west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "空心螺钉" 29 results
  • TREATMENT OF FEMORAL NECK FRACTURE WITH CANNULATED SCREW FIXATION IN YOUNG ADULTS

    Objective To evaluate the clinical effect of cannulatedscrew on treatment of femoral neck fracture(FNF). Methods Forty-two FNFpatients were treated by using cannulated screw from January 2001 to December 2005.There were 22males and 20 females with an average age of 41 years (19-59 years). Fracture was caused by traffic accident in 21 cases, by falling from height in 14 cases and by bruise in 7 cases. All cases were fresh fracture. According to Garden criterion for typing, 15 cases were classified as type Ⅱ, 16 cases as type Ⅲ and 11 cases as type Ⅳ . It was 7 hours to 15 days from injury to operation. Results Thepatients were followed up for 1-6 years with an average of 2.5 years. The average fracture union time was 6.5 months. Three patients had ischemic necrosis of femoral head, andloosening and breakage of screw and rob was observed in 1 case. According to Brumback criterion for hip joint function, the result was excellent in 18 cases, good in 20 cases and bad in 4 cases, and the excellent and good rate was 90.4%. Conclusion Cannulated screw fixation is a good method to treat FNF in young adults. It can improve the rate of fracture union and reduce the rate of avascular necrosis of femoral head.

    Release date:2016-09-01 09:22 Export PDF Favorites Scan
  • Effectiveness analysis of biplanar vertical fixation and inverted triangle fixation with hollow screw for Pauwels type Ⅲ femoral neck fracture in young and middle-aged patients

    Objective To compare the effectiveness of biplanar vertical fixation and inverted triangle fixation with hollow screw for Pauwels type Ⅲ femoral neck fracture in young and middle-aged patients. Methods The clinical data of 55 young and middle-aged patients with Pauwels type Ⅲ femoral neck fracture between June 2021 and December 2022 was retrospectively analyzed. All patients were treated with closed reduction and internal fixation with hollow screws, 25 cases were treated with biplanar vertical fixation (study group), 30 cases with inverted triangle fixation (control group). There was no significant difference in gender, age, affected side, cause of injury, underlying diseases, and time from injury to operation between the two groups (P>0.05). The operation time, intraoperative blood loss, fluoroscopy times, guide needle puncture times, starting time of weight bearing, time of full weight bearing, time of fracture healing, and complications were recorded and compared between the two groups. The hip joint function was evaluated by Harris score at 1 day, 6 months, 12 months after operation, and at last follow-up, and the pain relief was evaluated by visual analogue scale (VAS) score. The femoral neck shortening was measured on the X-ray film at last follow-up. Results All patients were followed up 12-31 months (mean, 22.0 months), and there was no significant difference in follow-up time between the two groups (P>0.05). The operation time, intraoperative blood loss, and fluoroscopy times in the study group were higher than those in the control group, but the difference was not significant (P>0.05). The guide needle puncture times in the study group was more than that in the control group, and the time of starting weight bearing and the time of full weight bearing in the study group were shorter than those in the control group, the differences were significant (P<0.05). Bony healing was achieved in both groups, and there was no significant difference in fracture healing time between the two groups (P>0.05). No osteonecrosis of the femoral head and incision-related complication was found in the two groups during follow-up, and the femoral neck shortening length in the study group was significantly shorter than that in the control group at last follow-up (P<0.05). There was no significant difference in Harris score between the two groups at 1 day after operation (P>0.05), and the Harris score of the study group was significantly better than that of the control group at other time points (P<0.05); there was no significant difference in VAS score between the two groups at each time point after operation (P>0.05). Conclusion Compared with the inverted triangle fixation, the treatment of Pauwels type Ⅲ femoral neck fracture with biplanar vertical fixation can effectively reduce femoral neck shortening without affecting fracture healing, and improve hip joint function in early stage.

    Release date:2024-08-08 09:03 Export PDF Favorites Scan
  • Hollow screw in treatment of basilar part fracture of hamate hook

    ObjectiveTo explore the effectiveness of hollow screw for the treatment of basilar part fracture of hamate hook.MethodsFive patients with basilar part fracture of hamate hook, aged 24-47 years (mean, 31 years) were treated with open reduction and hollow screw fixation between June 2015 and February 2019. There were 4 males and 1 female. The causes of injury were athletic injury in 3 cases, falling injury in 1 case, and crushing injury in 1 case. Among them, 1 case was combined with sensory disturbance of one and a half fingers on the ulnar side of the palm. The grip strength of the affected side was significantly decreased when compared with that of the healthy side in all patients. The intervals between injury and surgery were 3-8 days (mean, 4.2 days). Postoperative follow-up was conducted regularly to measure the grip strength of the affected and healthy fingers and the total motion of ring and little fingers of the affected side. Darrow criteria was used to evaluate the effectiveness.ResultsAll the incisions healed by primary intention. All the patients were followed up 6-32 months (mean, 16 months). X-ray films showed that the basilar part fracture of hamate hook reached bony union, and the healing time was 2.0-3.5 months (mean, 2.2 months). At last follow-up, the grip strength of the affected side was (35.80±3.76) kg, showing no significant difference when compared with healthy side [(36.00±4.94) kg] (t=0.094, P=0.930); and the total motion of ring and little fingers of the affected side was (529.0±8.9)°, which was significantly different from that before operation [(232.0±34.7)°] (t=18.108, P=0.000). In 1 patient with ulnar nerve injury, the two-point discrimination of the innervation area was 4 mm, and the pain sensation and temperature sensation returned to normal. Assessed by Darrow criteria, the results were excellent in 4 cases and good in 1 case.ConclusionFor the basilar part fracture of hamate hook, hollow screw fixation can obtain secure reduction and fixation and provide sustained compression and counter-rotation for the broken end of fracture, thus allowing early joint motion and promoting fracture healing and recovery of wrist function. It is a relatively good method for the treatment of basilar part fracture of hamate hook.

    Release date:2020-04-29 03:03 Export PDF Favorites Scan
  • PROGRESS IN TREATMENT OF PUBIC SYMPHYSIS DIASTASIS

    ObjectiveTo summarize the progress in treatment of pubic symphysis diastasis. MethodsRelated literature concerning treatment of pubic symphysis diastasis was extensively reviewed and comprehensively analyzed in terms of anatomy, biomechanics, and treatment. ResultsThere are many fixation methods for treatment of pubic symphysis diastasis, which aims at restoring the stability of the anterior pelvic ring. External fixator is often used as a temporary fixation; tension band wire has been abandoned due to its poor biomechanical stability; screw loosening and plate breakage often appears when a single reconstruction plate is used; box plate significantly increases the biomechanical stability of anterior pelvic ring but it leads to a considerable surgical trauma; locking plate has been used for pubic symphysis diastasis recently, especially for osteoporotic fractures; percutaneous cannulated screw has the advantages of less trauma, less bleeding, and good stability, so it is good choice for treatment of pubic symphysis diastasis. ConclusionThere is no uniform standards about the treatment of pubic symphysis diastasis, but the minimally invasive treatment is an undeniable trend. Percutaneous cannulated screw has achieved satisfactory effectiveness, however, its biomechanical stability and anatomic channels need to be further studied.

    Release date: Export PDF Favorites Scan
  • Efficacy of Percutaneous Cannulated Screw versus Plate Fixation for Ankle Fractures: A Meta-analysis

    ObjectiveTo systematically review the efficacy of percutaneous cannulated screw (PCS) versus plate fixation (PF) in the treatment of ankle fractures. MethodsThe Cochrane Library (Issue 5, 2014), PubMed, EMbase, CBM, CNKI, VIP and WanFang Data were searched up to May 28th 2014, for studies concerning the efficacy of percutaneous cannulated screw versus plate fixation for ankle fractures. Two reviewers independently screened literature according to the inclusion and exclusion criteria, extracted data and assessed the methodological quality of included studies. Then, meta-analysis was performed by using RevMan 5.1 software. Result A total of 10 studies (3 RCTs and 7 CCTs) involving 627 patients were included. The results of meta-analysis showed that:compared with the PF group, the PCS group was superior in time of the operation (RCT:MD=-6.78, 95%CI -11.95 to -1.60, P=0.01; CCT:MD=-9.76, 95%CI -13.68 to -5.84, P<0.000 01), blood loss during the operation (RCT:MD=-36.14, 95%CI -40.02 to -32.17, P<0.000 01; CCT:MD=-34.80, 95%CI -37.78 to -31.81, P<0.000 01) and the time of the fracture healing (RCT:MD=-1.16, 95%CI -1.51 to -0.81, P<0.000 01; CCT:MD=-1.55, 95%CI -2.97 to -0.13, P=0.03); However, there were no statistical differences between the two groups in complication rate (CCT:OR=0.48, 95%CI 0.08 to 2.81, P=0.41), AOFAS score excellent rate (RCT:OR=2.11, 95%CI 0.81 to 5.49, P=0.12; CCT:OR=1.58, 95%CI 0.75 to 3.30, P=0.23), and postoperative malleolus pain rate (CCT:OR=0.68, 95%CI 0.00 to 148.82, P=0.89). ConclusionCurrent evidence shows that PCS is superior to PF in shorting time of the operation, reducing blood loss during the operation, and shorting time of the fracture healing. However, the complication rate, AOFAS score excellent rate, and postoperative malleolus pain rate are similar for each operation. Due to the quality limitation of the CCTs, the conclusion are needed to be verified by more high quality RCTs in future.

    Release date: Export PDF Favorites Scan
  • EFFICACY COMPARISON BETWEEN DYNAMIC HIP SCREW COMBINED WITH ANTI-ROTATION SCREW AND CANNULATED SCREW IN TREATING FEMORAL NECK FRACTURES

    Objective To compare the curative effect of dynamic hi p screw (DHS) combined with anti-rotation screw and cannulated screw in treating patients with Pauwels type II or III femoral neck fracture and to provide the basis for the choice of surgical procedure. Methods Between March 2008 and September 2009, 51 patients with fresh Pauwels type II or III femoral neck fracture were treated with DHS combined with anti-rotation screw (DHS group) and three cannulated screws (cannulated screw group). The DHS group included 23 patients, 13 males and 10 females, aging 27-59 years (mean, 43.2 years); fracture was caused by fall ing in 1 case, by traffic accident in 17, by fall ing from height in 5 with a mean time of 27 hoursfrom injury to hospital ization (range, 12-70 hours); and 23 fractures included 9 Pauwels type II and 14 Pauwels type III femoral neck fracture. The cannulated screw group included 28 patients, 12 males and 16 females, aging 20-60 years (mean, 40.7 years); fracture was caused by fall ing in 1 case, by traffic accident in 22, by fall ing from height in 5 with a mean time of 25 hours from injury to hospital ization (range, 9-38 hours); and 28 fractures included 12 Pauwels type II and 16 Pauwels type III femoral neck fracture. There was no significant difference in the basel ine characteristics between 2 groups (P gt; 0.05). Results The incision heal ing of both groups by first intention was achieved. There were significant differences in operation time, incision size, operation blood loss, the cases of blood transfusion, the amount of blood transfusion, C reaction protein level on the 2nd postoperative day, and hospital ization days between 2 groups (P lt; 0.05). In DHS group, anatomic reduction was observed in 20 cases (86.96%) and satisfactory reduction in 3 cases (13.04%), while in cannulated screw group, anatomic reduction was observed in 25 cases (89.29%) and satisfactory reduction in 3 cases (10.71%) ; there was no significant difference (χ2=0.660, P=1.000). The patients were followed up 12-30 months with an average of 14.8 months. There was no significant difference (P gt; 0.05) in the rate of nonunion (10.71% vs. 0), the implant failure (3.57% vs. 0), and avascular necrosis of the femoral head (10.71% vs. 0) between the DHS group and the cannulated screw group. The union time was (94.5 ± 2.0) days in the DHS group and (106.0 ± 33.5) days in the cannulated screw group, showing no significant difference (t=—1.641, P=0.107). The re-opereation rates and the overall success rates were 25% and 75% in the cannulated group and were 0 and 100% in the DHS group, showing significant differences (χ2=6.650, P=0.012). At last follow-up, there was no significant difference in Harris hip score and visualanalogue scale (VAS) score between DHS group and cannulated screw group (P gt; 0.05). Conclusion The optimal treatment of young adults Pauwels type II or III femoral neck fracture is DHS combined with anti-rotation screw with an high overall success and less compl ications.

    Release date:2016-08-31 05:41 Export PDF Favorites Scan
  • CLINICAL RESEARCH OF INDIVIDUAL PERCUTANEOUS CANNULATED SCREWS FIXATION FOR TREATMENT OF Herbert TYPE Ib SCAPHOID FRACTURE

    ObjectiveTo investigate the effectiveness of individual percutaneous cannulated screws fixation of computer-assisted design combined with three-dimensional (3D) guide plate by comparing with cast immobilization and open internal fixation for treatment of Herbert type Ib scaphoid fracture. MethodsBetween January 2010 and June 2015, 56 patients with fresh Herbert type Ib scaphoid fracture were treated with cast immobilization in 16 cases (external fixation group), with open reduction and internal fixation in 20 cases (open reduction group), and with individual percutaneous cannulated screws fixation of computer-assisted design combined 3D guide plate in 20 cases (minimal invasion group). There was no significant difference in gender, age, injury cause, side, disease duration, and classification of fractures between groups P>0.05).The time of bone union, bone nonunion rate, return-to-work time, wrist range of motion (ROM), and Mayo function score were recorded and compared. ResultsPrimary healing of incision was obtained in open reduction group and minimally invasion group, without related complications. The cases were followed up 10-24 months (mean, 16.6 months). The time of bone union and return-to-work time of minimal invasion group were significantly shorter than those of the other 2 groups (P<0.05), and the rate of bone nonunion was significantly lower than that of the other 2 groups (P<0.05). At last follow-up, the wrist ROM of minimal invasion group[(104.40±3.46)°] was significantly larger than that of external group[(94.20±2.42)°] and open reduction group[(96.40±2.66)°] (P<0.05). According to Mayo function score, the results were excellent in 6 cases, good in 5 cases, fair in 2 cases, and poor in 3 cases in external fixation group, with an excellent and good rate of 69%; the results were excellent in 9 cases, good in 7 cases, fair in 2 cases, and poor in 2 cases in open reduction group, with an excellent and good rate of 80%; the results were excellent in 16 cases, good in 3 cases, and fair in1 case in minimal invasion group, with an excellent and good rate of 95%; there was significant difference in excellent and good rate among groups (P<0.05). ConclusionIndividual percutaneous cannulated screws fixation of computer-assisted design combined with 3D guide plate has satisfactory effectiveness in the treatment of Herbert type Ib scaphoid fractures, with the advantages of mini-invasion, high accuracy, high rate of bone union, less complication, early return-to-work time.

    Release date:2016-10-21 06:36 Export PDF Favorites Scan
  • Effectiveness of vertical compression of locking plate combined with hollow screws in treatment of Sanders type Ⅱ and Ⅲ calcaneal fractures

    Objective To probe into the effectiveness of vertical compression of locking plate combined with hollow screws in the treatment of Sanders type Ⅱ and Ⅲ calcaneal fractures. MethodsThe clinical data of 128 patients with Sanders type Ⅱ and Ⅲ calcaneal fractures who were admitted between March 2019 and April 2022 and met the selection criteria were retrospectively analyzed. Among them, 65 patients were treated with locking plate combined with hollow screw vertical compression (study group), and 63 patients were treated with simple locking plate (control group). There was no significant difference in baseline data between the two groups (P>0.05), such as gender, age, fracture side and Sanders classification, cause of injury, time from injury to operation. The operation time, intraoperative blood loss, hospital stay, and fracture healing time were recorded and compared between the two groups. Before operation and at 12 months after operation, the American Orthopaedic Foot and Ankle Association (AOFAS) score (including total score, pain score, functional score, and alignment score) was used to evaluate the recovery of foot function, and imaging indicators such as calcaneal width, calcaneal height, calcaneal length, Böhler angle, and Gissane angle were measured on X-ray films. ResultsAll patients were followed up 12 months after operation. There was no significant difference in operation time, intraoperative blood loss, hospital stay, and fracture healing time between the two groups (P>0.05). Poor wound healing occurred in 1 case in the study group and 2 cases in the control group. At 12 months after operation, there was no significant difference between the two groups in the pre- and post-operative difference of calcaneal length, calcaneal height, Gissane angle, and Böhler angle (P>0.05). However, the pre- and post-operative difference in calcaneal width in the study group was significantly higher than that in the control group (P<0.05). The pre- and post-operative difference of AOFAS total score in the study group was significantly higher than that in the control group (P<0.05), and further analysis showed that the pre- and post-operative difference of pain and function scores in the study group were significantly higher than those in the control group (P<0.05), while there was no significant difference in the pre- and post-operative difference of force score between the two groups (P>0.05). ConclusionCompared with simple locking plate treatment, the treatment of Sanders type Ⅱ and Ⅲ calcaneal fractures with vertical compression of locking plate combined with hollow screws can more effectively improve the width of the subtalar calcaneal articular surface, avoid peroneal longus and brevis impingement, reduce pain, and increase the range of motion of the subtalar joint, and the effectiveness is better.

    Release date:2024-05-13 02:25 Export PDF Favorites Scan
  • TiRobot-assisted percutaneous sacroiliac cannulated screw fixation for posterior pelvic ring injury with sacral variations

    ObjectiveTo investigate the effectiveness of TiRobot-assisted percutaneous sacroiliac cannulated screw fixation in the treatment of posterior pelvic ring injuries with sacral variations, and to evaluate its feasibility and safety. Methods The clinical data of 7 patients with Tile type C pelvic fractures and sacral variations treated with TiRobot-assisted percutaneous sacroiliac cannulated screw fixation between January 2020 and June 2021 were retrospectively analyzed. There were 5 males and 2 females with an average age of 36 years (range, 17-56 years). The causes of injury were traffic accident in 4 cases and falling from height in 3 cases. According to Tile classification of pelvic fractures, there were 1 case of type C1.1, 1 case of type C1.2, and 5 cases of type C1.3; according to Denis classification of sacral fractures, there were 3 cases of zone Ⅰ and 4 cases of zone Ⅱ; sacral deformities included 3 cases of lumbar sacralization, 2 cases of sacral lumbarization, and 2 cases of accessory auricular surface of the sacrum. The time from injury to operation ranged from 2 to 7 days, with an average of 4.6 days. The implantation time of each screw, the fluoroscopy times of each guide pin, the quality of fracture reduction (according to Matta score), the excellent and good rate of screw position, the healing time of fracture, and the incidence of complications were recorded, and the effectiveness was evaluated by Majeed score. Results A total of 13 screws were implanted during the operation, the implantation time of each screw was 10-23 minutes, with an average of 18.2 minutes; the position of the guide pin was good, and no guide pin was adjusted, the fluoroscopy times of each guide pin were 3-7 times, with a median of 4 times. Postoperative imaging data at 3 days showed that the position of sacroiliac screw implantation was evaluated as excellent. No complication such as incision infection or vascular nerve injury occurred, and no adverse events related to robotic devices occurred. At 3 days after operation, according to Matta score, the quality of fracture reduction was excellent in 6 cases and good in 1 case, and the excellent and good rate was 100%. All the 7 patients were followed up 6-15 months, with an average of 12.4 months. Bone union was achieved in all patients, and the healing time ranged from 18 to 24 weeks, with an average of 21.2 weeks. Majeed score at last follow-up was 81-95, with an average of 91.5; 5 cases were excellent, 2 cases were good, and the excellent and good rate was 100%. ConclusionTiRobot-assisted percutaneous sacroiliac cannulated screw fixation for posterior pelvic ring injury with sacral variation is accurate, safe, minimally invasive, and intelligent, and the effectiveness is satisfactory.

    Release date:2022-08-29 02:38 Export PDF Favorites Scan
  • Different Treatments for 29 Cases of Femoral Neck Fracture in Elder People

    目的:总结空心螺钉、DHS或人工关节置换治疗股骨颈骨折的适应证及效果。方法:分别用空心螺钉、DHS固定和人工关节置换3种方法治疗获得随访的中老年股骨颈骨折29例。年龄51~85岁,平均68.3岁。空心螺钉组8例,DHS组15例,人工关节组6例。结果:随访29例,随访时间1~3年,平均2~3年。围手术期无1例死亡,无切口感染,无内固定断裂,无关节脱位。发生退钉2例,股骨头坏死1例。功能评定:优20例,良6例,差3例。结论:根据患者的年龄、经济状况、骨折部位、骨折分型合理地选择治疗方法,是减少并发症,提高治疗效果和老年人生活质量的关键。

    Release date:2016-09-08 10:02 Export PDF Favorites Scan
3 pages Previous 1 2 3 Next