west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "韧带" 439 results
  • 碳素纤维修复关节韧带损伤的临床应用

    关节韧带的撕裂或断裂伤,常导致该部关节的不稳定,影响其活动功能。报道应用碳索纤维编织带能与人体组织相容,重量轻,生物学上不活泼及抗拉力强的特点,作关节韧带的修复重建12例,取得了较满意的疗效。讨论了手术的优点,提出了防止碳纤维折断的方法等。

    Release date:2016-09-01 11:38 Export PDF Favorites Scan
  • REPAIR OF MEDIAL COLLATERAL LIGAMENT DEFECT OF KNEE JOINT WITH TRANSPOSITION OF GREAT ADDUCTOR MUSCULAR TENDON PEDICLED VESSELS

    BJECTIVE: To study the effect of transposition of great adductor muscular tendon pedicled vessels in repairing the medial collateral ligament defect of knee joint. METHODS: From September 1991 to September 1999, on the basis study of applied anatomy, 30 patients with the medial collateral ligament defect were repaired with great adductor muscular tendon transposition pedicled vessels. Among them, there were 28 males and 2 females, aged 26 years in average. RESULTS: Followed up for 17 to 60 months, 93.3% patients reached excellent or good grades. No case fell into the poor grade. CONCLUSION: Because the great adductor muscular tendon is adjacent to the knee joint and similar to the knee ligament, it is appropriate to repair knee ligament. Transposition of the great adductor muscular tendon pedicled vessels is effective in the reconstruction of the medial collateral ligament defect of knee joint.

    Release date:2016-09-01 10:21 Export PDF Favorites Scan
  • The Clinical Outcome of Anatomical Reconstruction of the Patellar Tendon Using a Y-shaped Flap Folded Back from the Vastus Lateralis Fascia

    目的 评价股外侧肌远端筋膜瓣折叠修复重建陈旧性髌韧带断裂的安全性及临床疗效。 方法 对2008年6月-2010年10月收治的10 例陈旧性髌韧带断裂患者,采用股外侧肌远端筋膜瓣折叠联合减张钢丝张力带固定方法重建髌韧带。术后1、2、3、6及12个月随访,采用美国膝关节协会评分对膝关节功能进行评分,包括膝关节疼痛、行走能力和上下楼梯能力、活动度等,同时行超声检查对膝关节髌韧带的连续性进行评估。 结果 10例患者中9 例获得随访,平均随访12个月(6~15个月)。末次随访时平均膝关节疼痛评分、功能评分、膝关节活动范围均较术前明显改善。超声检查显示所有患者肌腱完全愈合,连续性完好,不需要进一步外科手术干预。所有随访患者均未发生手术相关并发症。 结论 采用股外侧肌远端筋膜瓣折叠重建陈旧性髌韧带断裂是一种有效、可靠的方法,能够恢复良好的膝关节功能。

    Release date:2016-09-07 02:37 Export PDF Favorites Scan
  • CLINICAL STUDY ON SURGICAL REPAIR OF ACUTE ACROMIOCLAVICULAR DISLOCATION BY MODIFIED WEAVER-DUNN TECHNIQUE

    Objective To investigate the clinicalvalue of modified Weaver-Dunn technique in repair of acute acromioclavicular dislocation. Methods From January 1993 to December 1998, 18 cases of acromioclavicular dislocation were treated bymodified Weaver-Dunn technique, and other 17 cases of the same suffering were treated by tension band fixation of the acromioclavicular joints. All of the patients were followed up for 12-36 months before clinical evaluation of the functionof shoulder joints, according to University of Pennsylvanian Shoulder Score System. Results In short term, the shoulder joints recovered much more rapidly in the cases repaired by modified Weaver-Dunn technique; 12, 24 and 36 months after operation, the scores of the cases repaired by modified Weaver-Dunn technique were (1897±67), (193.7±3.6) and (194.7±3.4) respectively according to the Shoulder Score System, while those of the cases treated by tension band fixation were (167.3±7.8), (170.2±6.3) and (165.6±5.9) respectively. The above data indicated that there was significant difference between two groups (P<0.05). Conclusion The modified Weaver-Dunn technique was a better surgical approach than tension band fixation for repair of acute acromioclavicular dislocation.

    Release date: Export PDF Favorites Scan
  • HISTOLOGICAL OBSERVATION OF TENDON-BONE HEALING AFTER ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION BY PLATELET-RICH PLASMA COMBINED WITH DEPROTEINIZED BONE OF CALF/

    Objective The tendon-bone heal ing is the key point to ensure the success of the anterior cruciate l igament (ACL) reconstruction. To observe the histological change in the tendon-bone heal ing after ACL reconstruction by different concentrations of platelet-rich plasma (PRP) combined with deproteinized bone (DPB) of calf as bone tunnel infill ing and to investigate the active effect of the complex on tendon-bone heal ing and to define the optimal concentration of PRP. Methods Eight mL blood was drawn from central artery of New Zealand rabbit ears; PRP was prepared by Landesbergmethod, and l iquid supernatant was used as thinner to prepare different concentrations of PRP (30%, 60%, and 100%). Fresh osteoepiphysis spongy bone was harvested from lower end of femur of newborn calf to prepare DPB by way of 30% H2O2 and ether alternating soaking for 24 hours continuous 6 times. DPB was soaked in different concentrations of PRP and mixed with activator to prepare the PRP/DPB complex. A total of 54 New Zealand white rabbits, aging 8-12 months, weighing (2.5 ± 0.4) kg, were divided randomly into 3 groups: group A (30%PRP/DPB complex, n=18), group B (60%PRP/DPB complex, n=18), and group C (100%PRP/DPB complex, n=18). The legs of the rabbits were randomly divided into experimental side and the control side; ACL was reconstructed by semitendinosus and PRP/DPB complex in bone tunnel in the experimental side, and only by semitendinosus in the control side. The general conditions of the rabbits were observed postoperatively and HE staining was used to observe the tendon-bone heal ing, then I-IV levels of semi-quantitative analysis of the tendon-bone heal ing were evaluated according to Demirag standard at 3, 6, and 12 weeks. Results General observation: Synovial fluid sl ightly increased in the specimens and no bony tissue was found in inner of femoral tunnel at 3 weeks; there was no synovial fluid in all the specimens and scar tissue was discovered in inner of femoral tunnel at 6 weeks; and there was no synovial fluid and the tendons became tighter with fibrous tissue at 12 weeks. Histological observation: New granulation tissue formed in the tendon-bone interface of group A experimental sides at 3 weeks; there was various widths of Sharpey type textile fiber in the tendon-bone interface at 6 weeks; Sharpey type textile fiber arranged regularly, which formed an irregular and blur “tidal l ine” at 12 weeks. Group B experimental sides were better than any other group at 3, 6, and 12 weeks; chondrocyte-l ike arranged regularly in the tendonboneinterface at 3 weeks; the number of chondrocyte-l ike per unit area was more than that of the other groups at 6 weeks;and chondrocyte-l ike prol iferated and matured in the tendon-bone interface, Sharpey type textile fiber became tighter andordered. Group C experimental sides were similar to both sides of group A at 3 weeks, however, the prol iferation of relatively mature dense connective tissue was worse than that of other groups at 6 and 12 weeks. According to Demirag grading, there were significant differences in tendon-bone heal ing between the experimental sides and the control sides of group B at 3 and 6 weeks, and between group B experimental sides and group C experimental sides at 12 weeks (P lt; 0.05). Conclusion The mixture of PRP/PRP has good biocompatibil ity and bone induction, so it can enhance tendon-bone heal ing after ACL reconstruction when the concentration of PRP is 60%.

    Release date:2016-09-01 09:04 Export PDF Favorites Scan
  • Clinical evaluations of anterior cruciate ligament reconstruction with platelet rich plasma

    Objective To investigate the clinical outcomes of autologous platelet rich plasma (PRP) for anterior cruciate ligament (ACL) reconstruction. Methods Between August 2014 and August 2016, 42 patients with ACL ruptures who underwent arthroscopic ACL reconstruction were randomly divided into 2 groups: 21 patients received graft soaked with PRP (trial group) and 21 patients received routine graft in ACL reconstruction (control group). Because 6 patients failed to be followed up, 17 patients of trial group and 19 of control group were enrolled in the study. There was no significant difference in gender, age, body mass index, side, injury reason, disease duration, Kellgren-Lawrence grade, and preoperative visual analogue scale (VAS), Lysholm score, and International Knee Documentation Committee (IKDC) activity scores between 2 groups (P>0.05). VAS score, Lysholm score, and IKDC activity scores were used to evaluate pain and function at 3 and 12 months postoperatively. Further, second arthroscopy and MRI examination were performed at 12 months postoperatively. Results The patients in both groups were followed up 3 to 12 months with an average of 9.83 months. The VAS score, Lysholm score, and IKDC activity scores were significantly improved at 3 and 12 months after operation in 2 groups (P<0.05), and the scores of trial group were significantly better than those of control group at 3 months (P<0.05), but no significant difference was found between 2 groups at 12 months (P>0.05). No complications of effusion, infection, and allergy were observed in 2 groups during follow-up. MRI showed good position of ACL grafts and good signal quality of the graft in the majority of the cases. However, mixed hyperintense and presence of synovial fluid at the femoral bone-tendon graft interface were found in 3 patients of trial group and 4 patients of control group, indicating poor remodeling ligamentation. MRI score was 3.53±1.13 in trial group and was 3.21±0.92 in control group, showing no significant difference (t=0.936,P=0.356). The second arthroscopy examination showed ligament remodeling score was higher in trial group than control group (t=3.248,P=0.014), but no significant difference was found in synovial coverage score and the incidence of cartilage repair (t=2.190,P=0.064;χ2=0.090,P=0.764). Conclusion PRP application in allograft ACL reconstruction can improve knee function and relieve pain after operation, which may also accelerate graft remodeling.

    Release date:2017-04-12 11:26 Export PDF Favorites Scan
  • 关节镜下自体髌腱重建前交叉韧带五例

    Release date:2016-09-01 09:33 Export PDF Favorites Scan
  • MODIFIED ROBOTIZED HYDRAULIC TENSOR FOR LIGAMENT BALANCE IN TOTAL KNEE ARTHROPLASTY

    Objective To investigate a modified robotized hydraulictensor for management of the ligament balance in the total knee arthroplasty. Methods The effect of the modified robotized hydraulic tensor on the mechanical behaviour of the ligament system balance in the total knee arthroplasty was analyzed andthe related information was obtained. Results The robotized hydraulic tensor acted as a tensorsensor system, which could assist the surgeon by providing thequantitative information to align the lower limb in extension, equalize the articular spaces in extension and flexion, balance the internal and external forces, and define the femoral component rotation, and by providing the information toplan the releasing of the soft tissues and the rotating of the femoral component. Conclusion The modified robotized hydraulic tensor can enable the surgeon to properly manage the ligament balance in the total knee arthroplasty.

    Release date:2016-09-01 09:20 Export PDF Favorites Scan
  • DESIGN OF NONINVASIVE STEEL MINIPLATE FOR TENODESIS AND ITS CLINICAL APPLICATION

    To fix the ligaments, tendons or other transplantation materials by passing through bone channels was commonly used and a relialde method in the reconstruction of joint stability. Usually an additional incision was necessary on the side of the outlet of the bone channel, that the screws, plates or U-shaped staple could be applied. An instrument was designed that the steel miniplate could be fixed to the bone by noninvasive method. This technique was applied in 20 cases in which anterior cruciate ligament in 14, posterior cruciate ligament in 4, and collateral ligaments in 2 with carbon fibers. The result was successful in all patients. It was shown that it gave simple manipulation, reliable fixation and no need to have an additional incision, and it could lessen patients’ suffering and lead to satisfactory clinical result.

    Release date:2016-09-01 11:08 Export PDF Favorites Scan
  • Effect of Kartogenin combined with adipose-derived stem cells on tendon-bone healing after anterior cruciate ligament reconstruction

    Objective To investigate the effect of Kartogenin (KGN) combined with adipose-derived stem cells (ADSCs) on tendon-bone healing after anterior cruciate ligament (ACL) reconstruction in rabbits. Methods After the primary ADSCs were cultured by passaging, the 3rd generation cells were cultured with 10 μmol/L KGN solution for 72 hours. The supernatant of KGN-ADSCs was harvested and mixed with fibrin glue at a ratio of 1∶1; the 3rd generation ADSCs were mixed with fibrin glue as a control. Eighty adult New Zealand white rabbits were taken and randomly divided into 4 groups: saline group (group A), ADSCs group (group B), KGN-ADSCs group (group C), and sham-operated group (group D). After the ACL reconstruction model was prepared in groups A-C, the saline, the mixture of ADSCs and fibrin glue, and the mixture of supernatant of KGN-ADSCs and fibrin glue were injected into the tendon-bone interface and tendon gap, respectively. ACL was only exposed without other treatment in group D. The general conditions of the animals were observed after operation. At 6 and 12 weeks, the tendon-bone interface tissues and ACL specimens were taken and the tendon-bone healing was observed by HE staining, c-Jun N-terminal kinase (JNK) immunohistochemical staining, and TUNEL apoptosis assay. The fibroblasts were counted, and the positive expression rate of JNK protein and apoptosis index (AI) were measured. At the same time point, the tensile strength test was performed to measure the maximum load and the maximum tensile distance to observe the biomechanical properties. Results Twenty-eight rabbits were excluded from the study due to incision infection or death, and finally 12, 12, 12, and 16 rabbits in groups A-D were included in the study, respectively. After operation, the tendon-bone interface of groups A and B healed poorly, while group C healed well. At 6 and 12 weeks, the number of fibroblasts and positive expression rate of JNK protein in group C were significantly higher than those of groups A, B, and D (P<0.05). Compared with 6 weeks, the number of fibroblasts gradually decreased and the positive expression rate of JNK protein and AI decreased in group C at 12 weeks after operation, with significant differences (P<0.05). Biomechanical tests showed that the maximum loads at 6 and 12 weeks after operation in group C were higher than in groups A and B, but lower than those in group D, while the maximum tensile distance results were opposite, but the differences between groups were significant (P<0.05). Conclusion After ACL reconstruction, local injection of a mixture of KGN-ADSCs and fibrin glue can promote the tendon-bone healing and enhance the mechanical strength and tensile resistance of the tendon-bone interface.

    Release date:2023-08-09 01:37 Export PDF Favorites Scan
44 pages Previous 1 2 3 ... 44 Next

Format

Content