west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "左心室辅助装置" 13 results
  • Perioperative renal function in patients undergoing heart transplantation versus left ventricular assist device implantation: A retrospective cohort study

    ObjectiveTo compare the perioperative renal function changes in patients undergoing heart transplantation (HT) and left ventricular assist device (LVAD) implantation. MethodsPatients with end-stage heart failure who underwent surgical treatment at Beijing Anzhen Hospital, Capital Medical University from January 2019 to April 2024 were included. According to the surgical method, patients were divided into a HT group and a LVAD group, and the estimated glomerular filtration rate (eGFR) of patients before surgery and postoperative 1, 7, 30, 60 days was compared between the two groups. The patients with preoperative renal dysfunction were subdivided into subgroups for comparison of eGFR changes before surgery and 30 days after surgery between the two groups. ResultsA total of 112 patients were enrolled. There were 78 patients in the HT group, including 61 males and 17 females, aged (44.42±18.51) years. There were 34 patients in the LVAD group, including 30 males and 4 females, aged (54.94±11.37) years. Compared with the HT group, the average age of patients in the LVAD group was greater (P<0.001), body mass index was higher (P=0.008), preoperative eGFR was lower (P=0.009), and the proportions of smokers (P=0.017), alcohol drinkers (P=0.041), and diabetes mellitus (P=0.028) patients were higher. Among patients with preoperative renal dysfunction [eGFR<90 mL/(min·1.73 m2)], compared with the HT group, the postoperative eGFR of the LVAD group was significantly higher than that of the HT group, and it was significantly increased compared with that before surgery; the postoperative eGFR of the HT group was comparable to that before surgery, and more than half of the patients had a lower eGFR than before surgery. Among patients with preoperative renal dysfunction, 11 patients in the HT group received continuous renal replacement therapy, and 8 died early; 2 patients in the LVAD group received continuous renal replacement therapy, and 1 died early. ConclusionFor end-stage heart failure patients with combined renal dysfunction, compared with HT, LVAD implantation enables patients to obtain better renal function benefits.

    Release date:2024-11-27 02:45 Export PDF Favorites Scan
  • Research progress on unplanned readmissions in patients with left ventricular assist devices

    The implantation of left ventricular assist device (LVAD) has significantly improved the quality of life for patients with end-stage heart failure. However, it is associated with the risk of complications, with unplanned readmissions gaining increasing attention. This article reviews the influencing factors, prediction methods and models, and intervention measures for unplanned readmissions in LVAD patients, aiming to provide scientific guidance for clinical practice, assist healthcare professionals in accurately assessing patients' conditions, and develop rational care plans.

    Release date:2025-05-30 08:48 Export PDF Favorites Scan
  • Current status and future perspectives of left ventricular assist devices

    The implantation of a left ventricular assist device (LVAD) is an important therapeutic tool for patients with end-stage heart failure, which can either help patients transit to the heart transplantation stage or serve as destination therapy until the end of their lives. In recent years, the third generation of LVAD has evolved rapidly and several brands have been marketed both domestically and internationally. The number of LVAD implantations has been increasing and the long-term survival rate of implanted patients has improved, so this device has a broad development perspective. This article summarizes the current status, usage standards and precautions, and common complications after implantation of LVAD, as well as looks forward to the future development of LVAD, hoping to be helpful for researchers who are new to this field.

    Release date:2024-11-27 02:45 Export PDF Favorites Scan
  • Study on regurgitation using the coupling model of left ventricular assist device and cardiovascular system

    Regurgitation is an abnormal condition happens when left ventricular assist devices (LVADs) operated at a low speed, which causes LVAD to fail to assist natural blood-pumping by heart and thus affects patients’ health. According to the degree of regurgitation, three LVAD’s regurgitation states were identified in this paper: no regurgitation, slight regurgitation and severe regurgitation. Regurgitation index (RI), which is presented based on the theory of dynamic closed cavity, is used to grade the regurgitation of LVAD. Numerical results showed that when patients are in exercising, resting and sleeping state, the critical speed between slight regurgitation and no regurgitation are 6 650 r/min, 7 000 r/min and 7 250 r/min, respectively, with corresponding RI of 0.401, 0.300 and 0.238, respectively. And the critical speed between slight regurgitation and severe regurgitation are 5 500 r/min, 6 000 r/min and 6 450 r/min, with corresponding RI of 0.488, 0.359 and 0.284 respectively. In addition, there is a negative relation correction between RI and rotational speed, so that grading the LVAD’s regurgitation can be achieved by determining the corresponding critical speed. Therefore, the detective parameter RI based on the signal of flow is proved to be able to grade LVAD’s regurgitation states effectively and contribute to the detection of LVAD’s regurgitation, which provides theoretical basis and technology support for developing a LVADs controlling system with high reliability.

    Release date:2017-10-23 02:15 Export PDF Favorites Scan
  • Application status and development of left ventricular assist devices in ischemic heart failure patients

    In China, more than half of heart failure patients are ischemic heart failure patients. And a large proportion of left ventricular assist device implantation patients are also ischemic heart failure patients. However, left ventricular assist device implantation in ischemic heart failure patients is facing with problems such as patient screening, coronary artery disease, small left ventricle, mitral insufficiency, and ventricular aneurysm. There are only a few retrospective studies with small sample sizes abroad trying to provide solutions to these problems. While there is a lack of systematic understanding of this issue in China. Therefore, we provide an overview of the application and progress of left ventricular assist devices in ischemic heart failure patients, aiming to help clinicians have a comprehensive understanding of this issue and provide some guidance.

    Release date:2024-11-27 02:45 Export PDF Favorites Scan
  • 左心室辅助装置患者行减重手术一例

    Release date:2024-06-24 02:56 Export PDF Favorites Scan
  • Study on sensorless suction detection method based on the intrinsic parameter of rotary left ventricular assist devices

    The rotary left ventricular assist device (LVAD) has been an effective option for end-stage heart failure. However, while clinically using the LVAD, patients are often at significant risk for ventricular collapse, called suction, mainly due to higher LVAD speeds required for adequate cardiac output. Some proposed suction detection algorithms required the external implantation of sensors, which were not reliable in long-term use due to baseline drift and short lifespan. Therefore, this study presents a new suction detection system only using the LVAD intrinsic blood pump parameter (pump speed) without using any external sensor. Three feature indices are derived from the pump speed and considered as the inputs to four different classifiers to classify the pumping states as no suction or suction. The in-silico results using a combined human circulatory system and LVAD model show that the proposed method can detect ventricular suction effectively, demonstrating that it has high classification accuracy, stability, and robustness. The proposed suction detection system could be an important part in the LVAD for detecting and avoiding suction, while at the same time making the LVAD meet the cardiac output demand for the patients. It could also provide theoretical basis and technology support for designing and optimizing the control system of the LVAD.

    Release date:2019-06-17 04:41 Export PDF Favorites Scan
  • Short- to medium-term safety and efficacy of the implantable Corheart 6 left ventricular assist system in patients with end-stage heart failure

    Objective To investigate the efficacy and safety of the Corheart 6 left ventricular assist system in patients with end-stage heart failure. Methods A retrospective study was conducted on patients with end-stage heart failure who were treated with Corheart 6 left ventricular assist system from March 2022 to June 2024 in 4 hospitals in Jiangsu Province. The efficacy of the device was evaluated by comparing changes in clinical indicators at preoperative, discharge, 3-month postoperative, and 6-month postoperative timepoints, including the New York Heart Association (NYHA) functional classification, left ventricular ejection fraction (LVEF), and left ventricular end-diastolic diameter (LVEDD). The safety of the device was assessed by analyzing the intraoperative position and orientation of the blood pump inlet cannula, as well as the incidence of adverse events. Results In this study, 39 patients were collected, including 34 males and 5 females with a mean age of (56.4±12.5) years, ranging from 20 to 75 years. There was no operative death. There was no death in postoperative 3 months with a survival rate of 100.0%. There were 3 deaths in 6 months postoperatively, with a survival rate of 92.3%. All patients had a preoperative NYHA cardiac function classification of class Ⅳ. The NYHA cardiac function class of the patients improved (P<0.05) at discharge, 3 and 6 months after surgery when compared to the preoperative period. LVEF was significantly higher at 3 months after surgery than that during the preoperative period (P<0.05). LVEDD was significantly smaller at discharge, 3 and 6 months after surgery than that during the preoperative period (P<0.05). The safety evaluation's findings demonstrated that all 39 patients' intraoperative blood pump inlet tubes were oriented correctly, the artificial blood vessel suture sites were appropriate, there were no instances of device malfunction or pump thrombosis, or instances of bleeding or hemolysis, and the rate of the remaining adverse events was low. Conclusion With a low rate of adverse events and an excellent safety profile, the Corheart 6 left ventricular assist system can efficiently enhance cardiac function in patients with end-stage heart failure. It also has considerable clinical uses.

    Release date:2025-04-28 02:31 Export PDF Favorites Scan
  • Early outcomes of domestic left ventricular assist device implantation with or without concomitant mitral valvuloplasty

    Objective To compare the early outcomes of domestic third-generation magnetically levitated left ventricular assist device (LVAD) with or without concomitant mitral valvuloplasty (MVP). Methods The clinical data of 17 end-stage heart failure patients who underwent LVAD implantation combined with preoperative moderate to severe mitral regurgitation in Fuwai Central China Cardiovascular Hospital from May 2018 to March 2023 were retrospectively analyzed. The patients were divided into a LVAD group and a LVAD+MVP group based on whether MVP was performed simultaneously, and early outcomes were compared between the two groups. Results There were 4 patients in the LVAD group, all males, aged (43.5±5.9) years, and 13 patients in the LVAD+MVP group, including 10 males and 3 females, aged (46.8±16.7) years. All the patients were successful in concomitant MVP without mitral reguragitation occurrence. Compared with the LVAD group, the LVAD+MVP group had a lower pulmonary artery systolic pressure and pulmonary artery mean pressure 72 h after operation, but the difference was not statistically different (P>0.05). Pulmonary artery systolic pressure was significantly lower 1 week after operation, as well as pulmonary artery systolic blood pressure and pulmonary artery mean pressure at 1 month after operation (P<0.01). There was no statistically significant difference in blood loss, operation time, cardiopulmonary bypass time, aortic cross-clamping time, mechanical ventilation time, or ICU stay time between the two groups (P>0.05). The differences in 1-month postoperative mortality, acute kidney injury, reoperation, gastrointestinal bleeding, and thrombosis and other complications between the two groups were not statistically significant (P>0.05). Conclusion Concomitant MVP with implantation of domestic third-generation magnetically levitated LVAD is safe and feasible, and concomitant MVP may improve postoperative hemodynamics without significantly increasing perioperative mortality and complication rates.

    Release date:2024-11-27 02:45 Export PDF Favorites Scan
  • Current status and progress of implantable left ventricular assist devices

    Implantable left ventricular assist device (LVAD) has become an essential treatment for end-stage heart failure, and its effect has been continuously improved. In the world, magnetic levitation LVAD has become mainstream and is increasingly used as a destination treatment. China has also entered the era of ventricular assist device. The continuous improvement of the ventricular assist device will further improve the treatment effect. This article reviews the current situation and development trend of LVAD treatment in China and abroad.

    Release date:2023-08-31 05:57 Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content