Objective To explore the application value of infrared thermography in the design and harvesting of ultrathin anterolateral thigh perforator flaps. Methods Between June 2024 and December 2024, 9 cases of ultrathin anterolateral thigh perforator flaps were designed and harvested with the assistance of infrared thermography. There were 7 males and 2 females, aged 21-61 years (mean, 39.8 years). The body mass index ranged from 19.49 to 26.45 kg/m² (mean, 23.85 kg/m²). Causes of injury included 5 cases of traffic accident injuries and 4 cases of machine crush injuries. There were 3 cases of leg wounds, 2 cases of foot wounds, and 4 cases of hand wounds. After debridement, the size of wound ranged from 7 cm×4 cm to 13 cm×11 cm. The time from admission to flap repair surgery was 5-12 days (mean, 7 days). Preoperatively, perforator localization was performed using a traditional Doppler flow detector and infrared thermography, respectively. The results were compared with the actual intraoperative locations; a discrepancy ≤10 mm was considered as consistent localization (positive), and the positive predictive value was calculated. All 9 cases were repaired with ultrathin anterolateral thigh perforator flaps designed and harvested based on thermographic images. The size of flap ranged from 8 cm×5 cm to 14 cm×8 cm, with a thickness of 3-6 mm (mean, 5.2 mm). One donor site was repaired with a full-thickness skin graft, and the others were sutured directly. Postoperatively, anti-inflammatory, anticoagulant, and anti-vascular spasm treatments were administered, and follow-up was conducted. ResultsThe Doppler flow detector identified 22 perforating vessels within the set range, among which 16 were confirmed as superficial fascia layer perforators intraoperatively, with a positive predictive value of 72.7%. The infrared thermograph detected 23 superficial fascia layer perforating vessels, and 21 were verified intraoperatively, with a positive predictive value of 91.3%. There was no significant difference between the two methods [OR (95%CI)=3.93 (0.70, 22.15), P=0.100]. The perforator localization time of the infrared thermograph was (5.1±1.3) minutes, which was significantly shorter than that of the Doppler flow detector [(10.1±2.6) minutes; MD (95%CI)=–5.00 (–7.08, –2.91), P<0.001]. Postoperatively, 1 case of distal flap necrosis healed after dressing change; all other flaps survived successfully. The skin grafts at donor site survived, and all incisions healed by first intention. All patients were followed up 3-6 months (mean, 4.7 months). No pain or other discomfort occurred at the donor or recipient sites. All patients with foot wounds could walk with shoes, and no secondary flap revision was required. Flaps in 3 hand wound cases, 2 foot wound cases, and 3 leg wound cases recovered light touch and pressure sensation, but not pain or temperature sensation; the remaining 2 cases had no sensory recovery.ConclusionPreoperative localization using infrared thermography for repairing ultrathin anterolateral thigh perforator flaps can help evaluate the blood supply status of perforators, reduce complications, and improve surgical safety and flap survival rate.
【Abstract】Objective To estimate the value of the infra-red light scanning and the colored ultrasonic Doppler in diagnosis of breast masses. Methods Two hundred and seventy nine patients with breast mass were examined with the infrared light scanning and the colored ultrasonic Doppler in our hospital.Following the two examinations the masses were resected and pathologically examined as a control. Results The conformity of the infra-red light scanning with pathologic diagnosis was 94.0% in 182 hyperplasia masses, while that of the ultrasonic Doppler was 84.6%(P<0.01). The conformity of the infra-red light scanning with pathology was 91.7% and that of the colored ultrasonic Doppler was 83.3%(Pgt;0.05). The colored ultrasonic Doppler was seemingly more effective than infrared light scanning in diagnosing 9 galactocele and 5 intraductal papilloma, but there is no significant difference(Pgt;0.05). The conformity of the two exams with pathology in 59 fibroadenoma was almost the same.Conclusion The infra-red light scanning is more effective than the colored ultrasonic Doppler in diagnosing the hyperplasia masses, there is no significant difference in diagnosing the breast cancer and the fibroadenoma between the two exams. Combined use of this two exams would increase the accurase of the breast masses.
In order to observe the effect of far infrared rays on the survival of skin flap, the following experiment was performed. Forty-eight SD rats were selected and divided into two groups. The rats received 0.3 w/cm2 radiation twice a day from 3 days before operation to 5 days after operation in the experimental group, while in the control group the rats received none before or after the operation. The flap was designed as 2 cm x 6 cm in the back of the rats with the pedicle caudalward. The microcirculatory changes of the flap were observed, and the survival area of the flap was calculated. The results showed that either in the proximal or in the distal part of the graft, in the experimental group, the mean opening rate, diameter and the flowing velocity of the microvessels were significantly higher than those in the control group (P lt; 0. 05). The mean rate of survival area of the experimental group (80.5%) was also higher than that of the control group (62.7%) (P lt; 0.01). It was suggested that radiation with far infrared rays could dilate the microvessels, improve the flap microcirculation, therefore, enhance the survival of the randomized skin flap.