ObjectiveTo systematically review the value of the fine-needle biopsies in the diagnosis of benign and malignant breast nodules. MethodsA computer based online search was conducted in PubMed, The Cochrane Library (Issue 7, 2016), EMbase, CBM, CNKI, VIP, WanFang Data databases up to August, 2016 to collect the relevant diagnostic studies of the fine-needle biopsies for benign and malignant breast nodules. Two reviewers independently screened literature, extracted data and assessed the methodological quality of included studies. Then, meta-analysis was performed using Stata 12.0 and Meta-Disc 1.4 software.ResultsA total of 22 studies involving 24 496 patients were finally included. The results of meta-analysis showed that the pooled Sen, Spe, +LR, –LR, and DOR were 0.95 (95%CI 0.95 to 0.96), 0.96 (95%CI 0.96 to 0.96), 38.27 (95%CI 23.17 to 63.19), 0.05 (95%CI 0.03 to 0.07), 1 031.11 (95%CI 514.19 to 2 067.68), respectively. The AUC of SROC was 0.99 (95%CI 0.98 to 1.00).ConclusionThe current evidence indicates that the FNAC has high diagnostic value in the differential diagnosis of benign and malignant breast nodules.
ObjectiveTo assess the effect of the size of thyroid nodules on the diagnostic rate of ultrasound guided aspiration cytology (US-FNAB). MethodsThe data of 1 142 (performed by two doctors, 571 each) thyroid nodules between March 2011 and April 2014 in our hospital were retrospectively analyzed. Yields of US-FNAB were divided into two levels of adequacy and inadequacy according to the classification standard of the Bethesda system. The thyroid nodules were classified into five groups according to the largest diameter:≤5 mm group, 5-10 mm group,10-20 mm group, 20-30 mm group, and <30 mm group. According to the grouping of the nodules and the efficiency of US-FNAB drawed curve, the adequacy rates of alone and total of two examiners in each group were analyzed, respectively. ResultsThe adequacy rates of US-FNAB of alone and total of two examiners in≤5 mm group, 5-10 mm group,10-20 mm group, 20-30 mm group, and <30 mm group was 68.42%, 83.72%, 86.08%, 84.62%, and 73.53% (examiner 1); 68.75%, 70.53%, 81.05%, 86.15%, and 73.91% (examiner 2); 68.59%, 77.53%, 83.59%, 85.47%, and 73.75% (total of two examiners), respectively. The total adequacy rate of US-FNAB of two examiners in≤5 mm group was lower than that in 10-20 mm group (P<0.001) and 20-30 mm group (P=0.001). The adequacy rate of US-FNAB of examiner 1 in 5-10 mm group was higher than that examiner 2 (P=0.001). ConclusionsThe size of thyroid nodules significantly influences the adequate diagnostic rate of US-FNAB. The adequacy rates of US-FNAB of the largest diameter≤5 mm or <3mm were lower. The low adequacy rate of US-FNAB may be associated with cystic degeneration in the larger nodules.
Objective To summarize the significance of BRAFV600E mutation for the diagnosis, treatment, and prognosis of papillary thyroid cancer (PTC). Methods Related literatures which were published in recent years for exploring the relationship of BRAFV600E mutation and PTC were collected and reviewed. Results The BRAFV600E mutation was the most common mutant type in PTC, which played an important role in the oncogenesis and development of PTC. In addition, this type of mutation was closely associated with aggressive behavior and poor prognosis of PTC. The BRAFV600E testing in fine needle aspiration (FNA) samples of thyroid nodule not only facilitated to improve the diagnostic accuracy of PTC, but also helped ensure the recurrence risk classification, selection of surgical treatment, and follow-up planning. Conclusion BRAFV600E mutation was prevalent in PTC and had important significance both in diagnosis and prognostic evaluation of PTC.
ObjectiveTo evaluate the diagnostic value of BRAFV600E mutation test in high-risk thyroid nodules with easily underdiagnosed fine-needle aspiration biopsy (FNAB) results.MethodsRetrospectively collected 122 cases of thyroid nodule who treated in the Hebei Petrochina Central Hospital between January 2017 and December 2018, all the cases admitted preoperative ultrasound and FNAB detection. All of the patients had the non-positive cytological results of FNAB and the high-risk features of ultrasound. Contrasted the postoperative pathological coincidence rate of combination of FNAB and BRAFV600E test with FNAB alone.ResultsThe BRAFV600E mutation rate was 27.0% (33/122). The positive rate of BRAFV600E mutation increased with the increase of ultrasound thyroid imaging reporting and data system(TI-RADS) grade (P<0.05), which was independent of patients’ age, gender, number of nodules, diameter of nodules, and FNAB results (P>0.05). The coincidence rate of FNAB combined with BRAFV600E mutation detection was higher than that of FNAB alone [86.9% (106/122) vs. 69.7% (85/122), P<0.05).ConclusionsThe BRAFV600E mutation test can detect papillary thyroid carcinoma that might be missed by FNAB. We recommend that FNAB should be routinely accompanied by the BRAFV600E mutation test in the high-risk thyroid nodules.
Objective To investigate the diagnostic significance of fine needle aspiration cytology (FNAC) combined with BRAFV600E gene detection in the diagnosis of cervical lymph node metastasis of thyroid cancer. Methods Atotal of 140 patients with suspected cervical lymph node metastasis of thyroid cancer were collected as the research objects, and all patients were given ultrasound-guided FNAC and detection of BRAFV600E gene. The significance of the diagnosis was analyzed according to the gold standard after pathological examination. Results All the 140 patients underwent surgical treatment. For FNAC, the sensitivity was 63.6% (84/132), the specificity was 100% (8/8), the accuracy was 65.7% (92/140), the positive predictive value was 100% (84/84), and the negative predictive value was 14.3% (8/56). For detection of BRAFV600E gene, the sensitivity was 84.8% (112/132), the specificity was 100% (8/8), the accuracy was 85.7% (120/140), the positive predictive value was 100% (112/112), and the negative predictive value was 28.5% (8/28). For FNAC combined with BRAFV600E gene detection, the sensitivity was 90.9% (120/132), the specificity was 100% (8/8), the accuracy was 91.4% (128/140), the positive predictive value was 100% (120/120), and the negative predictive value was 40.0% (8/20). The area under curve of receiver operating characteristic for FNAC, detection of BRAFV600E gene, and FNAC combined with BRAFV600E gene detection were 0.818, 0.924, and 0.955, respectively. Conclusion FNAC combine with BRAFV600E gene detection improves the accuracy of neck lymph node metastasis in patients with thyroid cancer, which is worthyof performed.
To search for the relationship between immune state and tumor metastases, CD3,CD4,CD8 and CD44 contents in 13 speciments of fine needle aspiration (FNA) from thyroid cancer patients were detected by the flowcytometry (FCM) and comparison between thyroid cancer and benign tumor was made. The result showed :in thyroid cancer group, CD+3,CD+4 cells and the ratio of CD+4/CD+8 reduced significantly (P<0.01),and CD+8 cell increased significantly (P<0.01), in metastases group,this change was much significantly. CD44 expressed significantly higher in cancer group than that of the benign thyroid neoplasms, and the change was related to the tumor metastases. The results indicate that CD44 can be as a marker of tumor and indicator of metastases. The disturbance of immune system results in active expression of CD44 by tumor cells, so, lead to metastases. It is helpful to the diagnosis of thyroid cancer, assessment of metastases and management in surgery.
ObjectiveTo compare the diagnostic accuracy, sampling satisfaction, and safety of ultrasound-guided core needle biopsy (CNB) and fine needle aspiration biopsy (FNA) for thyroid nodules.MethodsThe databases of PubMed, Medline, Web of Science, Cochrane Library, Wanfang, CNKI, and CBM were searched to collect the relevant studies on the diagnostic performance, sampling satisfaction, and safety of ultrasound-guided CNB and FNA for thyroid nodules. Revman 5.3 and Stata 15 software were used for meta-analysis.ResultsA total of 24 studies involving 25 388 patients were included. Meta analysis showed that: compared with CNB, FNA had poor diagnostic accuracy [OR=0.26, 95%CI (0.15, 0.46), P<0.000 01], poor sampling satisfaction [OR=0.20, 95%CI (0.12, 0.33), P<0.000 01], lower incidence of total complications [OR=0.28, 95%CI (0.16, 0.50), P<0.000 1], and lower incidence of bleeding after biopsy [OR=0.62, 95%CI (0.48, 0.81), P=0.000 3]. However, there was no significant difference in the pain score [WMD=–0.21, 95%CI (–0.57, 0.15), P=0.26] between the two groups. Subgroup analysis showed that there was no significant difference in the accuracy of biopsy diagnosis of thyroid nodules with diameter less than 10 mm between the two groups [OR=0.52, 95%CI (0.15, 1.81), P=0.30], however, the accuracy of CNB in the diagnosis of thyroid nodules with diameter ≥ 10 mm was still better than FNA [OR=0.26, 95%CI (0.12, 0.56), P=0.000 5].ConclusionsCompared with FNA, ultrasound-guided CNB has a certain advantages in sampling satisfaction and the diagnosis accuracy of thyroid nodules with diameter ≥ 10 mm. CNB is better than FNA, but will bring higher risk of complication.
Objective To summarize the basic principle of electrical impedance spectrum technology and the latest progress in the diagnosis of thyroid carcinoma. Methods By the domestic and overseas literatures review, medical application and diagnostic prospect in thyroid carcinoma of electrical impedance spectrum were summarized. Results Electrical impedance spectrum was a kind of somatic function imaging, whose measurement results was objective, and it could diagnose thyroid carcinoma in early stage effectively. In addition, it could be used as a complementary form of fine needle aspiration biopsy, improving the diagnostic accuracy rate of thyroid carcinoma, thereby reducing the unessential thyroid operations. Conclusion Electrical impedance spectrum technology is a potentially useful imaging modality for diagnosing thyroid carcinoma in early stage, and functions as a auxiliary clinical diagnosis method for fine needle aspiration biopsy.