Objective To assess early clinical safety and efficacy of transfemoral transcatheter aortic valve replacement (TF-TAVR) for pure aortic regurgitation (PAR). Methods The clinical data of PAR patients who underwent TAVR in Wuhan Asia Heart Hospital and Wuhan Asia General Hospital from January 2018 to October 2022 were retrospectively analyzed. Patients were divided into a TF-TAVR group and a transapical transcatheter aortic valve replacement (TA-TAVR) group. The clinical data of the patients were analyzed. Results A total of 54 patients were enrolled, including 34 males and 20 females with an average age of 74.43±6.87 years. The preoperative N-terminal pro-B-type natriuretic peptide level was lower [808.50 (143.50, 2 937.00) pg/mL vs. 2 245.00 (486.30, 7 177.50) pg/mL, P=0.015], and the left ventricular end-diastolic diameter (56.00±6.92 mm vs. 63.07±10.23 mm, P=0.005) and sinus junction diameter (32.47±4.41 mm vs. 37.65±8.08 mm, P=0.007) were smaller in the TF-TAVR group. There was no death in the two groups during the hospitalization. Only 1 new death within postoperative 1 month in the TF-TAVR group (cerebral hemorrhage). A total of 2 new deaths in the TF-TAVR group (1 patient of sudden cardiac death and 1 of multiple organ failure), and there was no death in the TA-TAVR group within postoperative 3 months. There was 1 new death in the TA-TAVR group (details unknown), and there was no death in the TF-TAVR group within postoperative 6 months. There was no statistical difference between the two groups in the all-cause mortality and the cumulative survival rate during the follow-up period (P>0.05). The incidence of high atrioventricular block was 36.0% in the TF-TAVR group and 10.3% in the TA-TAVR group (P=0.024). There were no significant differences between the two groups in the perivalvular leakage (≥moderate), valve in valve, a second valve implantation, valve migration, cerebrovascular events, major vascular complications, complete left bundle branch block, new permanent pacemaker implantation or transferring to surgery (P>0.05). However, the incidence rates of complete left bundle branch block and new permanent pacemaker implantation were higher in the TF-TAVR group, accounting for 56.0% and 40.0%, respectively. Conclusion TF-TAVR is a safe and feasible treatment for PAR patients, which is comparable to TA-TAVR in the early postoperative safety and efficacy.
ObjectiveTo evaluate the safety and efficacy of transapical mitral valve repair with moderate-to-severe or severe mitral regurgitation (MR) by using LifeClip system. Methods We retrospectively analyzed the clinical data of 7 symptomatic patients with moderate-to-severe or severe MR who received transapical mitral valve repair by using the LifeClip system in our hospital from July to November 2021. There were 5 males and 2 females with an average age of 76.0±7.5 years. ResultsThere were 2 patients with degenerative MR and 5 patients with functional MR. All of the procedures were successful and 6 patients received 1 LifeClip while the other one patient received 2. The operation time was 135.7±46.9 min, the mechanical ventilation time was 12 (3, 14) h, and the hospital stay time was 18.1±4.1 d. No serious complications or death occurred during the perioperative or follow-up period. MR reduction by ≥2 grades was achieved in all the patients at the one-month follow-up. The classification of cardiac function was improved in varying degrees. Conclusion Transapical mitral valve repair using the LifeClip system shows good safety and efficacy for severe MR patients, and MR degree is significantly improved at early follow-up. However, the benefit of LifeClip should be validated in a larger sample size of Chinese population and through long-term follow-up.
Objective To compare the differences of transcatheter edge-to-edge repair (TEER) between trans-apical and trans-femoral groups in the treatment of mitral regurgitation. Methods A retrospective study was conducted on the patients who underwent TEER surgery at Tianjin Chest Hospital from February 2023 to October 2024. Patients were divided into two groups based on the surgical approach: trans-apical approach group and trans-femoral approach group. Baseline conditions, perioperative and postoperative 6-month survival status, and echocardiographic follow-up indicators were collected and compared between the groups. The primary endpoint indicators were all-cause mortality and device success rate. Secondary endpoint indicators included catheterization duration, heart failure readmission rate, and incidence of moderate or greater mitral regurgitation. Results A total of 33 patients were included, with 16 in the trans-femoral approach group and 17 in the trans-apical approach group. The average age was (69.85±7.86) years, and 17 patients (51.5%) were male. There were no statistically significant differences between the two groups in demographic characteristics, STS scores, comorbidities (except for diabetes), and laboratory tests. The proportion of patients with preoperative heart function≥grade Ⅲ was higher in the trans-apical approach group (88.2% vs. 43.8%, P=0.007), and the left ventricular end-diastolic diameter was smaller [(58.41±7.13)mm vs. (65.81±11.58) mm, P=0.033]. The catheterization operation time was shorter in the trans-apical approach group [40.00 (30.00, 61.00) min vs. 74.00 (56.25, 108.25) min, P=0.002]. There were no statistically significant differences between the two groups in all-cause mortality, device success rate, and heart failure readmission rate. Conclusion TEER surgeries via different approaches might have the same safety and efficacy. The trans-apical TEER surgery is simpler to operate, has a shorter learning curve, and is easier for beginners to master.
ObjectiveTo investigate the reliability and safety of the technique of percutaneous left ventricular transapical access guided by cardiac three dimensional CT angiography (3D-CTA) combined with echocardiography applied in structural heart defects.MethodsThe clinical data of 9 patients (7 males and 2 females with a median age of 50 years ranging from 43 to 64 years) with paravalvular leaks closed by percutaneous left ventricular transapical access in West China Hospital, from April 2015 to August 2018, were retrospectively analyzed. We applied preoperative cardiac 3D-CTA to define the puncture site and trace, which was established by combining with real-time guidance of transesophageal echocardiography (TEE/3D-TEE), and an occluder was deployed at the apical access point for hemostasis with real-time guidance of transthoracic echocardiography (TTE).ResultsThe puncture needles were successfully introduced into the left ventricular cavity at one time in all patients without injury of lung tissue, coronary artery or papillary muscle. There was no occluder displacement or apex bleeding. One patient developed pleural effusion caused by intercostal artery injury.ConclusionThat cardiac 3D-CTA is used to define puncture sites and trace with advantages of simplicity and repeatability. A safe access and secure exit of left ventricle can be achieved by combining with real-time guidance of echocardiography. There are acceptable technology-related complications.
ObjectiveTo determine the clinical efficacy of transapical transcatheter mitral valve-in-valve treatment for patients with deteriorated mitral bioprosthesis after aortic-mitral double valve replacement.MethodsThe clinical data of 9 patients who underwent transapical transcatheter mitral valve-in-valve implantation after aortic-mitral double valve replacement due to mitral bioprosthesis deterioration from May 2020 to January 2021 in our hospital were retrospectively analyzed, including 4 males and 5 females with a mean age of 72.44±7.57 years.ResultsSurgeries were performed successfully in all patients with no conversion to median sternotomy. The mean procedural time was 101.33±48.49 min, the mechanical ventilation time was 23.11±26.54 h, the ICU stay was 1.89±1.05 d and the postoperative hospital stay was 6.11±2.02 d. Residual mild mitral regurgitation was only observed in 1 patient. Only 1 patient needed postoperative blood transfusion. No major complications were observed in all patients. There was no death in postoperative 90 days.ConclusionFor patients with deteriorated mitral bioprosthesis after aortic-mitral double valve replacement, transapical transcatheter mitral valve-in-valve implantation achieves good clinical results and effectively improves the hemodynamics without increasing the risk of postoperative left ventricular outflow tract obstruction. The surgery is feasible and effective.
Transcatheter aortic valve replacement (TAVR) has entered a new and critical stage after nearly 20 years of rapid development in China. There are various types of TAVR valves with different advantages. TAVR can be performed through various approaches such as transfemoral artery, transapical, trans-carotid artery, or trans-ascending aorta. The first two are more common. Echocardiography plays an important role in the perioperative period of TAVR. Compared to transfemoral approach, transapical TAVR has different key points in perioperative echocardiography which is lack of unified and accurate standards. This standard is specially formulated to focus on the key points of echocardiography in preoperative screening, intraoperative monitoring and postoperative follow-up in order to promote the safe and effective application of transapical TAVR in the clinic.
ObjectiveTo assess the early outcome of transapical transcatheter aortic valve replacement (TAVR) for patients with aortic insufficiency. MethodsThe patients with aortic valvular disease who underwent transapical TAVR from October 2020 to October 2022 in the Department of Cardiac and Vascular Surgery, the First Affiliated Hospital of Anhui Medical University were enrolled in the current retrospective study. The patients with aortic stenosis were assembled in a group A, and the patients with aortic insufficiency were assembled in a group B. The improvements of heart function and complications were assessed for the two groups. ResultsA total of 56 patients were enrolled, including 32 males and 24 females with an average age of 73.34±5.10 years. There were 31 patients in the group A and 25 patients in the group B. There was no statistical difference between the two groups in the age, gender, height, weight, hypertension, coronary artery disease, peripheral vascular disease, chronic obstructive pulmonary disease, renal disorder or classification of heart function (P>0.05). Also, there was still no statistical difference in the rate of permanent peacemaker implants, emergent open surgery, valve re-implants, or perivalvular leakage (P>0.05). After TAVR, the left ventricular diastolic diameter, left ventricular ejection fraction, complicated moderated mitral and tricuspid regurgitation were significantly improved in both groups compared with preoperative findings (P<0.05); however, there was no statistical difference in these parameters between groups (P>0.05). ConclusionInterventional valve (J-Valve) in the treatment of patients with aortic insufficiency through transapical TAVR significantly improves cardiac function and reduces functional valve regurgitation.