Objective To investigate the characteristics of ultrasonogram of eyes with silicon oil tamponade. Methods Forty-seven patients (47 eyes) who had undergone the operation of silicon-oil removing were examined by A-(to determine the length of ocular axis) and B-scan before and after the operation respectively. The length of ocular axis and cubage of vitreous chamber were detected and the characteristics of the ultrasonograms were observed according to the default parameters of ultrasonograph. Results The results of A-scan showed that the preoperative axial length was 1.465 times of the postoperative one in the eyes without lens, and 1.284 times in eyes with lens; after modified the parameter according to the acoustic velocity, the preoperative axial length was (0.78±0.34) mm longer than the postoperative one in the eyes without lens, and (0.56±0.32) mm in eyes with lens. The results of A-scan showed that the cubage of vitreous chamber enlarged obviously in eyes with silicon oil tamponade, and the acoustic features included complete filling and partial filling according to the amount of silicon oil. Several arc echoes at the posterior segment of eye were detected in the silicon-oil-filling eyes with retinal detachment. Conclusion In the silicon-oil-filling eyes with lengthened ocular axis, the characteristics of B-scan images are affected by acoustic velocity through silicon oil, the amount of silicon oil capacity and the emulsification of silicon oil. (Chin J Ocul Fundus Dis,2004,20:349-351)
ObjectiveTo observe the demographic data, disease composition and convenience of remote consultation in ophthalmology. MethodsA retrospective study. From 2015 to 2021, the demographic data, changing trends, disease classification of teleconsultation patients, and hospitals participating in teleconsultation, and the waiting time of patients for teleconsultation was analyzed retrospectively; remote consultation physician level composition and other data was analyzed. ResultsDuring the 7-year period, 1 216 patients with remote consultation were obtained through the platform of the telemedicine center. Among them, there were 680 males and 536 females; the average age was 50.8 years. In 2016 and 2017, the number of patients participating in telemedicine consultations reached a peak of 260 and 221 cases, respectively. Among the ophthalmic diseases, there were 490 cases (40.30%, 490/1 216) of retinal and optic nerve-related diseases, 212 cases (17.43%, 212/1 216) of ocular trauma. 678 cases (56.27%, 678/1 205) of remote consultation waiting time were less than 24 hours, 991 cases (82.24%, 991/1 205) were less than 48 hours. Among the physicians who participated in the remote consultation, there were 733 chief physicians (60.3%, 733/1 216) and 466 deputy chief physicians (38.3%, 466/1 216). ConclusionsDuring the seven-year period from 2015 to 2021, there are relatively few patients with ophthalmology teleconsultation; retinal and optic nerve-related diseases accounted for a high proportion. Remote consultation has high convenience.
There has been ongoing progress in the new technique and equipment in vitreoretinal surgery in recent years, contributing to the improvement of treatment of various vitreoretinal diseases. The application of 3D heads-up display viewing system (3D viewing system) has been one of the most fascinating breakthroughs in vitreoretinal surgery. Unlike the traditional method in which the surgeons have to look through the microscope eyepieces, this system allows them to turn their heads up and operate with their eyes on a high-definition 3D monitor. It provides the surgeons with superior visualization and stereoscopic sensation. And increasing studies have revealed it to be as safe and effective as the traditional microscopic system. Furthermore, the surgeons can keep a heads-up position in a more comfortable posture and lesson the pressure on cervical spine. Meanwhile, 3D viewing system makes it easier for the teaching and learning process among surgeons and assistants. However, there are still potential disadvantages including the latency between surgeon maneuver and visualization on the display, learning curves and cost. We hope that the 3D viewing system will be widely used and become a useful new tool for various vitreoretinal diseases in the near future with rapid development in the technology and constant upgrade of the system.
With the perspective of evidence-based medicine, this review aims to investigate the effectiveness and safety of off-label drug use of bevacizumab for eye disease, and explore the barriers to further study. And then, suggestions for the supported evidence and clinical use of off-label drug use will be provided based on this case.
At present, artificial intelligence (AI) has been widely used in the diagnosis and treatment of various ophthalmological diseases, but there are still many problems. Due to the lack of standardized test sets, gold standards, and recognized evaluation systems for the accuracy of AI products, it is difficult to compare the results of multiple studies. When it comes to the field of image generation, we hardly have an efficient approach to evaluating research results. In clinical practice, ophthalmological AI research is often out of touch with actual clinical needs. The requirements for the quality and quantity of clinical data put more burden on AI research, limiting the transformation of AI studies. The prediction of systemic diseases based on fundus images is making progressive advancement. However, the lack of interpretability of the research lower the acceptance. Ophthalmology AI research also suffer from ethical controversy due to unconstructed regulations and regulatory mechanisms, concerns on patients’ privacy and data security, and the risk of aggravating the unfairness of medical resources.
ObjectiveTo analyze the consistency of diagnostic results using simple and comprehensive reading methods on stereoscopic color fundus photographs of diabetic retinopathy (DR) with diabetic macular edema (DME). Methods450 sets of 7-field stereoscopic color fundus photographs of DR DME were compared to standard fundus photographs of early treatment and DR study group. The pictures were read by two groups of reader with similar experience. Two strategies were used to make the judgments, including simple reading which based on the color fundus photographs only, and comprehensive reading which based on color fundus photographs, fundus fluorescein angiography (FFA) and optical coherence tomography (OCT). 15 parameters were scored, including micro-aneurysms (MA), intra-retinal hemorrhage (IRH), hard exudates (HE), cotton wood spot (CW), intra-retinal microvascular abnormalities (IRMA), neovascularization on optic disc (NVD), neovascularization elsewhere (NVE), optic fiber proliferation (FPD), fiber proliferation elsewhere (FPE), pre-retinal hemorrhage (PRH), vitreous hemorrhage (VH), retinal elevation (RE), retinal detachment of central macular (RDC), venous beading (VB), Venous leak (VL). The reliability was evaluated using weighted κ(κw) statistic values. According to Fleiss statistical theory, κw≥0.75, consistency is excellent; 0.60≤κw < 0.75, consistency is good; 0.40≤κw < 0.60, consistency is general; κw < 0.40, consistency is poor. ResultsThe κw values of these 15 parameters were 0.22-1.00, 0.28-1.00 for the simple reading and comprehensive reading respectively. For simple reading, the consistency was poor for 8 parameters (MA, NVD, NVE, FPE, PRH, IRMA, VB, VL), general for 3 parameters (CW, FPD, VH), good for 2 parameters (IRH, HE) and excellent for 2 parameters (RE, RDC). For comprehensive reading, the consistency was poor for 2 parameters (NVE, VB), general for 6 parameters (MA, IRH, CW, FPE, IRMA, VL), good for 2 parameters (NVD, HE), excellent for 5 parameters (FPE, PRH, VH, RE, RDC). ConclusionThe comprehensive reading has higher consistency to judge the abnormality parameters of the fundus photographs of DR with DME.