west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "桡骨远端" 35 results
  • 掌侧锁定加压钢板治疗老年桡骨远端关节内骨折

    【摘 要】 目的 总结锁定加压钢板(locking compression plate,LCP)切开复位内固定治疗老年桡骨远端关节内骨折的初步效果。 方法 2004 年1 月- 2007 年2 月,收治22 例老年桡骨远端关节内骨折患者。男12 例,女10 例;年龄61 ~ 75 岁。跌伤14 例,交通伤8 例。根据AO 标准分型:B1 型3 例,B2 型7 例,C1 型7 例,C2 型4 例,C3 型1 例。伤后4 h ~ 15 d 手术。手术行掌侧入路骨折切开复位、LCP 内固定治疗。术后3 个月患者均服用钙剂治疗骨质疏松。 结 果 术后患者均获随访8 ~ 18 个月,平均15 个月。X 线片示骨折均于术后10 ~ 15 周达临床愈合,平均12 周。根据X 线片测量,尺偏角平均20.8°;掌倾角平均8.5°;桡骨短缩≤ 2 mm 21 例,≥ 2 mm 1 例;关节面塌陷、移位均矫正至 ≤ 1 mm。根据改良Mcbride 腕关节功能评价标准:获优16 例,良5 例,可1 例,优良率95.5%。 结论 采用掌侧入路骨折切开复位、LCP 内固定是治疗老年桡骨远端关节内骨折的一种有效方法。

    Release date:2016-09-01 09:12 Export PDF Favorites Scan
  • 桡骨远端骨折合并腕部尺神经损伤六例分析

    目的 总结桡骨远端骨折合并尺神经损伤的临床特点、治疗方法及预后。 方法 分析2002 年8 月- 2008 年8 月收治的6 例合并尺神经损伤的桡骨远端骨折患者临床资料。男4 例,女2 例;年龄21 ~ 55 岁,平均39岁。新鲜骨折4 例,其中开放骨折1 例;陈旧性骨折2 例。骨折类型按国际内固定研究学会(AO/ASIF)分型:A3 型2 例,B2、B3、C2、C3 型各1 例。6 例均有尺神经卡压和损伤表现。受伤至治疗时间3 h ~ 3.5 个月。分别给予切开复位钢板螺钉内固定、切开复位克氏针内固定加外固定架固定、闭合复位外固定架固定治疗。 结果 术后6 例均获随访,随访时间12 ~ 24 个月,平均18 个月。按中华医学会手外科学会上肢部分功能评定试用标准评定,获优5 例,可1 例。术后X 线片显示骨折对位良好,术后4 ~ 5 个月桡骨远端骨折均骨性愈合。随访期间无内固定物松动及骨折移位等并发症发生。除1 例陈旧性骨折手内在肌萎缩、运动功能恢复不明显外,余5 例尺神经感觉、运动功能均恢复较理想,爪形手畸形消失。 结论 合并尺神经损伤的桡骨远端骨折,开放手术时应行尺神经探查减压术,如未行探查手术应密切观察其病情变化。

    Release date:2016-08-31 05:47 Export PDF Favorites Scan
  • EFFECTIVENESS COMPARISON OF EXTERNAL FIXATION AND VOLAR LOCKING COMPRESSION PLATE IN TREATMENT OF DISTAL RADIUS FRACTURES OF TYPE C

    ObjectiveTo compare the effectiveness of external fixation and volar locking compression plate in the treatment of distal radius fractures of type C. MethodsBetween March 2012 and March 2013, 122 patients with distal radius fractures of type C were enrolled in the prospective randomized study. Fractures were treated by external fixation in 61 patients (external fixation group) and by open reduction and internal fixation using a volar locking compression plate in 61 patients (plate group). There was no significant difference in age, gender, fracture side, weight, height, body mass index, fracture type, and interval of injury and operation between 2 groups (P>0.05). The blood loss, operation time, hospitalization days, fracture union time, wrist function, and complications were compared between 2 groups. And the quality of reduction was observed, including volar tilting angle, ulnar deviation, radial height, and articular reduction. ResultsThe blood loss, operation time, and hospitalization days in plate group were significantly higher than those in external fixation group (P<0.05). All of the patients in both groups were followed up 12-28 months. Postoperative complications occurred in 4 patients (6.6%) of external fixation group (pin tract infection in 2 cases and radial nerve neuritis in 2 cases) and in 5 patients (8.2%) of plate group (wound infection in 1 case, carpal tunnel syndrome in 2 cases, and tendon rupture in 2 cases), showing no significant difference between 2 groups (P=0.500). The X-ray films showed fracture healing in all patients of 2 groups; the union time of plate group was significantly longer than that of external fixation group (P<0.05). At last follow-up, there was no significant difference in ulnar deviation and radial height between 2 groups (P>0.05), but the volar tilting angle of plate group was significantly larger than that of external fixation group (P<0.05). There was no significant difference in wrist function and articular reduction between 2 groups (P>0.05). ConclusionFor distal radius fractures of type C, the use of external fixation or volar locking compression plate can obtain satisfactory clinical outcomes, but the external fixation has the advantages of less invasion, shorter hospitalization days, minor complications, and faster fracture union.

    Release date: Export PDF Favorites Scan
  • 腓骨近端游离移植重建桡骨远端骨巨细胞瘤切除后骨缺损

    【摘 要】 目的 总结桡骨远端骨巨细胞瘤(giant cell tumor,GCT)切除后自体腓骨近端游离移植修复重建方法及效果。 方法 1997 年3 月- 2005 年3 月,对7 例桡骨远端GCT 患者行瘤段切除、自体腓骨近端游离移植修复重建术,其中男2 例,女5 例;年龄31 ~ 55 岁。术前腕关节平均活动度:掌屈37°,背伸30°,桡偏9°,尺偏15°;前臂旋前58°,旋后61°。影像学检查示肿瘤范围为4 cm × 3 cm × 3 cm ~ 8 cm × 6 cm × 4 cm。按改良Campanacci 影像学分级系统对GCT 进行分级,Ⅱ级5 例,Ⅲ级2 例。病理骨折3 例,所有患者桡骨远端骨质破坏均超过50% 。 结果 术后7 例患者均获随访,随访时间6 ~ 48 个月,平均16 个月。未发现肿瘤局部复发和远处转移,术后无感染、骨吸收和骨不愈合。移植腓骨全部成活,骨愈合时间10 ~ 14 周。重建腕关节外观及功能良好,腕关节平均活动度:掌屈40°,背伸36°,桡偏14°,尺偏20°,前臂旋前52°,旋后48°。根据肌肉骨骼肿瘤学会保肢评分标准进行功能评价,本组优3 例,良3 例,可1 例。 结 论 腓骨近端游离移植对桡骨远端肿瘤切除后骨缺损的重建是一良好的选择,远期效果尚待进一步观察。

    Release date:2016-09-01 09:14 Export PDF Favorites Scan
  • Ilizarov technique for treatment of distal radius deformity and bone defect after trauma

    ObjectiveTo investigate the effectiveness on the distal radius deformity and bone defect after trauma by using Ilizarov external fixator.MethodsThe clinical data of 9 patients of post-traumatic distal radius deformity with bone defect treated by Ilizarov technique between January 2012 and December 2016 were retrospectively analyzed. There were 7 males and 2 females with an average age of 25.6 years (range, 11-46 years). Of the 9 cases, 4 were radial baseball hand deformity with large bone defect, 4 were short deformity of distal radius, 1 was distal radius deformity with radial deflection and pronation deformity, all with distal dislocation of the distant radial-ulnar joint. The time from injury to operation was 6 months to 6.2 years (mean, 1.5 years). The bone defect was 1.4-6.8 cm (mean, 3.6 cm). After complete debridement, the forearm was fixed with Ilizarov external fixator. At 7 days after operation, bone transport or bone lengthening was performed at the rate of 0.8-1 mm/d, 4 times a day, the deformity was slowly corrected and the bone defect was repaired. According to the loss of palmar tilt angle and ulnar tilt angle measured before operation, the position of distal radial articular surface was gradually adjusted in the course of moving or prolonging, so as to restore palmar tilt angle and ulnar tilt angle as far as possible.ResultsAll wounds healed by first intention and no leakage or rupture occurred. All the 9 patients were followed up 15-36 months (mean, 23 months). All the radius defects healed and the distal deformity was corrected, the healing time was 92.4-138.6 days (mean, 104.7 days); the external fixation index was 32.6-51.1 days/cm (mean, 40.2 days/cm). After 2 months of external fixator removal, the wrist joint flexion was (42.6±3.1)°, the wrist dorsum extension was (48.5±4.7)°, the palm inclination angle was (11.5±1.3)°, and the ulnar deviation angle was (21.2±3.7)°; the elbow flexion was (128.2±6.4)°, the elbow extension was (3.2±2.1)°, the forearm pronation was (71.5±4.3)°, and the forearm rotation was (38.2±6.5)°; the wrist and elbow joint extension and forearm rotation were significantly improved when compared with preoperative values (P<0.05). At last follow-up, wrist function was assessed according to Gartland-Werley standard, the results were excellent in 3 cases, good in 5 cases, and fair in 1 case. Four cases had pinhole infection, and were cured after anti inflammatory dressing change or replacement of needles; 3 cases did not heal at the bone junction, and were healed after bone grafting; 4 cases deviated from the radial force line, and the deformity was corrected after adjusting the needle.ConclusionIlizarov technique can correct deformity and reconstruct bone defect of the post-traumatic distal radius simultaneously, so it is a good method to treat this kind of disease.

    Release date:2018-10-09 10:34 Export PDF Favorites Scan
  • T 型钢板支撑植骨在桡骨远端塌陷粉碎性骨折中的应用

    【摘 要】 目的 总结桡骨远端塌陷粉碎性骨折采用T 型钢板内固定、支撑植骨联合石膏外固定的治疗效果。 方 法 1999 年1 月- 2006 年7 月,采用切开复位、T 型钢板内固定、支撑植骨联合石膏外固定治疗38 例桡骨远端塌陷粉碎性骨折患者。男24 例,女14 例;年龄20 ~ 74 岁,平均41 岁。闭合骨折30 例,开放骨折8 例。陈旧性骨折11例,新鲜骨折27 例。根据AO 分型:C2 型18 例,C3 型20 例。尺偏角- 13 ~ 17°。29 例Colles 骨折掌倾角平均- 45.2°;与健侧比较,桡骨纵轴掌侧平均短缩4.5 mm;背侧平均短缩8.2 mm。9 例Smith 骨折掌倾角平均27.6°,掌侧平均短缩6.5 mm,背侧平均短缩5.1 mm。 结果 患者均获随访,随访时间9 ~ 20 个月,平均13 个月。无钢板断裂和医源性神经血管损伤。X 线片示骨折于术后5 ~ 9 周愈合,平均 7 周。桡骨纵轴长度恢复(与健侧比较),关节面平整;尺偏角16 ~ 24°,平均21.2°;掌倾角7 ~ 16°,平均10.6°。根据Dienst 等功能评估表进行评定,优24 例,良14 例。 结论 T 型钢板内固定、支撑植骨联合石膏外固定治疗桡骨远端塌陷粉碎性骨折,可有效恢复桡骨远端解剖结构、功能及良好外形。

    Release date:2016-09-01 09:14 Export PDF Favorites Scan
  • TREATMENT OF DISTAL RADIUS FRACTURE BY COMBINATION OF EXTERNAL FIXATOR AND VOLAR APPROACH FIXATION

    Objective To investigate the operative indication and clinical efficacy of combination of external fixator and volar approach fixation in treatingdistal radius fracture. Methods From March 2000 to March 2005, 28 patients with distal radius fracture were treated with combination of external fixator and volar approach fixation. Dorsal external fixator was used to maintain wrist in functional position, combinated volar plate or Kirschner wire fixation after reduction was achieved. Bone graft was necessary if there were severe comminuted cortical bone or compress of cancellous bone. Of 28 patients, there were 21 males and 7 females, aging from 1854 years with a median age of 41 years. The locations were the left side in 4 cases and the right side in 24 cases. According to typing criterion for AO, 18 cases were classified as C2 and 10 cases as C3. One case wasaccompanied with dislocation of lunate bone. Results Among 28 patients, 24 were followed up for an average of 8.5 months. The anatomical relationship of their wristjoint were reestablished and retained. Overall good to excellent results were achieved in 87%, excellent in 16 cases, good in 5 cases and fair in 3 cases. Conclusion A combination of external fixator and volar approach fixation is an effective method of treating fractures of the distal radius,because distal radius fracture is unstable or difficult to close reduction. Volarfixation can avoid operative complication, and external fixator can obtain satisfactory reduction and function.

    Release date:2016-09-01 09:22 Export PDF Favorites Scan
  • TREATMENT OF INTRA-ARTICULAR FRACTURE OF DISTAL RADIUS WITH T-SHAPED PLATE INTERNAL FIXATION.

    Objective To evaluate the effects of T-shaped plate internal fixation in treatment of intra-articular fracture of distal radius. Methods From January 2005 to March 2008, 52 cases of intra-articular fracture of distal radius were treated, including 32 males and 20 females and aging 21-60 years old (mean 47 years old). Fracture was caused by tumbl ing in 30 cases, by fall ing from height in 8 cases, by traffic accident in 11 cases, and by a crashing object in 3 cases. Of 52 cases,there were 50 cases of closed fracture and 2 cases of open fracture. According to AO standard of classification, there were 14 cases of B2 type, 16 cases of B3 type, 15 cases of C1 type, 6 cases of C2 type, and 1 case of C3 type. According to the Cooney’ s general standard of classification of unstable fracture, there were 5 cases of type II, 10 cases of type III, and 37 cases of type IV. The time from injury to operation was 3-14 days (mean 5 days). All patitents received open reduction and T-shaped plate fixation. Seven patients having bone defect were given 6-15 g autologous il ium or 5 mL calcium sulphate artificial aggregate after reduction. Results All incisions healed by first intention. All the patients were followed up for 15 to 30 months postoperatively (mean 24 months). The X-ray films showed good anatomical reduction, even articular surface and no lossening of internal fixation in all the cases. The fractures healed within 9-15 weeks after operation (mean 12 weeks). At last follow-up, the mean palmar tilt was 8° and the mean ulnar variance was 21°, showing statistically significant differences when compared preoperation (— 5° and 5°, P lt; 0.05). The radial length were not abbreviated. According to Dienst assessment, the results were excellent in 42 cases, good in 3 cases, fair in 5 cases and poor in 2 cases 12 weeks after operation, and the excellent and good rate was 86.5%. Conclusion T-shaped plate fixation is rel iable and effective in treatment of intra-articular fracture of distal radius because it has less coml ication of infection, loosening of internal fixation, reduction failure and tendon rupture.

    Release date:2016-09-01 09:08 Export PDF Favorites Scan
  • A PRELIMINARY REPORT OF OPEN REDUCTION AND NUMELOCK II POLYAXIAL SYSTEM FIXATION FOR TYPE C FRACTURE OF DISTAL RADIUS

    Objective To study the cl inical outcomes of Numelock II polyaxial system in treatment of type C fractures of the distal radius. Methods From March 2006 to June 2007, 12 cases of type C distal radial fractures (6 males and 6 females)were treated with open reduction and internal fixation. The mean age of the patients was 48.2 years (34-64 years).The locations were left wrist in 5 cases and right wrist in 7 cases, including 1 case of old fracture and 11 cases of fresh fractures. All fractures were closed. The mean course of disease was 9 days and 7 hours (4 hours to 60 days). According to AO/ASIF classification, there were 4 cases of C1 type, 5 cases of C2 type and 3 cases of C3 type. Preoperatively, the palmar tilt angle was —30° to 30° (— 5° on average), and the radial inclination angle was 5° to 13° (7.7° on average), and the radial shortening was 5 mm to 15 mm (9 mm on average). One case combined with dislocation of elbow joint and 2 cases combined with multi ple injuries. Results All incision healed by first intention. Postoperative follow-up ranged from 14 months to 29 months (15.6 months on average). The X-ray films showed that the union of fractures was achieved 6-8 weeks (6.6 weeks on average). No screws breakage occurred. The articular facets weresmooth in 11 of 12 patients. After operation, the palmar tilt angle was 0° to 15° (6.7° on average), and the radial inclination angle was 5° to 15° (10.2° on average), showing significant differences when compared with those before operation (P lt; 0.05). All the radial shortening was corrected. The ROM of the wrist was 55%-100% of the normal side. The grip strength was 55%-90% of the normal side. The results were excellent in 9 cases, good in 2 cases, and poor in 1 cases by X-ray film and wrist function assessment, the excellent and good rate was 91.7%. Conclusion Numelock II polyaxial system fixation is an ideal method to treat type C fractures of the distal radius. Numelock II polyaxial mechanism may provide the free adjustabil ity of screw trajectories and a higher degree of overall stabil ity compared to monoaxial locking plates.

    Release date:2016-09-01 09:06 Export PDF Favorites Scan
  • CLINICAL EFFECTS OF LOCKING PLATE SYSTEM IN TREATING DISTAL RADIAL FRACTURES

    Objective To determine the cl inical results of locking plate system in the treatment of distal radial fractures. Methods From May 2004 to November 2006, 75 patients were treated with 2.4 mm locking plate system. There were 41 males and 34 females, with a mean age of 51 years old (range, 13-82 years old). The locations were left side in 34 casesand right side in 41 cases. The cause of injury was a low energy fall in 49 cases, fall ing from height in 14 cases, traffic accident in 6 cases and sports injuries in 6 cases. All patients were diagnosed as having closed fracture. According to Müller-AO classification, there were 14 cases(18.7%) of type A, 5 cases(6.7%) of type B, and 56 cases(74.6%) of type C. The time from injury to operation was 5 hours to 27 days (mean 6 days). Results A total of 75 patients were followed up at 3 months, 71 patients at 6 months, 68 patients at 1 year and 51 patients at 2 years. Heal ing by first intention of incision was achieved in 73 cases, and infection occurred in 2 cases. Fracture reduction failed at 1 month, 3 months and 6 months in 1 case, respectively; 1 case received plaster fixation and 2 cases received re-fixation and autograft of il ium; and fracture healed in 3 cases at last follow-up. Two patients complained of skin numbness at site of superficial branch of radial nerve after 1 day, 1 patient had wound pain after operation, and 1 patient had infection of tendon at 3 days and 5 days in 1 case respectively. At last follow-up, the ranges of motion of wrist joint were (80 ± 9)° for pronation, (86 ± 7)° for supination, (57 ± 10)° for dorsal flexion, (51 ± 13)° for palmar flexion, (18 ± 7)° for radial incl ination, and (28 ± 7)° for ulnar deviation. According to modified Green scoring, the results were excellent in 66 cases, good in 6 cases and poor in 3 cases. At last follow-up, according to Knirk criterion for osteoarthritis, there were 22 cases of grade I and 5 cases of grade II, and all were classified as type C. Conclusion Internal fixation of distal radial fractures with 2.4 mm locking plate system provided a stable fixation with good cl inical outcomes.

    Release date:2016-09-01 09:08 Export PDF Favorites Scan
4 pages Previous 1 2 3 4 Next

Format

Content