Objective To review the biomechanics of internal fixators for proximal humeral fractures, and to compare the mechanical stabil ity of various internal fixators. Methods The l iterature concerning the biomechanics of internal fixators for proximal humeral fractures was extensively analyzed. Results The most important things for best shoulder functional results are optimal anatomical reduction and stable fixation. At present, there are a lot of methods to treat proximal humeral fractures. Locking-plate exhibites significant mechanical stabil ity and has many advantages over other internal fixators by biomechanical comparison. Conclusion Locking-plate has better fixation stabil ity than other internal fixators and is the first choice to treat proximal humeral fractures.
Objective To investigate the therapeutic effect of long PHILOS locking compression plate on the proximal humerus and humeral shaft fractures. Methods From March 2005 to December 2007, 35 cases with the proximal humerus and humeral shaft fractures were treated with long PHILOS locking compression plate, including 16 males and 19 females aged 29-68 years old (average 54.5 years old). There were 34 cases of fresh and close fracture, and the time from injury to operation was 3-9 days. One case had delayed union of fracture 5 months after receiving T-plates and internal fixation with steel plate. For the proximal humerus fracture, 7 cases had 2 parts of fracture, 19 had 3 parts of fracture, and 9 had 4 parts of fracture according to Neer classification; while for the humeral shaft fracture, 3 cases were classified as A1, 5 as A2, 10 as B1, 3 as B2, 6 as B3, 7 as C1 and 1 as C3 according to AO classification. Postoperatively, Neer scoring system was employed to evaluate the function of shoulder joint and HSS scoring system was adopted to evaluate the function of elbow joint. Results All incisions healed by first intension, and 30 cases were followed up for 12-33 months (average 18.2 months). Postoperatively, 2 cases had symptoms of radial nerve paralysis, which disappeared within 3 weeks; 1 case suffered from humeral head necrosis and received the secondary operation of humeral head replacement; humeral head was reduced evenly in 1 case, and 2 cases felt chronic sl ight pain in shoulder joints and received no further treatment. X-ray films showed 29 cases had fracture heal ing 6 months after operation, and all the patients had bone union 12 months after operation except 1 case receiving humeral head replacement. No such compl ications as screw lossening and internal fixation loosening occurred. By Neer scoring system, 6 cases were graded as excellent, 19 as good, 3 as fair, 2 as poor, and the excellent and good rate was 83.3%. By HSS scoring system, 16 cases were gradedas excellent, 14 as good, and the excellent and good rate was 100%. Conclusion Applying long PHILOS locking compression plate in the treatment of the proximal humerus and humeral shaft fractures provides a sol id fixation and high satisfactory rate with minor compl ications.
Objective To study the reparative and reconstructive for proximal humerus defect due to the excision of bone tumor with noninternal fixation non-vascularised fibular autografts. Methods From June 1991 toDecember 2003, 26 non-vascularised fibular grafts were used as substitutes for repair and reconstruction after resection for bone tumors on proximal humerus. Fifteen cases were given curettage and fibular supporting internal fixation, the other 11 cases were given tumor resection and joint reconstruction with proximal fibular graft. The age ranged from 6 to 41 years. Out of 26 patients, 5 had giant cell tumor, 9 had bone cysts, 8 had fibrous dysplasia and 4 had enchondroma. Results Twenty-six patients were followed up from 1 to 12 years (3.4 years on average). Local recurrence was found in 2 cases, and 1 of them died of lung metastasis. Both outlook and function of the reconstructed joints have good results in 15 proximal humeral joint surface reserved cases. Of them, 3 children gained normal shoulder function 3 weeks after operation. Part function were obtained in the other 11 fibular grafts substituted proximal humeral defect. Conclusion Non-vascularised fibular grafts is an appropriate treatment option for proximal humerus bone defect due to excision of bone tumor.
【Abstract】 Objective To evaluate the effectiveness of artifical humeral head replacement in treatment of complicatedfractures of the proximal humerus. Method Between January 2005 and January 2011, 18 patients with proximal humerusfracture were treated with artifical humeral head replacement. There were 8 males and 10 females with a mean age of 71 years (range, 52-84 years). Fractures were caused by falling in 11 cases, by traffic accident in 3 cases, and by bruise in 4 cases. The time between injury and admission was 2 hours to 3 days (mean, 1.5 days). According to Neer classification, 8 cases had three-part fracture, 7 four-part fracture, and 3 cleavage fracture of humeral head; 5 cases complicated by shoulder joint subluxation, 2 cases by femoral fracture, 1 case by radial fracture, and 11 cases by osteoporosis. All the patients were treated with modular cemented prostheses. Results The operation time was 60-180 minutes with an average of 80 minutes; the blood loss was 100-400 mL with an average of 200 mL. All incisions healed by first intention without infection or neurovascular injury. Sixteen patients were followed up 3 years on average (range, 1-6 years). No loosening, dislocation of prothesis or heterotopic ossification occurred. According to the Neer scores, the results were excellent in 5 cases, good in 8 cases, moderate in 2 cases, and poor in 1 case at 1 year after operation. The excellent and good rate was 81.2%. Conclusion Artificial humeral head replacement is a good therapy for patients with complicated fractures of the proximal humerus, especially for elderly patients.
ObjectiveTo investigate the effectiveness of limited open reduction via “door-shaft method” and internal fixation with locking plate for two- and three-part fractures of the proximal humerus.MethodsThe clinical data of 64 patients with proximal humeral fractures who were admitted between January 2013 and December 2016 and met the selection criteria were retrospectively analyzed. There were 23 males and 41 females, with an average age of 68.0 years (range, 50-89 years). The injuries were caused by falling in 57 cases, traffic accident in 5 cases, and falling from height in 2 cases. The interval between injury and operation was 1-7 days (mean, 2.1 days). According to Neer classification, there were 28 cases of two-part fractures and 36 cases of three-part fractures. According to the angulation direction of the proximal humeral neck shaft angle, there were 21 cases of adduction fractures and 43 cases of abduction fractures. The fractures were treated with limited open reduction via “door-shaft method” and proximal humerus internal locking systems for internal fixation. The operation time, intraoperative blood loss, number of fluoroscopy, hospital stay, and complications were recorded. The fracture healing was reviewed by X-ray film and the healing time was recorded. The shoulder joint function was evaluated by Neer score standard.ResultsThe operation time was 45-127 minutes, with an average of 82.3 minutes. The intraoperative blood loss was 30-125 mL, with an average of 62.7 mL. Intraoperative fluoroscopy was performed 30-69 times, with an average of 37.0 times. The hospital stay was 6-23 days, with an average of 10.3 days. All incisions healed by first intention. All patients were followed up 12-37 months, with an average of 18.3 months. X-ray film re-examination showed that all fractures healed, the healing time was 12-21 weeks, with an average of 14.3 weeks. After operation, 3 cases had shoulder stiffness and 1 case had fracture malunion. At last follow-up, the Neer score of shoulder joint function was 49-97, with an average of 83.1. Among them, 38 cases were excellent, 13 cases were good, 10 cases were fair, and 3 cases were poor. The excellent and good rate was 79.7%. The excellent and good rate of patients with two-part fractures was 82.1% (23/28), and the excellent and good rate of patients with three-part fractures was 77.8% (28/36).ConclusionThe “door-shaft method” not only reduces the difficulty of the Joystick technique in the reduction of proximal humerus fractures, but also provides auxiliary stability. It is used for limited open reduction and internal fixation with locking plate to treat the two- and three-part fractures of the proximal humerus, which can achieve good effectiveness.
ObjectiveTo compare the short-term effectiveness of femoral prosthesis with different neck-shaft angles for the reconstruction of proximal femoral anatomy after total hip arthroplasty (THA). MethodsBetween January 2012 and December 2013, 101 patients undergoing unilateral THA who accorded with selection criteria were selected for a retrospective study. The patients were divided into 2 groups:during THA, femoral prosthesis with 135° neck-shaft angle was used in 52 patients (group A) and femoral prosthesis with 127° neck-shaft angle was used in 49 patients (group B). There was no significant difference in gender, age, weight, body masss index, pathogeny, disease duration, preoperative neck-shaft angle, leg discrepancy, and preoperative Harris score between 2 groups (P>0.05). The postoperative Harris score was recorded to evaluate the effectiveness. And the femoral offset of the operated and contralateral sides, the change value of the femoral offset (xFO), the ratio of xFO to the offset of contralateral side (sdFO), the number of patients whose sdFO was more than 15% or less than -15% (outlier), the global offset, the height of femoral head rotation center, and leg discrepancy were measured at postoperation. ResultsOperative incision healed by first intension in 2 groups; no complication of infection, dislocation, or revision was found. All patients were followed up 12-32 months (mean, 23 months). The Harris score at last follow-up were significantly improved when compared with preoperative score in 2 groups (P<0.05), but there was no signficant difference between 2 groups (t=1.267, P=0.832). The xFO and sdFO of group B were significantly larger than those of group A (P<0.05); the number of outlier was 20 in group A and was 33 in group B, showing significant difference (P=0.005). The height of femoral head rotating center and global offset at 3 months after operation showed no signficant difference between 2 groups (P>0.05). And significant improvement in leg discrepancy was found at 3 months in 2 groups (P<0.05), but there was no significant difference between 2 groups (t=0.403, P=0.689). ConclusionBoth of the two femoral prosthesis with different neck-shaft angles can restore the proximal femoral anatomy well and gain similar early effectiveness after THA. However, the Stryker Trident femoral prosthesis with 127° neck-shaft angle may have the tendency to enlarge the femoral offset.
Objective To explore the feasibility and short-term effectiveness of the modified radical resection and reconstruction in the treatment of malignant proximal humerus tumor. Methods The relevant anatomic data from 30 normal adult shoulder joint MRI were measured to analyze the feasibility of modified radical resection and reconstruction surgery in the treatment of malignant proximal humerus tumor. Five patients with malignant proximal humerus tumor were treated by using the modified radical resection and reconstruction surgery between March 2012 and January 2016. There were 1 male and 4 females, aged from 9 to 69 years (median, 46 years). There were 4 cases of osteosarcoma (Enneking IIA in 2 cases and Enneking IIB in 2 cases) and 1 case of metastatic carcinoma (moderately differentiated adenocarcinoma). The disease duration was 7 to 12 months (mean, 9 months). Recurrence of tumor was observed after operation, and the shoulder function was assessed according to Enneking skeletal muscle tumor function scoring system. Results Radiographic results showed that modified radical resection and reconstruction surgery was feasible, which was in allowable range of the maximum longitudinal diameter ( < 29.8 mm) and depth ( < 4 mm). The operation was successfully completed in all 5 cases, and pathological examination suggested that purposes of radical resection had achieved. All patients were followed up 3 to 49 months (mean, 15.6 months). One patient had local recurrence at 12 months after operation, and a shoulder joint amputation was performed; the other 4 patients had good prosthesis survival. At last follow-up, the function of the shoulder joint was obviously recovered when compared with preoperative function; Enneking's skeletal muscle tumor function score was 25.8 points (range, 24 to 27 points). Conclusion Modified radical resection and reconstruction surgery is feasible for the treatment of proximal humerus tumor, and it can maintain a good early shoulder function.