west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "建模" 27 results
  • Construction and Analysis of a Finite Element Model of Human L4-5 Lumbar Segment

    In the present study, a finite element model of L4-5 lumbar motion segment was established based on the CT images and a combination with image processing software, and the analysis of lumbar biomechanical characteristics was conducted on the proposed model according to different cases of flexion, extension, lateral bending and axial rotation. Firstly, the CT images of lumbar segment L4 to L5 from a healthy volunteer were selected for a three dimensional model establishment which was consisted of cortical bone, cancellous bone, posterior structure, annulus, nucleus pulposus, cartilage endplate, ligament and facet joint. The biomechanical analysis was then conducted according to different cases of flexion, extension, lateral bending and axial rotation. The results showed that the established finite element model of L4-5 lumbar segment was realistic and effective. The axial displacement of the proposed model was 0.23, 0.47, 0.76 and 1.02 mm, respectively under the pressure of 500, 1 000, 1 500 and 2 000 N, which was similar to the previous studies in vitro experiments and finite element analysis of other people under the same condition. The stress distribution of the lumbar spine and intervertebral disc accorded with the biomechanical properties of the lumbar spine under various conditions. The established finite element model has been proved to be effective in simulating the biomechanical properties of lumbar spine, and therefore laid a good foundation for the research of the implants of biomechanical properties of lumbar spine.

    Release date: Export PDF Favorites Scan
  • Equivalent modeling and evaluation of molars using point-contact higher kinematic pair based on occlusal dynamic analysis

    As a representative part of the oral system and masticatory robot system, the modeling method of the dental model is an important factor influencing the accuracy of the multi-body dynamic model. Taking the right first molars of the masticatory robot as the research object, an equivalent model, point-contact higher kinematic pair composed of v-shaped surface and sphere surface, was proposed. Firstly, the finite element method was used to analyze the occlusal dynamics of the original model in three static contact cases (intrusive contact, centric occlusion, and extrusive contact) and one dynamic chewing case, and the expected bite force was obtained. Secondly, the Hertz contact model was adopted to establish the analytical expression of the bite force of the equivalent model in three static contact cases. The normal vectors and contact stiffness in the expression were designed according to the expected bite force. Finally, the bite force performance of the equivalent model in three static contact cases and one dynamic chewing case was evaluated. The results showed that the equivalent model could achieve the equivalent bite force of 8 expected items in the static contact cases. Meanwhile, the bite force in the early and late stages of the dynamic chewing case coincides well with the original model. In the middle stage, a certain degree of impact is introduced, but it can be weakened by subsequent trajectory planning. The equivalent modeling scheme of the dental model proposed in this paper further improves the accuracy of the dynamic model of the multi-body system. It provides a new idea for the dynamic modeling of other complex human contacts.

    Release date:2020-10-20 05:56 Export PDF Favorites Scan
  • Study on modeling, simulation, and sensorless feedback control algorithm of the cavopulmonary assist device based on the subpulmonary ventricular exclusion

    The subpulmonary ventricular exclusion (Fontan) could effectively improve the living quality for the children patients with a functional single ventricle in clinical. However, postoperative Fontan circulation failure can easily occur, causing obvious limitations while clinically implementing Fontan. The cavopulmonary assist devices (CPAD) is currently an effective means to solve such limitations. Therefore, in this paper the in-silico and in-vitro experiment coupled model of Fontan circulation failure for the children patients with a single ventricle and CPAD is established to evaluate the effects of CPAD on the Fontan circulation failure. Then a sensorless feedback control algorithm is proposed to provide sufficient cardiac output and prevent vena caval suction due to CPAD constant pump speed. Based on the CPAD pump speed-an intrinsic parameter, the sensorless feedback control algorithm could accurately estimate the cavopulmonary pressure head (CPPH) using extended Kalman filter, eliminating the disadvantage for pressure sensors that cannot be used in long term. And a gain-scheduled, proportional integral (PI) controller is used to make the actual CPPH approach to the reference value. Results show that the CPAD could effectively increase physiological perfusion for the children patients and reduce the workload of a single ventricle, and the sensorless feedback control algorithm can effectively guarantee cardiac output and prevent suction. This study can provide theoretical basis and technical support for the design and optimization of CPAD, and has potential clinical application value.

    Release date:2021-08-16 04:59 Export PDF Favorites Scan
  • Dynamic Modeling and Simulating of Squatting-standing Action of Human Body

    It is very difficult for stroke patients to complete the action of squatting-standing because their equilibrium function ability has been seriously declined. It was necessary, therefore, to do a deep research on the action of human squatting-standing and to set up an accurate model and simulation. In our modeling research, the movements of upper limbs and head was neglected, and a seven-segment model was developed to establish the coordinate system of human squatting-standing action. It calculated the knee joint moment and hip joint moment during squatting and standing by utilizing Lagrange method, and then simulated this mathematical model by utilizing Matlab. Geometric model of human squatting-standing was developed and simulated in ADAMS which proved that the established Lagrange model was reasonable. It would also provide significant theoretical references for further study and development of squatting-standing rehabilitation training equipment.

    Release date: Export PDF Favorites Scan
  • Advances in digital twins technology of human skeletal muscle

    The human skeletal muscle drives skeletal movement through contraction. Embedding its functional information into the human morphological framework and constructing a digital twin of skeletal muscle for simulating physical and physiological functions of skeletal muscle are of great significance for the study of "virtual physiological humans". Based on relevant literature both domestically and internationally, this paper firstly summarizes the technical framework for constructing skeletal muscle digital twins, and then provides a review from five aspects including skeletal muscle digital twins modeling technology, skeletal muscle data collection technology, simulation analysis technology, simulation platform and human medical image database. On this basis, it is pointed out that further research is needed in areas such as skeletal muscle model generalization, accuracy improvement, and model coupling. The methods and means of constructing skeletal muscle digital twins summarized in the paper are expected to provide reference for researchers in this field, and the development direction pointed out can serve as the next focus of research.

    Release date: Export PDF Favorites Scan
  • 基于计算机辅助技术的伤口预测研究

    随着医疗技术信息化的发展,用计算机技术来辅助临床问题的处理也运用得越来越多。运用计算机辅助技术对伤口护理领域中有关伤口形状、色彩、边界的测量及愈合预测的问题及研究进展进行阐述,同时提出基于偏微分的伤口三维模型建立和基于纹理合成技术对肌成纤维细胞进行模拟的伤口愈合图像预测算法。伤口三维模型的建立和伤口愈合图像预测算法的模拟,不仅有助于临床伤口科研工作的进一步展开,促进医疗工作的信息化和数字化发展;还能实现预测工作,为医护工作者提供了一种新的影像学参考资料,同时有利于患者进一步的了解自己的病情。现就基于计算机辅助技术的伤口预测研究进展作一综述。

    Release date: Export PDF Favorites Scan
  • Development Method of Healthcare Information System Integration Based on Business Collaboration Model

    Integration of heterogeneous systems is the key to hospital information construction due to complexity of the healthcare environment. Currently, during the process of healthcare information system integration, people participating in integration project usually communicate by free-format document, which impairs the efficiency and adaptability of integration. A method utilizing business process model and notation (BPMN) to model integration requirement and automatically transforming it to executable integration configuration was proposed in this paper. Based on the method, a tool was developed to model integration requirement and transform it to integration configuration. In addition, an integration case in radiology scenario was used to verify the method.

    Release date:2021-06-24 10:16 Export PDF Favorites Scan
  • Ultrasound Simulation of Carotid Artery Plaque and System Implementation

    A method of ultrasonic simulation based on the FIELD II software platform for carotid artery plaque was proposed according to the analysis for geometrical shape, tissue characteristics and acoustic properties of carotid artery plaques in clinic, and then a simulation system was developed by using the MATLAB graphical user interface (GUI). In the simulation and development, a three-dimensional geometric model of blood vessel with plaques was set up by using the metaball implicit surface technique, and a tissue model was established based on the scatterers with spatial position of gamma random distribution. Comparison of the statistical and geometrical characteristics from simulated ultrasound B-mode images with those based on clinical ones and preset values, the results fully demonstrated the effectiveness of the simulation methods and system.

    Release date:2016-12-19 11:20 Export PDF Favorites Scan
  • Application and development trends of population pharmacokinetic techniques in virtual clinical trials

    Population pharmacokinetics is a research technique based on computer simulation and data analysis, and it has been employed to investigate the dynamic behavior of drug metabolism in different populations. This approach could address practical challenges such as prolonged clinical trial durations, high costs, and increased difficulty in traditional clinical trials. By comprehensively analyzing differences in the internal drug metabolism processes across populations with varying physiological and pathological conditions, population pharmacokinetics has emerged as an effective method to optimize drug development and clinical applications. This article provides a preliminary overview of the essence of population pharmacokinetics, its application in clinical trials, and potential future trends. We hope to serve as a reference and guidance for the application of new technologies and methods in clinical trials.

    Release date:2024-09-20 01:01 Export PDF Favorites Scan
  • Numerical Finite Element Modeling of Custom Car Seat Using Computer Aided Design

    A good cushion can not only provide the sitter with a high comfort, but also control the distribution of the hip pressure to reduce the incidence of diseases. The purpose of this study is to introduce a computer-aided design (CAD) modeling method of the buttocks-cushion using numerical finite element (FE) simulation to predict the pressure distribution on the buttocks-cushion interface. The buttock and the cushion model geometrics were acquired from a laser scanner, and the CAD software was used to create the solid model. The FE model of a true seated individual was developed using ANSYS software (ANSYS Inc, Canonsburg, PA). The model is divided into two parts, i.e. the cushion model made of foam and the buttock model represented by the pelvis covered with a soft tissue layer. Loading simulations consisted of imposing a vertical force of 520N on the pelvis, corresponding to the weight of the user upper extremity, and then solving iteratively the system.

    Release date: Export PDF Favorites Scan
3 pages Previous 1 2 3 Next

Format

Content