west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "克氏针" 42 results
  • A BIOMECHANICAL STUDY ON INTERNAL FIXATION OF PROXIMAL ULNA COMBINED WITH OLECRANON FRACTURE

    Objective To compare the biomechanical stability of Kirschner wire and tension band wiring, reconstruction plate combined with tension band wiring, and olecranon anatomical plate in fixing proximal ulna combined with olecranon fracture, so as to provide the theoretical evidence for clinical selection of internal fixation. Methods Eight specimens of elbow joints and ligaments were taken from eight fresh male adult cadaveric elbows (aged 26-43 years, mean 34.8 years) donated voluntarily. The model of proximal ulna combined with olecranon fracture was made by an osteotomy in each specimen. Fracture end was fixed successively by Kirschner wire and tension band wiring (group A), reconstruction plate combined with tension band wiring (group B), and olecranon anatomical plate (group C), respectively. The biomechanical test was performed for monopodium compression experiments, and load-displacement curves were obtained. The stability of the fixation was evaluated according to the load value when the compression displacement of fracture segment was 2 mm. Results No Kirschner wire withdrawal, broken plate and screw, loosening and specimens destruction were observed. The load-displacement curves of 3 groups showed that the displacement increased gradually with increasing load, while the curve slope of groups B and C was significantly higher than that of group A. When the compression displacement was 2 mm, the load values of groups A, B, and C were (218.6 ± 66.9), (560.3 ± 116.1), and (577.2 ± 137.6) N, respectively; the load values of groups B and C were significantly higher than that of group A (P lt; 0.05), but no significant difference was observed between groups B and C (t=0.305, P=0.763). Conclusion The proximal ulna combined with olecranon fracture is unstable. Reconstruction plate combined with tension band wiring and olecranon anatomical plate can meet the requirement of fracture fixation, so they are favorable options for proximal ulna combined with olecranon fracture. Kirschner wire and tension band wiring is not a stable fixation, therefore, it should not be only used for proximal ulna combined with olecranon fracture.

    Release date:2016-08-31 04:21 Export PDF Favorites Scan
  • Effectiveness of Kirschner wire fixation and coracoclavicular ligament reconstruction with suture anchor in treatment of Cho type ⅡC distal clavicle fractures

    Objective To evaluate the effectiveness of Kirschner wire fixation and coracoclavicular ligament reconstruction with suture anchor in the treatment of Cho type ⅡC distal clavicle fractures. Methods The data of 17 patients with Cho type ⅡC distal clavicular fractures, who were treated with Kirschner wire fixation and coracoclavicular ligament reconstruction with suture anchor between June 2019 and June 2021, was retrospectively analyzed. There were 11 males and 6 females with an average age of 38.7 years (range, 19-72 years). The fractures were caused by falling in 12 cases and traffic accident in 5 cases. All patients had fresh closed fractures. The interval from injury to operation was 1-5 days (mean, 2.6 days). The preoperative injury severity score (ISS) was 6-27 (mean, 10.2). The operation time, intraoperative blood loss, hospital stay, fracture healing, and postoperative complications were analyzed. The shoulder joint function was evaluated by disabilities of the arm, shoulder, and hand (DASH) score and Constant score at last follow-up. Results All operations were completed successfully. The operation time was 20-50 minutes (mean, 31.6 minutes). The intraoperative blood loss was 30-100 mL (mean, 50.6 mL). The hospital stay was 4-9 days (mean, 5.3 days). All incisions healed by first intention. All patients were followed up 12-16 months (mean, 13 months). All clavicle fractures healed, and the healing time was 8-15 weeks (mean, 11 weeks). No complications such as fracture displacement or nonunion caused by internal fixation failure occurred. During the follow-up, skin irritation caused by the Kirschner wire withdrawal occurred in 3 cases. The Kirschner wires were removed after fracture healing in 17 patients. At last follow-up, the Constant score of shoulder joint was 90-100 (mean, 98.2). The DASH score was 0-10 (mean, 1.5). ConclusionKirschner wire fixation combined with coracoclavicular ligament reconstruction with suture anchor in the treatment of Cho type ⅡC distal clavicle fractures has less postoperative complications and slight complications. It is convenient to remove the internal fixator. The Kirschner wire does not fix the distal clavicle fracture through the acromion, which has little effect on shoulder joint function and can obtain good effectiveness.

    Release date:2023-12-12 05:05 Export PDF Favorites Scan
  • Effectiveness comparison of suspension fixation plus hinged external fixator and double plate internal fixation in treatment of type C humeral intercondylar fractures

    Objective To compare the effectiveness of suspension fixation plus hinged external fixator with double plate internal fixation in the treatment of type C humeral intercondylar fractures. Methods Between January 2014 and April 2016, 30 patients with type C (Association for the Study of Internal Fixation, AO/ASIF) humeral intercondylar fractures were treated. Kirschner wire suspension fixation plus hinged external fixator was used in 14 cases (group A), and double plate internal fixation in 16 cases (group B). There was no significant difference in gender, age, injury cause, disease duration, injury side, and type of fracture between 2 groups (P>0.05). Results There was no significant difference in operation time and hospitalization stay between 2 groups (P>0.05). But the intraoperative blood loss in group A was significantly less than that in group B (P<0.05); the visual analogue scale (VAS) score at 1 day and 3 days after operation in group A were significantly less than those in group B (P<0.05). Primary healing of incision was obtained in all patients of 2 groups, and no surgery-related complications occurred. The patients were followed up 6-24 months (mean, 12.3 months) in group A and 6-24 months (mean, 12.8 months) in group B. The self-evaluation satisfaction rate was 85.7% (12/14) in group A and was 81.2% (13/16) in group B at 3 months after operation, showing no significant difference (χ2=0.055, P=0.990). Based on the improved Gassebaum elbow performance score at 6 months after operation, excellent and good rate of the elbow function was 78.6% (excellent in 5 cases, good in 6 cases, fair in 2 cases, and poor in 1 case) in group A and was 81.2% (excellent in 6 cases, good in 7 cases, fair in 2 cases, and poor in 1 case) in group B, showing no significant difference between 2 groups (χ2=0.056, P=0.990). Heterotopic ossification occurred at 3 months after operation in 1 case of each group respectively. The X-ray films showed bony union in all cases; no loosening or breakage of screw was observed. The bone union time showed no significant difference between 2 groups (t=–0.028, P=0.978). The time of internal fixation removal, the intraoperative blood loss, and VAS score at 1 day and 3 days after operation in group A were significant better than those in group B (P<0.05). Conclusion The suspension fixation plus hinged external fixator and double plate internal fixation for the treatment of type C humeral intercondylar fractures have ideal outcome in elbow function. But the suspension fixation plus hinged external fixator is better than double plate internal fixation in intraoperative blood loss, postoperative VAS score, and time of internal fixation removal.

    Release date:2017-07-13 11:11 Export PDF Favorites Scan
  • REPAIR OF MASON TYPE-II RADIAL HEAD OR NECK FRACTURES IN CHILDREN

    Objective To investigate the curative effects of open reduction and internal fixation with Kirschner wire for Mason type-II radial head or neck fracture in children. Methods From September 2007 to June 2009, 17 cases of Mason type-II radial head or neck fracture were treated, including 11 males and 6 femals with an average age of 8.5 years (4-11 years).The locations were left side in 5 cases and right side in 12 cases. All fractures were caused by fall ing and classified as Mason type- II fracture. Two cases compl icated by radial nerve deep branch injury. The time from injury to operation was 4 hours to 5 days. All cases received open reduction and internal fixation with Kirschner wire. They were evaluated by anteroposterior and lateral radiographs and functionally by Broberg criteria. Results Wound healed primarily in all patients. According to Métaizeau criteria, the results were excellent in 15 patients and good in 2 patients, who achieved anatomical reduction. Seventeen patients were followed up for a mean time of 14 months (6-25 months). Function returned to normal in 2 cases compl icated by radial nerve deep branch injury after 6 months of operation. No compl ications of infection and nerve injury occurred. The X-ray films showed that bony heal ing was achieved in all cases; the heall ing time was 2.0-3.5 months (mean 3 months). According to Broberg criteria, the outcome was excellent in 11 cases, good in 4 cases, and fair in 2 cases, the excellent and good rate was 88.2%. Conclusion Open reduction and internal fixation with Kirschner wire has good effect, satisfactory functional recovery and less compl ication in the treatment of Mason type-II fracture of radial head or neck in children.

    Release date:2016-08-31 05:47 Export PDF Favorites Scan
  • Long-term Clinical and Radiological Outcomes of Kirschner Tension Band Fixation versus Clavicular Hook Plate for RockwoodⅢ Acromioclavicular Joint Dislocation

    目的 比较克氏针张力带与锁骨钩钢板治疗RockwoodⅢ型肩锁关节脱位的临床疗效。 方法 1999年1月-2007年3月,收治肩锁关节脱位患者29例,分别采用克氏针张力带联合喙锁韧带重建(克氏针组10例)和锁骨钩钢板(钢板组19例)治疗。其中男18例,女11例;年龄19~50岁,平均38.2岁。患者均为新鲜RockwoodⅢ型肩锁关节脱位,受伤至手术时间1~16 d,平均3 d。两组患者性别、年龄、受伤至手术时间等一般资料比较差异无统计学意义(P>0.05)。进行两组患者术后临床及影像学评估比较。 结果 25例患者(克氏针组10例,钢板组15例)获随访,随访时间2~12年,平均6年。术后克氏针组发生克氏针弯曲5例、断裂1例;钢板组切口浅表感染2例,经换药后治愈,其余患者切口Ⅰ期愈合。两组患者肩锁关节均获得良好功能,组间比较差异无统计学意义(P>0.05)。影像学方面:与克氏针组相比,在患肢负重位时钢板组喙锁间隙间距增加了23%(P<0.05),非负重位两组间距差异无统计学意义(P>0.05)。术后8~12周出现喙锁韧带钙化,钢板组12例、克氏针组2例(P<0.05)。术后6个月出现肩锁关节骨性关节炎,钢板组2例、克氏针组1例(P>0.05)。肩关节功能与影像学结果无相关性(r=0.096,P>0.05)。 结论 克氏针张力带联合喙锁韧带重建和锁骨钩钢板固定治疗RockwoodⅢ型肩锁关节脱位均可获得良好的临床功能。与克氏针张力带相比,锁骨钩钢板固定具有手术操作简便、疗效确切、并发症少、能够早期康复锻炼等优点。

    Release date:2016-09-08 09:12 Export PDF Favorites Scan
  • Arthroscopic treatment of scaphoid fracture nonunion with bone graft and Kirschner wire combined with screw fixation

    ObjectiveTo explore the effectiveness of arthroscopic treatment of scaphoid fracture nonunion with bone graft and Kirschner wire combined with screw fixation. MethodsThe clinical data of 14 patients with scaphoid fracture nonunion who met the selection criteria between February 2021 and September 2022 were retrospectively analyzed. There were 13 males and 1 female with an average age of 32 years ranging from 17 to 54 years. The time from injury to operation ranged from 6 to 15 months, with an average of 9.6 months. According to the Slade-Geissler classification of scaphoid fracture nonunion, there were 3 cases of grade Ⅲ, 8 cases of grade Ⅳ, and 3 cases of grade Ⅴ. The preoperative visual analogue scale (VAS) score was 5.9±1.0, and the modified Mayo wrist score was 53.2±9.1. There were 2 cases of scaphoid nonunion advanced collapse, both of which were stage Ⅰ. All patients were treated with arthroscopic bone graft and Kirschner wire combined with screw fixation, and the fracture healing was observed by X-ray film monthly after operation, and the effectiveness was evaluated by VAS score and modified Mayo wrist score before and after operation. ResultsAll patients were followed up 6-14 months, with an average of 8.4 months. All fractures healed in 4-8 months, with an average of 6.3 months. The postoperative pain symptoms and wrist function of the patients significantly improved when compared with those before operation, and the VAS score at last follow-up was 2.4±1.3, and the modified Mayo wrist score was 87.1±6.7, which were significantly different from those before operation (t=12.851, P<0.001; t=−14.410, P<0.001). According to the modified Mayo wrist evaluation, 9 cases were excellent, 3 cases were good, and 2 cases were fair. Conclusion Arthroscopic bone graft and Kirschner wire combined with screw fixation is an effective surgical method for the treatment of scaphoid fracture nonunion.

    Release date:2023-12-12 05:05 Export PDF Favorites Scan
  • 改良克氏针钢丝内固定治疗锁骨骨折46例

    Release date:2016-09-01 09:29 Export PDF Favorites Scan
  • 钩型克氏针内固定技术治疗Mallet 骨折

    目的 总结应用钩型克氏针内固定技术治疗 Mallet 骨折的临床疗效。 方法 2007 年 8 月- 2009 年1 月,收治 13 例 Mallet 骨折患者。其中男 9 例,女 4 例;年龄 18 ~ 56 岁,平均 30 岁。示指 6 例,中指 2 例,环指 1 例,小指 4 例。开放性损伤 2 例,闭合性损伤 11 例。采用 Wehbe 和 Schneider 分型,Ⅰ B 型 10 例,Ⅱ B 型 3 例。受伤至入院时间 40 min ~ 15 d,平均 5 d。术中采用单枚 1.0 mm 克氏针尾部制成钩型,关节背侧切开骨折复位,克氏针从指骨背侧进针贯穿指骨至指掌侧,钩部固定骨折,掌侧支具板固定克氏针,术后行限制性远指间关节早期屈伸锻炼。 结果 患者术后切口均Ⅰ期愈合。12 例获随访,随访时间 5 ~ 18 个月,平均 11 个月。骨折于术后 5 ~ 8 周达骨性愈合,平均 6 周。手指外观及功能恢复良好,无并发症发生。末次随访时疗效评估采用 Crawford 标准,获优 8 例,良 3 例,可 1 例,优良率91.7%。 结论 应用钩型克氏针内固定技术治疗 Mallet 骨折能有效降低术后关节疼痛及关节活动受限,是治疗 Mallet骨折的有效方法之一。

    Release date:2016-08-31 05:47 Export PDF Favorites Scan
  • Effectiveness comparison of open reduction and hook plate fixation versus closed indirect reduction and dorsal extension blocking Kirschner wire fixation for bony mallet finger

    Objective To compare the effectiveness of open reduction and hook plate fixation versus closed indirect reduction and dorsal extension blocking Kirschner wire fixation for bony mallet fingers. Methods The clinical data of 68 patients with bony mallet finger who admitted between May 2019 and June 2022 were retrospectively analyzed. Among them, 33 cases were in the open group (treated with open reduction and hook plate fixation) and 35 cases were in the closed group (treated with closed indirect reduction and dorsal extension blocking Kirschner wire fixation). There was no significant difference between the two groups in terms of gender, age, the affected side, the affected finger, cause of injury, time from injury to operation, and Wehbé-Schneider classification (P>0.05). The operation time, intraoperative fluoroscopy frequency, fracture healing time, time of returning to work, and postoperative complications were recorded and compared between the two groups. At 12 months after operation, visual analogue scale (VAS) score was used to assess the pain of the injured finger, active flexion range of motion and extension deficit of the distal interphalangeal joint (DIP) were measured by goniometer, and the effectiveness was assessed by Crawford criteria. Results All patients in the two groups were followed up 12-26 months, with an average of 15 months. There was no significant difference in the follow-up time between the closed group and the open group (P>0.05). The operation time in the closed group was shorter than that in the open group, and the intraoperative fluoroscopy times, the fracture healing time, and the time of returning to work in the closed group were more than those in the open group, and the differences were significant (P<0.05). In the closed group, there were 5 cases of pinning tract infection and 3 cases of small area pressure ulcer skin necrosis on the dorsal side of the finger, which were cured after intensive nursing and dressing change. Local nail depression deformity occurred in 7 cases in the open group, and the deformity disappeared after removal of plate. The incisions of the other patients healed uneventfully without complications such as infection, skin necrosis, exposure of the internal fixation, or nail deformity. There was no significant difference in the incidence of skin necrosis between the two groups (P>0.05), but the differences in the incidence of infection and nail deformity between the two groups were significant (P<0.05). There was no significant difference in VAS score, DIP active flexion range of motion, DIP extension deficiency, or Crawford criteria evaluation between the two groups at 12 months after operation (P>0.05). At last follow-up, there was no DIP osteoarthritis and joint degeneration in both groups. Conclusion Open reduction and hook plate fixation versus closed indirect reduction and dorsal extension blocking Kirschner wire fixation have their own advantages and disadvantages, but both of them have good results in the treatment of bony mallet fingers. Open reduction and hook plate fixation is recommended for young patients with bony mallet fingers who are eager to return to work.

    Release date:2024-08-08 09:03 Export PDF Favorites Scan
  • 克氏针“摇杆技术”辅助闭合复位内固定治疗儿童尺桡骨干双骨折

    目的评价克氏针“摇杆技术”辅助闭合复位钛弹性髓内钉内固定治疗儿童尺桡骨干双骨折的临床疗效。方法2016 年 11 月—2019 年 9 月采用克氏针“摇杆技术”辅助闭合复位钛弹性髓内钉内固定治疗 12 例儿童尺桡骨干双骨折。男 9 例,女 3 例;年龄 1~11 岁,平均 5 岁。均为新鲜闭合骨折,无血管、神经损伤。入院至手术时间 1~4 d,平均 3.2 d。结果手术时间平均 45 min,术中出血量平均 20 mL。术后切口均Ⅰ期愈合,无脂肪液化、切口皮缘坏死、感染及血管神经损伤等并发症发生。12 例均获随访,随访时间 4~24 个月,平均 17 个月。所有患儿骨折均获骨性愈合,愈合时间 8~14 周,平均 10 周。随访期间钉尾处皮肤无激惹、感染等并发症发生。末次随访时,肘关节功能根据 Flynn 评分标准评定,获优 10 例、良 2 例,优良率 100%。结论克氏针“摇杆技术”是一种新颖、有效的辅助闭合复位方法,联合钛弹性髓内钉内固定治疗儿童尺桡骨干双骨折具有微创、快速、安全的优点。

    Release date:2020-09-28 02:45 Export PDF Favorites Scan
5 pages Previous 1 2 3 4 5 Next