west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "外固定支架" 26 results
  • UNILATERAL EXTERNAL FIXATOR IN THE TREATMENT OF INTERTROCHANTERIC FRACTURES OF FEMUR

    Forty cases of intertrochanteric fractures of femur were treated with percutaneous nonmetallic external fixator. The patients were followed up for 6 months to 3 years, and the fractures were all united without coxa vara or shirtening deformities. There was no mortality in this series. This method had the advantages ofbeing simple, save time and effort, less traumatic and early ambulation. The design of the apparatus tallied with the biomechanics of the neck and shaft of the femur.

    Release date:2016-09-01 11:12 Export PDF Favorites Scan
  • Clinical Study on Kirschner Wire Limited Internal Fixation plus External Fixation for Patients with Tarsometatarsal Fracture Dislocation

    ObjectiveTo observe the efficacy of and influencing factors for kirschner wire limited internal fixation plus external fixation for patients with tarsometatarsal fracture dislocation. MethodsThe efficacy of kirschner wire limited internal fixation plus external fixation treatment for patients with tarsometatarsal fracture dislocation treated between January 2004 and June 2009 was retrospectively analyzed,and we also investigated the impact of surgery time and ligament damage on its long-term prognosis. ResultsTwenty patients were included,consisting of 16 male and 4 female patients,ranging from 15 to 57 years old.The mean time of follow-up was 24.5 months,ranging from 11 to 41 months.At the time of follow-up,there were 5%(1/20),10%(2/20),50%(10/20) and 35%(7/20) patients with AOFAS ankle-hindfoot score at 0~69,70~79,80~89 and 90-100,respectively;and the excellent rate was 85% in total.In this cohort,the acceptance rate of the results of treatment was 95% at discharging and 85% at the final follow-up,and the difference between the above two time-points was not statistically significant.In addition,patients with earlier surgery treatment and lower degree of ligament injury had better long-term prognosis. ConclusionFor patients with tarsometatarsal fracture dislocation,treatment with kirschner wire limited internal fixation plus external fixation can not only effectively restore joint function,but also has minimum surgical trauma,and it is an effective method for the treatment of tarsometatarsal joint injuries.

    Release date: Export PDF Favorites Scan
  • 肘关节分裂脱位一例

    Release date:2018-02-07 03:21 Export PDF Favorites Scan
  • EFFECTIVENESS COMPARISON OF EXTERNAL FIXATION AND VOLAR LOCKING COMPRESSION PLATE IN TREATMENT OF DISTAL RADIUS FRACTURES OF TYPE C

    ObjectiveTo compare the effectiveness of external fixation and volar locking compression plate in the treatment of distal radius fractures of type C. MethodsBetween March 2012 and March 2013, 122 patients with distal radius fractures of type C were enrolled in the prospective randomized study. Fractures were treated by external fixation in 61 patients (external fixation group) and by open reduction and internal fixation using a volar locking compression plate in 61 patients (plate group). There was no significant difference in age, gender, fracture side, weight, height, body mass index, fracture type, and interval of injury and operation between 2 groups (P>0.05). The blood loss, operation time, hospitalization days, fracture union time, wrist function, and complications were compared between 2 groups. And the quality of reduction was observed, including volar tilting angle, ulnar deviation, radial height, and articular reduction. ResultsThe blood loss, operation time, and hospitalization days in plate group were significantly higher than those in external fixation group (P<0.05). All of the patients in both groups were followed up 12-28 months. Postoperative complications occurred in 4 patients (6.6%) of external fixation group (pin tract infection in 2 cases and radial nerve neuritis in 2 cases) and in 5 patients (8.2%) of plate group (wound infection in 1 case, carpal tunnel syndrome in 2 cases, and tendon rupture in 2 cases), showing no significant difference between 2 groups (P=0.500). The X-ray films showed fracture healing in all patients of 2 groups; the union time of plate group was significantly longer than that of external fixation group (P<0.05). At last follow-up, there was no significant difference in ulnar deviation and radial height between 2 groups (P>0.05), but the volar tilting angle of plate group was significantly larger than that of external fixation group (P<0.05). There was no significant difference in wrist function and articular reduction between 2 groups (P>0.05). ConclusionFor distal radius fractures of type C, the use of external fixation or volar locking compression plate can obtain satisfactory clinical outcomes, but the external fixation has the advantages of less invasion, shorter hospitalization days, minor complications, and faster fracture union.

    Release date: Export PDF Favorites Scan
  • Multifunctional External Fixator for the Treatment of Femoral Intertrochanteric Fracture

    【摘要】 目的 探讨多功能外固定支架治疗老年股骨粗隆间骨折的疗效和优点。 方法 2007年7月-2009年10月,采用外固定架治疗28例老年股骨粗隆间骨折患者,其中男11例,女17例;年龄74~91岁,平均81岁。致伤原因:摔伤25例,交通事故伤3例。骨折按Evans分型:Ⅰ型1例,Ⅲ型15例,Ⅳ型12例。受伤至手术时间2~7 d。 结果 术后患者切口均Ⅰ期愈合,无延迟愈合及其他早期并发症发生。28例均获随访,随访时间5~14个月,平均9个月。X线片示骨折全部愈合,愈合时间11~24周,平均17周。无髋内翻和下肢短缩等并发症发生。术后3个月,采用Harris评分进行功能评价,优18例,良7例,差3例,优良率89.3%。出现轻度针道感染7例,中度5例,重度2例,针道感染率50%;合并糖尿病者2例出现中度针道感染,2例出现重度针道感染。重度者经局部换药、应用抗生素后愈合,后又反复出现,2~3个月取钉后愈合。无骨感染发生,患者均未出现褥疮,合并症无明显加重。 结论 外固定架治疗粗隆间骨折,手术创伤小,操作简便,符合生物力学原理,可以早期离床活动及早期骨折愈合。【Abstract】 Objective To explore the effectiveness and advantages of multifunctional external fixator for the treatment of femoral intertrochanteric fractures in the elderly patients.  Methods Twenty-eight patients with femoral intertrochanteric fractures including 11 males and 17 females receiving external fixator treatment between July 2007 and October 2009 were enrolled in this study. Their age ranged from 74 to 91 years old with the average to be 81 years. Twenty-five patients had the disease because of ground falls, and the other 3 were due to traffic accidents. Based on the Evans Type classification, there were 1 Type-Ⅰ case, 15 Type-Ⅲ cases, and 12 Type-Ⅳ cases. The time between injury and surgery was ranged from 2 to 7 days. Results All incisions of the patients healed during phase Ⅰ without delayed healing or other early complications. Follow-up was done to all the patients for 5 to 14 months, averaging 9 months. X-ray showed all fractures healed, and the healing time ranged from 11 to 24 weeks with an average of 17 weeks. No varus or leg shortening or other complications occurred. Three months after surgery, based on the Harris hip score for functional evaluation, there were 18 excellent cases, 7 good cases and 3 poor cases with a excellent and good rate of 89.3%. Mild pin tract infection was detected in 7 patients, moderate in 5, and severe in 2 with a total pin tract infection rate of 50%. Two patients with diabetes suffering from severe pin tract infection recovered by local medication and antibiotics, but the infection reoccurred repeatedly till the healing nails were taken. No bone infection of ulcers occurred, and the existing complications were not aggravated. Conclusion Treatment of intertrochanteric fractures with multifunctional external fixator is minimally invasive, simple, and consistent with biomechanical principles, which can promote early activities out of bed and early fracture healing for the patients.

    Release date:2016-09-08 09:26 Export PDF Favorites Scan
  • APPLICATION OF THE MINOR UNILATERAL MULTIFUNCTIONAL EXTERNAL FIXATOR IN HAND SURGER

    A series of 28 cases of fractures of the small tubular bones of the hand, including Bennetts fracture, were treated with the minor unilateral multifunctional external fixator. After manipulation, a hole was drilled on the proximal and distal parts of the fractured bone. Hand in functional position, the external fixator was set in place. Functional exercises were begun after the fixation. The patients were follwed up for two to six months. The average healing time was thirtyfive days. The average healing time for Bennett’s fractures was twentyeight days, and for the fractures of metacarpal bone was forty-two days. There were no deformity and complication of infection following external fixation.The functional recovery of the hands was satisfactory. The fixator had the following advantages: It was simple and had tight fixation; fractures with infection, was still indicated and could be adjusted according to the clinical purpose.

    Release date:2016-09-01 11:16 Export PDF Favorites Scan
  • BIOMECHANICS STUDY ON THREE-DIMENSIONAL EXTERNAL FIXATOR FOR OSTEOPOROTIC FRACTURE

    ObjectiveTo explore the mechanical stability of the three-dimensional (3-D) external fixator for osteoporotic fracture so as to provide the biomechanical basis for clinical application. MethodsForty-five fresh frozen adult tibial specimens were selected to rapidly prepare the extracorporal tibia osteoporotic fracture models, and were randomly divided into 3 groups (n=15). Fractures were fixed with 3-D external fixators (3-D external fixators group), intramedullary nails (intramedullary nail group), and plate (plate group) respectively. Five specimens randomly from each group were used to do axial compression test, three-point bending test, and torsion test with microcomputer control electronic universal testing machine, then the mechanical parameters were calculated. ResultsIn the axial compression test, the displacement of 3-D external fixator group and intramedullary nail group were shorter than plate group, showing significant differences (P<0.05); but no significant difference was found between 3-D external fixator group and intramedullary nail group (P>0.05). In the three-point bending test and torsion test, the deflection and the torsional angle of 3-D external fixator group and intramedullary nail group were smaller than plate group, showing significant differences (P<0.05); but no significant difference was found between 3-D external fixator group and intramedullary nail group (P>0.05). ConclusionThe 3-D external fixator can fix fracture three-dimensionally from multiple plane and it can offer strong fixing. It is biomechanically demonstrated to be suitable for osteoporotic fracture.

    Release date:2016-08-25 10:18 Export PDF Favorites Scan
  • 外固定架结合有限内固定治疗新鲜胫腓骨开放性粉碎性骨折

    Release date:2016-09-01 09:28 Export PDF Favorites Scan
  • Effectiveness comparison of suspension fixation plus hinged external fixator and double plate internal fixation in treatment of type C humeral intercondylar fractures

    Objective To compare the effectiveness of suspension fixation plus hinged external fixator with double plate internal fixation in the treatment of type C humeral intercondylar fractures. Methods Between January 2014 and April 2016, 30 patients with type C (Association for the Study of Internal Fixation, AO/ASIF) humeral intercondylar fractures were treated. Kirschner wire suspension fixation plus hinged external fixator was used in 14 cases (group A), and double plate internal fixation in 16 cases (group B). There was no significant difference in gender, age, injury cause, disease duration, injury side, and type of fracture between 2 groups (P>0.05). Results There was no significant difference in operation time and hospitalization stay between 2 groups (P>0.05). But the intraoperative blood loss in group A was significantly less than that in group B (P<0.05); the visual analogue scale (VAS) score at 1 day and 3 days after operation in group A were significantly less than those in group B (P<0.05). Primary healing of incision was obtained in all patients of 2 groups, and no surgery-related complications occurred. The patients were followed up 6-24 months (mean, 12.3 months) in group A and 6-24 months (mean, 12.8 months) in group B. The self-evaluation satisfaction rate was 85.7% (12/14) in group A and was 81.2% (13/16) in group B at 3 months after operation, showing no significant difference (χ2=0.055, P=0.990). Based on the improved Gassebaum elbow performance score at 6 months after operation, excellent and good rate of the elbow function was 78.6% (excellent in 5 cases, good in 6 cases, fair in 2 cases, and poor in 1 case) in group A and was 81.2% (excellent in 6 cases, good in 7 cases, fair in 2 cases, and poor in 1 case) in group B, showing no significant difference between 2 groups (χ2=0.056, P=0.990). Heterotopic ossification occurred at 3 months after operation in 1 case of each group respectively. The X-ray films showed bony union in all cases; no loosening or breakage of screw was observed. The bone union time showed no significant difference between 2 groups (t=–0.028, P=0.978). The time of internal fixation removal, the intraoperative blood loss, and VAS score at 1 day and 3 days after operation in group A were significant better than those in group B (P<0.05). Conclusion The suspension fixation plus hinged external fixator and double plate internal fixation for the treatment of type C humeral intercondylar fractures have ideal outcome in elbow function. But the suspension fixation plus hinged external fixator is better than double plate internal fixation in intraoperative blood loss, postoperative VAS score, and time of internal fixation removal.

    Release date:2017-07-13 11:11 Export PDF Favorites Scan
  • COMPARATIVE STUDY ON INTERNAL FIXATION AND EXTERNAL FIXATION FOR THE TREATMENT OFCOMPLEX TIBIAL PLATEAU FRACTURE

    Objective To compare effects, advantages and disadvantages of simple internal fixation to that of l imited internal fixation with external supporting frame fixation in the treatment of complex fractures of tibial plateau. Methods From July 2002 to August 2006, 66 cases of complex fractures of the tibial plateau were divided into the internal fixation group (n=39) and the external fixator group (n=27). The interal fixation group had 18 cases of IV, 7 cases V and 14 cases VI according to Schatzker, including 25 males and 14 females aged 18-79 years with an average of 45.4 years. The external fixator group had 13 cases of IV, 6 cases V and 8 cases VI according to Schatzker, including 18 males and 9 femles aged 18-64 years with an average of 44.2 years. No significant difference was evident between the two groups (P gt; 0.05). Patients were treated by using screws, steel plates or external supporting frame fixation strictly based on the princi ple of internalfixation. Results All patients were followed up for 1-5 years. Fracture healed with no occurrence of nonunion. Two cases inthe internal fixation group presented partial skin infection and necrosis, and were cured through the dressing change and flap displacement. Fracture heal ing time was 6-14 months with an average of 7.3 months. The time of internal fixator removal was 6-15 months with an average of 8.3 months. In the external fixation group, 11 cases had nail treated fluid 7 days to 3 months after operation, combining with red local skin; 3 cases had skin necrosis; and 3 cases had loose bolts during follow-up. Through debridement, dressing change and flap displacement, the skin wounds healed. Fracture heal ing time was 3-11 months with an average of 5.1 months. The time of external fixator removal was 5-11 months with an average of 6.4 months. At 8-14 months after operation, the knee function was assessed according to Merchant criteria. In the internal fixation group, 29 cases were excellent, 4 good, 5 fair and 1 poor, while in the external fixation group, 20 cases were excellent, 3 good, 2 fair and 2 poor. There was no significant difference between the two groups (P gt; 0.05). Conclusion The therapeutic effects of simple internal fixation and l imited internal fixation with external supporting frame fixation were similar in the treatment of complex fractures of tibial plateau. Fixation materials should be selected according to the state of injury and bone conditions for the treatment of tibial plateau fracture of type IV, V and VI based on Sehatzker classification.

    Release date:2016-09-01 09:16 Export PDF Favorites Scan
3 pages Previous 1 2 3 Next

Format

Content