Objective To explore the effect of minimally invasive and mini-incision surgery (MIS) in total hip arthroplasty (THA) on late osteonecrosis of femoral head (ONFH). Methods From March 2003, Eighteen patients (22 hips) with ONFH underwent MIS in THA. Their ages ranged from 24to 57 years, including 13 males and 5 females. The mean body mass index ranged from 17.1 to 30.1(24.6 on average). The Harris hip score was 46 points before operation. Modified posterior-lateral approach was adopted, and the MIS THA was performed by cementless prosthesis. As a comparison, 18 patients (22 hips) were performed by conventional THA at the same period. The data, including bleeding volume during operation, incision length, operative time, and postoperative function recovery, were compared. Results Follow-ups were done for 6 to 20 months (11 months on average). Dislocation occurred in one patient that underwent conventional THA 2 days after operation. No complication occurred in MIS THA group. The incision lengths ranged from 8.7 to 10.5 cm (9.3 cm on average) in MIS THA group, being statistically different (Plt;0.01). There was no significant difference in Harris scoring of the function between the two groups both before the operation and after the operation (Pgt;0.05). The operative time was almost the same, but the bleeding volume in MIS THA group was less (Plt;0.05). The function recovery was faster in MIS THA group.Conclusion The MIS THA is an alternative to the treatment of late ONFH. The advantages of MIS THA are fewer trauma, less bleeding volume, and faster recovery. The MIS THA should be performed by surgeons with rich experiences in THA and hospitals with necessary instruments.
Objective To evaluate the therapeutic outcome of artificial total hip arthroplasty (THA) with collum femoris preserving for hip joint desease in young and middle-aged patients. Methods From March 2002 to March 2005, 26 cases (31 hips) of hip joint disease were treated with artificial THA with collum femoris preserving, including 19 males (23 hips)and 7 females (8 hips) and aged 32-48 years with an average of 37 years. In 31 hips, 17 left hips and 14 right hips were involved. There were 9 cases of osteoarthritis of the hip joint caused by avascular necrosis of the femoral head (ANFH), 7 cases of ANFH, 3 cases of femoral head necrosis caused by dysplasia of acetabular, 1 case of osteoarthritis of the hip joint caused by ankylosing spondyl itis, and 2 cases of rheumatoid arthritis; the course of disease was 2-11 years (5.6 years on average). Two cases of femoral neck fracture (Garden IV), and 2 cases of non-union femoral neck fractures (1 for Garden III and 1 for Garden IV), the course of disease was 5 days, 24 months, and 26 months. The prime symptoms were pain, difficult walk and l imp. All patients were taken X-ray to exclude osteoporosis. Results The right distal femur prosthesis of a bilateral patient cracked owing to excessive amputation of collum femoris, and fracture healed after symptomatic treatment. All the incisions healed by first intention and no compl ications occurred. All patients were followed up for 4-7 years, with an average of 5.6 years. One case had poor hip function because he did not follow rehabil itation procedure, and the others achieved good outcome with normal gait. One case complained of persistent pain 6 months after operation, and was rel ieved by administration of some non-steroidal antiinflammatory drugs and anti-osteoporosis drugs 6 months later. The X-ray films after operation and at last follow up showed good location of prosthesis and no bone resorption. Harris score at last follow-up was 91.31 ± 0.77, and it was significantly higher than that before operation (50.88 ± 0.90), (P lt; 0.05). The excellent and good rate was 93.5% (excellent in 11 hips, good in 18 hips, and fair in 2 hips). Conclusion Artificial THA with collum femoris preserving can retain more bone, be easier for revision, and has an excellent outcome.
ObjectiveTo evaluate the accuracy of using smartphone to measure the angle of acetabular component in total hip arthroplasty (THA). MethodsBetween June 2012 and September 2015, the acetabular abduction and anteversion angles were measured in 50 patients undergoing THA. There were 24 males and 26 females, aged 37 to 83 years (mean, 71 years). The left hip was involved in 22 cases and the right hip in 28 cases. Of 50 patients, 34 suffered from fracture of the femoral neck, and 16 suffered from avascular necrosis of the femoral head. Acetabular dysplasia was excluded in all cases. A smartphone was used to measure the acetabular abduction and anteversion angles during operation; standard Picture Archiving and Communication Systems (PACS) was used to measured the acetabular abduction and anteversion angles on the X-ray film at 1 week after operation. It was defined as positive that the component angle values by PACS measurement were greater than those by the smartphone measurement, whereas as negative. The two measurement methods were compared, and intra-observer variability was assessed by analyzing the intraclass correlation coefficient (ICC), the Mann-Whitney U-test was used to analyze difference. ResultsThe ICC was 0.84 in the acetabular component angles by smartphone and PACS measurement methods. The acetabular component abduction angle was (44.02±1.33)° and the anteversion angle was (17.62±2.20)° by smartphone measurement. The acetabular component abduction angle was (44.74±4.05)° and the anteversion angle was (17.22±5.57)° by PACS measurement. There was no significant difference between two measurement methods (Z=-1.977, P=0.482; Z=-0.368, P=0.713). The acetabular component angle was in the safe zone in 44 cases; and the acetabular component anteversion angle was beyond safe range of 1 to 5°, and the abduction angle was beyond safe range of 1 to 3° in 6 cases. Intra-measurement variability was -21 to +10° for the anteversion angle and -10 to + 9° for the abduction angle, indicating that the acetabular component anteversion angle by smartphone measurement was greater than that by the PACS measurement, and the abduction angle was less than that by PACS measurement. ConclusionSmartphone is a convenient tool to measure the acetabular component angle in THA.
Objective Using the mono-energy reconstruction images and X-ray films to investigate whether the ABG Ⅱ short-stem could improve the filling ratio, stability, and alignment in the Dorr type C femur, compared with the Corail long-stem. MethodsAmong patients who were with Dorr type C femurs and treated with total hip arthroplasty between January 2006 and March 2012, 20 patients with a Corail long-stem (Corail group) and 20 patients with an ABG Ⅱ short-stem (ABG Ⅱ group) were randomly selected. The differences in gender, age, body mass index, and preoperative diagnoses between the two groups were not significant (P>0.05). The ABG Ⅱ group was with a mean follow-up of 142 months (range, 102-156 months), and the Corail group was with a mean follow-up of 107 months (range, 91-127 months). There was no significant difference in the Harris score and subjective satisfaction score between the two groups at last follow-up (P>0.05). At last follow-up, dual-energy CT scans with mono-energy image reconstruction were used to calculate the prosthetic filling ratio and to measure the alignment of the prosthesis in the coronal and sagittal positions. Stability assessment was performed based on X-ray films, and the subsidence distance was measured using EBRA-FCA software. ResultsX-ray film observation showed that the prostheses in the two groups were stable and no signs of loosening was found. The incidence of pedestal sign was significantly lower in the ABGⅡ group than in the Corail group (P<0.05), and the incidence of heterotopic ossification was significantly higher in the ABGⅡ group than in the Corail group (P<0.05). The subsidence distance of femoral stem in ABG Ⅱ group was significantly greater than that in Corail group (P<0.05), and the subsidence speed of femoral stem in ABG Ⅱ group was also greater than that in Corail group, but the difference was not significant (P>0.05). The overall prosthesis filling ratio was significantly higher in the ABG Ⅱ group than in the Corail group (P<0.05), while the coronal filling ratio at the lesser trochanter, 2 cm below the lesser trochanter, and 7 cm below the lesser trochanter were not significant (P>0.05). The results of prosthesis alignment showed that there was no significant difference in the sagittal alignment error value and the incidence of coronal and sagittal alignment error >3° between the two groups (P>0.05), while the coronal alignment error value in the ABG Ⅱ group was significantly greater than that in the Corail group (P<0.05). Conclusion Although the ABG Ⅱ short-stem avoids the distal-proximal mismatch of the Corail long-stem in the Dorr type C femur and thus achieves a higher filling ratio, it does not appear to achieve better alignment or stability.
【Abstract】 Objective To investigate the method to avoid lengthening lower limbs after total hip arthroplasty in patients with congenital short femoral neck. Methods The clinical data were analyzed retrospectively from 38 patients undergoing unilateral total hip arthroplasty between April 2005 and December 2010. There were 26 males and 12 females, aged 45-78 years (mean, 62.3 years). Among these cases, there were 11 cases of avascular necrosis of the femoral head, 17 cases of hip osteoarthritis, and 10 cases of femoral neck fracture. Before operation, 29 cases had leg length discrepancy; and the shortened length of the legs was 10-24 mm with an average of 14.5 mm by clinical measurement, and was 11-25 mm with an average of 14.7 mm by X-ray film measurement. The Harris score before operation was 44.0 ± 3.6. Results At 1 day after operation, 3 cases had legs lengthening by clinical and X-ray film measurement; limb length difference less than 10 mm was regarded as equal limb length in the other 35 patients (92.1%). All incisions healed by first intention, and no complication of infection or lower limb deep venous thrombosis occurred. In 3 patients who had legs lengthening, 1 patient had abnormal gait and slight limping after increasing heel pad because the lower limb was lengthened by 16 mm, and 2 patients had slight limping. The other patients could walk normally and achieved pain relief of hip. Thirty-six patients were followed up 12-68 months (mean, 43.8 months). The Harris score was 86.7 ± 2.3 after 6 months, showing significant difference (t=3.260, P=0.031) when compared with that before operation. The X-ray films showed no prosthetic loosening or subsidence. Conclusion For patients with congenital short femoral neck during total hip arthroplasty, the surgeons should pay attention to osteotomy plane determination, limb length measurement, and use of the prosthesis with collar to avoid the lengthening lower limbs
ObjectiveTo retrospectively compare the mid-term effectiveness between by direct anterior approach (DAA) and by posterolateral approach in total hip arthroplasty (THA).MethodsBetween January 2009 and December 2010, 110 patients (110 hips) treated with THA and followed up more than 5 years were chosen in the study. THA was performed on 55 patients by DAA (DAA group), and on 55 patients by posterolateral approach (PL group). There was no significant difference in gender, age, body mass index, types of hip joint disease, and preoperative Harris score between 2 groups (P>0.05). The operation time, amount of bleeding, length of hospital stay, postoperative complications, and the Harris scores were recorded and compared.ResultsThere was no significant difference in operation time and length of hospital stay between 2 groups (t=0.145, P=0.876; t=1.305, P=0.093). The amount of bleeding was significantly less in DAA group than in PL group (t=2.314, P=0.032). All patients were followed up 5-7 years (mean, 5.97 years). Complications happened in 5 cases (9.1%) of DAA group and in 3 cases (5.5%) of PL group, and there was no significant difference in the incidence of complications between 2 groups (χ2=0.539, P=0.463). There was significant difference in Harris scores at 6 months after operation between 2 groups (t=2.296, P=0.014), but no significant difference was found in Harris score at 1 year and 5 years between 2 groups (t=1.375, P=0.130; t=0.905, P=0.087). Further analysis, at 6 months after operation, the joint function score in DAA group was significantly higher than that in PL group (t=1.087, P=0.034), while there was no significant difference in the pain score and range of motion score between 2 groups (t=1.872, P=0.760; t=1.059, P=0.091).ConclusionTHA by DAA has the advantages of less bleeding and faster recovery. The short-term effectiveness is superior to the THA by traditional posterolateral approach, but there is no obvious advantage in the mid-term effectiveness.
Objective To explore the effective method and the feasibil ity of the accurate l imb length equal ization in patients undergoing total hip arthroplasty (THA). Methods From September 2006 to September 2008, 52 patients underwentunilateral THA, including 36 males and 16 females, with an average age of 61.5 years (range, 46-76 years). Among these cases, there were 22 cases of avascular necrosis of the femoral head, 12 cases of hip osteoarthritis, 11 cases of femoral neck fracture, 4 cases of congenital dislocation of hip, and 3 cases of acetabular dysplasia. Forty cases had leg length discrepancy, and the shortened length of the legs was in the range of 10 mm to 35 mm with an average of 20 mm. The mean Harris score before operation was 45 points (range, 36-58 points). Based on the cl inical measurement and radiographic examination, the surgical protocols were designed, the type of the hip prosthesis was chosen, and the neck length of the femoral prosthesis, and the position of osteotomy were estimated. By the proper wearing of the acetabula, the best rotation point was found out. The cut plane of the femoral neck was adjusted according to the results of the radiographic and other examinations. The neck length was readjusted after the insertion of the prosthesis so as to achieve intended leg-length equal ization. The discrepancy of the leg length was measured and evaluated after operation. Results The incision healed by first intention in all patients. One patient had ischiadic nerve palsy and achieved full restoration after 5 months of symptomatic management. Forty-four patients were followed up 16 months on average (7-32 months). The mean Harris score was 87.5 points (80-91 points), showing significant difference (P lt; 0.05) whencompared with that before operation. The l imb length equal ization were got in 35 patients (equal ization rate was 79.5%). Seven patients had the prolong leg (from 10 mm to 18 mm), 2 patients had the shortened legs (15 mm and 25 mm, respectively). Conclusion By measurement of leg-length and radiographic examination before and during operation, the problem of unequal leg - length can be solved during the THA.
Objective To discuss the short-term effectiveness of total hip arthroplasty (THA) for post-traumatic osteoarthritis secondary to acetabular fracture. Methods Between January 2004 and March 2012, the clinical data was analyzed retrospectively from 12 cases (13 hips) of post-traumatic osteoarthritis secondary to acetabular fracture undergoing THA. Of 12 patients, 6 were male and 6 were female, with an average age of 55.6 years (range, 40-68 years). The locations were the left hip in 5 cases, the right hip in 6 cases, and bilateral hips in 1 case. The interval between acetabular fracture and THA was 65.7 months on average (range, 12-240 months). The preoperative hip Harris score was 48.8 ± 9.5. Results The incisions healed by first intention. No deep vein thrombosis and infection occurred postoperatively. Ten cases were followed up 1-7 years (mean, 4.8 years). The hip Harris score was 86.5 ± 8.6 at last follow-up, showing significant difference when compared with preoperative score (t=10.520, P=0.006). X-ray films showed no acetabular prosthesis instability. Stem subsidence (2 mm) occurred in 1 case, peri-prosthetic osteolysis in 2 cases, and heterotopic ossification in 2 cases (Brooker type I and type II in 1 case, respectively). Conclusion THA has satisfactory short-term effectiveness for post-traumatic osteoarthritis secondary to acetabular fracture. The good effectiveness is based on strict case selection, pathological evaluation, and the proper acetabular reconstruction.
目的:加深和提高对股骨头缺血坏死影像学诊断的认识,并对人工全髋关节置换术前、术后的影像学价值进行评估。方法:回顾性分析58例作全髋关节置换术患者的术前股骨头缺血坏死的X线(DR)、CT和MRI影像学改变特征,并对人工全髋关节置换术后X线(DR)片进行评估。 结果:58例患者,术前采用X线、CT及MRI诊断股骨头缺血坏死累计80个股骨头。其中64个股骨头行人工全髋置换 (6名患者为双侧),12个股骨头行钻孔减压植骨术,4个股骨头为非手术治疗。行人工全髋关节置换64个中,术后证实股骨头缺血坏死42个,髋关节发育不良继发骨关节病20个,创伤性骨关节炎2个。结论:股骨头缺血坏死中晚期患者,X线(DR)检查简便易行,结合CT、MRI检查,诊断准确率很高;人工全髋置换术是目前治疗晚期股骨头缺血坏死的最好选择。