ObjectiveTo explore the effect of false acetabulum on the development and anatomical morphology of proximal femur in Crowe type Ⅳ developmental dysplasia of the hip (DDH), providing a theoretical basis for the development of femoral reconstruction strategy and prosthesis selection for total hip arthroplasty. Methods The medical records of 47 patients (54 hips) with Crowe type Ⅳ DDH between February 2008 and March 2020 were retrospectively analyzed, of which 21 patients (26 hips) were Crowe type Ⅳa (type Ⅳa group) and 26 patients (28 hips) were Crowe type Ⅳb (type Ⅳb group). There was no significant difference in general data such as gender, age, height, weight, body mass index, and side between the two groups (P>0.05), which were comparable. The height of femoral head dislocation, the height of pelvis, and the proportion of dislocation were measured based on preoperative anteroposterior pelvic X-ray film. Based on the preoperative femoral CT scan data, the anatomical parameters of the femur and femoral medullary cavity were measured after three-dimensional reconstruction using Mimics19.0 software to calculate the canal fare index; and the femoral medullary cavity parameters were matched with the modular S-ROM prosthesis parameters. ResultsThe results of X-ray film measurement showed that the height of femoral head dislocation and the proportion of dislocation in type Ⅳa group were significantly higher than those in type Ⅳb group (P<0.05). There was no significant difference in the height of pelvis between the two groups (P>0.05). The results of CT three-dimensional reconstruction measurements showed that compared with the type Ⅳb group, the type Ⅳa group had less isthmus height, smaller femoral head, shorter femoral neck, narrower neck-shaft angle, increased anteversion angle, and higher greater trochanter, and the differences were significant (P<0.05). There was no significant difference in the height of femoral head, femoral offset, and height difference between greater trochanter and femoral head between the two groups (P>0.05). There was no significant difference in the mediolateral width (ML), anteroposterior width (AP), and diameter of the isthmus (Ci level) and the AP of the medullary cavity in the plane 40 mm distal to the most prominent point on the medial side of the lesser trochanter (C–40 level) (P>0.05), and the size of medullary cavity was significantly smaller in type Ⅳa group than in type Ⅳb group at the other levels (P<0.05). Compared with the type Ⅳb group, the difference between the outer diameter of the prosthetic sleeve and the diameter of the medullary cavity fitting circle in the plane where the center of femoral head rotation was located from the medial most prominent point of the lesser trochanter (C0 level) in type Ⅳa group was smaller, and the proportion of negative values was greater (P<0.05). The difference between the longest diameter of the prosthetic sleeve triangle and the ML of the medullary cavity in the plane 10 mm proximal to the most prominent point on the medial side of the lesser trochanter (C+10 level) in type Ⅳa group was smaller, and the proportion of negative values was greater (P<0.05). ConclusionFalse acetabulum has a significant impact on the morphology of the proximal femur and medullary cavity in patients with Crowe type Ⅳ DDH, and the application of three-dimensional reconstruction technique can accurately evaluate the femoral morphology and guide the selection of femoral prosthesis.
Objective To investigate the changes of low back pain (LBP) and spinal sagittal parameters in patients with unilateral Crowe type Ⅳ developmental dysplasia of the hip (DDH) after total hip arthroplasty (THA). Methods The clinical data of 30 patients who met the selection criteria between October 2018 and March 2020 were retrospectively analyzed. Patients were divided into LBP group (16 cases) and control group (14 cases) according to whether there was LBP before operation. There was no significant difference between the two groups of patients in gender, age, body mass index, affected sides, preoperative Harris score (P>0.05). Full-length lateral X-ray films of the spine were taken within 1 week before operation and at 1 year after operation, and the following imaging indicators were measured: sacral slope (SS), lumbar lordosis (LL ), spinal tilt (ST), spine-sacral angle (SSA), sagittal vertebral axis (SVA). The visual analogue scale (VAS) score, lumbar Oswestry disability index (ODI), the Harris score of the hip joint before operation and at 1 year after operation, and the occurrence of postoperative complications were collected and analysed. Results In the LBP group, LBP was relieved to varying degrees at 1 year after operation, of which 13 patients (81.3%) had complete LBP remission; VAS score decreased from 4.9±2.3 preoperatively to 0.3±0.8, ODI decreased from 33.5±22.6 preoperatively to 1.3±2.9, the differences were all significant (t=7.372, P=0.000; t=5.499, P=0.000). There was no new chronic LBP in the control group during follow-up. The Harris scores of the two groups significantly improved when compared with those before operation (P<0.05); there was no significant difference between the two groups at 1 year after operation (t=0.421, P=0.677). There was no significant difference in imaging indexes between the two groups before operation and the difference between pre- and post-operation (P>0.05). At 1 year after operation, ST and SVA in the LBP group, SSA in the control group, and SS in the two groups significantly improved when compared with those before operation (P<0.05); there was no significant difference in the other indexes between the two groups before and after operation (P>0.05). Conclusion Unilateral Crowe type Ⅳ DDH patients with LBP before operation were all relieved of LBP after THA. The relief of LBP may be related to the improvement of spinal balance, but not to lumbar lordosis and its changes.
Objective To evaluate the early effectiveness and summarize the initial application experiences of Mako robot-assisted total hip arthroplasty (THA) for developmental dysplasia of the hip (DDH) in adults. Methods Between August 2018 and January 2020, 55 cases of DDH (75 hips) were treated with Mako robot-assisted THA. There were 10 males and 45 females with an average age of 51 years (range, 30-73 years). There were 35 cases of unilateral hip and 20 cases of bilateral hips. The DDH was classified as Crowe type Ⅰin 29 hips, type Ⅱ in 20 hips, type Ⅲ in 6 hips, and type Ⅳ in 20 hips. The modified Harris score was 54.8±16.0, the hip joint range of motion was 90° (80°, 100°), and the leg length discrepancy (LLD) was 22.0 (10.5, 47.0) mm. The preoperative surgical plan was made in the robot system based on the CT data. The reaming and installation of the acetabular cup were completed with the assistance of the robot system. The distance between the rotation center of the hip joint and the teardrop (horizontal distance, vertical distance), inclination angle, and anteversion angle were measured on the pelvic X-ray film to evaluate the position of the acetabular prosthesis. The above indicators were compared with preoperative planning to evaluate the accuracy of robotic-assisted surgery. The modified Harris score, the range of motion, and the LLD were used to evaluate the early effectiveness. Results The 75 hips of THAs were completed with the assistance of Mako robots. There was no significant difference in the acetabular inclination angle, the horizontal distance and the vertical distance of the rotation center between the preoperative planning and the postoperative measurement values (P>0.05); the acetabular anteversion angle was significantly smaller than the postoperative measurement value (t=–2.482, P=0.015). Four hips located beyond the Lewinnek safety zone, and 71 hips located within the Lewinnek safety zone. All patients followed up 6-24 months (mean, 13 months). All incisions healed by first intention. At last follow-up, the modified Harris score was 85.5±11.2, the hip joint range of motion was 120° (110°, 120°), and the LLD was 3.8 (2.0, 8.1) mm; all improved significantly compared with preoperative ones (P<0.05). Except for one nerve injury case, there was no other complication. Conclusion Mako robot-assisted THA is a safe and effective method for adult DDH, which can optimize the acetabular cup positioning, hip function, and leg length, but the long-term effectiveness needs to be confirmed by further studies.
Objective To evaluate early to medium-term effectiveness of total hip arthroplasty (THA) in patients with a history of hip preservation surgery with secondary severe osteoarthritis for developmental dysplasia of the hip (DDH). Methods The clinical data of 25 DDH patients (31 hips) who had severe osteoarthritis after hip preservation surgery and received THA between September 2009 and March 2021 were retrospectively analyzed. There were 1 male and 24 females; the age ranged from 18 to 65 years, with an average age of 43 years; 8 hips were classified into Crowe type Ⅰ, 9 hips were type Ⅱ, 3 hips were type Ⅲ, and 11 hips were type Ⅳ. The time between osteotomy and THA ranged from 31 to 51 years, with an average of 31.96 years. Preoperative hip flexion range of motion was (69.31±29.72)°, abduction range of motion was (24.00±14.79)°; and Harris hip score was 45.3±15.5. Postoperative Harris hip score, hip range of motion, complications, radiographic findings, and implant survival rate were analyzed. Results Patients in both groups were followed up 2-132 months, with an average of 51 months. During the follow-up, periprosthetic fracture occurred in 1 case; there was no complication such as dislocation, periprosthetic infection, nerve palsy, or deep vein thrombosis. At last follow-up, the hip flexion range of motion was (109.52±11.17)°, abduction range of motion was (41.25±5.59)°, showing significant differences when compared with preoperative values (t=8.260, P=0.000; t=6.524, P=0.000). The Harris hip score was 91.5±4.1, and the difference was significant when compared with preoperative score (t=11.696, P=0.000); among them, 13 cases were excellent and 12 cases were good. Radiographic evaluation showed that the center of acetabular rotation moved up 0-18 mm (mean, 6.35 mm). The cup abductor angle was 28°-49° (mean, 37.74°) and the coverage rate was 69.44%-98.33% (mean, 81.04%). All femoral stems were fixed in neutral position without varus or valgus. No osteolysis, radiolucent line, or implant migration was observed. By the end of follow-up, none of the patients underwent revision and the survival rate of prothesis was 100%. ConclusionTHA is still the gold standard for the treatment of DDH patients with secondary osteoarthritis after hip preservation surgery. The postoperative joint function can be rapidly restored, the patients’ quality of life can significantly improve, and the early to medium-term survival rate of the prosthesis is satisfactory.
ObjectiveTo investigate the influence of the degree of acetabular deformity and the learning-curve on the acetabular cup positions in total hip arthroplasty (THA) for adults with developmental dysplasia of hip (DDH). MethodsBetween January 2008 and December 2015, 130 patients (144 hips) with DDH underwent primary THA, and the clinical data were analyzed retrospectively. Fifty-three patients (59 hips) were admitted before 2012, and 77 patients (85 hips) were treated after 2012. There were 32 males and 98 females, aged from 31 to 83 years (mean, 61). Unilateral replacement was performed in 116 cases and bilateral replacement in 14 cases. Of 144 hips, 48 hips were rated as Crowe type I, 57 hips as type II, and 39 hips as type of III/IV. The standard pelvic radiograph was taken within 1 week after operation. The mediCAD software was adopted to measure the angle of anteversion and abduction, bony coverage, and the distance between true rotating center and optimal rotating center to the connection of teardrops and the horizontal distance between two centers to evaluate the qualified rate of acetabular cup positions. ResultsCompared with the patients with the same type in 2013-2015 group, the anteversion angle and qualified rate of acetabular cup position significantly decreased in patients with Crowe I (P < 0.05); the horizontal distance significantly increased and qualified rate of acetabular cup position significantly decreased in patients with Crowe II (P < 0.05); and the anteversion angle significantly decreased and the horizontal distance significantly increased in patients with Crowe III/IV (P < 0.05) in 2008-2012 group. But no significant difference was shown in the other indexes (P > 0.05). In all Crowe types, the vertical distance between the true rotating center and the optimal rotating center increased with the degree of acetabular deformity in both 2008-2012 group and 2013-2015 group, showing significant difference (P < 0.05), but no significant difference was found in the other indexes (P > 0.05). ConclusionFor adults with acetabular dysplasia, there are high potential risks for unsatisfactory acetabular cup positions during primary THA. So it is necessary to evaluate acetabular deformities and to sum up operative experience so as to improve the accuracy of cups installation.
Objective To summarize the biomechanical characteristics, diagnosis, and hip arthroscopic treatment of borderline developmental dysplasia of hip (BDDH) with Cam-type femoroacetabular impingement (Cam FAI). Methods The literature on BDDH with Cam FAI at home and abroad in recent years was extensively reviewed and analyzed. Results In patients with BDDH and Cam FAI, the femoral neck anteversion angle and femoral neck shaft angle increase, the pelvis tilts, and the acetabulum rotates, resulting in instability of the hip joint. In order to maintain the stability of the hip joint, the direction of biomechanical action of the hip joint has changed, which further affects the anatomical structures such as the proximal femur and acetabular morphology. BDDH with Cam FAI can be diagnosed clinically by combining lateral center edge angle, anterior center edge angle, and acetabular index. BDDH with Cam FAI can be effectively treated through arthroscopic polishing of the edges of the acetabular proliferative bone, excision of Cam malformations, and minimally invasive repair of the glenoid lip and cartilage of the hip joint. Conclusion Currently, there is no unified standard for the diagnosis and treatment of BDDH with Cam FAI. Minimally invasive treatment of the hip under arthroscopy can achieve good early- and medium-term effectiveness, and has certain advantages in repairing and maintaining the integrity of the glenoid lip and suturing/compression joint capsule. However, the long-term effectiveness needs to be further followed up to determine. The timing of surgery, intraoperative bone edge depth polishing, and joint capsule suturing/compression techniques also need to be further explored.
Objective To investigate the effects of femoral offset and mechanical axis of the lower extremity on hip after osteotomy for adult developmental dysplasia of the hip (DDH). Methods A clinical data of 62 adult patients with DDH (62 hips), who underwent periacetabular osteotomy combined with femoral osteotomy between January 2016 and May 2019 and met selective criteria, was retrospectively analyzed. There were 6 males and 56 females. The age ranged from 18 to 38 years, with an average of 24.4 years. Body mass index ranged from 15.8 to 31.8 kg/m2, with an average of 21.8 kg/m2. There were 44 cases of Hartofilakidis typeⅠ and 18 cases of typeⅡ. According to the modified Tönnis osteoarthritis staging, 46 cases were stage 0 and 16 cases were stageⅠ. There were 13 cases with pelvic anteversion, 40 cases with normal pelvis, and 9 cases with pelvic retroversion. Intraoperative blood loss, length of hospital stay, and complications were recorded. Postoperative hip function was evaluated by Harris score and International Hip Outcome Tool (iHOT) score. The femoral offset, collo-diaphyseal angle, hip-knee-ankle angle (HKA), knee valus angle, CE (Wiberg central-edge angle), anterior CE angle, and acetabular index angle were measured and the osteotomy healing was observed on X-ray films. Patients were grouped according to postoperative femoral offset (≥48 mm or <48 mm) and HKA [varus group (HKA<177°), normal group (HKA 177°-183°), and valgus group (HKA>183°)]. Harris score and iHOT score were compared between groups. Results Intraoperative blood loss ranged from 200 to 1 550 mL, with an average of 476 mL. The length of hospital stay ranged from 8 to 21 days, with an average of 13.3 days. All incisions healed by first intention. All patients were followed up 2.0-4.5 years, with an average of 2.8 years. At 1 year after operation, the Harris score and iHOT score of the hip joint significantly increased when compared with those before operation (P<0.05); there were significant differences in the femoral offset, collo-diaphyseal angle, HKA, knee valus angle, CE angle, anterior CE angle, and acetabular index angle between pre- and post-operation (P>0.05). According to the modified Tönnis osteoarthritis staging, 38 cases were stage 0 and 24 cases were stageⅠ; and there was no significant difference between pre- and post-operation (χ2=2.362, P=0.124). There were 11 cases with pelvic anteversion, 38 cases with normal pelvis, and 13 cases with pelvic retroversion, showing no significant difference when compared with that before operation (χ2=0.954, P=0.623). The pubic branch osteotomy did not heal in 9 cases, proximal femur osteotomy did not heal in 2 cases, and inferior pubic ramus stress fracture occurred in 5 cases. There were significant differences (P<0.05) in the Harris score and iHOT score between femoral offset≥48 mm group (n=10) and femoral offset<48 mm group (n=52). There was no significant difference (P>0.05) in Harris score and iHOT score between varus group (n=13), normal group (n=40), and valgus group (n=9). Conclusion Periacetabular osteotomy combined with femoral osteotomy can improve the femoral offset and mechanical axis of the lower extremity of patients with DDH, and improve the functional score of the hip. However, excessive increase of femoral offset during femoral osteotomy is not desirable, resulting in low postoperative functional score.
Objective To investigate the effectiveness of Salter osteotomy combined with subtrochanteric shortening and derotational osteotomy in treating Tönnis type Ⅲ and Ⅳ developmental dysplasia of the hip (DDH) in children and explore the urgical timing. Methods A retrospective collection was performed for 74 children with Tönnis type Ⅲ and Ⅳ DDH who were admitted between January 2018 and January 2020 and met the selection criteria, all of whom were treated with Salter osteotomy combined with subtrochanteric shortening and derotational osteotomy. Among them, there were 38 cases in the toddler group (age, 18-36 months) and 36 cases in the preschool group (age, 36-72 months). There was a significant difference in age between the two groups (P<0.05), and there was no significant difference in gender, side, Tönnis typing, and preoperative acetabular index (AI) (P>0.05). During follow-up, hip function was assessed according to the Mckay grade criteria; X-ray films were taken to observe the healing of osteotomy, measure the AI, evaluate the hip imaging morphology according to Severin classification, and assess the occurrence of osteonecrosis of the femoral head (ONFH) according to Kalamchi-MacEwen (K&M) classification criteria. Results All operations of both groups were successfully completed, and the incisions healed by first intention. All children were followed up 14-53 months, with an average of 27.9 months. There was no significant difference in the follow-up time between the two groups (P>0.05). At last follow-up, the excellent and good rates according to the Mckay grading were 94.73% (36/38) in the toddler group and 83.33% (30/36) in the preschool group, and the difference between the two groups was significant (P<0.05). The imaging reexamination showed that all osteotomies healed with no significant difference in the healing time between the two groups (P>0.05). There was no significant difference in AI between the two groups at each time point after operation (P>0.05), and the AI in the two groups showed a significant decreasing trend with time extension (P<0.05). The result of Severin classification in the toddler group was better than that in the preschool group at last follow-up (P<0.05). There was no significant difference in the incidence of ONFH between the two groups (P>0.05). In the toddler group, 2 cases were K&M type Ⅰ; in the preschool group, 3 were type Ⅰ, and 1 type Ⅱ. There was no dislocation after operation.ConclusionSalter osteotomy combined with subtrochanteric shortening and derotational osteotomy is an effective way to treat Tönnis type Ⅲ and Ⅳ DDH in children, and surgical interventions for children aged 18-36 months can achieve better results.
Objective By comparing with the traditional X-ray template measurement method, to explore the accuracy of artificial intelligence preoperative planning system (AI-HIP) to predict the type of prosthesis and guide the placement of prosthesis before total hip arthroplasty (THA) in adult patients with developmental dysplasia of the hip (DDH). Methods Patients with DDH scheduled for initial THA between August 2020 and August 2022 were enrolled as study object, of which 28 cases (28 hips) met the selection criteria were enrolled in the study. Among them, there were 10 males and 18 females, aged from 34 to 77 years, with an average of 59.3 years. There were 12 cases of the left DDH and 16 cases of the right DDH. According to DDH classification, there were 10 cases of Crowe type Ⅰ, 8 cases of type Ⅱ, 5 cases of type Ⅲ, and 5 cases of type Ⅳ. According to Association Research Circulation Osseous (ARCO) staging of osteonecrosis of the femoral head, 13 cases were in stage Ⅲ and 15 cases in stage Ⅳ. The disease duration was 2.5-23.0 years (mean, 8.6 years). The limb length discrepancy (LLD) was 11.0 (8.0, 17.5) mm. Before operation, the prosthesis types of all patients were predicted by AI-HIP system and X-ray template measurement method, respectively. And the preoperative results were compared with the actual prosthesis type during operation in order to estimate the accuracy of the AI-HIP system. Then, the differences in the acetabular abduction angle, acetabular anteversion angle, femoral neck osteotomy position, tip-shoulder distance, and LLD were compared between preoperative planned measurements by AI-HIP system and actual measurement results after operation, in order to investigate the ability of AI-HIP system to evaluate the placement position of prosthesis. Results The types of acetabular and femoral prostheses predicted based on AI-HIP system before operation were consistent with the actual prostheses in 23 cases (82.1%) and 24 cases (85.7%), respectively. The types of acetabular and femoral prostheses predicted based on X-ray template measurement before operation were consistent with the actual prostheses in 16 cases (57.1%) and 17 cases (60.7%), respectively. There were significant differences between AI-HIP system and X-ray template measurement (P<0.05). There was no significant difference in acetabular abduction angle, acetabular anteversion angle, femoral neck osteotomy position, and tip-shoulder distance between AI-HIP system and actual measurement after operation (P>0.05). LLD after operation was significantly lower than that before operation (P<0.05). There was no significant difference between the LLD predicted based on AI-HIP system and the actual measurement after operation (P>0.05). Conclusion Compared with the traditional X-ray template measurement method, the preoperative planning of AI-HIP system has better accuracy and repeatability in predicting the prosthesis type. It has a certain reference for the prosthesis placement of adult DDH.