west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "椎间融合术" 62 results
  • RESEARCH PROGRESS OF SURGICAL SELECTION OF FUSION LEVELS FOR DEGENERATIVE SCOLIOSIS

    ObjectiveTo summarize the progress of the surgical selection of fusion levels for degenerative scoliosis. MethodsThe domestic and foreign related literature about degenerative scoliosis, including clinical features, classification, surgical treatment, and the fused segment, was summarized. ResultsDegenerative scoliosis is very complicated. Short segment fusion and long segment fusion are the main surgical types. The long segment fusion is better in terms of reconstructing the stability of spine; however, it has more related complications. The short segment fusion has been used widely in clinical, but it causes degenerative disease easily. W/AL value can be used to direct the selection of short or long segment fusion for degenerative scoliosis. ConclusionThe key to success surgery is choosing reasonable fused segment. Now there is no unified selection standard. With more knowledge about degenerative scoliosis, greater development can be expected in the future.

    Release date: Export PDF Favorites Scan
  • Comparison of effectiveness of cortical bone trajectory screw fixation and pedicle screw fixation in posterior lumbar interbody fusion

    Objective To compare the effectiveness of cortical bone trajectory screw (CBTS) and conventional pedicle screw for posterior lumbar interbody fusion (PLIF) in the treatment of single segment lumbar degenerative disease. Methods Between May 2013 and May 2016, a total of 97 patients with single segment lumbar degenerative disease were treated with PLIF. Fifty-one patients were fixed with CBTS in PLIF (trajectory screw group) and 46 with pedicle screw (pedicle screw group). There was no significant difference in age, gender, body mass index, preoperative diagnosis, lesion segment, and preoperative visual analogue scale (VAS) score, Oswestry dysfunction index (ODI) between 2 groups (P>0.05). The operation time, intraoperative blood loss, postoperative drainage, bed rest time, length of hospital stay, serum creatine kinase (CK) concentration, total amount of diclofenac sodium, perioperative complications, ODI, VAS score, and interbody fusion rate were recorded and compared between 2 groups. Results All patients were followed up 12 months. The patients in trajectory screw group had a significantly less operation time, intraoperative blood loss, postoperative drainage, and serum CK concentration when compared with the patients in pedicle screw group (P<0.05). Thirty-five patients (68.6%) in trajectory screw group and 46 patients (100%) in pedicle screw group were given diclofenac sodium within 48 hours after operation, showing significant difference between 2 groups (χ2=89.334, P=0.000). There was no significant difference in the incidence of perioperative complications between trajectory screw group and pedicle screw group (3.9% vs. 8.7%, P=0.418). There was no significant difference in the VAS score, ODI, and interbody fusion rate at 12 months after operation between 2 groups (P>0.05). Conclusion For the single segment degenerative lumbar disease, the use of CBTS or conventional pedicle screw for PLIF can obtain satisfactory clinical function and interbody fusion rate. But the former has the advantages of less blood loss, less intraoperative muscle damage, less perioperative pain, shorter length of hospital stay and bed rest time.

    Release date:2017-11-09 10:16 Export PDF Favorites Scan
  • Efficacy and safety of tranexamic acid sequential rivaroxaban on blood loss in elderly patients during lumbar interbody fusion

    ObjectiveTo investigate the effect and safety of tranexamic acid sequential rivaroxaban on perioperative blood loss and preventing thrombosis for elderly patients during lumbar interbody fusion (LIF) with a prospective randomized controlled study.MethodsBetween April and October 2019, the elderly patients with lumbar degenerative diseases requiring LIF were included in the study, among which were 80 patients met the selection criteria. According to the antifibrinolysis and anticoagulation protocols, they were randomly divided into a tranexamic acid sequential rivaroxaban group (trial group) and a simple rivaroxaban group (control group) on average. Finally, 69 patients (35 in the trial group and 34 in the control group) were included for comparison. There was no significant difference in general data (P>0.05) such as gender, age, body mass index, disease duration, diseased segment, type of disease, and preoperative hemoglobin between the two groups. The operation time, intraoperative blood loss, drainage within 3 days after operation, perioperative total blood loss, and proportion of blood transfusion patients were compared between the two groups, as well as postoperative venous thrombosis of lower extremities, pulmonary embolism, and bleeding-related complications.ResultsThe operations of the two groups completed successfully, and there was no significant difference in the operation time (P>0.05); the intraoperative blood loss, drainage within 3 days after operation, and perioperative total blood loss in the trial group were significantly lower than those in the control group (P<0.05). The proportion of blood transfusion patients in the trial group was 25.71% (9/35), which was significantly lower than that in the control group [52.94% (18/34)] (χ2=5.368, P=0.021). Postoperative incision bleeding occurred in 4 cases of the trial group and 3 cases of the control group, and there was no significant difference in bleeding-related complications between the two groups (P=1.000). There was 1 case of venous thrombosis of the lower extremities in each group after operation, and there was no significant difference in the incidence between the two groups (P=1.000). Besides, no pulmonary embolism occurred in the two groups.ConclusionPerioperative use of tranexamic acid sequential rivaroxaban in elderly LIF patients can effectively reduce the amount of blood loss and the proportion of blood transfusion patients without increasing the risk of postoperative thrombosis.

    Release date:2020-09-28 02:45 Export PDF Favorites Scan
  • Application of three-dimensional printed porous titanium alloy cage and poly-ether-ether-ketone cage in posterior lumbar interbody fusion

    Objective To compare the effectiveness between three-dimensional (3D) printed porous titanium alloy cage (3D Cage) and poly-ether-ether-ketone cage (PEEK Cage) in the posterior lumbar interbody fusion (PLIF). Methods A total of 66 patients who were scheduled to undergo PLIF between January 2018 and June 2019 were selected as the research subjects, and were divided into the trial group (implantation of 3D Cage, n=33) and the control group (implantation of PEEK Cage, n=33) according to the random number table method. Among them, 1 case in the trial group did not complete the follow-up exclusion study, and finally 32 cases in the trial group and 33 cases in the control group were included in the statistical analysis. There was no significant difference in gender, age, etiology, disease duration, surgical segment, and preoperative Japanese Orthopaedic Association (JOA) score between the two groups (P>0.05). The operation time, intraoperative blood loss, complications, JOA score, intervertebral height loss, and interbody fusion were recorded and compared between the two groups. Results The operations of two groups were completed successfully. There was 1 case of dural rupture complicated with cerebrospinal fluid leakage during operation in the trial group, and no complication occurred in the other patients of the two groups. All incisions healed by first intention. There was no significant difference in operation time and intraoperative blood loss between groups (P>0.05). All patients were followed up 12-24 months (mean, 16.7 months). The JOA scores at 1 year after operation in both groups significantly improved when compared with those before operation (P<0.05); there was no significant difference between groups (P>0.05) in the difference between pre- and post-operation and the improvement rate of JOA score at 1 year after operation. X-ray film reexamination showed that there was no screw loosening, screw rod fracture, Cage collapse, or immune rejection in the two groups during follow-up. At 3 months and 1 year after operation, the rate of intervertebral height loss was significantly lower in the trial group than in the control group (P<0.05). At 3 and 6 months after operation, the interbody fusion rating of trial group was significantly better in the trial group than in the control group (P<0.05); and at 1 year after operation, there was no significant difference between groups (P>0.05). ConclusionThere is no significant difference between 3D Cage and PEEK Cage in PLIF, in terms of operation time, intraoperative blood loss, complications, postoperative neurological recovery, and final intervertebral fusion. But the former can effectively reduce vertebral body subsidence and accelerate intervertebral fusion.

    Release date:2022-09-30 09:59 Export PDF Favorites Scan
  • CLINICAL OBSERVATION TO ADJACENT-SEGMENT DISEASE AFTER ANTERIOR CERVICAL DISCECTOMYAND FUSION

    To probe the etiopathogenisis of adjacent-segment disease by analyzing the imageology data and cl inical neurological function in patients with anterior cervical discectomy and fusion (ACDF) harvested by long-term follow-up. Methods A retrospective study was performed on 52 patients who had undergone ACDF with perfect documents from January 1990 to April 2003. Of the patients, 45 were males and 7 were females with a mean age of 48.5 years (range from 25 to 72 years). There was the fusion of 10 one-levels, 38 two-levels and 4 three-levels. The cervical anterior-posterior and lateral X-ray, CT and MRI examination were performed before the operation. Cl inical neurological function was recorded by the Nurick score, and this score at 6 weeks after the operation was compared with the later follow-up. In the radiological examination, the motion of adjacent vertebrae and osteophyte formation were reviewed on X-ray and CT, and were converted to the semi-quantitative degeneration score according to the Goffin method. The correlation between Nurick score or degeneration score and the age at operation or fusion levels was compared by Spearman correlation coefficients. The cervical canal sizes of adjacent level and remote level on MRI were reviewed and compared with each other by t test. Results The follow-up period was 3 to 10 years, 6.9 years on average. There was difference in the Nurick score between the 6th week after operation (1.07 ± 0.84) and the later follow up (1.92 ± 1.28) by rank test (P lt; 0.05). There was no correlation between the Nurick score change and the age at operation (r = 0.21, P gt; 0.05) or fused levels(r = 0.30, P gt; 0.05) by Spearman correlation coefficients. There was obvious difference in degeneration score between the 6th week after operation (0.73 ± 0.67) and the later follow up (1.58 ± 1.06), (P lt; 0.01). There was no correlation between the degeneration score change and the age at operation (r = 0.35, P gt; 0.05) or fusion levels (r = 0.38, P gt; 0.05) by Spearman correlation coefficients. The cervical canal size reductions were (1.7 ± 1.1) mm at superioradjacent level, (1.2 ± 0.6) mm at inferior adjacent level and (0.30 ± 0.68) mm at remote level. There was obvious difference between superior or inferior and remote level by t test (P lt; 0.01). The adjacent level developed prominent degeneration together with nerve function change after the fusion operation and displayed correlation between degeneration and nerve function change(r = 0.41, P lt; 0.05). Conclusion The adjacent-segment disease after interbody fusion is produced by multiple factors. The natural progression in adjacent disc, biomechanical natural change resulting from interbody fusion, destruction to l igament structure in front of cervical vertebrae by operation, and bone graft model are important factors not to be ignored.

    Release date:2016-09-01 09:12 Export PDF Favorites Scan
  • CT value of vertebral body predicting Cage subsidence after stand-alone oblique lumbar interbody fusion

    ObjectiveTo investigate the correlation between CT value and Cage subsidence in patients with lumbar degenerative disease treated with stand-alone oblique lumbar interbody fusion (OLIF). MethodsThe clinical data of 35 patients with lumbar degenerative diseases treated with stand-alone OLIF between February 2016 and October 2018 were retrospectively analyzed. There were 15 males and 20 females; the age ranged from 29 to 81 years, with an average of 58.4 years. There were 39 operative segments, including 32 cases of single-segment, 2 cases of double-segment, and 1 case of three-segment. Preoperative lumbar CT was used to measure the CT values of the axial position of L1 vertebral body, the axial and sagittal positions of L1-4 vertebral body, surgical segment, and the axial position of upper and lower vertebral bodies as the bone mineral density index, and the lowest T value was recorded by dual-energy X-ray absorptiometry. The visual analogue scale (VAS) and Oswestry disability index (ODI) scores were recorded before operation and at last follow-up. At last follow-up, the lumbar interbody fusion was evaluated by X-ray films of the lumbar spine and dynamic position; the lumbar lateral X-ray film was used to measure the subsidence of the Cage, and the patients were divided into subsidence group and nonsubsidence group. The univariate analysis on age, gender, body mass index, lowest T value, CT value of vertebral body, disease type, and surgical segment was performed to initially screen the influencing factors of Cage subsidence; further the logistic regression for multi-factor analysis was used to screen fusion independent risk factors for Cage subsidence. The receiver operating characteristic (ROC) curve and area under curve (AUC) were used to analyze the CT value and the lowest T value to predict the Cage subsidence. Spearman correlation analysis was used to determine the correlation between Cage subsidence and clinical results. Results All the 35 patients were followed up 27-58 months, with an average of 38.7 months. At last follow-up, the VAS and ODI scores were significantly decreased when compared with preoperative scores (t=32.850, P=0.000; t=31.731, P=0.000). No recurrent lower extremity radiculopathy occurred and no patient required revision surgery. Twenty-seven cases (77.1%) had no Cage subsidence (nonsubsidence group); 8 cases (22.9%) had at least radiographic evidence of Cage subsidence, the average distance of Cage subsidence was 2.2 mm (range, 1.1-4.2 mm) (subsidence group). At last follow-up, there was 1 case of fusion failure both in the subsidence group and the nonsubsidence group, there was no significant difference in the interbody fusion rate (96.3% vs. 87.5%) between two groups (P=0.410). Univariate analysis showed that the CT value of vertebral body (L1 axial position, L1-4 axial and sagittal positions, surgical segment, and upper and lower vertebral bodies axial positions) and the lowest T value were the influencing factors of Cage subsidence (P<0.05). According to ROC curve analysis, compared with AUC of the lowest T value [0.738, 95%CI (0.540, 0.936)], the AUC of the L1-4 axis CT value was 0.850 [95%CI (0.715, 0.984)], which could more effectively predict Cage subsidence. Multivariate analysis showed that the CT value of L1-4 axis was an independent risk factor for Cage subsidence (P<0.05). Conclusion The CT value measurement of the vertebral body based on lumbar spine CT before stand-alone OLIF can predict the Cage subsidence. Patients with low CT values of the lumbar spine have a higher risk of Cage subsidence. However, the Cage subsidence do not lead to adverse clinical results.

    Release date:2021-12-07 02:45 Export PDF Favorites Scan
  • Comparative study of microendoscope-assisted and conventional minimally invasive transforaminal lumbar interbody fusion for degenerative lumbar diseases

    Objective To analyze the medium and long-term effectiveness of microendoscope-assisted minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) for lumbar degenerative diseases in comparison with conventional tubular retractor-assisted MIS-TLIF. Methods Between November 2008 and March 2013, 53 patients with single segment lumbar degenerative diseases were enrolled. According to the different working channel performed, 28 patients were treated by microendoscope-assisted MIS-TLIF (observation group), while the remaining cases received conventional tubular retractor-assisted MIS-TLIF via Wiltse approach (control group). Preoperative baseline data, including age, gender, body mass index, disease etiology, operated level, the ration for requiring bilateral canal decompression, and preoperative visual analogue scale (VAS) socre of low back pain and leg pain, Japanese Orthopedic Association (JOA) score, Oswestry disability index (ODI) score, showed no significant difference between the two groups (P>0.05). The operation time, intraoperative blood loss, intraoperative fluoroscopy time, postoperative analgesic drug dose, postoperation in-bed time, and perioperative complication incidence were recorded respectively and compared between the two groups. Radiographic evaluation of interbody fusion was performed based on Bridwell grading system at 2 years after operation. VAS scores of low back pain and leg pain, JOA score, and ODI score were assessed before operation, at 2 years after operation, and at last follow-up respectively. Surgical outcome satisfaction was assessed by modified MacNab criteria at last follow-up. Results When compared with those in control group, both intraoperative blood loss and postoperative analgesic drug dose were significantly decreased in observation group (P<0.05); similarly, the operation time and intraoperative fluoroscopy time were also significantly increased in observation group (P<0.05). There was no significant difference of postoperative in-bed time between the two groups (t=–0.812, P=0.420). Both groups were followed up 6-10.3 years, with an average of 7.9 years. Regarding perioperative complication, its incidence was 14.3% and 20.0% in observation group and control group, respectively, showing no significant difference between both groups (χ2=0.306, P=0.580). Specifically, there were intraspinal hematoma formation in 1 case, incision infection in 1 case, urinary infection in 1 case, transient delirium in 1 case in observation group. By contrast, there were dural tear and cerebrospinal fluid leakage in 1 case, urinary infection in 1 case, pneumonia in 1 case, transient delirium in 2 cases in control group. Bridwell criterion was used to judge the intervertebral fusion at 2 years after operation, the fusion rates of observation group and control group were 92.9% and 92.0%, respectively, showing no significant difference (χ2=0.162, P=0.687). At both 2-year postoperatively and last follow-up, the VAS scores of low back pain and leg pain, JOA score, and ODI score were significantly improved when compared with those before operation (P<0.01), whereas no significant difference between the two groups at either time point was found (P>0.05). At last follow-up, the results of patients’ satisfaction with surgery evaluated by modified MacNab criteria, and the excellent and good rates of the observation group and the control group were 96.4% and 92.0%, respectively, showing no significant difference (χ2=0.485, P=0.486). Conclusion The medium and long-term effectiveness of microendoscope-assisted MIS-TLIF are similar to those of conventional tubular retractor-assisted MIS-TLIF for lumbar degenerative diseases. The former operation has the additional advantages in terms of more clear surgical site visually, less intraoperative blood loss, and reduced postoperative analgesic dose, all of which seem more feasible to clinical teaching.

    Release date:2019-06-20 03:12 Export PDF Favorites Scan
  • BIOMECHANICAL STUDY ON KIDNEY-SHAPED NANO-HYDROXYAPATITE/POLYAMIDE 66 CAGE

    ObjectiveTo compare the biomechanical differences between the kidney-shaped nano-hydroxyapatite/polyamide 66 (n-HA/PA66) Cage and the bullet-shaped n-HA/PA66 Cage. MethodsL2-L5 spinal specimens were selected from 10 adult male pigs. L2, L3 and L4, L5 served as a motor unit respectively, 20 motor units altogether. They were divided into 4 groups (n=5):no treatment was given as control group (group A); nucleus pulposus resection was performed (group B); bullet-shaped Cage (group C), and kidney-shaped Cage (group D) were used in transforaminal lumbar interbody fusion (TLIF) through left intervertebral foramen and supplemented by posterior pedicle screw fixation. The intervertebral height (IH) and the position of Cages were observed on the X-ray films. The range of motion (ROM) was measured. ResultsThere was no significant difference in the preoperative IH among 4 groups (F=0.166, P=0.917). No significant change was found in IH between at pre- and post-operation in group B (P>0.05); it increased after operation in groups C and D, but difference was not statistically significant (P>0.05). There was no significant difference in the postoperative IH among groups B, C, and D (P>0.05). The distance from Cage to the left margin was (3.06±0.51) mm in group C (close to the left) and (5.68±0.69) mm in group D (close to the middle), showing significant difference (t=6.787, P=0.000). The ROM in all directions were significantly lower in groups C and D than in groups A and B (P<0.05), and in group A than in group B (P<0.05). The right bending and compression ROM of group C were significantly higher than those of group D (P<0.05), but no statistically significant difference was found in the other direction ROM (P>0.05). ConclusionThe bullet-shaped and kidney-shaped Cages have similar results in restoring IH and maintaining the stability of the spine assisted by internal fixation. Kidney-shaped Cage is more stable than bullet-shaped Cage in the axial compression and the bending load opposite implant, it can be placed in the middle and back of the vertebral body more ideally.

    Release date: Export PDF Favorites Scan
  • Comparative study on effectiveness of percutaneous endoscopic and Wiltse-approach transforaminal lumbar interbody fusion in the treatment of lumbar spondylolisthesis

    Objective To compare the effectiveness of percutaneous endoscopic transforaminal lumbar interbody fusion (PE-TLIF) and Wiltse-approach TLIF (W-TLIF) in the treatment of lumbar spondylolisthesis. MethodsThe clinical data of 47 patients with lumbar spondylolisthesis who met the selection criteria between July 2018 and June 2019 were retrospectively analyzed, in which 21 patients were treated with PE-TLIF (PE-TLIF group) and 26 patients were treated with W-TLIF (W-TLIF group). There was no significant difference between the two groups in age, gender, disease duration, level of spondylolisthesis vertebrae, spondylolisthesis degree, spondylolisthesis type, and preoperative visual analogue scale (VAS) score of low back pain and leg pain, lumbar Japanese Orthopaedic Association (JOA) score, and the disc height (DH), segmental lordosis (SL), and Taillard index (TI) of the operated vertebrae (P>0.05). The operation time, intraoperative blood loss, postoperative drainage, postoperative bedridden time, and complications were compared between the two groups. The VAS score and JOA score were used to evaluate the improvement of pain and function. At last follow-up, DH, SL, and TI of operated vertebrae were measured by X-ray films, and lumbar CT was performed to evaluate the interbody fusion. Results Compared with W-TLIF group, the operation time in PE-TLIF group was significantly longer, but the intraoperative blood loss and postoperative drainage were significantly less, and the postoperative bedridden time was significantly shorter (P<0.05). There were 2 cases of transient lower limb radiating pain in PE-TLIF group and 1 case of superficial incision infection in W-TLIF group. There was no significant difference in the incidence of complications (9.5% vs. 3.8%) between the two groups (χ2=0.037, P=0.848). The patients in both groups were followed up 12-24 months, with an average of 17.3 months in PE-TLIF group and 17.7 months in W-TLIF group. The VAS scores of low back pain and leg pain, and the JOA scores of the two groups significantly improved at each time point after operation when compared with those before operation (P<0.05). Compared with W-TLIF group, the VAS scores of low back pain in PE-TLIF group significantly lower at 3 days and 3 months after operation (P<0.05), and the JOA score of PE-TLIF group was significantly higher at 3 months after operation (P<0.05), and there was no significant difference in each score at any other time point between the two groups (P>0.05). At last follow-up, the DH, SL, and TI of operated vertebrae of the two groups significantly improved when compared with those before operation (P<0.05), and there was no significant difference in the differences of each parameter between the two groups (P>0.05). According to Suk’s standard, the fusion rates of PE-TLIF group and W-TLIF group were 90.5% (19/21) and 92.3% (24/26), respectively, with no significant difference (χ2=0.000, P=1.000). At last follow-up, there was no case of Cage sunk into the adjacent vertebral body, or dislodgement of Cage anteriorly or posteriorly in both groups. Conclusion PE-TLIF and W-TLIF are both effective in the treatment of grade Ⅰ and Ⅱ lumbar spondylolisthesis. Although the operation time is prolonged, PE-TLIF has less intraoperative blood loss and postoperative drainage, shorter postoperative bedridden time, and can get more obvious short-term improvement of low back pain and function.

    Release date:2022-01-27 11:02 Export PDF Favorites Scan
  • Comparison of accuracy between robot-assisted and fluoroscopy-guided percutaneous pedicle screw placement for treatment of lumbar spondylolisthesis

    Objective To explore the clinical application value of the spinal robot-assisted surgical system in mild to moderate lumbar spondylolisthesis and evaluate the accuracy of its implantation. Methods The clinical data of 56 patients with Meyerding grade Ⅰ or Ⅱ lumbar spondylolisthesis who underwent minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) between January 2017 and December 2017 were retrospectively analysed. Among them, 28 cases were preoperatively planned with robotic arm and percutaneous pedicle screw placement according to preoperative planning (group A); the other 28 cases underwent fluoroscopy-guided percutaneous pedicle screw placement (group B). There was no significant difference in gender, age, body mass index, slippage type, Meyerding grade, and surgical segmental distribution between the two groups (P>0.05). The screw insertion angle was measured by CT, the accuracy of screw implantation was evaluated by Neo’s criteria, and the invasion of superior articular process was evaluated by Babu’s method. Results One hundred and twelve screws were implanted in the two groups respectively, 5 screws (4.5%) in group A and 26 screws (23.2%) in group B penetrated the lateral wall of pedicle, and the difference was significant (χ2=9.157, P=0.002); the accuracy of nail implantation was assessed according to Neo’s criteria, the results were 107 screws of degree 0, 3 of degree 1, 2 of degree 2 in group A, and 86 screws of degree 0, 16 of degree 1, 6 of degree 2, 4 of degree 3 in group B, showing significant difference between the two groups (Z=4.915, P=0.031). In group B, 20 (17.9%) screws penetrated the superior articular process, while in group A, 80 screws were removed from the decompression side, and only 3 (3.8%) screws penetrated the superior articular process. According to Babu’s method, the degree of screw penetration into the facet joint was assessed. The results were 77 screws of grade 0, 2 of grade 1, 1 of grade 2 in group A, and 92 screws of grade 0, 13 of grade 1, 4 of grade 2, 3 of grade 3 in group B, showing significant difference between the two groups (Z=7.814, P=0.029). The screw insertion angles of groups A and B were (23.5±6.6)° and (18.1±7.5)° respectively, showing significant difference (t=3.100, P=0.003). Conclusion Compared to fluoroscopy-guided percutaneous pedicle screw placement, robot-assisted percutaneous pedicle screw placement has the advantages such as greater accuracy, lower incidence of screw penetration of the pedicle wall and invasion of the facet joints, and has a better screw insertion angle. Combined with MIS-TLIF, robot-assisted percutaneous pedicle screw placement is an effective minimally invasive treatment for lumbar spondylolisthesis.

    Release date:2018-10-31 09:22 Export PDF Favorites Scan
7 pages Previous 1 2 3 ... 7 Next

Format

Content