west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "组织工程骨" 68 results
  • HISTOLOGICAL OBSERVATION OF BIODERIVED BONE PREPARED BY DIFFERENTMETHODS AFTER IMPLANTATION

    Objective To explore the histological changes of bio-derived bone prepared by different methods after implantation, and to provide the scaffold material from xenogeneic animal for tissue engineering. Methods Theextremities of porcine femur were cut into 0.5 cm×0.5 cm×0.5 cm. Then they were divided into 5 groups according to different preparation methods: group A was fresh bone just repeatedly rinsed by saline; group B was degreased; group C was degreased and decalcificated; group D was degreased, acellular and decalcificated; group E wasdegreased and acellular. All the materials were implantated into femoral muscle pouch of rabbit after 25 kGy irradiation sterilization. The cell counting ofinflammatory cells and osteoclasts, HE and Masson staining, material degradation, collagen and new bone formation were observed at 2, 6, and 12 weeks postoperatively. Results The residue level of trace element in biomaterials prepared by different methods is in line with the standards. All the animals survived well. There were no tissue necrosis, fluid accumulation or inflammation at all implantation sites at each time point. The inflammatory cells counting was most in group A, and there was significant difference compared with other groups(P<0.05). There was no significant difference in osteoclasts counting among all groups. For the index of HE and Masson staining, collagen and new bone formation, groups C and D were best, group E was better, and groups A and B were worse. Conclusion The degreased, acellular and decalcificated porcine bone is better in degradation,bone formation, and lower inflammatory reaction, it can be used better scaffold material for tissue engineered bone.

    Release date:2016-09-01 09:23 Export PDF Favorites Scan
  • PREPARATION AND DEGRADATION CHARACTERISTICS OF BONE REPAIR COMPOSITE--PDLLA/HA/DBM

    OBJECTIVE: To explore a new method of preparing the composite of DL-polylactic acid (PDLLA), hydroxyapatite(HA), decalcium bone matrix (DBM), and to observe the degradation characteristics of PDLLA/HA/DBM in vitro. METHODS: An emulsion blend method was developed to prepare the composite of PDLLA/HA/DBM based on the weight rate of PDLLA:HA:DBM = 1.5-2:1-1.5:1. The characteristics of the particles was observed by scanning electron microscope. In vitro, PDLLA/HA/DBM and PDLLA were put into PBS(pH7.4) respectively; the pH value, weight and biomechanics of them were determined during the degradation. RESULTS: Without heating, the emulsion blend method could be developed to prepare PDLLA/HA/DBM. Scanning electron microscope showed that the gap diameter in the compound material was 100 to 400 microns, and the porosity was 71.3%; During degradation, the pH value of PDLLA decreased little within 2 weeks, then decreased obviously and decreased to 4.0 at the end of the 4th week; while the pH value of PDLLA/HA/DBM kept quite steady and was 6.4 at the end of the 12th week. The weight of PDLLA decreased little within 4 weeks, then decreased obviously and remained 50% of its prime weight at the end of the 12th week; while the weight of PDLLA/HA/DBM decreased little within 5 weeks, then decreased obviously and remained 60% of the prime at the end of the 12th week. The prime biomechanical strength was 1.33 MPa in PDLLA and 1.71 MPa in PDLLA/HA/DBM. There was significant difference between them (P lt; 0.05). The strength of PDLLA decreased little within 3 weeks, then decrease obviously and was 0.11 MPa at the end of the 12th week; the strength of PDLLA/HA/DBM decreased little within 4 weeks, then decrease obviously and was 0.21 MPa at the end of the 12th week. CONCLUSION: The emulsion blend method is a new method to prepare bone repair materials. As a new bone repair material, PDLLA/HA/DBM is suitable for bone tissue engineering for its good characteristics of porosity and degeneration.

    Release date:2016-09-01 09:35 Export PDF Favorites Scan
  • STUDY ON BIOCOMPATIBILITY OF A NEW EXTRACELLULAR MATRIX MATERIAL WITH TISSUE ENGINEERING METHODS

    Objective To evaluate the biocompatibility of a new bone matrix material (NBM) composed of both organic and inorganic materials for bone tissue engineering. Methods Osteoblasts combined with NBM in vitro were cultured. The morphological characteristics was observed; cell proliferation, protein content and basic alkaline phosphatase(ALP) activity were measured. NBM combined with osteoblasts were implanted into the skeletal muscles of rabbits and the osteogenic potential of NBM was evaluated through contraat microscope, scanning electromicroscope and histological examination. In vitro osteoblasts could attach and proliferate well in the NBM, secreting lots of extracellular matrix; NBM did not cause the inhibition of proliferation and ALP activity of osteoblasts. While in vivo experiment of the NBM with osteoblasts showed that a large number of lymphacytes and phagocytes invading into the inner of the material in the rabbit skeletalmuscle were seen after 4 weeks of implantation and that no new bone formation was observed after 8 weeks. Conclusion This biocompat ibility difference between in vitro and in vivo may be due to the immunogenity of NBM which causes cellular immuno reaction so as to destroy the osteogenic environment. The immunoreaction between the host and the organic-inorganic composite materials in tissue engineering should be paid more attention to.

    Release date:2016-09-01 09:35 Export PDF Favorites Scan
  • CLINICAL APPLICATION OF BIO-DERIVED BONE TRANSPLANTATION WITH TISSUE ENGINEERINGTECHNIQUE:YEAR FOLLOW-UP

    To summarize the medium-term cl inical result of bio-derived bone transplantation in orthopedics with tissue engineering technique. Methods From December 2000 to June 2001, 10 cases of various types of bone defect were treated with tissue engineered bone, which was constructed in vitro by allogenous osteoblasts from periosteum (1 × 106/ mL) with bio-derived bone scaffold following 3 to 7 days co-culture. Six men and 4 women were involved in this study, aged from 14 to 70 years with a median of 42 years. Among them, there were 2 cases of bone cyst, 1 case of non-union of old fracture, 6 cases of fresh comminuted fracture with bone defect, and 1 case of chronic suppurative ostemyel itis. The total weight of tissue engineered bone was 3-15 g in all the cases, averaged 7.3 g in each case. Results The wound in all the case healed by first intention. For 7 year follow up, bone union was completed within 3.0 to 4.5 months in 9 cases, but loosening occurred and the graft was taken out 1 year after operation in 1 case. The X-ray films showed that 9 cases achieved union except one who received resection of the head of humerus. No obvious abnormities were observed, and the function of affected l imbs met daily l ife and work. Conclusion Bio-derived tissue engineered bone has good osteogenesis. No obvious rejection and other compl ications are observed in the cl inical appl ication.

    Release date:2016-09-01 09:12 Export PDF Favorites Scan
  • EFFECTS OF IMPACTION ON TISSUE ENGINEERED BONE MODIFIED BY BMP-2 GENE

    Objective To observe effects of the direct impaction onthe cell survival and the bone formation of the tissue engineered bone modified by the adenovirus mediated human bone morphogenetic protein 2 (Adv-hBMP2) gene and to verify the feasibility of the impacted grafting with it. Methods The marrow stromal cells (MSCs) were separated from the canine bone marrow and were cultured. MSCs were transfected with the Adv-hBMP2 gene and combined with the freeze-dried cancellous bone (FDB) to form the tissue engineered bone. Four days after the combination, the tissue engineered bone was impacted in a simulated impactor in vitro and implanted in the mouse. The cell survivals were evaluated with SEM 1 and 4 days after the combination, immediately after the impaction, and 1 and 4 days after the impaction, respectively. The bone formation and the allograft absorption were histologically evaluated respectively. Results There were multiple layers of the cells and much collagen on FDB before the impaction. Immediately after the impaction, most of the cells on the direct contact area disappearedand there was much debris on the section. Some of the cells died and separatedfrom the surface of FDB at 1 day, the number of the cells decreased but the collagen increased on the surface at 4 days. Histologically, only the fibrous tissue was found in FDB without the cells, the bone formation on FDB was even in distribution and mass in appearance before the impaction, but declined and was mainly on the periphery after the impaction in the AdvhBMP2 modified tissue-engineered bone. Conclusion The simulated impaction can decrease the cells survival and the bone formation of the AdvhBMP-2 modified tissue-engineered bone. The survival cells still function well.It is feasible to use the tissue engineered bone in the impaction graft.

    Release date:2016-09-01 09:25 Export PDF Favorites Scan
  • CONSTRUCTION OF CARRIER FOR BONE TISSUE ENGINEERING WITH DIFFERENT CONCENTRATIONS OF ALGINATE CONBINED WITH XENOGRAFT

    Objective To investigate bio characteristics of bone stromal cells (MSC) in different concentrations of alginate combined with xenograft. Methods The configuration and secretion of MSC in different concentrations of alginate combined with xenograft were observed by scanning electron microscope and inverted microscope. Results When the concentration of alginate was 0.25% or 1%, alginate was equally combined in xenograft, 4% and 8% only on the surface of xenograft. After cultured for 4 days, alginate of 0.25# came off from xenograft. But alginate of 1% was equally combined in xenograft with cell secreting well in alginate. The growth of cells in alginate of 4% was restricted and no cell was seen in alginate of 8%. Conclusion Alginate of 1% is suitable fro constructing carrier of tissue engineering bone.

    Release date:2016-09-01 09:35 Export PDF Favorites Scan
  • STUDIES OF PREPARATION, MORPHOLOGY AND IN VITRO RELEASE ON BIODERIVED MATERIAL-WO-1 DELIVERY SYSTEM

    Objective To study the potential of a bioderived material combined with Pluronic F-127 in vitro as a delivery vehicle for WO-1 in the bone repair therapy. Methods Bio-derived materials were fabricated and loaded with WO-1 by Pluronic F-127. Micromorphology and porosity were detected by the scanning electron microscope and the digital image analysis system respectively. The WO-1 release from the system in vitro was studied by the high performance liquid chromatography. Results Bio-derived material-WO-1 drug delivery systems were created with the interconnected pore network. Theporosity and pore size of the system were 55% and 522.43±16.75 μm respectively, compared with those of bio-derived materials, which were 75% and 623.67±12.31 μm respectively. And the main composition of the system was HA. The in vitrorelease kinetics of WO-1 revealedthat an effective therapeutic concentration(0.2-0.8 μg/ml) of WO-1 was maintained for 6 days after a high initial burst release. Conclusion The bio-derived material-WO-1 drug delivery system can be used in the bone repair therapy. However, the in vivostudy on it is still needed.

    Release date:2016-09-01 09:24 Export PDF Favorites Scan
  • EFFECT OF ENDOTHELIAL PROGENITOR CELLS IN PROMOTING OSTEOGENESIS OF TISSUE ENGINEERED BONE IN VIVO

    ObjectiveTo investigate the ability of autologous peripheral blood endothelial progenitor cells (EPCs) in promoting neovascularization of tissue engineered bone and osteogenesis of bone marrow mesenchymal stem cells (BMSCs). MethodThe peripheral blood EPCs and BMSCs from No. 1-9 New Zealand rabbits were isolated, cultured, and identified. According to the cell types, the third generation of cells were divided into 3 groups:EPCs (group A), BMSCs (group B), and co-cultured cells of EPCs and BMSCs (group C, EPCs:BMSCs=1:2) . Then cells were seeded on the partially deproteinised bone (PDPB) packaged with fibronectin to construct tissue engineered bone. After 4 days, autologous heterotopic transplantation of tissue engineered bone was performed in the rabbit's muscles bag of groups A, B, and C (the right arm, left arm, right lower limb respectively, 2 pieces each part). At 2, 4, and 8 weeks after transplantation, the growth of tissue engineered bone was observed, and the rate of bone ingrowth was calculated by HE staining; the expressions of CD34, CD105, and zonula occludens protein 1(ZO-1) were compared by immunohistochemical staining at each time point in tissue engineered bone among 3 groups. ResultsThe EPCs and BMSCs were isolated and identified successfully; immunofluorescent staining showed that EPCs were positive for CD34, CD133, and von Willebrand factor (vWF), and BMSCs were positive for CD29 and CD90 and were negative for CD34. The tissue engineered bone constructed in 3 groups was transplanted successfully. At 2, 4, and 8 weeks after autologous heterotopic transplantation, the general observations showed that the soft tissue around the tissue engineered bone increased and thickened gradually in each group with time passing; the boundary between bone and soft tissue was not clear; the pore space of tissue engineered bone gradually was filled, especially in group C, the circuitous vascular network could be seen in the tissue engineered bone. HE staining showed capillaries and collagen fibers increased gradually, tissue engineered bone ingrowth rate was significantly higher in group C than groups A and B at 4 and 8 weeks (P<0.05) , and group B was significantly higher than group A (P<0.05) . Immunohistochemical staining showed that the expressions of CD34, CD105, and ZO-1 in tissue engineered bone of 3 groups all increased with the extension of time, showing significant differences between groups at each time point (P<0.05) . At 2 weeks after transplantation, the expression of CD105 in group C was significantly higher than that in groups A and B (P<0.05) ; at 4 and 8 weeks, CD34, CD105, and ZO-1 expressions showed significant differences between 2 groups (P<0.05) ; the expression was the highest in group C, and was the lowest in group B. ConclusionsAutologous peripheral blood EPCs and BMSCs have synergistic effect, and can promote neovascularization and osteogenesis of tissue engineered bone in vivo.

    Release date: Export PDF Favorites Scan
  • EXPERIMENTAL STUDY ON CELL ADHESION CHARACTERISTIC BETWEEN POROUS BIPHASIC CALCIUM PHOSPHATE NANOCOMPOSITE AND BONE MARROW MESENCHYMAL STEM CELLS IN VITRO

    Objective To study the adhesion characteristic in vitrobetween porous biphasic calcium phosphate(BCP) nanocomposite and bone marrow mesenchymal stem cells (MSCs) that have been induced and proliferated. Methods MSCs obtained from SD ratbone marrow were in vitro induced and proliferated. After their osteoblastic phenotype were demonstrated, MSCs were seeded onto prepared porous BCP nanocomposite(experiment group)and common porous hydroxyapatite (control group). Their adhesion situation was analyzed by scanning electron microscope. The initial optimal cell seeding density was investigated between new pattern porous BCP nanocomposite and MSCs by MTT automated colormetric microassay method. Results The differentiation of MSCs to osteoblastic phenotype were demonstrated by the positive staining of mineralized node, alkaline phosphatase (ALP) and collagen typeⅠ, the most appropriate seeding density between them was 2×106/ml. The maximal number which MSCs could adhere to porous BCP nanocomposite was 1.28×107/cm3. Conclusion MSCs can differentiate to osteoblastic phenotype.The MSCs were well adhered to porous BCP nanocomposite.

    Release date:2016-09-01 09:26 Export PDF Favorites Scan
  • RADIOLOGICAL STUDY ON REPAIR OF GOAT TIBIA DEFECT WITH MARROW STROMAL STEM CELLS AND BIODERIVED BONE

    Objective To investigate the ability to repair goat tibia defect with marrow stromal stem cells (MSCs) and bio-derived bone, and the feasibility of the compounds as bone substitute material. Methods MSCs were cultured with the bioderived bone in vitro, and the 20 mm tibia defect of goat was made and fixedwith plate. Eighteen goats were divided into experimental group, control group and blankgroup. The defects were not filled with anything in blank group, with tissue engineering bone in experimental group and bio-derived bone in control group. Therepair capability was assessed by physical, X-ray and bone mineral density examinations8,12,16, and 24 weeks after operation. Results In experimental group, the defects were partially repaired 8 weeks, and completely repaired12 and 16 weeks; there was significant difference in bone density between experimental group and control group (P<0.05) 8,12 and 16 weeks, but no significant difference 24 weeks. The defects of blank group were not repaired 24weeks. Conclusion The tissue engineering bone can efficiently repair bone defect, and its repair capability is better than that of bio-derived bone alone both in quantity and quality of boneformation.

    Release date:2016-09-01 09:33 Export PDF Favorites Scan
7 pages Previous 1 2 3 ... 7 Next

Format

Content