Objective To evaluate the effectiveness of the AO anatomical locking compression plate in treating type C distal humeral fracture. Methods Between July 2008 and April 2009, 13 cases of type C distal humeral fracture were treated with the AO anatomical locking compression plates. There were 5 males and 8 females with an average age of 52.1 years (range, 24-80 years). Fractures were caused by tumbl ing in 7 cases, by traffic accident in 4 cases, and by fall ing from height in2 cases. According to Association for Osteosynthesis/Orthopaedic Trauma Association (AO/OTA) classification, there were 3 cases of type C1, 6 cases of type C2, and 4 cases of type C3. Two cases compl icated by ulnar nerve injuries, 1 by radial nerve injury, 2 by fractures of ulnar olecranon, 3 by fractures of other parts of extremities, and 6 by osteoporosis. The time from injury to hospital ization ranged from 3 hours to 4 days (0.9 day on average). Results All the incisions achieved heal ing by first intention. Thirteen cases were followed up 12 to 21 months with an average of 15.9 months. According to the X-ray films, unions were achieved both at fracture site and the olecranon osteotomy site with a heal ing time of 8 to 13 weeks (10 weeks on average). The function of elbows recovered from 3 to 32 weeks (10 weeks on average). No fixation failure, myositis ossifican, delayed union, or malunion occurred during the follow-up. The Mayo Elbow Performance score ranged from 75 to 100 with an average score of 95.8; the results were excellent in 9 cases, good in 3 cases, and fair in 1 case with an excellent and good rate of 92.3%. Conclusion The AO anatomical locking compression plate has a good fixation in treating type C distal humeral fracture. Through the approach of olecranon osteotomy, it is easy to get anatomical reduction, stable fixation, and early exercise.
ObjectiveTo analyze the effectiveness of external fixator combined with Kirschner wire (EF-KW) fixation in the treatment of oblique and comminuted distal humeral metaphyseal-diaphyseal junction (DHMDJ) fractures in children. Methods A clinical data of 22 children with DHMDJ fractures who met the selection criteria between April 2021 and December 2023 was retrospectively analyzed. All patients were treated with EF-KW fixation. There were 14 boys and 8 girls with an average age of 6.8 years (range, 1.5-12.0 years). The time from injury to operation was 14-38 hours (mean, 24.2 hours). There were 18 cases of comminuted fractures and 4 cases of oblique fractures; and 1 case of median nerve injury and 1 case of radial nerve injury before operation. The occurrence of postoperative complications was recorded. At last follow-up, the function of the affected elbow joint was evaluated according to the Mayo elbow joint function score, and the Baumann’s angle (BA) and humero-capitellar angle (HCA) of the affected and healthy sides were recorded and compared. ResultsAll fractures were successfully treated with closed reduction and no complications such as nerve injury occurred. Superficial infection occurred in 4 cases after operation and healed after symptomatic treatment. The incisions of other patients healed by first intention. All patients were followed up 9-24 months (mean, 13.8 months). At last follow-up, according to the Mayo elbow joint function score, the elbow joint function was rated as excellent in 15 cases, good in 6 cases, and fair in 1 case, with an excellent and good rate of 95.5%. The neurologic injury before operation recovered gradually. X-ray films reexamination showed that all fractures healed, and the healing time of fractures ranged from 29 to 61 days, with an average of 35.6 days. At last follow-up, there was no significant difference in BA and HCA between the healthy side and the affected side (P>0.05). During follow-up, 1 case developed mild cubitus varus, while the other patients had no serious complications. ConclusionEF-KW fixation for oblique and comminuted DHMDJ fractures in children has the advantages of less trauma, simple operation, easy reduction, good stability after reduction, low incidence of serious complications, and good elbow functional recovery.
Objective To summarize the research progress in the treatment of distal humeral metaphyseal-diaphyseal junction (DHMDJ) fractures in children and to provide reference for clinical practice. MethodsThe characteristics and treatment methods of transverse and comminuted DHMDJ fractures in children were summarized and analyzed by referring to relevant literature at home and abroad. Results DHMDJ fractures in children are not uncommon clinically, with high fracture line position, multi-directional instability, difficult closed reduction in treatment, and easy to cause complications such as coronal and sagittal deformity of the elbow. The Kirschner wire technique was effective for DHMDJ fractures with the fracture line at the middle and low levels, but was prone to iatrogenic ulnar nerve injury. Elastic stable intramedullary nail is suitable for higher-position transverse DHMDJ fractures. However, this technique requires a second operation to remove the internal fixator, and may cause iatrogenic epiphysis plate injury in children. External fixator is a new way to treat DHMDJ fractures, and it can show satisfactory results for transverse and comminuted DHMDJ fractures. However, at present, there are few relevant studies, and most of them focus on biomechanical studies, and the efficacy lacks high-quality clinical research support. Conclusion The ultimate goal of DHMDJ fracture treatment in children is to restore the anatomical alignment of the fracture and prevent the loss of reduction. The choice of internal fixator depends on the location of the fracture line and the shape of the fracture to provide personalized treatment.
Objective To compare the biomechanical properties of personalized Y-shaped plates with horizontal plates, vertical plates, and traditional Y-shaped plates in the treatment of distal humeral intra-articular fractures through finite element analysis, and to evaluate their potential for clinical application. Methods The study selected a 38-year-old male volunteer and obtained a three-dimensional model of the humerus by scanning his upper limbs using a 64-slice spiral CT. Four types of fracture-internal fixation models were constructed using Mimics 19.0, Geomagic Wrap 2017, Creo 6.0, and other software: horizontal plates, vertical plates, traditional Y-shaped plate, and personalized Y-shaped plate. The models were then meshed using Hypermesh 14.0 software, and material properties and boundary conditions were defined in Abaqus 6.14 software. AnyBody 7.3 software was used to simulate elbow flexion and extension movements, calculate muscle strength, joint forces, and load torques, and compare the peak stress and maximum displacement of the four fixation methods at different motion angles (10°, 30°, 50°, 70°, 90°, 110°, 130°, 150°) during elbow flexion and extension. Results Under dynamic loading during elbow flexion and extension, the personalized Y-shaped plate exhibits significant biomechanical advantages. During elbow flexion, the peak internal fixation stress of the personalized Y-shaped plate was (28.8±0.9) MPa, which was significantly lower than that of the horizontal plates, vertical plates, and traditional Y-shaped plate (P<0.05). During elbow extension, the peak internal fixation stress of the personalized Y-shaped plate was (18.1±1.6) MPa, which was lower than those of the other three models, with significant differences when compared with horizontal plates and vertical plates (P<0.05). Regarding the peak humeral stress, the personalized Y-shaped plate model showed mean values of (10.9±0.8) and (13.1±1.4) MPa during elbow flexion and extension, respectively, which were significantly lower than those of the other three models (P<0.05). Displacement analysis showed that the maximum displacement of the humerus with the personalized Y-shaped plate during elbow flexion was (2.03±0.08) mm, slightly higher than that of the horizontal plates, but significantly lower than that of the vertical plates, showing significant differences (P<0.05). During elbow extension, the maximum displacement of the humerus with the personalized Y-shaped plate was (1.93±0.13) mm, which was lower than that of the other three models, with significant differences when compared with vertical plates and traditional Y-shaped plates (P<0.05). Stress contour analysis showed that the stress of the personalized Y-shaped plate was primarily concentrated at the bifurcation of the Y-shaped structure. Displacement contour analysis showed that the personalized Y-shaped plate effectively controlled the displacement of the distal humerus during both flexion and extension, demonstrating excellent stability. ConclusionThe personalized Y-shaped plate demonstrates excellent biomechanical performance in the treatment of distal humeral intra-articular fractures, with lower stress and displacement, providing more stable fixation effects.
Objective To investigate the effect of functional exercises at different time and different immobilization positions on the functional recovery of elbow joint with type C distal humeral fractures. Methods A total of 120 patients with type C distal humeral fractures admitted to the hospital between June 2013 and July 2015 were included in the study. They were randomly allocated to 3 groups, 40 patients in each group. Group A: functional exercises began immediately after the operation; Group B: the affected elbow was fixed at 90° flexion for 1 week and then began functional exercises after 1 week of immobilization; Group C: the affected elbow was fixed at 30° extension for 1 week and then began functional exercises after 1 week of immobilization. There was no significant difference in gender, age, fracture pattern, fracture side, injury time, and surgical approach between groups (P>0.05). Results In groups A and B, 1 case had incision redness and swelling respectively, and the other incisions healed by first intention. Five patients occurred myositis ossificans in group A, 4 cases in group B, and 5 cases in group C. The incidence of complications in groups A, B, and C was 15.0% (6/40), 12.5% (5/40), and 12.5% (5/40), respectively. There was no significant difference between groups (χ2=0.144, P=0.930). All patients were followed up 6-25 months, with an average of 9.8 months. At 2 weeks after operation, the Mayo elbow joint function score of group A was significantly higher than those of groups B and C (P<0.05), and the visual analogue scale (VAS) of group A was significantly lower than those of groups B and C (P<0.05). There was no significant difference between groups B and C (P>0.05). At 6 months after operation, there was no significant difference in Mayo elbow joint function score and VAS score between groups (P>0.05). At 2 weeks and 6 months after operation, the flexion and extension activities of elbow joint in groups A and C were better than that in group B (P<0.05), and there was no significant difference between groups A and C (P>0.05). There was no significant difference in forearm rotation between groups (P>0.05). All fractures of 3 groups achieved clinical healing, and there was no significant difference in healing time between groups (P>0.05). Conclusion Early functional exercises can relieve pain and obtain better elbow flexion and extesion activities after operation. The elbow joint fixed at 30° extension is better than at 90° flexion in elbow flexion and extension activitis.
Objective To investigate the effect of microsurgical repair of refractory bone defects and nonunion in distal humers. Methods Twelve cases of bone defects and nonunion indistal humerus wererepaired with free vascularised fibular graft and fixed with the anatomical bone plate. Of the 12 cases, 8 had pseudarthrosis, and 4 had bone defects 3-5 cm. Fibular graft ranged from 5-15 cm, 8.5 cm in average. Results After a follow-up of 3-18 months, 8.5 months in average, all cases of free vascularised fibular graft healed within 38 months. The fibular graft thickenedas time passed. Normal recessive osseous elbow joint, improvement in the inflection and extension of elbow joint, and normal revolving of antebrachium were attained. The short of limbs were corrected. Satisfactory functions of supporting and fine operation were attained. Conclusion With the support of anatomical bone plate, the fibular graft can help the recovery of joint functionand repair bone defects and nonunion as to avoid joint replacement with prosthesis.
ObjectiveTo investigate the effectiveness of total elbow arthroplasty (TEA) with preservation of triceps brachii insertion approach.MethodsBetween January 2012 and September 2017, 17 patients with elbow disease were treated with TEA with preservation of triceps brachii insertion approach. There were 3 males and 14 females, with an average age of 65.2 years (range, 48-85 years). The injuries located on left elbow in 5 cases and on right elbow in 12 cases. There were 11 cases of distal humerus fracture (AO type C1 in 2 cases and type C3 in 9 cases); the interval between fracture and operation was 3-10 days (mean, 4.1 days). There were 3 cases of osteoarthritis and 3 cases of rheumatoid arthritis, with the disease duration of 2-26 years (mean, 8.7 years). The postoperative elbow function and pain was assessed by Mayo elbow performance score (MEPS) and visual analogue scale (VAS) score, respectively. The prosthesis position, heterotopic ossification, and periprosthetic fracture were observed by X-ray films.ResultsAll incisions healed by first intention. Sixteen patients were followed up 18-69 months (mean, 40.6 months). Intraoperative ulnar nerve injury occurred in 2 cases, and healed after symptomatic treatment. At last follow-up, the MEPS score was 55-100 (mean, 90.3). The results were excellent in 11 cases, good in 2 cases, fair in 2 cases, and poor in 1 case, with an excellent and good rate of 81.3%. The VAS score was 0-2 (mean, 0.4). X-ray reexamination showed that no polyethylene wear, prosthesis loosening and fracture, abnormal prosthesis position, periprosthetic fracture occurred during the follow-up period, and the prosthesis survival rate was 100%. Heterotopic ossification occurred in 2 and 3 months after operation in 2 cases, respectively.ConclusionThe triceps on approach for TEA are satisfactory for distal humerus fracture, osteoarthritis, and rheumatoid arthritis.
ObjectiveTo investigate the effectiveness of limited internal fixation combined with hinged super-articular external fixator to treat type C3 fracture of the distal humerus. MethodsBetween September 2007 and November 2012, 37 cases of type C3 fracture of the distal humerus were treated. There were 22 males and 15 females with an average age of 43.6 years (range, 22-66 years). The causes were accident injury in 24 cases, falling injury in 5 cases, falling from height in 4 cases, heavy crush injury in 2 cases, machine injury in 1 case, and other injury in 1 case. There were 22 cases of open injury and 15 cases of closed injury. The time from injury to operation was 3-46 hours (mean, 18 hours). ResultsNeedle tract reaction and incision infection occurred in 3 cases and 1 case respectively, healing of incision by first intension was obtained in the other cases. Thirty-six patients were followed up 9-48 months (mean, 25.4 months). Heterotopic ossification occurred in 3 cases after operation and no recurrence was found by release after fracture healing. Fractures healed in the other patients after 6-14 months (mean, 9 months) of operation except 1 patient who suffered chronic osteomyelitis. One patient had delayed ulnar neuritis at 12 months after operation, and the nerve function returned to normal after the ulnar nerve transposition. There was no bone ischemic necrosis, elbow joint instability, or loosening of internal fixation. At last follow-up, the average range of motion of injured elbow was 105.0° in flexion,-25.0° in extension, 69.2° in pronation, and 75.6° in supination. According to Mayo elbow joint function score (MEPS) and disability of arm shoulder and hand (DASH) score, the results were excellent in 22 cases, good in 8 cases, fair in 4 cases, and poor in 2 cases with an excellent and good rate of 83.3%; and according to Cassebaum elbow joint function score, the results were excellent in 21 cases, good in 7 cases, fair in 5 cases, and poor in 3 cases with an excellent and good rate of 77.8%. ConclusionA combination of limited internal fixation and hinged super-articular external fixator has satisfactory clinical curative effect for type C3 fractures of the distal humerus, relatively few complications.