The body is at a hypo-coagulation status after the heart mechanic valve prosthesis replacement operation, and the incidence of anticoagulation complications is rather high because of that administration of warfarin may result in “anticoagulation vacuum” at an early stage. Moreover, the necessary application of other anticoagulation methods assisting the employment of warfarin have still not been scientifically normalized. Blood coagulation factor Ⅱ,Ⅶ, prothrombin fragment1+2 (F1+2 ), urine fibrimopeptide A (UFPA) , and International Normalized Ratio(INR), could exactly reflect the anticoagulation intensity 48-72 hours after the replacement operation,reasonable use of anticoagulant therapy as well as accurate and in-time monitoring methods is significant to reduce complications,elevate survival rate, and improve quality of life.
ObjectiveTo investigate the influence of mechanical and biological valves on clinical benefits of elderly patients with valvular heart disease.MethodsWe retrospectively analyzed the clinical data of 280 elderly patients with valvular heart disease treated by valve replacement between 2008 and 2014 year. The patients were divided into two groups by tendency score matching including a group A with biological valves and a group B with mechanical valves. Finally, there were 96 patients in each group. There were 43 males and 53 females at age of 64.41±6.52 years in the group A, 44 males and 52 females at age of 64.07±6.20 years in the group B.ResultsThe bleeding rate of skin and mucosa of the group B was significantly higher than that of the group A (P<0.05). There was no statistical difference in mortality within 30 days after operation, all-cause mortality, re-hospitalization rate, re-valve replacement rate, combined atrial flutter/atrial fibrillation ratio, drug use, incidence of cerebral infarction, cerebral hemorrhage, new peripheral vascular embolism and visceral hemorrhage, heart function (NYHA) classification, the cumulative survival rate of all the patients during follow-up (P=0.63), or the cumulative survival rate of the patients with no thrombus/hemorrhage (P=0.75) between the two groups (P>0.05).ConclusionMechanical valve replacement and bioprosthetic valve replacement in the treatment of valvular heart disease in the elderly can achieve similar clinical benefits and both have clinical application value.
ObjectiveTo describe the status of quality of life (QOL) and self-management behavior in patients following mechanical heart valve replacement, and explore the relationship between QOL and self-management behavior. MethodsConvenient sampling was used to recruit 352 patients following mechanical heart valve replacement in a high-level hospital in Chengdu between January 2011 and June 2012. General information questionnaire, MOS SF-36 scales, and self-management behavior questionnaire were used to collect data. T-test was used to analyze the difference between patients and normal people. And correlation analysis was used to see the correlation between QOL and self-management. ResultsFor MOS SF-36 scale results in patients within one year after surgery, physical functioning (PF) score was 73.44±15.11, role-physical (RP) was 49.52±39.17, body pain (BP) was 63.13±17.93, general health (GH) was 58.85±14.88, vitality (VT) was 63.54±18.10, social functioning (SF) was 76.67±17.40, role-emotional (RE) was 64.96±41.37, and mental health (MH) was 72.76±17.40. All these scores of the patients were significantly lower than the norm of Sichuan Province (P<0.05) except the dimension of mental health. For patients one year or more after surgery, PF score was 76.53±14.41, RP 58.44±39.21, BP 68.16±18.26, GH 61.39±13.57, VT 68.47±16.37, SF 79.79±19.34, RE 72.94±37.29, and MH 75.87±14.70, among which PF, RE, BP and GH scores were lower than the norm (P<0.05). The average total score of self-management behavior was 143.21±20.63. QOL and self-management behavior were positively correlated. ConclusionThere is still a gap between patients following mechanical heart valve replacement and normal people in terms of quality of life. Patients' self-management behavior is positively correlated with the quality of life. Good self-management behavior contributes to the improvement of QOL.
Clinical application history of prosthetic heart valves has been over five decades, and mechanical heart valves have satisfactory clinical outcomes for surgical treatment of valvular heart disease. The development history of mechanical heart valves experienced from the first generation of ball valves and caged disc valves to the second generation of single tilting disc valve, and to the third generation of bileaflet valves. In 1960, ball valve was first used for heart valve replacement in abroad. In 1963, China-made ball valve was also produced and used in clinical practice. In 1969, the second generation of single tilting disc valve was developed in abroad. In 1978, China-made single tilting disc valve was produced and widely used in clinical practice with satisfactory clinical outcomes. Since 1980 when it was first produced, bileaflet valve has taken the place of above 2 types of valves for its excellent performance, and become the mainstream product all over the world. Currently, the development of China-made bileaflet valves has lagged behind, and domestic mechanical heart valve market has almost been monopolized by foreign bileaflet valve products. Therefore, the development of ideal China-made mechanical heart valve deserves further research.
The management of women with mechanical heart valves during pregnancy remains difficult and controversial. The selection of prosthetic heart valve, management during pregnancy and delivery period, guidelines and anticoagulation strategy used in patients with a mechanical heart valve in China are summarized in this review.
ObjectiveTo explore optimal intensity of oral anticoagulation for patients with prosthetic heart valves in Northeast China. MethodsA total of 856 patients in Northeast China who underwent prosthetic heart valve replacement in the Department of Cardiovascular Surgery,Second Hospital of Jilin University from January 2005 to June 2013 were enrolled in this study. There were 406 male and 450 female patients with their age of 45.2±13.3 years. All the patients received low-intensity oral anticoagulation [international normalized ratio (INR) 1.5-2.2,aortic valve replacement (AVR):1.5-1.8,mitral valve replacement (MVR):1.8-2.2]. Patients were followed up after discharge,and the incidence of anticoagulation-related complications was summarized. ResultsThese patients were followed up for 1-78 (18.3±12.2) months,and the follow-up rate was 75.4%. Twelve patients (1.86%) had thromboembolic complications and 10 patients (1.55%) had hemorrhagic complications. Average warfarin dosage was 3.4±0.8 mg/day,and average INR was 1.94±0.54 during follow-up. ConclusionFor patients with prosthetic heart valves in Northeast China,low-intensity anticoagulation can produce satisfactory clinical outcomes to reduce the incidence of anticoagulation-related thromboembolic or hemorrhagic complications.
ObjectiveTo compare the outcomes of mechanical prosthetic versus bioprosthetic replacement of tricuspid valve. Methods We retrospectively analyzed the clinical data of 344 patients underwent tricuspid valve replacement (TVR) in Guangdong General Hospital between January 2000 and December 2010. There were 227 female and 117 male patients with their age of 8-74 (42.0±13.3) years. We allocated the patients into two groups: 168 patients (48.8%) at age of 37.0±11.6 years underwent mechanical tricuspid valve replacement (the MTVR group) and 176 (51.2%) patients at age of 46.0±13.4 years underwent biological tricuspid valve replacement (the BTVR group). Follow-up data were obtained via patients' visiting the outpatient clinic, telephone or mail contacts. ResultsThe mean follow-up time was 5.7 years (ranged from 2 months to 12.6 years). In the BTVR group, 149 patients survived to discharge from hospital, and 144 patients were followed-up successfully, giving a 96.6% follow-up rate. Early mortality (within 30 days post-operation) occurred in 29 patients (16.5%), and 14 patients (7.9%) died after 30 days post-operation. Eighteen bioprosthetic valve degeneration was found during follow-up, and infective endocarditis in 3 patients. In the MTVR group, 152 patients survived to discharge from hospital, 142 patients (93.4%) were followed-up. Early mortality in 13 patients (7.7%), and 14 patients (8.3%) died after 30 days post-operation. Nineteen patients suffered from mechanical prosthesis obstruction, no infective endocarditis patients was found in the MTVR group. There was no statistical difference between the BTVR group and the MTVR group in mortality rate (24.4% versus 16.1%, P=0.054) and in reoperation rate (4.2% versus 9.9%, P=0.051), respectively.There were statistical differences in long-term survival rates between the BTVR group and the MTVR group with 1 year survival rate(78% vs. 89%), 5 years survival rate(74% vs. 86%), and 10 years survival rate (66% versus 78%) with P value at 0.003. ConclusionsThis study suggests that the type of implanted prosthesis in tricuspid replacement does not affect long-term outcomes or the reoperation rate. The survival rate is higher in the MTVR group than that in the BTVR group, which may contribute to younger age in the MTVR group. There is a tendency in higher infective endocarditis incidence in the BTVR group than that in the MTVR group.
Objective Influence factors of the stable warfarin dose in the early period after mechanical prosthetic valve replacement were analyzed to guide the anticoagulation therapy for these patients. Methods A total of 288 patients within 6 months after mechanical prosthetic valve replacement in West China Hospital were followed up and registered at outpatient department from July 2012 to April 2014, including basic information (name, sex, age, height, weight, etc.), general clinical data (cardiac function, heart rate, surgery pattern, etc.) and related data about anticoagulation therapy. The target international standardized ratio (INR) range was 1.60 to 2.20 and the acceptable INR was 1.50 to 2.30. The sex, age, height, body weight, body mass index (BMI), body surface area (BSA) and related clinical factors were analyzed to find the relationship with the dose of warfarin. Results Sex was found to have a significant effect on the stable warfarin dose (P<0.05). Women needed a lower stable warfarin dose than men during the early anticoagulation therapy. There was no significant difference in the stable warfarin dose of patients with different ages, rhythms, NYHA classification, surgery pattern and diseases before operation; but the stable warfarin dose was lower in the patients with radiofrequency ablation during valve replacement procedures than the patients with single valve replacement (P<0.05). There was an association between age, height, weight, BMI, BSA and the stable warfarin dose withR2 of 1.2%, 3.2%, 3.5%, 1.1%, 4.2%, respectively and they could explain 6.1% of variability in warfarin dose. Conclusion During early anticoagulation therapy in patients with mechanical prosthetic valve replacement, it is necessary to consider the effects of various preoperative factors, drug factors and demographic factors on warfarin dose. Even though there is an association between age, height, weight, BMI, BSA and the stable warfarin dose, which can only explain 6.1% of variability in warfarin dose, thus cannot guide the postoperative anticoagulation of these patients.
ObjectiveTo explore the therapeutic effects of different surgical strategies on women with mechanical valve dysfunction during pregnancy.MethodsA total of 11 patients with mechanical valve dysfunction during pregnancy who underwent surgeries in our hospital from 2007 to 2017 were retrospectively included. The average age was 27.5±3.7 years. The prognosis of patients was analyzed according to the gestational weeks, cardiac function and the severity of mechanical valve dysfunction.ResultsNo death occurred. Three of them suffered subtotal hysterectomy during the surgery because of uncontrolled bleeding, and the others recovered without complications. Among the 5 patients with pregnancies <28 weeks, 1 patient was found intrauterine death before hospital admission, 2 suffered fetal loss 5 days after the cardiac surgery, and the other 2 patients continued their gestations until deliveries. Among the other 6 patients with pregnancies >28 weeks, 1 fetus died because of intracranial hemorrhage, and the other 5 survived without embryopathy or foetopathy.ConclusionGestation week, cardiac function and severity of mechanical valve dysfunction may be taken into account when making a treatment regimen for women with dysfunctional valve prostheses during pregnancy.
Objective To explore the evolving strategies and compare perioperative and long-term outcomes of tricuspid valve replacement (TVR) in recent 20 years in our hospital.MethodsBetween 1998 and 2018, the clinical data of 608 patients who underwent TVR at the Department of Cardiac Surgery, Guangdong Provincial People’s Hospital were retrospectively analyzed. There were 201 males and 407 females, with a median age of 47.0 (36.0, 57.0) years. Patients were divided into a biological tricuspid valve (BTV, n=427) group and a mechanical tricuspid valve (MTV, n=181) group. Propensity score matching was used to balance the baseline difference. Surgical strategy evolving, postoperative and long-term outcomes were analyzed between the two groups.ResultsSince 2008, the usage ratio of biological valves was significantly higher than that of mechanical valves. Seventy-nine (13.0%) patients died in hospital after TVR. Before propensity score matching, the postoperative mortality of the BTV group was higher than that of the MTV group (15.2% vs. 7.7%, P=0.012), and there was no statistical difference between the two groups after matching (10.4% vs. 7.2%, P=0.372). The duration of postoperative ventilator support in the BTV group was longer than that in the MTV group [22.0 (15.0, 37.0) h vs. 19.0 (11.0, 27.0) h, P=0.003], and the incidence of postoperative dialysis and re-thoracotomy exploring for bleeding was higher in the BTV group (8.9 % vs. 2.8%, 9.4% vs. 6.6%, respectively). However, there was no statistical difference in mortality after matching. The median follow-up time of discharged patients was 101.0 (65.0, 147.0) months, ranged from 1 to 265 months, and the follow-up rate was 82.2%. During the follow-up period, there were 101 deaths (19.1%) of whom 68 were from the BTV group and 33 from the MTV group. The survival rates at 1 year, 5 years, 10 years, 15 years and 20 years of all patients were 85.0% (95%CI 82.2-87.9), 78.9% (95%CI 75.7-82.4), 71.1% (95%CI 67.3-75.3), 59.7% (95%CI 54.2-65.6) and 51.7% (95%CI 43.3-60.7), and there was no statistical difference between the two groups after matching (P=0.46). The median time of tricuspid valve failure was 84.0 (54.0-111.0) months.ConclusionTVR is associated with high perioperative risks. There is no statistical difference in early mortality and long-term survival between biological and mechanical valve, while patients with mechanical valve has higher risk of re-operation for valve failure. Therefore, the type of prosthetic valve can be selected according to the patients' age, physical condition and the doctors’ experience.