目的观察微创体外循环(minimal extracorporeal circulation,MECC)对主动脉瓣置换术临床效果的影响。 方法回顾性分析我院2010年3月至2012年10月共25例应用MECC方法行单纯主动脉瓣置换术(AVR)的临床资料,其中男15例、女10例,年龄40(19~58)岁。 结果总体外循环时间67(51~89)min、主动脉阻断时间42(33~63)min、转流中最低血红蛋白(Hb)9.6(8.3~12.6)g/dl、流转后Hb 9.5(7.7~12.6)g/dl,体外循环中无1例患者因Hb低而输入红细胞。所有患者均顺利拔除胸腔引流管,顺利出院,无院内死亡。 结论MECC系统应用于主动脉瓣置换安全可行,比传统心肺旁路系统具有更好的生物相容性和良好的临床结果,值得推广。
ObjectiveTo assess outcomes of transcatheter aortic valve replacement (TAVR) for pure native aortic valve regurgitation.MethodsA total of 129 patients underwent transfemoral TAVR in Fuwai Hospital from May 2019 to October 2020 were retrospectively analyzed. There were 83 males and 46 females with an average age of 72.26±8.97 years. The patients were divided into a pure native aortic valve regurgitation group (17 patients) and an aortic valve stenosis group (112 patients).ResultsThe incidence of valve in valve was higher in the pure native aortic valve regurgitation group (47.0% vs. 16.1%, P<0.01). There was no statistical difference between the two groups in conversion to surgery, intraoperative use of extracorporeal circulation, intraoperative left ventricular rupture, postoperative use of extracorporeal membrane oxygenation (ECMO), peripheral vascular complications, disabled stroke, death, or pacemaker implantation. There was no statistical difference in the diameter of annulus (25.75±2.21 mm vs. 24.70±2.90 mm, P=0.068) or diameter of outflow tract (25.82±3.75 mm vs. 25.37±3.92 mm, P=0.514) between the pure native aortic valve regurgitation group and the aortic valve stenosis group.ConclusionTransfemoral TAVR is a feasible method for patients with pure native aortic valve regurgitation. The diameter of annulus plane, the diameter of outflow tract and the shape of outflow tract should be evaluated.
Transcatheter aortic valve replacement is an effective treatment for aortic stenosis currently, especially in elderly, surgical high-risk, and surgical procedures-intolerant patients with severe aortic stenosis. After several generations of updates in design and function, the self-expandable valves have shown significant efficacy in treating aortic stenosis patients with bicuspid aortic valve, bioprosthetic valve failure or small annulus, and superiority in terms of valve durability, and the favorable hemodynamic outcomes could translate into clinical endpoint benefit. This literature review summarizes the advantages and recent advances of the self-expandable valves in transcatheter aortic valve replacement.
A 78-year-old female patient was admitted to West China Hospital of Sichuan University because of “amaurosis and polypnea for 4+ years”. The examination results before admission showed that severe stenosis of aortic valve, bicuspid aortic valve malformation, severe horizontal heart with 61.54° aortic angle. The preoperative evaluation of the patient indicated that the Society of Thoracic Surgeons score was 17.9%, which was high risk for surgery. After discussion by the heart team, the aortic stenosis was finally relieved by transcatheter aortic valve replacement. The operation was successfully completed by using the method of pulling and releasing the device with the same side basket. One month follow-up showed that the patient’s condition was stable and no complications occurred. This case aims to provide a reference for the treatment of horizontal heart with aortic stenosis. In the future, it is hoped that through continuous clinical practice, such patients will be provided with a safer and more efficient treatment plan.
Abstract: Objective To summarize the methods and results of supra-annular aortic valve replacement(AVR) in patients with severely damaged aortic annulus. Methods Supra-annular AVR was performed in 5 patients between March 2008 and Dec. 2010 in Changhai Hospital, Second Military Medical University. There were 4 males and 1 female with their mean age of 46.3 years (ranging from 38 to 53 years). Non-specific infectious diseases were diagnosed in 4 patients who had severe paravalvular leakage after their first AVR operations (2 patients with Behcet’s disease and 2 patients with arteritis), and one patient had severe infectious endocarditis. All the patients had severely destroyed aortic annulus and could not undergo routine AVR. The prosthetic valves were fixed to the aortic sinus wall between the annulus and coronary arterial ostia, and the sutures passed through from the outside of aortic wall into the inside and prosthetic valve ring. Coronary artery bypass grafting was performed if the coronary ostium was involved. Results All patients recovered from the operations uneventfully, and were followed up from 6 months to 3 years. All patients were in New York Heart Association(NYHA) functional class Ⅰ or Ⅱ during the follow-up period, and paravalvalar leakage, pseudoaneurysm and aortic root aneurysm were not found by the examination of 3D computed tomographic angiography and echocardiography at 6 months(4 cases), 1 year(2 cases), and 3 years(1 case), respectively . Conclusions Supra-annular AVR is an alternative surgical method for patients with severely damaged aortic annulus. The procedure is simple and effective to prevent paravalvular leakage and pseudoaneurysm formation.
Circulatory collapse is a common complication of transcatheter aortic valve replacement (TAVR), mainly due to new severe aortic regurgitation after balloon pre-dilation. This article reports the case of an 80-year-old female patient with severe aortic stenosis, who had a type 1 bicuspid aortic valve, with calcified aortic valve commissure between the right and left coronary cusps. During the procedure of TAVR, severe aortic regurgitation was caused by pre-dilation with 20 mm and 23 mm balloons. Then circulatory collapse and cardiogenic shock occurred. After the emergency deployment of the Venus A L26 valve, the cardiovascular hemodynamics was immediately improved. This case suggests that oversized balloon dilation should be avoided to prevent circulatory collapse caused by massive aortic regurgitation.
Transcatheter aortic valve replacement (TAVR) has become a common theraputic option for aortic stenosis, but the evidence for precise anatomy for TAVR is accumulating. This paper presents the case of an 71-year-old female patient who had an extremely high risk of coronary obstruction due to both coronary ostia lying too low. The patient underwent TAVR with the help of coronary protection successfully. During the procedure, the patient was protected with wires only for both coronaries. After deployment, angiofluoroscopy suggested that chimney stenting should be applied for left coronary. The whole procedure was unenventful and both coronaries were seen.
ObjectiveTo assess clinical results of aortic cusps replacement with bovine pericardium for bicuspid aortic valve (BAV) and severe aortic regurgitation (AR). MethodsClinical data of 79 patients with BAV and severe AR who underwent aortic cusps replacement with bovine pericardium in Wuhan Asia Heart Hospital from June 2008 to December 2013 were retrospectively analyzed. There were 60 male and 19 female patients with their age of 38±14 years (ranged 12-78 years). All the patients were in NYHA class Ⅱ. There were 26 patients with ascending aorta and sinotubular expanding. ResultsNo early death or major complication was recorded. Intraoperative transesophageal echocardiography showed successful repair with normal coaptation of the aortic leaflets in all the patients. AR grade was less than mild in all the patients with peak aortic valve pressure gradients of 14.2±2.8 mm Hg. All the patients were discharged from the hospital within 15 postoperative days without any adverse symptom, and were followed up for 50±16 months (ranged 9-64 months). During follow-up, all the patients were in NYHA classⅠ. There were 57 patients without AR, 16 patients with mild AR, 5 patients with moderate AR and 1 patients with severe AR. The peak of aortic valve pressure gradient was 12.4±3.2 mm Hg. The average diameter of ascending aorta was 2.7 cm in the patients with ascending aorta and sinotubular expanding. The shape of sinotubular kept normal. The height of coaptation of aortic valve was 0.58 cm by echocadiography. None of the patients died or required reoperation. The structural valve degeneration was not observed during the follow-up. ConclusionThree aortic cusps replacement with bovine pericardium can produce good hemodynamics and midterm results for patients with BAV and severe AR. The ascending aorta and sinotubular should be reduced and fixed in the patients with ascending aorta and sinotubular expanding.