ObjectiveTo explore the efficacy and advantages of the lower extremity axial distractor assisted closed reduction and retrograde intramedullary nail internal fixation in the treatment of distal femoral fractures.MethodsThe clinical data of 49 patients with distal femoral fractures treated with retrograde intramedullary nail internal fixation between April 2016 and December 2018 were retrospectively analyzed. According to the different methods of intraoperative reduction, the patients were divided into trial group (29 cases, using lower extremity axial distractor to assist closed reduction) and control group (20 cases, using free-hand retraction reduction). There was no significant difference in general information between the two groups (P>0.05), such as gender, age, side of injury, cause of injury, and fracture classification. The operation time, intraoperative blood loss, intraoperative fluoroscopy frequency, and callus formation time were recorded and compared between the two groups. The function of the affected limb was evaluated according to the Schatzker-Lambert standard at 1 year after operation.ResultsAll patients successfully completed the operation. In the control group, there was 1 case with open reduction and internal fixation, and the rest of the two groups were closed reduction. There was no significant difference in operation time, intraoperative blood loss, and intraoperative fluoroscopy frequency between the two groups (P>0.05). There was no complication such as vascular or nerve injury and iatrogenic fracture, etc. during and after operation, and the incisions healed by first intention. Except for 2 patients in the trial group who were lost to follow-up at 3 months after operation, the rest of the patients were followed up 12-36 months, with an average of 16.0 months. There was no significant difference in the callus formation time between the two groups (t=2.195, P=0.145). During the follow-up, postoperative knee joint stiffness occurred in 1 case in the control group, which improved by strengthening the knee joint function exercise and removing the internal fixator; the rest were not found to be associated with delayed or nonunion fractures, knee stiffness, and internal fixation complication. The function of the affected limb was evaluated according to the Schatzker-Lambert standard at 1 year after operation, the trial group achieved excellent results in 22 cases, good in 4 cases, and fair in 1 case, with an excellent and good rate of 96.3%; in the control group, the results were excellent in 16 cases, good in 3 cases, and fair in 1 case, with an excellent and good rate was 95.0%; showing no significant difference in the excellent and good rate between the two groups (χ2=0.451, P=0.502).ConclusionThe lower extremity axial distractor assisted closed reduction and retrograde intramedullary nailing for the treatment of distal femoral fractures is convenient, which has satisfactory efficacy.
ObjectiveTo explore the effectiveness of Taylor spatial frame (TSF) in the treatment of tibiofibular fractures and computer-assisted closed reduction.MethodsThe clinical data of 30 cases of tibiofibular fractures with soft tissue injury treated with TSF between January 2015 and September 2017 was retrospectively analyzed. According to different reduction methods, the patients were divided into control group (15 cases, open reduction in TSF external fixation) and trial group (15 cases, closed reduction in 1-3 days after TSF external fixation). There was no significant difference in the general data such as gender, age, affected side, cause of injury, AO classification of fracture, time from injury to operation between the two groups (P>0.05). The operation time, intraoperative blood loss, fracture healing time, and removal time of external fixator were recorded and compared between the two groups. At 3 months after removal of external fixator, the limb function was evaluated according to Johner-Wruhs criteria for evaluating the final effect of tibial shaft fracture treatment.ResultsBoth groups were followed up 9-16 months, with an average of 14 months. The operation time, intraoperative blood loss, fracture healing time, and removal time of external fixator in the trial group were significantly shorter than those in the control group (P<0.05). There were 2 cases of superficial infection of the external fixation (1 case in each group), 1 case of incision infection (control group), 1 case of delayed fracture healing (control group), 2 cases of traumatic arthritis (1 case in each group); no significant difference was found in the incidence of complications between the two groups (χ2=0.370, P=0.543). The wounds of soft tissue defect healed by the first intension in both groups. At 3 months after removal of the external fixator, the limb function results in the trial group were excellent in 3 cases, good in 9 cases, fair in 2 cases, and poor in 1 case, and the excellent and good rate was 80.0%; in the control group, the results were excellent in 3 cases, good in 8 cases, fair in 3 cases, and poor in 1 case, and the excellent and good rate was 73.3%. There was no significant difference in incidence of complication between the two groups (χ2=0.917, P=0.821).ConclusionCompared with intraoperative open reduction, postoperative computer-aided closed reduction can shorten the operation time, reduce the intraoperative blood loss, reduce the risk of long-term operation, avoid to destroy the blood supply of fracture end, shorten the healing time of fracture and the wearing time of stent, and alleviate the pain of patients after TSF treatment of tibiofibular fracture.
Objective To investigate the surgical technique and preliminary effectiveness of closed reduction and internal fixation (CRIF) using antegrade elastic intramedullary nailing (ESIN) via a novel approach through the proximal radius for treating distal radius metaphyseal-diaphyseal junction (DRMDJ) fractures in children. Methods A retrospective analysis was conducted on 34 children with DRMDJ fractures who met the selection criteria and were treated between January 2020 and June 2023. There were 21 boys and 13 girls, aged 6-14 years (mean, 8.2 years). Injury causes included falls in 11 cases and sports-related trauma in 23 cases. Twenty-six cases were associated with ipsilateral distal ulnar fractures. All patients had failed initial closed reduction in the outpatient clinic. The time from injury to operation ranged from 1 to 15 days (mean, 4 days). All patients underwent CRIF using antegrade ESIN inserted via a novel approach at the proximal one-third of the radius. The operation time, intraoperative fluoroscopy frequency, fracture healing time, and complications were recorded. Fracture reduction was assessed immediately after operation on anteroposterior and lateral X-ray films for residual translation and angulation. Wrist function was evaluated using the modified Mayo wrist score. ResultsSurgery was successfully completed in all 34 children. CRIF with ESIN failed in 2 cases with associated ipsilateral distal ulnar fractures, requiring conversion to open reduction of the ulna. Operation time ranged from 15 to 56 minutes (mean, 21 minutes). Intraoperative fluoroscopy frequency ranged from 5 to 21 times (mean, 7 times). Immediate postoperative X-ray films showed residual translation of 0-15% on anteroposterior view and 0-10% on lateral view, and residual angulation of 0°-5° on both anteroposterior and lateral views. All children were followed up 6-18 months (mean, 12 months). There was no complication such as neurovascular injury, incision infection, or limitation of forearm rotation. Follow-up X-ray films showed no fracture displacement, implant loosening, delayed union, or nonunion. Fracture healing time ranged from 4 to 8 weeks (mean, 6 weeks). Implants were removed at 4-6 months postoperatively (mean, 5 months). At last follow-up, all fractures had achieved anatomic or near-anatomic healing. The modified Mayo wrist score ranged from 80 to 100 (mean, 94), with 27 excellent and 7 good results, yielding an excellent and good rate of 100%. Conclusion CRIF using antegrade ESIN via a novel approach through proximal radius is a safe and effective treatment for pediatric DRMDJ fractures, associated with few postoperative complications and excellent restoration of wrist function.
Objective To evaluate and compare the outcomes of simple closed reduction, selective fragment excision after closed reduction, and emergency fragment excision and reduction in the treatment of Pipkin type I fracture of femoral head associated with posterior dislocation of the hip. Methods Between January 2002 and January 2008, 24 patients with Pipkin type I fracture of the femoral head associated with posterior dislocation of the hip were treated with simple closed reduction (closed reduction group, n=8), with selective fragment excision after closed reduction (selective operation group, n=8), and with emergency fragment excision and reduction (emergency operation group, n=8). In the closed reduction group, there were 6 males and 2 females with an average age of 37.6 years (range, 19-56 years); injuries were caused by traffic accident in 6 cases, by fall ing from height in 1 case, and by crushing in 1 case with a mean disease duration of 3.1 hours (range, 1.0-7.5 hours); and the interval from injury to reduction was (4.00 ± 2.14) hours. In the selective operation group, there were 7 males and 1 female with an average age of 37.3 years (range, 21-59 years); injuries were caused by traffic accident in 7 cases and by fall ing from height in 1 case with a mean disease duration of 3.2 hours (range, 1.0-6.0 hours); and the interval from injury to reduction was (3.90 ± 1.47) hours. In the emergency operation group, there were 5 males and 3 females with an average age of 35.5 years (range, 20-58 years); injuries were caused by traffic accident in 5 cases, by fall ing from height in 1 case, and by crushing in 2 cases with a mean disease duration of 3.3 hours (range, 1.5-6.5 hours); and the interval from injury to open reduction was (5.10 ± 2.04) hours. There was no significant difference in the age, gender, disease duration, and interval from injury to reduction among 3 groups (P gt; 0.05). Results All wounds in selective operation group and emergency operation group healed primarily. All the patients were followed up 24 to 58 months (mean, 38.7 months). According to Thompson-Epstein system, the excellent and good rates were 50.0% (4/8) in the closed reduction group, 87.5% (7/8) in the selective operation group, and 87.5% (7/8) in the emergency operation group at 24 months after operation, showing significant difference among 3 groups (χ2=9.803, P=0.020). Heterotopic ossification was found in 1 case (12.5%) of the closed reduction group, in 4 cases (50.0%) of the selective operation group, and in 4 cases (50.0%) of the emergency operation group, and avascular necrosis of femoral head was found in 2 cases (25.0%) of the closed reduction group; there was no significant difference in compl ications among 3 groups (P gt; 0.05). Conclusion The treatment of Smith-Petersen approach and fragment excision by selective operation or emergency operation has similar outcome, which are better than the treatment of simple closed reduction.
ObjectiveTo investigate the effectiveness and advantages of skeletal tractor in closed reduction and proximal femoral nail antirotation (PFNA) internal fixation of intertrochanteric fracture compared with traction table.MethodsThe clinical data of 86 patients with intertrochanteric fractures, who were treated with closed reduction and PFNA internal fixation between October 2016 and March 2018 and met the selection criteria, was retrospectively analysed. Among them, 44 cases were treated with skeletal tractor (trial group) and 42 cases were treated with traction table (control group). There was no significant difference between the two groups in gender, age, cause of injury, fracture side, AO classification, and degree of osteoporosis (P>0.05). The preoperative position time, operation time, intraoperative fluoroscopy times, intraoperative blood loss, fracture healing time, intraoperative and postoperative complications, and postoperative Harris score were compared between the two groups.ResultsThe operation was successfully completed in both groups. Compared with the control group, the patients in the trial group had shorter preoperative position time and operation time, fewer intraoperative fluoroscopy times, and less intraoperative blood loss (P<0.05). The patients were followed up 12-21 months in trial group (mean, 14.2 months) and 12-22 months in control group (mean, 14.3 months). Venous thrombosis of lower extremity occurred in 8 patients (3 cases of trial group and 5 cases of control group) after operation. Internal fixation failure occurred in 5 patients (2 cases of trial group and 3 cases of control group) during 1 year after operation. All fractures healed except for those with internal fixation failure, the fracture healing time was (11.6±2.9) weeks in trial group and (12.4±3.6) weeks in control group; and there was no significant difference between the two groups (t=1.250, P=0.214). At 1 year after operation, Harris score of the trial group was 86.2±5.9 and that of the control group was 84.1±6.1. There was no significant difference between the two groups (t=1.768, P=0.080).ConclusionCompared with traction table, skeletal tractor in closed reduction and PFNA internal fixation of intertrochanteric fracture can significantly shorten the preoperative position time and operation time, reduce the intraoperative fluoroscopy times, improve the operation efficiency, and have similar effectiveness.
Objective To investigate the effectiveness of joystick technique assisted closed reduction and cannulated screw fixation in the treatment of femoral neck fracture. Methods Seventy-four patients with fresh femoral neck fractures who met the selection criteria between April 2017 and December 2018 were selected and divided into observation group (36 cases with closed reduction assisted by joystick technique) and control group (38 cases with closed manual reduction). There was no significant difference in gender, age, fracture side, cause of injury, Garden classification, Pauwels classification, time from injury to operation, and complications (except for hypertension) between the two groups (P>0.05). The operation time, intraoperative infusion volume, complications, and femoral neck shortening were recorded and compared between the two groups. Garden reduction index was used to evaluate the effect of fracture reduction, and score of fracture reduction (SFR) was designed and was used to evaluate the subtle reduction effect of joystick technique. ResultsThe operation was successfully completed in both groups. There was no significant difference in operation time and intraoperative infusion volume between the two groups (P>0.05). All patients were followed up 17-38 months, with an average of 27.7 months. Two patients in the observation group received joint replacement due to failure of internal fixation during the follow-up, and the other patients had fracture healing. Within 1 week after operation, the Garden reduxtion index of the observation group was better than the control group; the SFR score of the observation group was also higher than that of the control group; the proportion of femoral neck shortening within 1 week after operation and at 1 year after operation in the observation group were lower than those in the control group. The differences of the above indexes between the two groups were significant (P<0.05). ConclusionThe joystick technique can improve the effectiveness of closed reduction of femoral neck fractures and reduce the incidence of femoral neck shortening. The designed SFR score can directly and objectively evaluate the reduction effect of femoral neck fracture.
Objective To explore the effectiveness of reduction robot combined with navigation robot-assisted minimally invasive treatment for Tile type B pelvic fractures. Methods Between January 2022 and February 2023, 10 patients with Tile type B pelvic fractures were admitted. There were 6 males and 4 females with an average age of 45.5 years (range, 30-71 years). The fractures were caused by traffic accident in 5 cases, bruising by heavy object in 3 cases, and falling from height in 2 cases. The interval between injury and operation ranged from 4-13 days (mean, 6.8 days). There were 2 cases of Tile type B1 fractures, 1 case of Tile type B2 fracture, and 7 cases of Tile type B3 fractures. After closed reduction under assistance of reduction robot, the anterior ring was fixed with percutaneous screws with or without internal fixator, and the posterior ring was fixed with sacroiliac joint screws under assistance of navigation robot. The time of fracture reduction assisted by the reduction robot was recorded and the quality of fracture reduction was evaluated according to the Matta scoring criteria. The operation time, intraoperative fluoroscopy frequency and time, intraoperative bleeding volume, and incidence of complications were also recorded. During follow-up, the X-ray film of pelvis was taken to review the fracture healing, and the Majeed score was used to evaluate hip joint function. Results The time of fracture reduction was 42-62 minutes (mean, 52.3 minutes). The quality of fracture reduction according to the Matta scoring criteria was rated as excellent in 4 cases, good in 5 cases, and poor in 1 case, with excellent and good rate of 90%. The operation time was 180-235 minutes (mean, 215.5 minutes). Intraoperative fluoroscopy was performed 18-66 times (mean, 31.8 times). Intraoperative fluoroscopy time was 16-59 seconds (mean, 28.6 seconds). The intraoperative bleeding volume was 50-200 mL (range, 110.0 mL). No significant vascular or nerve injury occurred during operation. All patients were followed up 13-18 months (mean, 16 months). X-ray films showed that all fractures healed with the healing time of 11-14 weeks (mean, 12.3 weeks). One case of ectopic ossification occurred during follow-up. At last follow-up, the Majeed score was 70-92 (mean, 72.7), and the hip joint function was rated as excellent in 2 cases and good in 8 cases, with the excellent and good rate of 100%. Conclusion The reduction robot combined with navigation robot-assisted minimally invasive treatment for Tile type B pelvic fractures has the characteristics of intelligence, high safety, convenient operation, and minimally invasive treatment, which can achieve reliable effectiveness.