west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "生物瓣膜" 14 results
  • 牛心包生物瓣膜的临床应用

    目的 报告牛心包生物瓣膜置换治疗瓣膜疾病的临床经验和手术效果。 方法 自2003年1月至2005年12月,52例患者接受心瓣膜置换术,其中心功能分级(NYHA)Ⅱ级11例,Ⅲ级34例,Ⅳ级7例,36例患者合并心房颤动;行二尖瓣置换术25例,三尖瓣置换术6例,主动脉瓣置换术13例,肺动脉瓣置换术1例,主动脉瓣加二尖瓣置换术6例,二尖瓣加三尖瓣置换术1例;术后通过电话随访患者恢复情况。 结果 住院期间死亡1例,手术死亡率为1.9%(1/52);术后并发呼吸道感染2例,51例患者均顺利康复出院;术后住院时间10.8±3.3d(6~22d)。术后随访37例,随访时间15d~24个月,随访率72.5%(37/51),心功能均恢复到Ⅰ~Ⅱ级,无1例患者出现出血和栓塞,无再次瓣膜手术。 结论 生物瓣膜具有较高的手术安全性,患者的心功能恢复较好,术后出血、栓塞、瓣膜毁损和感染性心内膜炎、再次瓣膜手术的发生率可能较低,具有较好的疗效,患者的生活质量较高。

    Release date:2016-08-30 06:15 Export PDF Favorites Scan
  • Tricuspid Valve Replacement: Medium-and Long-term Results in 67 Cases

    Objective To analyze the medium-and long-term r esults of tricuspid valve replacement(TVR), to summarize the experience in opera tive therapy for tricuspid valve disease. Methods From January 1998 to May 2006, sixty seven patients had undergone TVR. The etiology was rheumatic disease in 25 cases, congenital disease in 37 cases, degenerative disease in 1 case, infective endocarditis in 3 cases, a nd cardiac tumor in 1 case. All operations were performed under general anesthes i a and by cardiopulmonary bypass. Bioprostheses was replaced in 28 patients, whil e mechanical valve was replaced in 39 patients. Associated procedure included mi tral valve replacement in 13 cases, mitral valve replacement and aortic valve replac ement in 12 cases, repair of ventricular septal defect in 1 case, repair of atri al septal defect in 1 case, and radioablation of atrial fibrillation in 3 case s. Results The operative mortality was 11.94% (8/67),among these patients , 6 cases died of serious heart failure,1 case died of ventricular fibrillation, 1 case died of multi organ failure. During follow-up, 1 patient died of biopro thesis dysfunction 1 year after the operation, 1 patient died of cerebral emboli s m 6 years after the operation. Through statistical analysis, it showed that the mortality of TVR in rheumatic tricuspid valve disease was higher than that in co ngenital tricuspid valve disease [5.56%(2/36)vs. 24.00% (6/25); χ2=4.425 , P=0.036]; the mortality in second time operation was higher than that in first time operation [30.00%(3/10)vs. 8.77% (5/57);χ2=3.646,P=0.033 ]; while there was no significant difference in immediate and long-term result s with different choice of bioprosthetic or mechanical valve in TVR (χ2=0.002 , P=0.961). Conclusion Operative an d follow-up mortality is high in the TVR, valve replac ement is the last selection for the treatment of serious tricuspid disease, appr opriate operative technique and perioperative therapy is the key for success o f the operation.

    Release date:2016-08-30 06:09 Export PDF Favorites Scan
  • Rational Choice of Mechanical and Bioprosthesis Valve

    Heart valve replacement is the major surgical treatment of severe valvular diseases. Due to the durability and reoperation-free, mechanical valves are widely used. Bioprosthesis valves became popular recently because of long service life and no demand for lifelong anticoagulation. However, how to choose the appropriate prosthetic heart valves, especially the application of bioprosthesis valves for patients at 55 to 65 years is still a major problem. This review focuses on more effective and scientific basis for rational choice of mechanical and bioprosthesis valve.

    Release date: Export PDF Favorites Scan
  • Clinical research status and progress of redo-transcatheter aortic valve replacement for structural biovalvular degeneration

    Biological valves can lead to structural valve degeneration (SVD) over time and due to various factors, reducing their durability. SVD patients need to undergo valve replacement surgery again, while traditional open chest surgery can cause significant trauma and patients often give up treatment due to intolerance. Research has shown that as an alternative treatment option for reoperation of thoracic valve replacement surgery, redo-transcatheter aortic valve replacement for SVD is safe and effective, but still faces many challenges, including prosthesis-patient mismatch, high cross valve pressure difference, and coronary obstruction. This article aims to review the strategies, clinical research status and progress of redo-transcatheter aortic valve replacement in SVD patients.

    Release date:2024-02-29 12:02 Export PDF Favorites Scan
  • 206例心脏生物瓣膜临床应用分析

    目的总结分析异种生物瓣膜置换术的临床应用结果,评价生物瓣膜在心脏外科中的应用效果和趋势。方法回顾性分析 2004年 7月至 2008年 7月在中国医科大学附属第一医院接受异种生物瓣膜置换术患者 206例的临床资料,男 157例,女 49例;年龄 44~ 79(64.7±13.2)岁。置换生物瓣膜 227枚,联合置换机械瓣膜 11枚;同期行冠状动脉旁路移植术( CABG)51例,房 /室间隔缺损修补术 7例。结果术后早期( 30 d内)死亡 7例。院外随访 6个月~ 5年,平均随访 23个月,随访 134例,随访率 67.3% ( 134/199)。随访患者心功能均得到不同程度的改善,未发现瓣周漏、感染性心内膜炎、血栓和出血等并发症。彩色多普勒超声心动图提示生物瓣膜功能良好,无明显衰败迹象。结论异种生物瓣膜置换疗效确切,并发症少,近期效果较好。

    Release date:2016-08-30 05:50 Export PDF Favorites Scan
  • Short-term results of valve-in-valve transcatheter aortic valve implantation in patients with degenerated bioprosthesis

    Objective To summarize the short-term results of valve-in-valve transcatheter aortic valve implantation (ViV-TAVI) in the treatment of bioprosthetic valve failure after aortic valve replacement. Methods We reviewed the clinical data of patients who underwent ViV-TAVI from 2021 to 2022 in the First Affiliated Hospital of Zhengzhou University. The valve function was evaluated by echocardiography before operation, immediately after operation and 3 months after operation. The all-cause death and main complications during hospitalization were analyzed. Results A total of 13 patients were enrolled, including 8 males and 5 females with a mean age of (65.9±8.5) years, and the interval time between aortic valve replacement and ViV-TAVI was (8.5±3.4) years. The Society of Thoracic Surgeons mortality risk score was 10.3%±3.2%. None of the 13 patients had abnormal valve function after operation. The mean transvalvular pressure gradient of aortic valve was decreased (P<0.001), the peak flow velocity of aortic valve was decreased (P<0.001), and the left ventricular ejection fraction was not changed significantly (P=0.480). There were slight perivalvular leakage in 2 patients and slight valve regurgitation in 3 patients. Three months after operation, the mean transvalvular pressure difference and peak flow velocity of aortic valve in 12 patients were significantly decreased compared with those before operation (P≤0.001). Conclusion This study demonstrates that ViV-TAVI for the treatment of bioprosthetic valve failure after aortic valve replacement is associated with favorable clinical and functional cardiovascular benefits, the short-term results are satisfactory.

    Release date:2025-06-24 11:15 Export PDF Favorites Scan
  • Biological and Biomechanical Properties of Acellular Porcine Aortic Valve Stabilized by Dye Mediated Photo Oxidation

    Objective To investigate the biological and biomechanical characteristics of acellular porcine aortic valve with dye mediated photo oxidation so that a new and better bioprosthetic valve materials can be obtained. Methods Thirty porcine aortic valves were divided into three groups with random number table. Acellular valves (n=10) were stabilized by dye mediated photo oxidation in dye mediated photo oxidation group; acellular valves (n=10) were stabilized by glutaraldehyde in glutaraldehyde group; and acellular valves (n=10) were acellularized only in acellular valves group. Thickness, appearance, histology, water content, shrinkage temperature, breaking strength and soluble protein level of acellular porcine aortic in three groups were tested respectively. Results There were light blue, soft, flexible and unshrinking valves in dye mediated photo oxidation group. Compared to valves in glutaraldehyde group, valves in dye mediated photo oxidation group had lighter thickness(0.26±0.09mm vs. 0.38±0.08mm,Plt;0.05), more water content(86.30%±4.03% vs. 71.10%±3.23%,Plt;0.05), and lower shrinkage temperature (76.30±0.70℃ vs. 87.70±0.30℃,Plt;0.05); while these indexes had no statistically significant differences compared to those in acellular valves group. At the same time, compared to valves in acellular valves group, valves in dye mediated photo oxidation group had more breaking strength(17.33±2.65 mPa vs. 9.11±0.95 mPa,Plt;0.05) and lower soluble protein level(0.039%±0.013% vs. 0.107%±0.024%,Plt;0.05); while these indexes had no statistically significant differences compared to those in glutaraldehyde group. Conclusion Acellular porcine aortic valve stabilized by dye mediated photo oxidation has nice biological and biomechanical characteristics.

    Release date:2016-08-30 06:08 Export PDF Favorites Scan
  • Research status of commissural alignment between biological valve and autologous valve in transcatheter aortic valve replacement

    Commissural misalignment of biological valve and autologous valve during transcatheter aortic valve replacement may affect the filling of coronary artery, reduce the feasibility of redo-aortic valve intervention and damage the valve function, which will adversely affect long-term prognosis of patients. Some studies have obtained achievement by changing the axial direction of valve and using individualized computer simulation technology to improve the alignment technology. However, there are still many unknown problems about the impact of commissural misalignment on patients, and accurate commissural alignment techniques still need to be further explored. This article systematically expounds the possible impact of commissural misalignment between biological valve and autologous valve in transcatheter aortic valve replacement, possibly effective accurate commissural alignment techniques and related research progress.

    Release date:2022-05-24 03:47 Export PDF Favorites Scan
  • Influence of different kinds of valve types on clinical benefits of elderly patients with valvular heart disease

    ObjectiveTo investigate the influence of mechanical and biological valves on clinical benefits of elderly patients with valvular heart disease.MethodsWe retrospectively analyzed the clinical data of 280 elderly patients with valvular heart disease treated by valve replacement between 2008 and 2014 year. The patients were divided into two groups by tendency score matching including a group A with biological valves and a group B with mechanical valves. Finally, there were 96 patients in each group. There were 43 males and 53 females at age of 64.41±6.52 years in the group A, 44 males and 52 females at age of 64.07±6.20 years in the group B.ResultsThe bleeding rate of skin and mucosa of the group B was significantly higher than that of the group A (P<0.05). There was no statistical difference in mortality within 30 days after operation, all-cause mortality, re-hospitalization rate, re-valve replacement rate, combined atrial flutter/atrial fibrillation ratio, drug use, incidence of cerebral infarction, cerebral hemorrhage, new peripheral vascular embolism and visceral hemorrhage, heart function (NYHA) classification, the cumulative survival rate of all the patients during follow-up (P=0.63), or the cumulative survival rate of the patients with no thrombus/hemorrhage (P=0.75) between the two groups (P>0.05).ConclusionMechanical valve replacement and bioprosthetic valve replacement in the treatment of valvular heart disease in the elderly can achieve similar clinical benefits and both have clinical application value.

    Release date:2020-07-30 02:16 Export PDF Favorites Scan
  • Hemocompatibility of bioprosthetic heart valve materials respectively based on glutaraldehyde and non-glutaraldehyde treatment

    ObjectiveTo study the hemocompatibility of bioprosthetic heart valve materials respectively based on glutaraldehyde and non-glutaraldehyde treatment. MethodsFresh bovine pericardium was treated with glutaraldehyde or non-glutaraldehyde after adipose tissue was removed. To evaluate the hemocompatibility of the two bioprosthetic heart valve materials, hemolysis test, in vitro fibrinogen adsorption experiment, platelet adhesion experiment, thrombin-antithrombin complex (TAT) test, complement activation assay and ex vivo circulation experiment were performed. ResultsThe hemolysis test results demonstrated that both of the materials showed hemolytic rates lower than 5%. The results of TAT test and complement activation assay showed no statistical differences among the two materials and the blank control group. Compared to the bioprosthetic heart valve materials with glutaraldehyde-based treatment, the materials with non-glutaraldehyde-based treatment showed significantly decreased fibrinogen adsorption, platelet adhesion and thrombosis. ConclusionCompared to the bioprosthetic heart valve materials with glutaraldehyde-based treatment, the materials with non-glutaraldehyde-based treatment show better hemocompatibility.

    Release date:2023-08-31 05:57 Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content