west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "外固定架" 29 results
  • 外固定架固定骨折在肢体严重损伤修复中的应用

    Release date:2016-09-01 09:25 Export PDF Favorites Scan
  • Limited internal fixation combined with a hinged external fixator in treatment of peri-elbow bone infection

    Objective To evaluate the effectiveness of limited internal fixation combined with a hinged external fixator in the treatment of peri-elbow bone infection. Methods The clinical data of 19 patients with peri-elbow bone infection treated with limited internal fixation combined with a hinged external fixator between May 2018 and May 2021 were retrospectively analyzed. There were 15 males and 4 females with an average age of 44.6 years (range, 28-61 years). There were 13 cases of distal humerus fractures and 6 cases of proximal ulna fractures. All the 19 cases were infected after internal fixation of fracture, and 2 cases were complicated with radial nerve injury. According to Cierny-Mader anatomical classification, 11 cases were type Ⅱ, 6 cases were type Ⅲ, and 2 cases were type Ⅳ. The duration of bone infection was 1-3 years. After primary debridement, the bone defect was (3.04±0.28) cm, and the antibiotic bone cement was implanted into the defect area, and the external fixator was installed; 3 cases were repaired with latissimus dorsi myocutaneous flap, and 2 cases were repaired with lateral brachial fascial flap. Bone defects repair and reconstruction were performed after 6-8 weeks of infection control. The wound healing was observed, and white blood cell (WBC), erythrocyte sedimentation rate (ESR), and C-reaction protein (CRP) were reexamined regularly after operation to evaluate the infection control. X-ray films of the affected limb were taken regularly after operation to observe the bone healing in the defect area. At last follow-up, the flexion and extension range of motion and the total range of motion of the elbow joint were observed and recorded, and compared with those before operation, and the function of the elbow joint was evaluated by Mayo score. Results All patients were followed up 12-34 months (mean, 26.2 months). The wounds healed in 5 cases after skin flap repair. Two cases of recurrent infection were effectively controlled by debridement again and replacement of antibiotic bone cement. The infection control rate was 89.47% (17/19) in the first stage. Two patients with radial nerve injury had poor muscle strength of the affected limb, and the muscle strength of the affected limb recovered from grade Ⅲ to about grade Ⅳ after rehabilitation exercise. During the follow-up period, there was no complication such as incision ulceration, exudation, bone nonunion, infection recurrence, or infection in the bone harvesting area. Bone healing time ranged from 16 to 37 weeks, with an average of 24.2 weeks. WBC, ESR, CRP, PCT, and elbow flexion, extension, and total range of motions significantly improved at last follow-up (P<0.05). According to Mayo elbow scoring system, the results were excellent in 14 cases, good in 3 cases, and fair in 2 cases, and the excellent and good rate was 89.47%. ConclusionLimited internal fixation combined with a hinged external fixator in the treatment of the peri-elbow bone infection can effectively control infection and restore the function of the elbow joint.

    Release date:2023-06-07 11:13 Export PDF Favorites Scan
  • Clinical application of Taylor spatial frame in adjustment of lower extremity force line of knee medial compartmental osteoarthritis

    ObjectiveTo explore the safety and effectiveness of Taylor spatial frame (TSF) in the treatment of medial compartmental osteoarthritis (MCOA) of the knee and the adjustment of the lower extremity force line at the same time.MethodsThe clinical data of 30 patients with MCOA who underwent high tibial osteotomy (HTO) between October 2016 and April 2017 were retrospectively analyzed. According to the different fixation methods, they were divided into external fixation group (TSF external fixation, 16 cases) and internal fixation group (locking steel plate internal fixation, 14 cases). There was no significant difference between the two groups in gender, age, side, disease duration, mechanical femur tibia angle (MFTA), and other general data (P>0.05). The operation time and intraoperative blood loss of the two groups were recorded and compared; MFTA was used to evaluate the recovery of the lower extremity force line at last follow-up; Hospital for Special Surgery (HSS) score was used to evaluate the clinical effecacy before operation and at 2 weeks, 1 month, and 3 months after operation.ResultsThe operation time and intraoperative blood loss of external fixation group were significantly less than those of internal fixation group (P<0.05). All patients were followed up 9-16 months, with an average of 12 months. There were 2 cases of delayed healing in the internal fixation group and 1 case of delayed healing in the external fixation group, and all healed after symptomatic treatment. All patients in the two groups had no complication such as needle infection, nonunion at osteotomy, osteomyelitis, and so on. At last follow-up, MFTA standard was used to evaluate the recovery of force line. The results of external fixation group were all excellent, while the results of internal fixation group were excellent in 10 cases and good in 4 cases. The difference between the two groups was significant (Z=–2.258, P=0.024). The HSS scores in the two groups were significantly improved at each time point after operation, and gradually improved with time after operation (P<0.05). The HSS score of the external fixation group was significantly higher than that of the internal fixation group (t=2.425, P=0.022) at 3 months after operation; and there was no significant difference between the two groups at other time points (P>0.05).ConclusionTSF has unique advantages in HTO treatment of MCOA patients and correction of lower extremity force line, such as shorter operation time, less bleeding, firm fixation, and less complications. It can accurately adjust the lower extremity force line after operation and has good effectiveness. It is an effective and safe fixation method.

    Release date:2020-04-29 03:03 Export PDF Favorites Scan
  • 微型外固定支架重建掌指骨支架

    Release date:2016-09-01 09:25 Export PDF Favorites Scan
  • Mid-term effectiveness of arthrolysis and hinged external fixation for treatment of stiff elbow caused by heterotrophic ossification

    ObjectiveTo evaluate the mid-term effectiveness of arthrolysis and hinged external fixation for the treatment of stiff elbow caused by heterotrophic ossification.MethodsBetween January 2014 and December 2017, 11 patients with stiff elbow caused by heterotrophic ossification were admitted. There were 9 males and 2 females with an average age of 32 years (range, 14-48 years), and left side in 6 cases and right side in 5 cases. The cause of stiff elbow included humerus fracture in 5 cases, ulna fracture in 2 cases, fracture of capitulum radii in 1 case, dislocation of capitulum radii in 1 case, terrible triad of the elbow in 1 case, and soft tissue injury in 1 case. The disease duration ranged from 7 to 18 months (mean, 11 months). Preoperative active range of motion of elbow was (19.6±17.5)° and Mayo score was 34.1±9.7. All patients received the treatment of arthrolysis and debridement of heterotrophic ossification lesion combining hinged external fixator, and active and passive rehabilitation with the help of hinged external fixator. The hinged external fixators were removed after 2 months.ResultsAll patients were followed up 13-36 months (mean, 19.1 months). All incisions healed by first intention, and no complication of infection or nerve lesion occurred postoperatively. At last follow-up, the results of X-ray films showed that no heterotrophic ossification recurred. The active range of motion of elbow was (116.4±16.6)° and Mayo score was 93.2±7.8, showing significant differences when compared with preoperative ones (t=17.508, P=0.000; t=16.618, P=0.000).ConclusionThe application of arthrolysis and debridement of heterotrophic ossification lesion combining hinged external fixator can improve the elbow’s range of motion significantly and obtain a good mid-term effectiveness.

    Release date:2019-09-18 09:49 Export PDF Favorites Scan
  • TREATMENT OF OLD TILE B1 PELVIC FRACTURE BY STAGED PELVIC CLOSURE USING EXTERNAL FIXATORCOMBINED WITH RECONSTRUCTION PLATE

    【Abstract】 Objective To summary the effects of staged pelvic closure using external fixator combined withreconstruction plate for old Tile B1 pelvic fracture. Methods From August 2000 to August 2006, 14 patients (9 males and 5 females, age ranging from 21 to 65 years with old Tile B1 pelvic fracture with pubic symphysis separation were treated. The injuries were caused by the traffic accident in 10 patients, high crash in 3, and crush in 1. The duration ranged from 4 weeks to 3 months. The 14 patients were compl icated with other injuries in some degrees. The X-ray and CT showed pubic symphysis separation. In 13 patients, pubic symphysis separation distance was more than 2.5 cm, who also had fracture or dislocation in the posterior structure of pelvis. The X-ray films showed the mean pubic symphysis separation distance was (6.67 ± 2.11) cm preoperatively. The 14 patients underwent pelvic external fixation at first and staged pelvic closure gradually for the pubic symphysis separation. After 2 to 3 weeks, when the pubic symphysis separation distance was less than 1 cm, the patients underwent open reduction and internal fixation with reconstruction plate. Pubic symphysis separation distance was measuredin the preoperative and postoperative pelvic anterioposterior X-ray films. The condition of the posterior structure of pelvis was observed in CT films. The functions of patients were assessed according to Majeed grading system. Results All incisions healed by first intention. The 14 patients were followed up for 6 months to 2 years (15 months on average). The X-ray films showed the mean pubic symphysis separation distance of post-operation was (0.85 ± 0.23) cm, showing statistically significant difference when compared with that of pre-operation (P lt; 0.05). The CT films showed fracture and dislocation of the posterior structure of pelvis had bony heal ing after 6 to 12 months. According to the Majeed grading system, the results were excellent in 5 cases, good in 4 cases, fair in 4 cases and poor in 1 case; the excellent and good rate was 64.29%. Conclusion Staged pelvic closure using external fixation combined with reconstruction plate for old pelvic fracture with pubic symphysis separation can reduce the pubic symphysis separation distance significantly. Satisfactory effects can be expected in treating the patients with TileB1 fracture.

    Release date:2016-09-01 09:10 Export PDF Favorites Scan
  • LESS INVASIVE LEVERAGE REDUCTION WITH EXTERNAL FIXATOR SUPPORTED AND BONE GRAFT FORTREATMENT OF UNSTABLE FRACTURES OF DISTAL RADIUS

    【Abstract】 Objective To assess the results of treatment of unstable distal radius fractures with leverage reductionand bone graft assisted by external fixators. Methods From September 2005 to May 2007, 27 cases of unstable distal radius fractures were treated by leverage reduction and bone graft, meanwhile assisted by external fixators. The cases included 16 males and 11 females, aged from 18 to 69 years with an average of 49. 3 years. Fractures were caused by fall ing in 19 cases, crash from high place in 1 case, traffic accident in 6 cases, and obtuse strike directly in 1 case, which were all closed fresh bone fractures. According to the standard of AO, all cases were classified as type C1 in 13 cases, type C2 in 11 cases, and type C3 in 3 cases. The palmar incl inination was from - 38° to 10°(mean - 12.2°); the ulnar deviation angle was from 6° to 30° (mean 19. 1°) before operations. The operations were performed from 1 to 3 days after injuries. The function of the carpal joints and the boneheal ing conditions were evaluated after operations. Results All cases were followed up for 4-24 months(mean 13. 1 months). No compl ications such as pin loosening, dislocation of fixators, injury of blood vessels and radial nerves, pin track infections occurred. According to Mcbride scoring, the results were excellent in 10 cases, good in 13 cases, fair in 3 cases and poor in 1 case, the excellent and good rate being 85. 2%. One case had traumatic arthritis and 1 case had wrist joint stiffness. All achieved fractures uniton 8-10 weeks (mean 9.3 weeks) after operations. The palmar incl inination angle was from 0° to 20° (mean 13. 4°); the ulnar deviation angle was from 10° to 33° (mean 22. 1°) after operations. Conclusion Treatment of unstable fractures of the distal radius by use of leverage reduction and bone graft with external fixator offers many advantages, such as simple operation, satisfactory reduction, rigid fixation, excellent function and lower incidence rate of traumatic arthritis.

    Release date:2016-09-01 09:10 Export PDF Favorites Scan
  • External Fixation or Intramedullary Nailing For Tibial Shaft Fractures in Adults: A Systematic Review

    Objective To determine the efficacy and safety of external fixation versus intramedulllary nailing in the treatment of adult tibial shaft fracture. Methods We searched the specialized trials register of The Cochrane Collaboration’s Bone, Joint and Muscule Trauma Group, The Cochrane Library (CENTRAL), MEDLINE (1966 to March 2006), EMBASE (1980 to March 2006) and PUBMED (1966 to March 2006). We also handsearched some Chinese orthopedic journals. Randomized controlled trials (RCTs) and quasi-randomized trials (quasi-RCTs) comparing external fixation versus intramedullary nailing for tibial shaft fractures in adults were included. The quality of these trials was critically assessed. We used the Cochrane Collaboration’s RevMan 4.2.8 for data analyses. Result Three RCTs and two quasi-RCTs involving a total of 279 patients were included. The results of meta-analyses showed that external fixation for tibial shaft fractures in adults may increase the infection rate [RR 2.45, 95%CI (1.31,4.61), P=0.005], and the malunion rate [RR 2.85, 95%CI (1.20,6.79), P=0.02] but may reduce the duration of hospitalization [RR –5.50, 95%CI (–6.99,–4.01)]. The nonunion rate, delayed healing rate, and healing time, were comparable between external fixation and intramedulllary nailing. Conclusion The trials available for this systematic review are too few and small for reliable estimates of the relative effects of external fixation and intramedulllary nailing. Further studies are needed to determine these effects , especially for patients who have GustiloШ C fractures.

    Release date:2016-08-25 03:35 Export PDF Favorites Scan
  • Modified internal fixator combined with sacroiliac screws in treatment of Tile C1.3 pelvic fracture

    Objective To investigate the effectiveness of modified internal fixator (INFIX) to fix the anterior pelvic ring for Tile C1.3 pelvic fracture by comparing with the traditional INFIX. MethodsThe patients with Tile C1.3 pelvic fractures admitted between April 2018 and June 2021 were taken as the study objects. Of them, 55 cases were included in the study according to the selection criteria. During operation, the anterior pelvic ring was fixed with the modified INFIX in 30 cases (modified group) and with the traditional INFIX in 25 cases (control group). The posterior pelvic ring in 55 cases was fixed with sacroiliac screws. There was no significant difference between the two groups in gender, age, cause of injury, time from injury to operation, and combined injury (P>0.05). The operation time, intraoperative blood loss, and complications were recorded and compared between the two groups. The X-ray film was taken to evaluate the reduction of the anterior pelvic ring after operation, grade the reduction according to the Matta scoring standards, and observe the fracture healing and healing time. The function was evaluated according to Majeed scoring standards during follow-up. Results The operation time of the modified group was significantly longer than that of the control group (Z=–3.837, P<0.001), but there was no significant difference in the intraoperative blood loss between the two groups (t=–1.831, P=0.076). All patients were followed up 12-18 months (mean, 14 months). X-ray film reexamination showed that the excellent and good rate of Matta scoring for anterior pelvic ring reduction in the modified group was 88.00%, which was significantly better than that in the control group (63.33%) (χ2=4.373, P=0.037). All fractures healed, and the fracture healing time of the modified group and the control group was (12.04±3.59) and (14.83±4.83) weeks respectively, with a significant difference (t=2.401, P=0.020). At last follow-up, the excellent and good rates of Majeed scoring were 80.00% in the modified group and 76.67% in the control group, with no significant difference (χ2=0.089, P=0.766). In the modified group, 2 cases (8%) had complications, all of which were incision infection above pubic symphysis. In the control group, 9 cases (30%) had complications, including 5 cases of lateral femoral cutaneous nerve injury, 2 cases of femoral nerve paralysis, and 2 cases of delayed fracture healing. The incidence of complications was significantly lower in the modified group than in the control group (χ2=4.125, P=0.042). ConclusionCompared with the traditional INFIX, the modified INFIX to fix the anterior pelvic ring for Tile C1.3 pelvic fracture has fewer complications, better stability, shorter fracture healing time, and lower risk of nerve injury.

    Release date:2023-01-10 08:44 Export PDF Favorites Scan
  • HINGED EXTERNAL FIXATOR WITH MINI-PLATE TO TREAT TERRIBLE TRIAD OF ELBOW

    Objective To investigate the effectiveness of hinged external fixator with mini-plate to treat terrible triad of the elbow. Methods Between August 2008 and June 2011, 11 patients with terrible triad of the elbow were treated with hinged external fixator combined with mini-plate. There were 9 males and 2 females, aged 22-56 years (mean, 34 years). The injuries were caused by falling from height in 8 cases and traffic accident in 3 cases. All patients were closed injury. The time from injury to operation varied from 8 hours to 7 days (mean, 3.7 days). According to Mason classification standard, all radial head fractures were type IV and complicated by posterior dislocation of the elbow; according to Regan-Morrey classification standard, ulna coronary process fractures were type I in 3 cases, type II in 3 cases, and type III in 5 cases. Results All the patients achieved primary healing of incision after operation and no nerve injury occurred. The patients were followed up 12-20 months (mean, 15 months). Two cases had screw channel infection after 12 weeks of operation, and 1 case had mild heterotopic ossification of the elbow after 4 months of operation. X-ray films showed that all fractures healed from 8 to 20 weeks (mean, 16 weeks). No recurrent dislocation or instability of the elbow occurred. At 12 months after operation, the elbow range of motion (ROM) were 120-145° (mean, 135°) in flexion, 0-25° (mean, 10°) in extension, 50-90° (mean, 70°) in pronation, and 50-80° (mean, 60°) in supination. According to Mayo elbow function evaluation standard, the results were excellent in 5 cases, good in 4 cases, and fair in 2 cases, with an excellent and good rate of 81.8%. Conclusion Hinged external fixator with mini-plate can enhance postoperative stability of the elbow. This therapy is beneficial to early functional exercise and obviously decrease the disability rate caused by complex damage on the elbow.

    Release date:2016-08-31 04:06 Export PDF Favorites Scan
3 pages Previous 1 2 3 Next

Format