目的:评估使用锁定钢板治疗桡骨远端不稳定骨折的疗效。方法:2005年8月至2009年5月使用锁定钢板治疗桡骨远端不稳定性骨折27例。平均553岁。按AO分类:B2型5例,B3型2例,C1型11例,C2型7例,C3型2例。结果:全部病例得到3~24个月随访,平均162个月。根据Fernandez评分标准进行腕关节功能评分:优14例,良10例,一般1例,差2例。优良率875%。 结论:掌侧锁定钢板治疗桡骨远端不稳定性骨折是安全有效的治疗选择,可提供坚强的固定,早期功能训练。
To investigate the effectiveness of T-locking plate in treating medial clavicle fracture so as to find out a therapy with safety and stabil ity. Methods Between October 2006 and January 2009, 13 patients with medial clavicle fracture were treated with open reduction and T-locking plate fixation. There were 9 males and 4 females, aged 18-68 years (mean, 47 years), including 7 cases of traffic accident injury, 4 cases of fall ing injury from height, and 2 cases of heavy object hit injury. The locations were left side in 5 cases and right side in 8 cases. All cases were closed fracture. The disease duration was 1 hour to 14 days. Results All incisions healed by first intention after operation. The X-ray films showed good reduction of fracture and internal fixation. All the 13 patients were followed up 12-18 months (mean, 15 months). The average fracture heal ing duration was 8 weeks (range, 6-12 weeks). No compl ication of infection, nerve or blood vessel injury, hemopneumothorax, or internal fixation loosening or failure occurred. The anatomical medial clavicle structure as well asappearances and functions were restored. According to Rockwood’s score method, the results were excellent in 11 cases and good in 2 cases. Conclusion The internal fixation of T-locking plate in treating medial clavicle fracture has the advantages of good stabil ity and low risk. Besides, the patients can do functional exercises early and the shoulder joint function can be improved in great degree.
Objective To evaluate the effectiveness of locking plates for Neer 3- and 4-part proximal humerus fractures. Methods A retrospective analysis was made on the clinical data of 77 patients with 3- or 4-part proximal humerus fractures, who underwent open reduction and internal fixation of locking plates and were followed up more than 12 months between July 2008 and May 2011. There were 39 males and 38 females with an average age of 54.2 years (range, 18-81 years). Fractures were caused by falling in 47 cases, by traffic accident in 16 cases, by falling from height in 4 cases, by sporting in 5 cases, and by other reasons in 5 cases. The time between injury and operation was 2-16 days (mean, 4.5 days). According to Neer classification, there were 54 cases of 3-part fracture and 23 cases of 4-part fracture. The Constant scores, visual analogue score (VAS), and the complications were evaluated during follow-up. Results After operation, healing of incisions by first intention was obtained in 76 cases and healing by second intention in 1 case. All patients were followed up 12-36 months (mean, 18.5 months). At last follow-up, the Constant score was 71.1 ± 11.9; the results were excellent in 18 cases, good in 24 cases, fair in 25 cases, and poor in 10 cases with an excellent and good rate of 54.5%. The VAS score was 2.8 ± 2.2. Bone nonunion occurred in 2 cases; the other patients had bone union within 2-6 months (mean, 3.2 months). The complications occurred in 25 cases (32.5%). Revision surgery was performed in 15 patients (19.5%). Conclusion The treatment of Neer 3- and 4-part proximal humerus fractures remains challenging. Anatomic reduction, stable fixation, and reduced humeral head blood supply disruption may lead to a satisfactory outcome.
Objective To evaluate the feasibility and short-term effectiveness of polyaxial locking plate for fixation of femoral neck fracture in the middle-aged and elderly patients. Methods A retrospective analysis was made on the clinical data of 13 patients with femoral neck fracture undergoing fixation with polyaxial locking plates between September 2013 and June 2015 (group A) and 13 patients with femoral neck fracture undergoing fixation with three cannulated screws in the same period (group B). There was no significant difference in gender, age, side, cause of injury, Garden type, type of fracture position, type of Pauwels angle, Singh index, time between injury and operation, and preoperative complications between 2 groups (P>0.05). The femoral neck shortening at 1 year postoperatively, and fracture nonunion, femoral head necrosis, and Harris hip score at last follow-up were compared between 2 groups. Results The follow-up time was (19.23±3.98) months in group A and (18.00±3.61) months in group B, showing no significant difference between 2 groups (t=2.063,P=0.417). No femoral head necrosis occurred in group A, but head necrosis occurred in 1 case of group B, and hemiarthroplasty was performed. There was no significant difference in the rate of femoral head necrosis between 2 groups (χ2=0.000,P=1.000). Bone union was obtained in the other patients of 2 groups. The Harris hip score of group A (85.23±2.95) was significantly higher than that of group B (81.92±3.64) at last follow-up (t=2.064,P=0.018). No infection or internal fixation failure occurred in 2 groups. One case had pain at the outer thigh at 1 month after operation in group A, but pain relief was achieved at 3 months after operation. At 1 year after operation, no femoral neck shortening occurred in group A, but degree I, II, and III femoral neck shortening was observed in 3, 2, and 8 cases of group B, respectively, showing significant difference between 2 groups (Z=–4.714,P=0.000). Conclusion Although fixation with polyaxial locking plate for femoral neck fracture in the middle-aged and elderly patients has similar femoral head necrosis rate to fixation with cannulated screws, it has advantages in preventing neck shortening and improving hip joint function after operation.
ObjectiveTo investigate the clinical results of locking-plate with an intramedullary fibular allograft for type C2 proximal humeral fracture fixation. MethodsBetween January 2011 and August 2012, 16 patients with proximal humeral fractures (AO type C2) were treated by locking-plate with an intramedullary fibular allograft. The clinical data were retrospectively analysed. There were 5 males and 11 females with an average age of 64 years (range, 55-70 years). The injury causes were falling injury in 12 cases, traffic accident injury in 3 cases, and sports injury in 1 case. The duration between injury and operation ranged from 2 to 6 days (mean, 4.5 days). The imaging data were used to judge the fracture healing, and to measure the neck-shaft angle and the height of humeral head; the disability of arm, shoulder, and hand (DASH) score, short-form 36 health survey scale (SF-36), and Neer score were used to evaluate the function of the shoulder after surgery. ResultsPrimary healing of incision was obtained in all patients; no complication of vascular and nerve injury occurred. Sixteen cases were followed up 12-24 months (mean, 18 months). All fractures healed at 18-24 weeks (mean, 20 weeks). No complication occurred as follows:re-displacement, necrosis, rejection reaction, and loosening or extraction of screws. At last follow-up, the neck-shaft angle was 126.6-136.9° (mean, 132.5°), showing a little lost when compared with intraoperative angle (130.5-138.0°, 134.0° on average). At 12 months after surgery, the height loss of humeral head was 1.8-4.6 mm (mean, 2.0 mm); the passive anteflexion of the shoulder was 130-160° (mean, 148°); the active anteflexion was 120-145° (mean, 136°); the external rotation was 30-65° (mean, 56°); the internal rotation was 15-25° (mean, 19°). And the DASH score was 2-53 (mean, 12); the SF-36 score was 50-95 (mean, 89). According to Neer score for shoulder function, the results were excellent in 10 cases, good in 4 cases, fair in 1 case, and poor in 1 case, with an excellent and good rate of 87.5%. ConclusionLocking-plate with an intramedullary fibular allograft for type C2 proximal humeral fracture fixation has satisfactory clinical results because of stable fixation, high clinical outcome scores, and low internal fixation failure.
ObjectiveTo explore the effectiveness of three different operative methods in the treatment of closed fracture of the tibial shaft. MethodsBetween January 2012 and May 2014, 94 patients with closed fracture of the tibial shaft were treated, and the clinical data were retrospectively analyzed. Fracture was fixed with locking plate (external fixation) in 25 cases (group A), with intramedullary nail in 34 cases (group B), and with minimally invasive locking plate in 35 cases (group C). There was no significant difference in gender, age, reasons of injury, fracture types, and time from injury to operation among groups (P>0.05). The operation time, intraoperative blood loss, fluoroscopy frequency during operation, fracture union time, and complications were recorded. The effectiveness was evaluated according to Johner-Wruhs criteria. ResultsThe operation time and fluoroscopy frequency during operation in groups A and C were significantly less than those in group B (P<0.05), but there was no significant difference between groups A and C (P>0.05). The intraoperative blood loss in groups A and C was significantly less than that in group B (P<0.05), and the blood loss in group A was significantly less than that in group C (P<0.05). All patients were followed up 15.61 months on average (range, 12-41 months). There was no significant difference in fracture union time among 3 groups (F=1.712, P=0.186). The excellent and good rates of groups A, B, and C were 92.00%, 88.24%, and 91.43% respectively according to Johner-Wruhs criteria at 12 months after operation, showing no significant difference (χ2=0.301, P=0.860). At 12 months after operation, the complication incidences of groups A (12.00%, 3/25), and C (15.55%, 5/35) were significantly lower than that of group B (44.12%, 15/34) (P<0.017), but no significant difference was found between groups A and C (P>0.017). ConclusionUsing locking plate as external fixation and minimally invasive locking plate internal fixation are better than intramedullary nail fixation in treating closed fracture of tibial shaft because of less injury and lower complication incidence, and locking plate as external fixation is better than minimally invasive locking plate internal fixation because of less injury.
ObjectiveTo compare the effectiveness of external fixation and volar locking compression plate in the treatment of distal radius fractures of type C. MethodsBetween March 2012 and March 2013, 122 patients with distal radius fractures of type C were enrolled in the prospective randomized study. Fractures were treated by external fixation in 61 patients (external fixation group) and by open reduction and internal fixation using a volar locking compression plate in 61 patients (plate group). There was no significant difference in age, gender, fracture side, weight, height, body mass index, fracture type, and interval of injury and operation between 2 groups (P>0.05). The blood loss, operation time, hospitalization days, fracture union time, wrist function, and complications were compared between 2 groups. And the quality of reduction was observed, including volar tilting angle, ulnar deviation, radial height, and articular reduction. ResultsThe blood loss, operation time, and hospitalization days in plate group were significantly higher than those in external fixation group (P<0.05). All of the patients in both groups were followed up 12-28 months. Postoperative complications occurred in 4 patients (6.6%) of external fixation group (pin tract infection in 2 cases and radial nerve neuritis in 2 cases) and in 5 patients (8.2%) of plate group (wound infection in 1 case, carpal tunnel syndrome in 2 cases, and tendon rupture in 2 cases), showing no significant difference between 2 groups (P=0.500). The X-ray films showed fracture healing in all patients of 2 groups; the union time of plate group was significantly longer than that of external fixation group (P<0.05). At last follow-up, there was no significant difference in ulnar deviation and radial height between 2 groups (P>0.05), but the volar tilting angle of plate group was significantly larger than that of external fixation group (P<0.05). There was no significant difference in wrist function and articular reduction between 2 groups (P>0.05). ConclusionFor distal radius fractures of type C, the use of external fixation or volar locking compression plate can obtain satisfactory clinical outcomes, but the external fixation has the advantages of less invasion, shorter hospitalization days, minor complications, and faster fracture union.
ObjectiveTo explore the therapeutic effect of using locking compression plate (LCP) as an external fixator and using an external fixator on open fractures of the tibia. MethodsBetween September 2010 and December 2012, 56 patients with the open tibia fractures underwent external fixation using LCP as an external fixator (LCP group, n=22) or external fixator (external fixator group, n=34). We compared the healing time, the rate of postoperative complication and the postoperative function between two groups. ResultsThe mean healing time was 11 weeks (8-28 weeks) and there was 1 case of delayed healing in the LCP group. The mean healing time was 14 weeks and there was 4 cases of delayed healing in the external fixator group. We found significant difference in the healing time (t=2.740, P=0.008) and the infection rate of pin track (13.6% vs 32.4%; χ2=2.496, P=0.114) between the LCP and external fixator group. ConclusionFor open fractures of the tibia, using LCP as an external fixator may increase the healing time and decrease the rate of postoperative complications.
ObjectiveTo observe the influence of different humeral neck-shaft angle on the efficacy in the treatment of proximal humeral fractures with locking plate. MethodsA total of 106 patients with proximal humeral fractures were treated by locking plate between March 2009 and March 2013, and the clinical data were retrospectively analyzed. Of 106 cases, 58 were male and 48 were female, aged from 26 to 71 years (mean, 52.3 years). The causes were traffic accident injury in 54 cases, falling injury from height in 23 cases, falling injury in 21 cases, and others in 8 cases. According to the Neer classification, there were 32 cases of two-part fractures, 65 cases of three-part fractures, and 9 cases of four-part fractures. The time from injury to operation was 1-7 days (mean, 2.7 days). According to neck-shaft angle by X-ray measurements at 1-3 days after operation, the patients were divided into 3 groups:valgus group (>145°), normal group (126-145°), and varus group (<126°) to observe the influence of neck-shaft angle on efficacy. ResultsAccording to postoperative humeral neck-shaft angle, there were 10 cases in valgus group, 75 cases in normal group, and 21 cases in varus group. There was no significant difference in general clinical data among 3 groups (P>0.05). The patients were followed up 6-12 months. The X-ray results showed fracture healing, and no significant difference was found in fracture healing time among 3 groups (P>0.05). After 6 months, the varus angle of femoral head and visual analogue scale (VAS) score of normal group were significantly lower than those of valgus group and varus group (P<0.05). The excellent and good rate of Constant-Murley score was 78.67% (59/75) in normal group, and it was significantly higher than that in valgus group (60.00%, 6/10) and varus group (42.86%, 9/21) (P<0.05), but there was no significant difference between valgus group and varus group (P>0.05). The complication rate was 28.57% (6/21) in varus group, was 10.67% (8/75) in normal group, and was 20.00% (2/10) in valgus group, showing no significant difference among 3 groups (χ2=4.31, P=0.12). ConclusionReconstruction of normal neck-shaft angle is the key to good shoulder function and clinical efficacy in the treatment of proximal humeral fracture.