find Keyword "经导管主动脉瓣置换术" 130 results
  • Expert recommendations for standardized perioperative management after transapical transcatheter aortic valve implantation

    The technique of transcatheter aortic valve implantation has become increasingly mature. Although the transapical approach has a certain degree of minimally invasive trauma, it still has the characteristics such as heart beating without cardiopulmonary bypass, and the low technical requirements of catheter guide wire. In particular, the valve path is short and coaxial, which is easy to manipulate, and pure regurgitation and stenosis can be easily operated and are not subject to the limit of peripheral artery stenosis. It is still one of China's main approaches for transcatheter aortic valve replacement. Its perioperative management still has specific features and differs from the femoral artery approach. In addition, there is little relevant literature abroad. Therefore, domestic experts in this field were organized to discuss the development of perioperative management specifications to provide reference and techniques support for developing this field in China and further improve the quality of clinical operation and perioperative management. It will provide more safe and more effective medical services to these patients.

    Release date:2023-07-10 04:06 Export PDF Favorites Scan
  • Outcomes and preoperative evaluation of transfemoral transcatheter aortic valve replacement (TAVR) in the treatment of pure native aortic valve regurgitation

    ObjectiveTo assess outcomes of transcatheter aortic valve replacement (TAVR) for pure native aortic valve regurgitation.MethodsA total of 129 patients underwent transfemoral TAVR in Fuwai Hospital from May 2019 to October 2020 were retrospectively analyzed. There were 83 males and 46 females with an average age of 72.26±8.97 years. The patients were divided into a pure native aortic valve regurgitation group (17 patients) and an aortic valve stenosis group (112 patients).ResultsThe incidence of valve in valve was higher in the pure native aortic valve regurgitation group (47.0% vs. 16.1%, P<0.01). There was no statistical difference between the two groups in conversion to surgery, intraoperative use of extracorporeal circulation, intraoperative left ventricular rupture, postoperative use of extracorporeal membrane oxygenation (ECMO), peripheral vascular complications, disabled stroke, death, or pacemaker implantation. There was no statistical difference in the diameter of annulus (25.75±2.21 mm vs. 24.70±2.90 mm, P=0.068) or diameter of outflow tract (25.82±3.75 mm vs. 25.37±3.92 mm, P=0.514) between the pure native aortic valve regurgitation group and the aortic valve stenosis group.ConclusionTransfemoral TAVR is a feasible method for patients with pure native aortic valve regurgitation. The diameter of annulus plane, the diameter of outflow tract and the shape of outflow tract should be evaluated.

    Release date:2021-09-18 02:21 Export PDF Favorites Scan
  • An interpretation of the 2-year follow-up results of Evolut Low Risk research

    Transcatheter aortic valve replacement (TAVR) has become a well-established treatment for patients with severe aortic stenosis. At present, TAVR has already shown noninferiority and even superiority to surgical aortic valve replacement (SAVR) in patients deemed at high or intermediate risk for SAVR. However, the long-term follow-up results of the randomized controlled trials comparing the efficacy and safety between TAVR and SAVR are still lacking in those patients who are at low risk for SAVR. This paper gives an overview and reviews results of the Evolut Low Risk trial and interprets its implications for transcatheter therapy in aortic valve diseases.

    Release date:2021-07-28 10:22 Export PDF Favorites Scan
  • Research status of commissural alignment between biological valve and autologous valve in transcatheter aortic valve replacement

    Commissural misalignment of biological valve and autologous valve during transcatheter aortic valve replacement may affect the filling of coronary artery, reduce the feasibility of redo-aortic valve intervention and damage the valve function, which will adversely affect long-term prognosis of patients. Some studies have obtained achievement by changing the axial direction of valve and using individualized computer simulation technology to improve the alignment technology. However, there are still many unknown problems about the impact of commissural misalignment on patients, and accurate commissural alignment techniques still need to be further explored. This article systematically expounds the possible impact of commissural misalignment between biological valve and autologous valve in transcatheter aortic valve replacement, possibly effective accurate commissural alignment techniques and related research progress.

    Release date:2022-05-24 03:47 Export PDF Favorites Scan
  • Research progress of transcatheter aortic valve replacement-related new valve prostheses

    Transcatheter aortic valve replacement has revolutionized the management of aortic stenosis and become the gold standard for the treatment of symptomatic and severe aortic valve stenosis in elderly patients. With the improvement in design and materials, newer generation transcatheter aortic valve prostheses had overcome the limitations of early-generation devices that were susceptible to paravalvular leak, atrioventricular block and vascular complications, to a certain extent. This review provides an update on the latest advances in transcatheter aortic valve prostheses.

    Release date:2023-09-28 02:17 Export PDF Favorites Scan
  • Advantages and related developments of self-expandable valves for transcatheter aortic valve replacement

    Transcatheter aortic valve replacement is an effective treatment for aortic stenosis currently, especially in elderly, surgical high-risk, and surgical procedures-intolerant patients with severe aortic stenosis. After several generations of updates in design and function, the self-expandable valves have shown significant efficacy in treating aortic stenosis patients with bicuspid aortic valve, bioprosthetic valve failure or small annulus, and superiority in terms of valve durability, and the favorable hemodynamic outcomes could translate into clinical endpoint benefit. This literature review summarizes the advantages and recent advances of the self-expandable valves in transcatheter aortic valve replacement.

    Release date:2023-12-25 11:45 Export PDF Favorites Scan
  • Transcatheter aortic valve replacement for quadricuspid aortic valve: a case report

    Quadricuspid aortic valve (QAV) is a rare congenital heart disease, and its long-term lesion type is mainly reflux. The application of transcatheter aortic valve replacement (TAVR) in such patients is extremely rare. This article reports a case of an elderly patient with QAV complicated with severe regurgitation and small subvalvular membrane. Through preoperative evaluation and guidance from the cardiac team discussion, a relatively high oversize rate retrievable valve was selected and the TAVR surgery was successfully completed. At the same time, the valve implantation depth was adjusted to cover the subvalvular membrane. After surgery, the patient’s symptoms such as palpitations were significantly improved. No obvious perivalvular leakage or regurgitation was observed. It provides a reference for TAVR surgical plans for such patients.

    Release date:2024-10-25 01:48 Export PDF Favorites Scan
  • A case report of transcatheter aortic valve replacement with descending aorta severe distortion

    An 89 years old male patient was admitted to the First Medical Center of Chinese PLA General Hospital due to chest tightness and shortness of breath for half a month. Severe aortic valve stenosis was found in post admission assessment. We proposed to perform transcatheter aortic valve replacement surgery. Preoperative evaluation showed severe distortion of the descending aorta. We used the double guide wire technique and a 14F long sheath to assist the stepwise balloon expansion, and successfully completed the valve implantation. For patients with severe tortuous aorta, how to successfully complete transcatheter aortic valve replacement, this case may provide some reference.

    Release date:2020-05-26 02:34 Export PDF Favorites Scan
  • Research progress of application of transcatheter aortic valve replacement in the bicuspid aortic valve stenosis

    Patients with bicuspid aortic valve (BAV) are characterized by asymmetric anatomy, severe calcification and combined aortic dilatation. Compared with tricuspid aortic valve stenosis patients, patients with BAV stenosis confront with greater surgical risks in transcatheter aortic valve replacement (TAVR), including paravalvular leak, aortic valve rupture, coronary artery obstruction, atrioventricular block and so on. However, with the advent of new generation of prosthetic valves and optimization of surgical strategies, several studies have shown that TAVR is safe and effective in the treatment of BAV stenosis. Therefore, we aim to provide an overview of the use of TAVR in patients with BAV stenosis.

    Release date:2023-07-25 03:57 Export PDF Favorites Scan
  • A case report of transcatheter aortic valve replacement for horizontal heart with aortic stenosis

    A 78-year-old female patient was admitted to West China Hospital of Sichuan University because of “amaurosis and polypnea for 4+ years”. The examination results before admission showed that severe stenosis of aortic valve, bicuspid aortic valve malformation, severe horizontal heart with 61.54° aortic angle. The preoperative evaluation of the patient indicated that the Society of Thoracic Surgeons score was 17.9%, which was high risk for surgery. After discussion by the heart team, the aortic stenosis was finally relieved by transcatheter aortic valve replacement. The operation was successfully completed by using the method of pulling and releasing the device with the same side basket. One month follow-up showed that the patient’s condition was stable and no complications occurred. This case aims to provide a reference for the treatment of horizontal heart with aortic stenosis. In the future, it is hoped that through continuous clinical practice, such patients will be provided with a safer and more efficient treatment plan.

    Release date:2020-05-26 02:34 Export PDF Favorites Scan