clinical effect of LuX-Valve implantation in patients with severe tricuspid regurgitation (TR) and review articles about similar devices.MethodsWe reported the data of a 58-year-old male patient with severe TR, who was hospitalized on March 17th, 2020 because of “abdominal distention and edema for 5 years”, and then received LuX-Valve implantation in the Department of Cardiovascular Surgery of Changhai Hospital, Naval Medical University. Articles about transcatheter tricuspid valve replacement were reviewed in PubMed according to the key words including “transcatheter tricuspid valve replacement” “TTVR” and “transcatheter tricuspid valve intervention”.ResultsThe patient with severe TR received LuX-Valve implantation under general anesthesia and the guidance of digital subtraction angiography and transesophageal echocardiography. The patient’s TR was totally corrected after implantation and postoperative one-month follow-up showed well clinical effects. The result of literature review showed that there were two similar devices and both had been implanted in TR patients.ConclusionLuX-Valve is an effective and reliable transcatheter tricuspid valve replacement device.
Objective To explore the evolving strategies and compare perioperative and long-term outcomes of tricuspid valve replacement (TVR) in recent 20 years in our hospital.MethodsBetween 1998 and 2018, the clinical data of 608 patients who underwent TVR at the Department of Cardiac Surgery, Guangdong Provincial People’s Hospital were retrospectively analyzed. There were 201 males and 407 females, with a median age of 47.0 (36.0, 57.0) years. Patients were divided into a biological tricuspid valve (BTV, n=427) group and a mechanical tricuspid valve (MTV, n=181) group. Propensity score matching was used to balance the baseline difference. Surgical strategy evolving, postoperative and long-term outcomes were analyzed between the two groups.ResultsSince 2008, the usage ratio of biological valves was significantly higher than that of mechanical valves. Seventy-nine (13.0%) patients died in hospital after TVR. Before propensity score matching, the postoperative mortality of the BTV group was higher than that of the MTV group (15.2% vs. 7.7%, P=0.012), and there was no statistical difference between the two groups after matching (10.4% vs. 7.2%, P=0.372). The duration of postoperative ventilator support in the BTV group was longer than that in the MTV group [22.0 (15.0, 37.0) h vs. 19.0 (11.0, 27.0) h, P=0.003], and the incidence of postoperative dialysis and re-thoracotomy exploring for bleeding was higher in the BTV group (8.9 % vs. 2.8%, 9.4% vs. 6.6%, respectively). However, there was no statistical difference in mortality after matching. The median follow-up time of discharged patients was 101.0 (65.0, 147.0) months, ranged from 1 to 265 months, and the follow-up rate was 82.2%. During the follow-up period, there were 101 deaths (19.1%) of whom 68 were from the BTV group and 33 from the MTV group. The survival rates at 1 year, 5 years, 10 years, 15 years and 20 years of all patients were 85.0% (95%CI 82.2-87.9), 78.9% (95%CI 75.7-82.4), 71.1% (95%CI 67.3-75.3), 59.7% (95%CI 54.2-65.6) and 51.7% (95%CI 43.3-60.7), and there was no statistical difference between the two groups after matching (P=0.46). The median time of tricuspid valve failure was 84.0 (54.0-111.0) months.ConclusionTVR is associated with high perioperative risks. There is no statistical difference in early mortality and long-term survival between biological and mechanical valve, while patients with mechanical valve has higher risk of re-operation for valve failure. Therefore, the type of prosthetic valve can be selected according to the patients' age, physical condition and the doctors’ experience.
ObjectiveTo analyze the Ebstein anomaly's reoperative strategy and mid- to long-term results.MethodsWe retrospectively reviewed the clinical data of 23 patients who diagnosed with Ebstein anomaly and underwent reoperation for tricuspid valve insufficiency between July 2002 and July 2017 in Fuwai Hospital. There were 9 (39.1%) males and 14 (60.9%) females, with a median age of 28.0 (19.0, 45.0) years.ResultsAmong the 23 patients, 8 (34.8%) underwent tricuspid valvuloplasty and 15 (65.2%) underwent tricuspid valve replacement. The rate of valvuloplasty was 16.7% before 2012, and 54.5% after 2012 (P=0.089) as Cone reconstruction procedure was used. In the valvuloplasty cohort, 3 (37.5%) patients were treated with Danielson or Carpentier technique, and 5 (62.5%) patients were treated with Cone reconstruction procedure. There was no operation-related death. Early complications occurred in 3 (37.5%) patients. The median follow-up was 6.9 years (range, 3.0-15.1 years), and no adverse cardiac events occurred. In the patients with valve replacement, 7 (46.7%) received mechanical prosthesis and 8 (53.3%) received bio-prosthesis. There was no operation-related death. And early complications were observed in 3 (20.0%) patients. The median follow-up was 6.5 years (range, 2.5-15.3 years). One (6.3%) patient died and 4 (26.7%) had long-term complications during the follow-up period.ConclusionThe mid- to long-term outcomes are convincing in patients who undergo the second operation due to recurrent tricuspid regurgitation of Ebstein anomaly. A low incidence of reoperation is observed. Cone reconstruction procedure provides possibilities of second tricuspid valvuloplasty, and this technique can reduce the rate of tricuspid valve replacement in the second operation. Tricuspid valve replacement is still an alternative method for the treatment of recurrent tricuspid regurgitation in patients with Ebstein anomaly. The bioprosthetic prosthesis may be a better choice than mechanical prosthesis.
ObjectiveTo analyze the clinical efficacy of transcatheter tricuspid valve replacement (TTVR) in cardiac implantable electronic lead-related tricuspid regurgitation (TR). MethodsThe patients with severe TR who underwent LuX-Valve TTVR in 9 Chinese medical centers from June 2020 to August 2021 were retrospectively enrolled. They were divided into a cardiac implantable electronic device (CIED) group and a non-CIED group based on whether they had pre-existing CIED implantation. Success of the procedure was defined as safe implantation of the LuX-Valve and complete withdrawal of the delivery system. Prognostic improvement was defined as a decrease of TR grade to≤2+ and an improvement of cardiac function by≥2 grades. Surgical success and postoperative prognosis were compared between the two groups. ResultsA total of 190 patients were collected, including 50 males and 140 females with a mean age of 66.2±7.8 years. There were 29 patients in the CIED group, and 161 patients in the non-CIED group. In the CIED group, 28 patients were implanted with a permanent pacemaker and 1 patient with a cardioverter-defibrillator. Preoperative New York Heart Association (NYHA) cardiac function class, TR degree, left ventricular ejection fraction, tricuspid annular plane systolic excusion, and cardiac risk scores were comparable between the two groups (P>0.05). Postoperative TR was reduced to≤2+ in all patients, and there was no statistical difference in the incidence of perivalvular leakage between the two groups (P=0.270). Postoperative CT of CIED patients showed the valve was in place, and the lead was not extruded, twisted, or deflected. The in-hospital mortality of the two groups were 10.3% and 1.9%, respectively, and the difference was statistically significant (P=0.047). In addition, there was no statistical difference between the two groups in terms of postoperative improvement of cardiac function and mortality in the 1- and 2-year follow-up. ConclusionTTVR is feasible, safe, and effective in patients with CIED implantation, and the pre-existing lead has no significant effect on the clinical efficacy.
Objective To analyze the medium-and long-term r esults of tricuspid valve replacement(TVR), to summarize the experience in opera tive therapy for tricuspid valve disease. Methods From January 1998 to May 2006, sixty seven patients had undergone TVR. The etiology was rheumatic disease in 25 cases, congenital disease in 37 cases, degenerative disease in 1 case, infective endocarditis in 3 cases, a nd cardiac tumor in 1 case. All operations were performed under general anesthes i a and by cardiopulmonary bypass. Bioprostheses was replaced in 28 patients, whil e mechanical valve was replaced in 39 patients. Associated procedure included mi tral valve replacement in 13 cases, mitral valve replacement and aortic valve replac ement in 12 cases, repair of ventricular septal defect in 1 case, repair of atri al septal defect in 1 case, and radioablation of atrial fibrillation in 3 case s. Results The operative mortality was 11.94% (8/67),among these patients , 6 cases died of serious heart failure,1 case died of ventricular fibrillation, 1 case died of multi organ failure. During follow-up, 1 patient died of biopro thesis dysfunction 1 year after the operation, 1 patient died of cerebral emboli s m 6 years after the operation. Through statistical analysis, it showed that the mortality of TVR in rheumatic tricuspid valve disease was higher than that in co ngenital tricuspid valve disease [5.56%(2/36)vs. 24.00% (6/25); χ2=4.425 , P=0.036]; the mortality in second time operation was higher than that in first time operation [30.00%(3/10)vs. 8.77% (5/57);χ2=3.646,P=0.033 ]; while there was no significant difference in immediate and long-term result s with different choice of bioprosthetic or mechanical valve in TVR (χ2=0.002 , P=0.961). Conclusion Operative an d follow-up mortality is high in the TVR, valve replac ement is the last selection for the treatment of serious tricuspid disease, appr opriate operative technique and perioperative therapy is the key for success o f the operation.
Objective To summarize the clinical characteristics and management experiences of patients with severe tricuspid regurgitation (TR) after mitral valve surgery. Methods Thirty patients were followed up and reviewed for this report. There were 1 male and 29 female patients whose ages ranged from 32 to 65 years (47.1±92 years). A total of 28 patients had atrial fibrillation and 2 patients were in sinus rhythm. There were 13 patients of mild TR, 10 patients of moderate TR and 7 patients of severe TR at the first mitral valve surgery. Five patients received the tricuspid annuloplasty of De Vega procedure at the same time, 2 patients received Kay procedure. The predominant presentation of patients included: abdominal discomfort (93.3%, 28/30), edema (66.7%,20/30), palpitation (56.7%, 17/30), and ascites (20%, 6/30). Results Nine patients underwent the secondary surgery for severe TR. The secondary surgery included tricuspid valve replacement (6 cases), mitral and tricuspid valve replacement (2 cases) and Kay procedure (1 case). Eight patients were recovered and discharged and 1 patient died from the bleeding of right atrial incision and low output syndrome. Twentyone patients received medical management and were followed up. One case was lost during followup. Conclusion Surgery or medical management should be based on the clinical characteristics of patients with severe TR after mitral valve surgery. It should be based on the features of tricuspid valve and the clinical experience of surgeon to perform tricuspid annuloplasty or replacement.