west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "主动脉腔内修复术" 23 results
  • Technical points of external fenestration in the treatment of aortic dissection involved visceral branch arteries after EVAR

    Objective To summarize the advantages and key points of external fenestration in the treatment of aortic dissection involved visceral branch arteries after endovascular aortic repair (EVAR), and to explore the application effect of external fenestration in aortic dissection involved visceral branch arteries. Methods A patient with abdominal aortic aneurysm resulting in abdominal aortic dissection and involving multiple visceral arteries after EVAR was treated in Center of Vascular and Interventional Surgery, Department of General Surgery, The Third People’s Hospital of Chengdu. The surgical procedure of this patient was summarized, and the current status of total lumen technique in the treatment of such diseases was discussed and analyzed. Results The operation was successful, and it took only five hours, the intraoperative blood loss was about 100 mL, the patient was kept in ICU for one day and discharged one week after surgery and no serious postoperative complications occurred (such as spinal cord ischemia, liver and kidney insufficiency, infection, lower limb ischemia, puncture pseudoaneurysm, etc.). Aortic CT angiography was reexamined in three months after surgery, and the three-dimensional reconstruction showed that the aortic stent was stable, the blood flow of visceral branch arteries was smooth, and the aortic dissection was well isolated. Conclusion Endovascular repair of aortic dissection involving branch arteries of important organs can be achieved by external fenestration technique, it is a new treatment for aortic lesions involved visceral branch arteries.

    Release date:2022-12-22 09:56 Export PDF Favorites Scan
  • Thoracic Endovascular Aortic Repair for Stanford Type B Aortic Dissection

    ObjectiveTo evaluate clinical outcomes of thoracic endovascular aortic repair (TEVAR)for the treatment of Stanford type B aortic dissection (AD)and descending aortic aneurysm. MethodsClinical data of 20 patients with Stanford type B AD or descending aortic aneurysm who underwent TEVAR in West China Hospital from March to June 2013 were retrospectively analyzed. There were 19 male and 1 female patients with their age of 41-76 (58.3±10.2)years. Clinical outcomes were analyzed. ResultsAmong the 20 patients, 18 patients were successfully discharged, 1 patient refused further postoperative treatment and was discharged, and 1 patient died postoperatively. Sixteen patients (88.9%)were followed up for over 3 months. In all the patients during follow-up, true lumen diameter recovered within the scope of intravascular stents, and there was thrombosis in false lumen or aneurysm lumen. ConclusionTEVAR provides a new choice with significant advantages for the treatment of Stanford type B AD, especially for the elderly and patients with concomitant serious diseases, so it is worthy of clinical application.

    Release date: Export PDF Favorites Scan
  • "J. D" technique: A method for in situ fenestration of left subclavian artery in thoracic endovascular aortic repair

    ObjectiveTo report a simple and safe method for in situ fenestration of left subclavian artery in thoracic endovascular aortic repair (TEVAR).MethodsTwenty-eight patients received in situ fenestration of left subclavian artery in TEVAR from June 2018 to May 2019 in our center, including 23 males and 5 females at an average age of 57.7±9.6 years. Among them, 12 patients used adjustable sheath or guiding catheter (a group A) and 16 patients used "J. D"technique (a group B). The clinical efficacy of the two groups was compared.ResultsIn the group A, 1 patient failed to receive fenestration and was transferred to the chimney technique. In the group B, 1 patient due to the traction system shift during operation, was completed by traditional adjustable sheath puncture. The group B had shorter alignment-perforation time and trigger time and less complications. There was no significant difference in endoleak during short-term follow-up between the two groups.ConclusionThe "J. D" technique is simple, safe and easy to obtain materials. It effectively reduces the risk caused by difficult sheath alignment during the in situ fenestration of the left subclavian artery. Although the results of recent follow-up are not significantly different from traditional methods, it still needs to accumulate the cases to observe the possible risks and difficulties.

    Release date:2020-04-26 03:44 Export PDF Favorites Scan
  • Treatment choices of chronic thoracoabdominal aortic dissection aneurysm

    The treatment of chronic thoracoabdominal aortic dissection aneurysm remains a major challenge in aortic surgery. Open surgery is the mainstream treatment at present. New devices for endovascular treatment of chronic thoracoabdominal aortic dissection are gradually applied in clinical practice. The hybrid procedure is a combination of open and endovascular procedures. The appropriate treatment should be selected according to the patient's age, anatomy, genetic aortic disease, and comorbidities.

    Release date:2024-06-20 05:33 Export PDF Favorites Scan
  • Clinical effect of ascending aorta banding combined with typeⅠ hybrid aortic arch repair on aortic arch diseases

    Objective To assess the efficacy and safety of ascending aorta banding technique combined with typeⅠhybrid aortic arch repair for the aortic arch diseases. Methods The clinical data of patients undergoing ascending aorta banding technique combined with type Ⅰ hybrid arch repair for aortic arch diseases from March 2019 to March 2022 in Beijing Anzhen Hospital were retrospectively analyzed. The technical success, perioperative complications and follow-up results were evaluated. Results A total of 44 patients were collected, including 35 males and 9 females, with a median age of 63.0 (57.5, 64.6) years. The average EuroSCORE Ⅱ score was 8.4%±0.7%. The technical success rate was 100.0%. All patients did not have retrograde type A aortic dissection and endoleaks. One patient died of multiple organ failure 5 days after operation, the in-hospital mortality rate was 2.3%, and the remaining 43 patients survived and were discharged from hospital. The median follow-up period was 14.5 (6-42) months with a follow-up rate of 100.0%. One patient with spinal cord injury died 2 years after hospital discharge. One patient underwent thoracic endovascular aortic repair at postoperative 3 months due to new entry tears near to the distal end of the stent. Conclusion Ascending aorta banding combined with typeⅠhybrid arch repair for the aortic arch diseases does not need cardio-pulmonary bypass. Ascending aorta banding technique strengthens the proximal anchoring area of the stent to avoid risks such as retrograde type A dissection, endoleak and migration. The operation owns small trauma, rapid recovery, low mortality and a low rate of reintervention, which may be considered as a safe and effective choice in the treatment of the elderly, high-risk patients with complex complications.

    Release date:2024-09-20 12:30 Export PDF Favorites Scan
  • Advancements in the treatment of chronic thoracoabdominal aortic dissection

    Aortic dissection is a disease with high mortality rates. Due to the urgency of time, the diagnosis, treatment processes, and strategies of acute aortic dissection follow specific guidelines. However, patients with chronic aortic dissection are often neglected. Choosing the best medication therapy and surgical interventions remains challenging, and there is still a lack of guideline recommendations. With the improvement of imaging diagnostic methods for aortic diseases, the progress of endovascular surgical techniques, and the development of new endovascular graft devices in recent years, clinical data of the treatment of chronic aortic dissection is also gradually increasing. This article summarized the current new technologies and clinical research results for the diagnosis and treatment of chronic aortic dissection, aiming to provide new suggestions for the diagnosis and treatment of chronic aortic dissection.

    Release date:2024-06-20 05:33 Export PDF Favorites Scan
  • EFFECTIVENESS EVALUATION OF THORACIC ENDOVASCULAR AORTIC REPAIR FOR BLUNT THORACIC AORTIC INJURY WITH HOSTILE STENT-GRAFT PROXIMAL LANDING ZONE

    ObjectiveTo explore the effectiveness of thoracic endovascular aortic repair (TEVAR) for blunt thoracic aortic injury (BTAI) with hostile stent-graft proximal landing zone. MethodsA retrospective analysis was made on the clinical data of 13 patients with BTAI with hostile stent-graft proximal landing zone treated by TEVAR between December 2007 and December 2014. There were 10 males and 3 females with the mean age of 44 years (range, 24-64 years). The imaging examination indicated Stanford type B aortic dissection in 7 cases, pseudoaneurysm in 3 cases, aneurysm in 1 case, and penetrating ulcer in 2 cases. According to the partition method of thoracic aortic lesion by Mitchell, 8 cases underwent stent-graft with left subclavian artery (LSA) coverage, 3 underwent chimney stents for LSA, and 2 for left common carotid artery (LCCA). In 2 cases receiving chimney TEVAR involving LCCA, one underwent steel coils at the proximal segment of LSA to avoid type II endoleak and the other underwent in situ fenestration for endovascular reconstruction of LSA. ResultsAll TEVAR procedures were successfully performed. The mean operation time was 1.8 hours (range, 1-3 hours); the mean intraoperative blood loss was 120 mL (range, 30-200 mL); and the mean hospitalization time was 15 days (range, 7-37 days). No perioperative death and paraplegia occurred. The patients were followed up 3-30 months (mean, 18 months). Type I endoleak occurred in 1 case during operation and spontaneously healed within 6 months. Hematoma at brachial puncture site with median nerve compression symptoms occurred in 1 case at 3 weeks after operation; ultrasound examination showed brachial artery pseudoaneurysm and thrombosis, and satisfactory recovery was obtained after pseudoaneurysmectomy. No obvious chest pain, shortness of breath, left upper limbs weakness, numbness, and dizziness symptoms were observed. Imaging examination revealed that stentgraft and branched stent remained in stable condition. Meanwhile the blood flow was unobstructed. No lesions expanded and ruptured. No new death, bacterial infection, or other serious complications occurred. ConclusionAccording to Mitchell method, individualized plan may be the key to a promising result. More patients and further follow-up need to be included, studied, and observed.

    Release date: Export PDF Favorites Scan
  • Clinical efficacy of single branch stent-graft treatment for retrograde type A intramural hematoma: A retrospective cohort study

    ObjectiveTo explore the efficacy of using a single branch stent-graft to treat primary intramural hematoma located at the distal arch or descending aorta in Stanford A type aortic intramural hematoma. MethodsFrom July 2020 to November 2022, 10 patients with primary intramural hematoma of Stanford A type aortic intramural hematoma were treated with endovascular repair using a single branch stent-graft in the Department of Cardiovascular Surgery at The University of Hong Kong-Shenzhen Hospital. There were 9 males and 1 female, aged from 32 to 66 years, with a mean age of (47.0±10.4) years. All patients had intramural hematoma involving the ascending aorta and aortic arch, diagnosed as type A intramural hematoma, with the tear located in the descending aorta. Among them, 6 patients were complicated by ulceration of the descending aorta with intramural hematoma, and 4 patients had changes of the descending aortic dissection. All patients underwent endovascular stent repair, with 8 patients undergoing emergency surgery (≤14 days) and 2 patients undergoing subacute surgery (15 days to 3 months). Results There were no neurological complications, paraplegia, stent fracture or displacement, or limb or visceral ischemia during the perioperative period in all patients. One patient had continuous chest pain after surgery, and the stent had a new tear at the proximal end, requiring ascending aorta and partial arch replacement. As of the latest follow-up, all patients had obvious absorption or complete absorption of the intramural hematoma in the ascending aorta and aortic arch compared with before the operation. ConclusionSingle branch stent-graft treatment of retrograde ascending aortic intramural hematoma is safe and effective, with good short-term results.

    Release date:2025-07-23 03:13 Export PDF Favorites Scan
  • EFFECTIVENESS COMPARISON BETWEEN DOUBLE Perclose ProGlide CROSSING SUTURE AND TRADITIONAL SUTURE FOR CLOSURE OF PUNCTURE SITES IN ENDOVASCULAR AORTIC REPAIR

    Objective To compare the advantages and disadvantages between double Perclose ProGlide crossing suture and traditional suture for the closure of 20F or 22F access points so as to provide a basis for selecting appropriate approach to repair the puncture points in endovascular aortic repair. Methods Between June 2007 and May 2011, 103 patients (115 common femoral arteries) underwent endovascular aortic repair using sheaths of 20F or 22F (outer diameter); double Perclose ProGlide crossing suture was performed for closure of puncture sites in 57 cases (64 common femoral arteries) (double Perclose group) and traditional suture in 46 cases (51 common femoral arteries) (traditional group). There was no significant difference in age, gender, or disease duration between 2 groups (P gt; 0.05). Results The operation time, blood loss, and hospitalization days of double Perclose group were significantly better than those of traditional group (P lt; 0.05). Ecchymoma in inguinal region and lymphatic leakage occurred in 5 cases (5 common femoral arteries) and 2 cases (2 common femoral arteries) of double Perclose group respectively, in 2 cases (2 common femoral arteries) and 6 cases (8 common femoral arteries) of traditional group respectively; no significant difference was found in the rate of the early complication between double Perclose group and traditional group (7.8% vs. 15.7%, χ2=1.76, P=0.19). The technique success rate of double Perclose group was 96.9% (62/64), and was 100% (51/51) in traditional group, showing no significant difference (χ2=0.31, P=0.50). All patients were followed up, 2-19 months (mean, 15 months) in double Perclose group and 2-18 months (mean, 14 months) in traditional group. Pseudoaneurysm occurred in the puncture region at 3 months in 1 case (1 common femoral artery) of double Perclose group, and incision and suture therapy was performed; no arteriostenosis or pseudoaneurysm occurred in other cases; and the rate of mid-term complication was 1.6% (1/64) in double Perclose group and was 0 in traditional group, showing no significant difference (P=1.000). Conclusion Double Perclose ProGlide crossing suture has the same effectiveness to traditional surture in repairing the puncture point with 20F or 22F, but it is superior to traditional suture in reducing operation time, blood loss, and hospitalization days.

    Release date:2016-08-31 04:24 Export PDF Favorites Scan
  • Effectiveness and predictive value of computer finite element modeling of thoracic endovascular aortic repair based on hemodynamics

    Objective To explore the effectiveness and predictive value of computer simulated thoracic endovascular aortic repair (TEVAR). Methods The clinical data of the patients with Stanford type B aortic dissection who underwent TEVAR from February 2019 to February 2022 in our hospital was collected. According to whether there was residual false cavity around the stent about 1 week after TEVAR, the patients were divided into a false cavity closure group and a false cavity residual group. Based on computer simulation, personalized design and three-dimensional construction of the stent framework and covering were carried out. After the stent framework and membrane were assembled, they were pressed and placed into the reconstructed aortic dissection model. TEVAR computer simulation was performed, and the simulation results were analyzed for hemodynamics to obtain the maximum blood flow velocity and maximum wall shear stress at the false lumen outlet level at the peak systolic velocity of the ventricle, which were compared with the real hemodynamic data of the patient after TEVAR surgery. The impact of hemodynamics on the residual false lumen around the stent in the near future based on computer simulation of hemodynamic data after TEVAR surgery was further explored. Results Finally a total of 28 patients were collected, including 24 males and 4 females aged 53.390±11.020 years. There were 18 patients in the false cavity closure group, and 10 patients in the false cavity residual group. The error rate of shear stress of the distal decompression port of the false cavity after computer simulation TEVAR was 6%-25%, and the error rate of blood flow velocity was 3%-31%. There was no statistical difference in age, proportion of male, history of hypertension, history of diabetes, smoking history, prothrombin time or activated partial thromboplatin time at admission between the two groups (all P>0.05). The blood flow velocity and shear stress after TEVAR were statistically significant (all P<0.05). The maximum shear stress (OR=1.823, P=0.010) of the false cavity at the level of the distal decompression port after simulated TEVAR was an independent risk factor for the residual false cavity around the stent. Receiver operating characteristic curve analysis showed that the area under the curve corresponding to the maximum shear stress of false cavity at the level of distal decompression port after simulated TEVAR was 0.872, the best cross-sectional value was 8.469 Pa, and the sensitivity and specificity were 90.0% and 83.3%, respectively. Conclusion Computers can effectively simulate TEVAR and perform hemodynamic analysis before and after TEVAR surgery through simulation. Maximum shear stress at the decompression port of the distal end of the false cavity is an independent risk factor for the residual false cavity around the stent. When it is greater than 8.469 Pa, the probability of residual false cavity around the stent increases greatly.

    Release date:2024-01-04 03:39 Export PDF Favorites Scan
3 pages Previous 1 2 3 Next

Format

Content