find Keyword "显微镜检查" 33 results
  • 23G微创玻璃体切割手术巩膜切口的超声生物显微镜观察

    Release date:2016-09-02 05:41 Export PDF Favorites Scan
  • 超声生物显微镜在睫状体及其相关疾病检查中的应用

    睫状体位于虹膜后,是常规眼科方法检查的ldquo;盲区rdquo;,由于它的隐蔽位置,使睫状体及其相关 疾病的临床检查和诊断十分困难。超声生物显微镜检查(ultrasound biomicroscopy,UBM)采用高频超声波作为检测能源,可穿过透明组织和非透明组织。因此,UBM不但能观察到虹膜表面的形态,还能观察到后房及虹膜后组织的情况,其令人满意的分辨力和清晰度,为临床检查睫状体的形态、位置以及病变提供了良好的工具。现对UBM在睫状体及其相关疾病检查中的应用及其临床意义作一综述。(中华眼底病杂志,2002,18:79-81)

    Release date:2016-09-02 06:01 Export PDF Favorites Scan
  • Application of UF100 Full-auto Urine Sediment Analyzer in Detecting Cylindruria

    【摘要】 目的 探讨全自动尿沉渣分析仪在尿管型检测中的应用。 方法 收集尿管型患者晨尿标本836份。所有标本均经尿干化学分析仪检测Pro≥1+或尿沉渣分析仪提示有管型。采用UF100全自动尿沉渣分析仪和显微镜检测管型,对比分析两者的检测结果。 结果 836份标本中,UF100全自动尿沉渣分析仪检测阳性者320例,占38.28%;显微镜检测阳性者195例,占23.33%。其中UF100全自动尿沉渣分析仪的假阳性率为26.52%,假阴性率为23.08%。UF100尿沉渣分析仪与显微镜检测管型的阳性结果比较,差异有统计学意义(Plt;0.01)。 结论 UF100全自动尿沉渣仪能快速筛检尿沉渣,但存在一定的假阴性,必须同时将其检测结果与尿干化学结果结合考虑以决定是否再进行显微镜检测,减少假阴性以防止漏检。【Abstract】 Objective To investigate the application of UF-100 full-auto urine sediment analyzer in detecting cylindruia. Methods 836 specimens with cylindruia were selected. All the specimens with Pro≥1+ were dectected by chemical dipstick or cylindruia by urine sediment analyzer. The cast were detected by urine sediment analyzer and microscope, and the results were compared. Results Of 836 specimens, 320 positive samples(38.28%) were found by UF-100 while 195 (23.33%) were found by microscope. False positive rate and false negative rate of UF100 were 26.52% and 23.08%. Compared the results of urine sediment analyzer with microscope, the difference was statistically significant (Plt;0.01). Conclusions UF100 can detect urinary cast quickly, but there is a little high false negative rate. So we should consider urine sample whether to be detected by microscope compared with results of UF100 and chemical dipstick.

    Release date:2016-09-08 09:50 Export PDF Favorites Scan
  • Schwartz-Matsuo综合征房水电子显微镜检查一例

    Release date:2016-11-25 01:11 Export PDF Favorites Scan
  • Analysis of the positive rate of scanning laser ophthalmoscope in the retromode for different types of diabetic macular edema

    Objective To explore the positive rate of scanning laser ophthalmoscope in the retromode (RM-SLO) in different types of diabetic macular edema (DME), and to analyze its correlation with foveal thickness (CMT) and macular volume. MethodsFrom March to May 2021, 40 patients (65 eyes) were diagnosed as DME by fundus examination combined with optical coherence tomography (OCT) in Affiliated Eye Hospital of Wenzhou Medical University at Hangzhou were included in the study. All eyes underwent best corrected visual acuity (BCVA), OCT and RM-SLO fundus imaging examinations, 47 eyes underwent fluorescein fundus angiography (FFA) examination. RM-SLO fundus imaging examinations were performed with Mirante SLO, including retro mode illumination deviated right (RMDR) and retro mode illumination deviated left (RMDL). If one or more of the RMDR and RMDL of the examined patient can identify macular edema, RM-SLO was considered to be able to identify macular edema. The macular volume at CMT and 6 mm from the fovea was measured by OCT software. DME were divided into 3 types based on OCT images: diffuse retinal thinkening (DRT) type; cystoid macular edema(CME) type; serous retinal detachment (SRD) type, focal leakage type, diffuse leakage type and diffuse cystic leakage type. The consistency of RMDR and RMDL in the diagnosis of DME in RM-SLO fundus imaging was evaluated, as well as their positive rate in different classifications of DME. The correlation between the detection of macular edema by RM-SLO and the DME type, CMT and foveal volume, and the correlation between BCVA and edema type, CMT and macular volume were analyzed. ResultsAmong 65 eyes, the positive rates of RMDR and RMDL fundus imaging to detect DME were 46 (70.77%, 46/65) and 48 (73.85%, 48/65), respectively. There was good consistency in identifying DME (Kappa value=0.770; P<0.001). The positive rates of RMDR and RMDL fundus imaging DRT, CME and SRD type of DME were 42.11% (8/19), 57.89% (11/19), 77.78% (28/36), 77.78% (28/36), 100.00% (10/10), 90.00% (9/10), respectively. In the FFA classification of them, the positive rates of focal leakage, diffuse leakage and diffuse cystic leakage were 68.75% (11/16), 62.50% (10/16), 68.00% (17/25), 76.00% (19/25), 100.00% (6/6), 100.00% (6/6), respectively. The results of Spearman correlation analysis showed that whether RM-SLO could identify DME was associated with CMT and OCT classification (r=0.310, 0.365; P=0.120, 0.003); there was no correlation between FFA classification and macular volume (r=0.113, 0.117; P=0.449, 0.352). BCVA was correlated with CMT and macular volume (r=0.307, 0.269; P=0.013, 0.030), however, there was no significant correlation with OCT type, angiographic type (r=0.051, 0.175; P=0.684, 0.240). ConclusionThe diagnostic agreement of DME are good between RMDR, RMDL of RM-SLO image. DME of DRT type and patients with smaller CMT in OCT are difficult to identified by RM-SLO fundus imaging.

    Release date:2022-12-16 10:13 Export PDF Favorites Scan
  • 硅油长期填充眼电子显微镜观察二例

    Release date:2016-09-02 05:58 Export PDF Favorites Scan
  • The anatomical investigation of foveal avascular area

    Objective To observe the dimensions of the capillary blood vessel arch in central fovea of macula and the foveal avascular area (FAZ), and their relationships with age.Methods Retina in macula of 32 cadavers eyes were isolated . Retinal vessels were immunostained by collagen type IV and examined by confocal laser scanning microscopy. The area and diameter of the FAZ were measured, and the relationship between FAZ and age was analysed. Results The parafoveolar capillary network was observed clearly by confocal laser scanning microscopy. The average area of the FAZ was (0.24±0.13) mm2, and the average diameter was (0.54±0.15) mm. The area and diameter of the FAZ did not show any correlation with age.Conclusions The parafoveolar capillary network could be observed by confocal laser scanning microscopy. The size of the FAZ does not change with age. The dimensions of the parafoveolar capillary network may not be influenced by age. (Chin J Ocul Fundus Dis,2003,19:73-75)

    Release date:2016-09-02 06:00 Export PDF Favorites Scan
  • B-scan ultrasonic and ultrasound biomicroscopic imaging of retinal detachment

    Purpose To verify the effectiveness of combined B-scan ultrasonoscopy and ultrasound biomicroscopy(UBM)imagings in diagnosis of retinal detachments. Methods To contrast the manifestations in vitrectomy operations with the findings of preoperative combined B-scan ultrasonic and UBM examinations in 25 eyes of 25 cases in which 18 eyes with rhegmatogenous retinal detachment and 7 eyes with traumatic retinal detachment were included. Results B-scan ultrasonic imagings were divided into four types: type C,type V,type upsilon; and type gamma;,which included 6 eyes,2 eyes,4 eyes and 11 eyes respectively,and from type C to type gamma;,the retinal detachments manifested themselves from simple posterior segment proliferative vitreoretinopathy(PVR)to both anterior and posterior PVR.The imagings of UBM were divided into 3 types:shallow retinal detachment,retinal circumferential contraction and retinal anterior displacement,which reflected the degree of anterior PVR from lightness to severeness. Conclusions The technique of combined B-scan ultrasonoscopy and UBM can be used to access the severity of the retinal detachments,hence would be beneficial in diagnosing anterior and posterior PVR,designing the surgical precedures and assessing the prognosis. (Chin J Ocul Fundus Dis,1998,14:16-20)

    Release date:2016-09-02 06:11 Export PDF Favorites Scan
  • Study on the ultrastructural characteristic of segments of photoreceptors from retinas of neonatal calf

    Objective To study on the ultrastructural characteristic of segments of photoreceptors from neonatal retinas for supporting donor retina choice of retinal transplantation. Methods Photoreceptors from neonatal calf and adult calf were analysed by scanning electron microscopy and transmission electron microscopy. Results Segments of photoreceptors from neonatal calf appeared the mushroom pattern, in which, distal end of outer segment which was ball-shaped formed the head with mushrooms appearance, and the inner segments along with some of outer segments formed the body with mushrooms appearance. Within the outer segment, plasma membranes of adjacent evaginations form a disk subsequently. The a rray of most disks were vertical to the entire length of segments, but some were parallel and slope to.Owing to the incomplete formation, some rim of disk near distal end of outer segment revealed step-shaped appearance. The distal end of outer segment displays some processes consisted of membranous discs, much vesicular material and mitochondria, much rough endoplasmic reticulum (RER) and numerous polyso mes.Segments of photoreceptor connected with outer nuclear layer via the external limiting membrane. Conclusion The typical morphol ogical structures of outer segments suggest the immature and b gowth ability of photoreceptors of the retina of neonatal calf, and therefore the competence for donor material of retinal transplantation. (Chin J Ocul Fundus Dis, 2001,227-229)

    Release date:2016-09-02 06:03 Export PDF Favorites Scan
  • 柔红霉素引发培养的人视网膜色素上皮细胞凋亡的透射电镜观察

    Release date:2016-09-02 06:11 Export PDF Favorites Scan