Objective To probe into the effectiveness of vertical compression of locking plate combined with hollow screws in the treatment of Sanders type Ⅱ and Ⅲ calcaneal fractures. MethodsThe clinical data of 128 patients with Sanders type Ⅱ and Ⅲ calcaneal fractures who were admitted between March 2019 and April 2022 and met the selection criteria were retrospectively analyzed. Among them, 65 patients were treated with locking plate combined with hollow screw vertical compression (study group), and 63 patients were treated with simple locking plate (control group). There was no significant difference in baseline data between the two groups (P>0.05), such as gender, age, fracture side and Sanders classification, cause of injury, time from injury to operation. The operation time, intraoperative blood loss, hospital stay, and fracture healing time were recorded and compared between the two groups. Before operation and at 12 months after operation, the American Orthopaedic Foot and Ankle Association (AOFAS) score (including total score, pain score, functional score, and alignment score) was used to evaluate the recovery of foot function, and imaging indicators such as calcaneal width, calcaneal height, calcaneal length, Böhler angle, and Gissane angle were measured on X-ray films. ResultsAll patients were followed up 12 months after operation. There was no significant difference in operation time, intraoperative blood loss, hospital stay, and fracture healing time between the two groups (P>0.05). Poor wound healing occurred in 1 case in the study group and 2 cases in the control group. At 12 months after operation, there was no significant difference between the two groups in the pre- and post-operative difference of calcaneal length, calcaneal height, Gissane angle, and Böhler angle (P>0.05). However, the pre- and post-operative difference in calcaneal width in the study group was significantly higher than that in the control group (P<0.05). The pre- and post-operative difference of AOFAS total score in the study group was significantly higher than that in the control group (P<0.05), and further analysis showed that the pre- and post-operative difference of pain and function scores in the study group were significantly higher than those in the control group (P<0.05), while there was no significant difference in the pre- and post-operative difference of force score between the two groups (P>0.05). ConclusionCompared with simple locking plate treatment, the treatment of Sanders type Ⅱ and Ⅲ calcaneal fractures with vertical compression of locking plate combined with hollow screws can more effectively improve the width of the subtalar calcaneal articular surface, avoid peroneal longus and brevis impingement, reduce pain, and increase the range of motion of the subtalar joint, and the effectiveness is better.
Objective To evaluate the clinical effect of cannulatedscrew on treatment of femoral neck fracture(FNF). Methods Forty-two FNFpatients were treated by using cannulated screw from January 2001 to December 2005.There were 22males and 20 females with an average age of 41 years (19-59 years). Fracture was caused by traffic accident in 21 cases, by falling from height in 14 cases and by bruise in 7 cases. All cases were fresh fracture. According to Garden criterion for typing, 15 cases were classified as type Ⅱ, 16 cases as type Ⅲ and 11 cases as type Ⅳ . It was 7 hours to 15 days from injury to operation. Results Thepatients were followed up for 1-6 years with an average of 2.5 years. The average fracture union time was 6.5 months. Three patients had ischemic necrosis of femoral head, andloosening and breakage of screw and rob was observed in 1 case. According to Brumback criterion for hip joint function, the result was excellent in 18 cases, good in 20 cases and bad in 4 cases, and the excellent and good rate was 90.4%. Conclusion Cannulated screw fixation is a good method to treat FNF in young adults. It can improve the rate of fracture union and reduce the rate of avascular necrosis of femoral head.
ObjectiveTo systematically review the efficacy of percutaneous cannulated screw (PCS) versus plate fixation (PF) in the treatment of ankle fractures. MethodsThe Cochrane Library (Issue 5, 2014), PubMed, EMbase, CBM, CNKI, VIP and WanFang Data were searched up to May 28th 2014, for studies concerning the efficacy of percutaneous cannulated screw versus plate fixation for ankle fractures. Two reviewers independently screened literature according to the inclusion and exclusion criteria, extracted data and assessed the methodological quality of included studies. Then, meta-analysis was performed by using RevMan 5.1 software. Result A total of 10 studies (3 RCTs and 7 CCTs) involving 627 patients were included. The results of meta-analysis showed that:compared with the PF group, the PCS group was superior in time of the operation (RCT:MD=-6.78, 95%CI -11.95 to -1.60, P=0.01; CCT:MD=-9.76, 95%CI -13.68 to -5.84, P<0.000 01), blood loss during the operation (RCT:MD=-36.14, 95%CI -40.02 to -32.17, P<0.000 01; CCT:MD=-34.80, 95%CI -37.78 to -31.81, P<0.000 01) and the time of the fracture healing (RCT:MD=-1.16, 95%CI -1.51 to -0.81, P<0.000 01; CCT:MD=-1.55, 95%CI -2.97 to -0.13, P=0.03); However, there were no statistical differences between the two groups in complication rate (CCT:OR=0.48, 95%CI 0.08 to 2.81, P=0.41), AOFAS score excellent rate (RCT:OR=2.11, 95%CI 0.81 to 5.49, P=0.12; CCT:OR=1.58, 95%CI 0.75 to 3.30, P=0.23), and postoperative malleolus pain rate (CCT:OR=0.68, 95%CI 0.00 to 148.82, P=0.89). ConclusionCurrent evidence shows that PCS is superior to PF in shorting time of the operation, reducing blood loss during the operation, and shorting time of the fracture healing. However, the complication rate, AOFAS score excellent rate, and postoperative malleolus pain rate are similar for each operation. Due to the quality limitation of the CCTs, the conclusion are needed to be verified by more high quality RCTs in future.
ObjectiveTo explore the effectiveness of hollow screw for the treatment of basilar part fracture of hamate hook.MethodsFive patients with basilar part fracture of hamate hook, aged 24-47 years (mean, 31 years) were treated with open reduction and hollow screw fixation between June 2015 and February 2019. There were 4 males and 1 female. The causes of injury were athletic injury in 3 cases, falling injury in 1 case, and crushing injury in 1 case. Among them, 1 case was combined with sensory disturbance of one and a half fingers on the ulnar side of the palm. The grip strength of the affected side was significantly decreased when compared with that of the healthy side in all patients. The intervals between injury and surgery were 3-8 days (mean, 4.2 days). Postoperative follow-up was conducted regularly to measure the grip strength of the affected and healthy fingers and the total motion of ring and little fingers of the affected side. Darrow criteria was used to evaluate the effectiveness.ResultsAll the incisions healed by primary intention. All the patients were followed up 6-32 months (mean, 16 months). X-ray films showed that the basilar part fracture of hamate hook reached bony union, and the healing time was 2.0-3.5 months (mean, 2.2 months). At last follow-up, the grip strength of the affected side was (35.80±3.76) kg, showing no significant difference when compared with healthy side [(36.00±4.94) kg] (t=0.094, P=0.930); and the total motion of ring and little fingers of the affected side was (529.0±8.9)°, which was significantly different from that before operation [(232.0±34.7)°] (t=18.108, P=0.000). In 1 patient with ulnar nerve injury, the two-point discrimination of the innervation area was 4 mm, and the pain sensation and temperature sensation returned to normal. Assessed by Darrow criteria, the results were excellent in 4 cases and good in 1 case.ConclusionFor the basilar part fracture of hamate hook, hollow screw fixation can obtain secure reduction and fixation and provide sustained compression and counter-rotation for the broken end of fracture, thus allowing early joint motion and promoting fracture healing and recovery of wrist function. It is a relatively good method for the treatment of basilar part fracture of hamate hook.
Objective To evaluate the clinical and radiographic outcomes of headless compression screws for Lisfranc joint injuries. Methods A retrospective analysis was made on clinical data of 34 patients (36 feet) with Lisfranc joint injuries who underwent open reduction and internal fixation with headless compression screws between January 2006 and January 2012. There were 22 males (24 feet) and 12 females (12 feet), aged 21-73 years (mean, 38.9 years). The causes of injury included traffic accident in 16 cases (17 feet), falling from height in 11 cases (12 feet), crushing in 5 cases (5 feet), and sports in 2 cases (2 feet). Of them, there were 19 cases (20 feet) of closed injury and 15 cases (16 feet) of open injury; there were 7 cases (8 feet) of pure dislocations of tarsometatarsal joints and ligamentous Lisfranc injuries (LD), 22 cases (23 feet) of Lisfranc joint fracture dislocations (LFD), 5 cases (5 feet) of combined Chopart-LFD (CLFD). According to Myerson classification, 5 cases (5 feet) were rated as type A, 7 cases (8 feet) as type B1, 14 cases (15 feet) as type B2, 5 cases (5 feet) as type C1, and 3 cases (3 feet) as type C2. Associated fractures included 12 cases (13 feet) of metatarsal shaft fracture, 4 cases (4 feet) of cuboid fracture, 4 cases (4 feet) of navicular bone fracture, 6 cases (7 feet) of coneiform bone fracture/dislocation, 8 cases (10 feet) of ipsilateral lower limb multiple fracture, and 4 cases (4 feet) of contralateral lower limb multiple fracture. The clinical outcomes were evaluated according to American Orthopaedic Foot and Ankle Society (AOFAS) score and visual analogue scale (VAS) score. Postoperative X-ray films were taken to assess the reduction, internal fixation, and the foot arch height. Results All patients were followed up 1 year to 5 years and 2 months (mean, 3.5 years). X-ray films showed anatomical reduction in 31 cases (33 feet, 91.7%). At last follow-up, AOFAS score and VAS score averaged 80.6 (range, 60-100) and 2.3 (range, 0-6), respectively; the AOFAS score was significantly higher in patients having anatomical reduction than the patients having no anatomical reduction, in patients with LD and LFD than in patients with CLFD, and in patients without cuneiform bone fracture/dislocation than in patients with cuneiform bone fracture/dislocation (P lt; 0.05). There was no significant difference in the talus-first metatarsal angle, the distance between the lateral edge of the base of the first metatarsal bone and the medial edge of the base of the second metatarsal bone, and the arch height between the injured foot and normal foot (P gt; 0.05). Reduction loss was observed in 1 case (1 foot) because of early weight bearing; post-traumatic arthritis developed in 9 patients (10 feet). The incidence of post-traumatic osteoarthritis was higher in the patients with non-anatomic reduction, coneiform bone fracture/dislocation, comminuted intra-articular fractures of Lisfranc joints, the injury types (P lt; 0.05). Conclusion Headless compression screws for fixation of Lisfranc joint injuries can provide satisfactory short- and mid-term clinical and radiographic outcomes. During surgery, the precise anatomic reduction and stable fixation should be paid attention to, especially in patients with CLFD, coneiform bone fracture/dislocation, and comminuted intra-articular fractures of Lisfranc joints so as to control the incidence of the post-traumatic osteoarthritis.
ObjectiveTo investigate and analyze the effectiveness of internal fixation with the two different cannulated screw implanting methods of rhomboid and inverted triangle in the treatment of femoral neck fracture in young adults.MethodsThe clinical data of 38 young adults with femoral neck fracture who met the selection criteria between January 2018 and August 2019 were retrospectively analyzed. According to the different methods of cannulated screw implanting, the patients were divided into two groups, 19 cases in each group. The trial group was treated with closed reduction and cannulated screw rhombic distribution internal fixation, while the control group was treated with closed reduction and cannulated screw inverted triangular distribution internal fixation. There was no significant differences in patients’ gender, age, cause of injury, Garden classification of fracture, and time from injury to operation between the two groups (P>0.05). The fracture healing time, the incidence of nonunion, femoral neck shortening, and femoral head necrosis were recorded and compared between the two groups; the effectiveness was evaluated by Harris score and visual analogue scale (VAS) score at last follow-up.ResultsThe incisions of the two groups healed by first intention. All patients were followed up 12-24 months with an average of 15.5 months. There were 1 case of fracture nonunion and 2 cases of shortening of femoral neck in the trial group; while there were 2 cases of fracture nonunion, 1 case of necrosis of femoral head, and 6 cases of femoral neck shortening in the control group; the difference in the incidence of complications (15.8% vs. 47.4%) between the two groups was significant (χ2=4.385, P=0.036). The remaining 18 cases in the trial group and 17 cases in the control group all achieved osteonal union, and the healing time was (14.8±1.6) weeks and (15.9±1.3) weeks, respectively, showing no significant difference between the two groups (t=1.265, P=0.214). At last follow-up, Harris score and VAS score of the trial group were 88.9±4.3 and 1.1±0.7, respectively, while those of the control group were 86.9±5.9 and 1.3±0.9, respectively, showing no significant difference (t=0.603, P=0.550; t=1.152, P=0.257). Hip function was evaluated in accordance with Harris score, the results were excellent in 12 cases, good in 6 cases, and fair in 1 case in the trial group, the excellent and good rate was 94.74%; the results were excellent in 10 cases, good in 7 cases, and fair in 2 cases in the control group, the excellent and good rate was 89.47%; there was no significant difference in the excellent and good rate between the two groups (χ2=0.368, P=0.544).ConclusionThe short-term effectiveness of the two kinds of cannulated screw implanting methods is clear, rhomboid fixation of 4 screws has strong stability with stress distribution, which can effectively reduce the incidence of femoral neck shortening, fracture nonunion, femoral head necrosis, and other complications.
【Abstract】 Objective To evaluate the effectiveness of percutaneous fixation of pelvic fracture by Acutrak full thread headless hollow compression screw. Methods Between March 2008 and April 2010, 31 patients with pelvic fracture underwent percutaneous fixation surgery with Acutrak full thread headless hollow compression screw (surgical group). The effectivenss was compared with those of 14 patients with pelvic fracture treated conservatively (control group). There was no significant difference in age and sex between 2 groups (P gt; 0.05). The injury was more severe in surgical group than in control group. The standard of short-term recovery was active turning over and walking for 5 steps with walking aids. The standard of long-term recovery was pain, gait, fracture healing, and function recovery. Results In surgical group, the other patients reached the standard of short-term recovery at 1-4 days after injury except 1 patient who had sacral plexus injury; in control group, the patients could turn over at 9-13 days (Tile type A2) and 17-25 days (Tile type B2) respectively, and could walk at 17-21 days (Tile type A2) and at 45-57 days (Tile type B2) respectively. The patients of 2 groups were followed up 6-19 months. The time of fracture healing was 2-6 months. The long-term results were excellent in 29 cases and good in 2 cases in surgical group, and were excellent in 8 cases and good in 6 cases in control group, showing significant difference between 2 groups (χ2=6.636, P=0.017).Conclusion Percutaneous internal fixation combined with Acutrak full thread headless hollow compression screw can provide more effective treatment. It can alleviate patients, pain quickly, improve life quality, and has better long-term effectiveness.
ObjectiveTo summarize the progress in treatment of pubic symphysis diastasis. MethodsRelated literature concerning treatment of pubic symphysis diastasis was extensively reviewed and comprehensively analyzed in terms of anatomy, biomechanics, and treatment. ResultsThere are many fixation methods for treatment of pubic symphysis diastasis, which aims at restoring the stability of the anterior pelvic ring. External fixator is often used as a temporary fixation; tension band wire has been abandoned due to its poor biomechanical stability; screw loosening and plate breakage often appears when a single reconstruction plate is used; box plate significantly increases the biomechanical stability of anterior pelvic ring but it leads to a considerable surgical trauma; locking plate has been used for pubic symphysis diastasis recently, especially for osteoporotic fractures; percutaneous cannulated screw has the advantages of less trauma, less bleeding, and good stability, so it is good choice for treatment of pubic symphysis diastasis. ConclusionThere is no uniform standards about the treatment of pubic symphysis diastasis, but the minimally invasive treatment is an undeniable trend. Percutaneous cannulated screw has achieved satisfactory effectiveness, however, its biomechanical stability and anatomic channels need to be further studied.
ObjectiveTo investigate the effectiveness of minimally invasive plate and medial supporting cannulated screw fixation via tarsal sinus approach in treatment of Sanders type Ⅱ and Ⅲ calcaneal fractures. Methods A clinical data of 46 patients with Sanders type Ⅱand Ⅲ calcaneal fractures met the selective criteria between March 2016 and March 2021 was retrospectively analyzed. The factures were fixed with minimally invasive plate and medial supporting cannulated screws via tarsal sinus approach in 20 cases (group A) and with minimally invasive plate in 26 cases (group B). There was no significant difference between groups in term of the gender, age, injury causes, fracture type and side, the time from injury to operation, and preoperative calcaneal length and width, Böhler angle, Gissane angle, and visual analogue scale (VAS) score (P>0.05). The operation time, intraoperative blood loss, hospital stay, and the interval between operation and full weight-bearing were recorded. The pain improvement of patients was evaluated by VAS scores before operation and at 48 hours after operation. The ankle joint function was evaluated by American Orthopaedic Foot and Ankle Society (AOFAS) score at 3 and 12 months after operation. Besides, the calcaneal length and width, Böhler angle, and Gissane angle were measured by X-ray films before and after operation. Furthermore, the difference (loss value) between 3, 12 months and 1 day after operation was calculated. Moreover, the fracture healing and healing time was observed. ResultsAll operations of two groups were successfully completed. The incisions healed by first intention, and no vascular/nerve injury or incision infection occurred. The operation time of group A was significantly longer than that of group B (P<0.05). There was no significant difference in the intraoperative blood loss, hospital stay, and the interval between operation and full weight-bearing (P>0.05). All patients were followed up 12-36 months (mean, 14.8 months). The VAS scores at 48 hours after operation were significantly lower than those before operation in the two groups (P<0.05); there was no significant difference in the difference of pre- and post-operative VAS score between groups (P>0.05). The AOFAS scores at 12 months after operation were significantly higher than those at 3 months after operation in the two groups (P<0.05); and there was no significant difference between groups at 3 and 12 months (P>0.05). X-ray films showed that the fractures of the two groups healed and there was no significant difference in healing time (P>0.05). There was no significant difference in calcaneal length and width and Gissane angle between groups at each time point (P>0.05), but there was significant difference in Böhler angle between groups at 12 months (P<0.05). The imaging indexes of the two groups significantly improved at each time point after operation when compared with those before operation (P<0.05). There was no significant difference between different time points after operation (P>0.05) in the imaging indexes of group A. There were significant differences in the calcaneal length, calcaneal width, and Gissane angle of group B between 12 months and 1 day, 3 months after operation (P<0.05), and there was no significant difference between 1 day and 3 months after operation (P>0.05). The differences in Böhler angle of group B between different time points after operation were significant (P<0.05). There was no significant difference between groups in the loss of all imaging indexes at 3 months after operation (P>0.05). The losses of calcaneal width, Böhler angle, and Gissane angle in group A at 12 months after operation were significantly smaller than those in group B (P<0.05), and there was no significant difference in the loss of calcaneus length between groups (P>0.05). ConclusionCompared with only minimally invasive plate fixation, the combination of minimally invasive plate and medial supporting cannulated screw fixation via tarsal sinus approach for Sanders type Ⅱ and Ⅲ calcaneal fractures has the advantages of less trauma, less incision complications, reliable fracture reduction and fixation, and good long-term stability.