The dysfunction of supination of forearm following injury of brachial plexus or poliomyelitis always affects the function of hand. To find the dynamic muscle for restoration of the supination, the flexor carpi radialis was investigated on fifty male cadavers. The blood supply of the muscle was polygenic, mainly derived from the humoral and radial arteries. The movement of the muscle was innervated by median nerve. If the proximal 1/3 belly of the muscle was reserved, the blood supply and innervation of the complete muscle was reserved. According to the anatomic data, the operative procedure was designed as following: transfer the distal 2/3 of flexor carpi radialis over the ulnar aspect of the forearm to the dorsal-radial side, the tendon was fixed on the radius shaft 6 to 10 cm proximal to the styloid process with forearm in full supination. Four patients were treated and after followed up for 3.2 years average, the supination restored. It was discussed that in case of paralysis of the flexor carpi ulnaris and pronator teres, the optimal choice to restore the supination would be flexor carpi radialis.
Objective To compare the long-term results of vascularised fibulargraft and simple autologous fibular graft for reconstruction of wrist after distal bone tumor resection.Methods From January 1979 to September2002, 15 patients with wrist defects due to distal bone tumor resection were treated with vascularised fibular graft or simple autologous fibular graft and followed up 1 year. The results were graded with Enneking’s system and evaluated radiographicallyaccording to the “International Symposium on Limb Salvage”. The grade system included limb function, radiological examination and the function of ankle. Results The limb function of 8 patients with vascularised fibular graft restored to 80% of normal function and the bone union was achieved within 6 months. The limbfunction of 6 patients with simple autologous fibular graft restored to 67% of normal function. The bony union was achieved within 6 months in 4 cases with thebone graft less than 5 cm and in the 13th and 16th months in 2 cases with the bone graft more than 12 cm. Conclusion It is suitable to use the headof fibular boneas a substitute for the distal radius. The healing of vascularised fibular graft is very quick and haven’t the bone resorption. So in the procedure for reconstruction and limb salvage after bone tumor resection of distal radius, the free vascularised fibular graft with fibular head is an ideal substitute.
Objective To analyze the short-term effectiveness of repairing musculus extensor carpi radialis brevis (ECRB) and extensor digitorum communis (EDC) tendon using suture anchor after debridement of extensor tendon insertion for recalcitrant lateral epicondylitis. Methods Between March 2009 and May 2011, 10 patients (10 elbows) with recalcitrant lateral epicondylitis received repair of the ECRB and EDC tendon to the lateral epicondyle using a single suture anchor after debridement of extensor tendon insertion. There were 6 males and 4 females with an average age of 45.4 years (range, 36-57 years). The dominant elbow was involved in 8 patients and nondominant elbow in 2 patients; there were 4 manual workers and 6 ordinary workers. The disease duration ranged from 8 to 24 months (mean, 12.3 months). All patients had epicondylus lateralis humeri pain, local swelling and tenderness, and positive Mill sign. The average elbow range of motion (ROM) was 11.3°(range, 0-30°) in extension and was 132.5°(range, 120-145°) in flexion. Preoperative MRI showed external humeral epicondylitis in all patients. ResultsPrimary wound healing was obtained in all patients without complications of infection, leakage of joint fluid, and stiffness of elbow. Ten patients were followed up 4 to 23 months with an average of 12 months (more than 12 months in 7 cases). The time to return to work was (3.75 ± 0.95) months for manual workers and was (2.91 ± 0.20) months for ordinary workers, showing no significant difference (t=1.715, P=0.180). Compared with preoperation, the mean visual analogue scale (VAS) score significantly decreased (P lt; 0.05), and Mayo score and the grip strength of dominant and nondominant significantly increased (P lt; 0.05), but no significant difference was found when compared with non-surgical side at last follow-up (P gt; 0.05). At last follow-up, the average ROM was —1.5° (range, 0-—10°) in extension and was 150.5°(range, 140-160°) in flexion. ConclusionTo suture anchor for repairing the ECRB and EDC after debridement is a satisfactory procedure to treat recalcitrant lateral epicondylitis. It can effectively prevent loss of the forearm extensor strength, relieve the pain, recover the grip strength, and obtain good results.
Objective To explore the application of improved carpal shoot through view (ICSTV) method in the treatment of distal radius fractures with volar plate internal fixation. Methods The clinical data of 67 patients with distal radius fractures who met the selection criteria between January 2020 and January 2023 was retrospectively analyzed. There were 30 males and 37 females with an average age of 53.6 years (range, 18-75 years). According to the AO/Orthopaedic Trauma Association (AO/OTA) classification, there were 25 cases of type B and 42 cases of type C. The time from injury to operation ranged from 2 to 6 days, with an average of 3.8 days. During the operation, bilateral cortical drilling was performed, and the length of the implanted screw was 1-2 mm shorter than that measured by the depth ruler. Standard anteroposterior and lateral (AAL) fluoroscopy and ICSTV fluoroscopy were performed after volar anatomic locking plate fixation, respectively. If the dorsal cortex of the distal radius was detected to be penetrated, the short screw was replaced and ICSTV fluoroscopy was performed again until no screw was penetrated. The detection rate of dorsal cortical screw penetration was compared between AAL fluoroscopy and ICSTV fluoroscopy. Postoperative CT scan was performed to confirm the presence or absence of dorsal cortical screw penetration. Results Intraoperative AAL fluoroscopy found 5 screws penetrating the dorsal cortex in 4 patients (6.0%), and ICSTV fluoroscopy found 19 screws penetrating the dorsal cortex in 15 patients (22.4%) including the above 4 patients, with a significant difference in the detection rate between the two fluoroscopy methods [OR=0.267 (0.084, 0.845), P=0.018]; 15 patients were replaced with short screws during operation. At the same time, ICSTV fluoroscopy detected 2 screws penetrating into the distal radioulnar joint in 2 cases (3.0%), which could not be found in AAL fluoroscopy, and the direction of the screws was adjusted and replaced. All patients were reexamined by wrist CT within 3 days after operation, and no dorsal cortical screw penetration or screw penetration into the distal radioulnar joint was found. All the 67 patients were followed up 6-18 months, with an average of 11.3 months. Extensor tendon irritation occurred in 2 patients at 3 months after operation, and no extensor tendon rupture occurred in all patients during follow-up. All fractures healed well, and the healing time was 8-13 weeks, with an average of 10.8 weeks. There was no complication such as internal fixation loosening or fracture displacement. The Gartland-Werley score at last follow-up ranged from 0 to 15, with an average of 5.6. ConclusionICSTV fluoroscopy can effectively detect occult dorsal cortical screw penetration of the distal radius that can not be revealed by AAL fluoroscopy.
【Abstract】 Objective To investigate the effect of the volar capsular l igament complex on stabil ity of the wrist jointand to provide basic biomechanical theoretical criteria for cl inic appl ication of the external fixator. Methods Nine upperl imbs specimens (left 6, right 3) were taken from fresh adult cadavers to make wrist joint-bone capsular l igament complex specimens. Firstly, soft tissues of forearms and hands were resected and capsular membranes and l igaments were reserved to make the bone-articular l igament complex (normal specimen). Secondly, the volar capsular l igament complex was cut off from radial malleolus to ulnar malleolus (impaired specimen). Thirdly, the impaired volar capsular l igament complex was interruptedly sutured by the use of 4# suture silk (repaired specimen). To simulate cl inical operation with external fixator, the biomechanical test was done according to the sequence (normal, impaired, repaired, repaired and fixed, impaired and fixed). Statistical significance was analyzed through selected loads at the three different shifts (1.5, 2.0, 2.5 cm). Results According to the sequence (normal, impaired, repaired, repaired and fixed, impaired and fixed), when the shift was 1.5 cm, the different respective loads were (60.74 ± 20.60), (35.23 ± 13.88), (44.36 ± 20.78), (168.40 ± 29.21) and (139.00 ± 33.18) N, respectively. When the shift was 2.0 cm, the different loads were (138.46 ± 12.93), (87.17 ± 24.22), (97.52 ± 23.29), (289.00 ± 54.29) and (257.98 ± 55.74) N, respectively. When the shift was 2.5 cm, the different loads were (312.87 ± 37.15), (198.16 ± 37.14), (225.66 ± 30.96), (543.15 ± 74.33) and (450.35 ± 29.38) N, respectively. There was no statistically significant difference between the impaired and repaired specimens (P gt; 0.05). Similarly, there was statistically significant difference among the rest specimens (P lt; 0.05). The same statistical results were obtained when the two different shifts were compared. There was statistically significant difference at the three different shifts for the same specimen (P lt; 0.05). Conclusion Volar capsular l igament complex is an important anatomic structure to keep stabil ity of the wrist joint. The carpal instabil ity arises out of the injured complex. Repairing the injured complex only can not immediately restore stabil ity of the wrist joint. The external fixator can effectively help to diminish the relative shift of the impaired capsular l igament complex, to reduce the load of the repaired complex and to protect the complex accordingly. The device plays an important role in maintaining stabil ity of the wrist joint.
Objective To provide anatomy evidence of the simple injury of the deep branch of the unlar nerve for cl inical diagnosis and treatments. Methods Fifteen fresh samples of voluntary intact amputated forearms with no deformity were observed anatomically, which were mutilated from the distal end of forearm. The midpoint of the forth palm fingerweb wasdefined as dot A , the midpoint of the hook of the hamate bone as dot B, the ulnar margin of the flexor digitorum superficial is of the l ittle finger as OD, and the superficial branch of the unlar nerve and the forth common finger digital nerve as OE, dot O was the vertex of the triangle, dot C was intersection point of a vertical l ine passing dot B toward OE; dot F was the intersection point of CB’s extension l ine and OD. OCF formed a triangle. OCF and the deep branch of the unlar nerve were observed. From May 2000 to June 2007, 3 cases were treated which were all simple injury of the deep branch of the unlar nerve by glass, diagnosed through anatomical observations. The wounds were all located in the hypothenar muscles, and passed through the distal end of the hamate bone. Muscle power controlled by the unlar nerve got lower. The double ends was sewed up in 2 cases directly intra operation, and the superficial branch of radial nerve grafted freely in the other 1 case. Results The distance between dot B and dot O was (19.20 ± 1.30) mm. The length of BC was (7.80 ± 1.35) mm. The morpha of OCF was various, and the route of profundus nervi ulnaris was various in OCF. OCF contains opponens canales mainly. The muscle branch of the hypothenar muscles all send out in front of the opponens canales. The wounds of these 3 cases were all located at the distal end of the hook of the hamate bone, intrinsic muscles controlled by the unlar nerve except hypothenar muscles were restricted without sensory disorder or any other injuries. Three cases were followed up for 2 months to 4 years. Postoperation, the symptoms disappeared, holding power got well, patients’ fingers were nimble. According to the trial standard of the function of the upper l imb peripheral nerve establ ished by Chinese Medieal Surgery of the Hand Association, the synthetical evaluations were excellent.Conclusion Simple injuries of the deep branch of the unlar nerve are all located in OCF; it is not easy to be diagnosed at the early time because of the l ittle wounds, the function of the hypothenar muscles in existence and the normal sense .
Objective To discuss the relationship between recovery of anatomical integrity and functional outcome in elderly patients with distal radius fractures by comparing the effects of open reduction and closed reduction. Methods The cl inical data were retrospectively analyzed from 78 elderly patients with distal radius fractures treating with nonoperation andoperation from February 2005 to March 2009. Thirty-seven patients underwent closed reduction and spl intlet fixation or cast appl ication (non-operation group), and forty-one patients underwent open reduction and internal fixation (operation group). In non-operation group, there were 15 males and 22 females with an average age of 73 years (60-83 years). According to the AO classification system for fracture, there were 8 cases of type A2, 7 cases of type A3, 7 cases of type B1, 4 cases of type B2, 2 cases of type B3, 4 cases of type C1, 2 cases of type C2, and 3 cases of type C3. The time from injury to admission was between 30 minutes and 3 days with a mean time of 1 day. In operation group, there were 18 males and 23 females with an average age of 71 years (62-80 years). According to the AO classification system for fracture, there were 5 cases of type A2, 7 cases of type A3, 7 cases of type B1, 6 cases of type B2, 3 cases of type B3, 4 cases of type C1, 5 cases of type C2, and 4 cases of type C3. The time from injury to admission was between 30 minutes and 7 days with a mean time of 1 day. There were no significant differences (P gt; 0.05) in sex, age, disease course and fracture classification between two groups. Results All incisions obtained heal ing by first intention after operation in operation group. All patients were followed up for 9-36 months (20 months on average). Fracture heal ing was achieved within 8 to 15 weeks, with an average of 11 weeks. There were no significant differences (P gt; 0.05) in fracture heal ing time between non-operation group [(10.8 ± 2.0) weeks] and operation group [(11.7 ± 2.5) weeks]. At last follow-up, thepalmar tilt angle was (5.6 ± 2.0)° and (8.6 ± 3.0)°, the radial incl ination angle was (19.1 ± 4.9)° and (21.8 ± 2.0)°, and the radial length was (8.3 ± 1.3) mm and (10.4 ± 1.4) mm in non-operation group and operation group, respectively; showing significant differences (P lt; 0.05) between two groups. According to the Gartland-Werley score, the results were excellent in 9 cases, good in 21 cases, fair in 5 cases, and poor in 2 cases in non-operation group, the excellent and good rate was 81.1%; in operation group, the results were excellent in 13 cases, good in 25 cases, fair in 2 cases, and poor in 1 case, the excellent and good rate was 92.7%, showing no significant difference (P gt; 0.05) between two groups. There were no significant differences (P gt; 0.05) in flexion and extension activity of wrist, radioulnar partial activity, pronation-supination activity, grip and pinch strength between two groups. Conclusion Open reduction and closed reduction can achieve satisfactory functional outcomes, but closed reduction was inferior to open reduction in anatomic reduction for treating distal radius fractures in elderly patients.