west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "骨质疏松" 176 results
  • Effect of core stabilization exercise with unstable support surface on rehabilitation of patients with osteoporotic vertebral fracture

    ObjectiveTo analyze the effect of core stabilization exercise with unstable support surface on rehabilitation of patients with osteoporotic vertebral fracture.MethodsFrom January 2018 to January 2020, 66 patients with osteoporotic vertebral fractures in the Fifth Affiliated Hospital of Zhengzhou University were selected as the research objects. All patients were treated with percutaneous vertebroplasty. After operation, they were randomly divided into intervention group and control group by random number table method, with 33 cases in each group. Both groups were given routine rehabilitation intervention after operation, while the intervention group was given core stabilization exercise with unstable support surface at the same time. The vertebral height, shape, stability and gait of the two groups were compared 1 day before operation and 1 day after rehabilitation training.ResultsThere was no significant difference in gender, age, injured vertebral body, course of osteoporosis, years of education and marital status between the two groups (P>0.05). Before surgery, there was no statistically significant difference in the height ratio of the front edge of the injured vertebra, middle height ratio of the injured vertebra, back convex Cobb angle, track length when eyes were open, track length when eyes were closed, Romberg rate, track length per unit time when eyes were open, track length per unit time when eyes were closed, Romberg rate per unit time, deviation of the center of gravity on X-axis when eyes were open, deviation of the center of gravity on X-axis when eyes were closed, deviation of the center of gravity on Y-axis when eyes were open, deviation of the center of gravity on Y-axis when eyes were closed, stride length, step frequency or comfortable pace between the two groups (P>0.05). After training, the height ratio of the front edge of the injured vertebra [(79.26±12.15)% vs. (72.26±13.36)%], middle height ratio of the injured vertebra [(82.11±10.26)% vs. (75.64±9.56)%], back convex Cobb angle [(9.87±7.10) vs. (14.41±2.36)°], track length when eyes were closed [(1856.29±457.16) vs. (2358.48±786.45) mm], Romberg rate [(1.32±0.29)% vs. (1.87±0.54)%], track length per unit time when eyes were closed [(33.45±3.26) vs. (41.55±4.69) mm], Romberg rate per unit time [(1.41±0.30)% vs. (1.95±0.77)%], deviation of the center of gravity on X-axis when eyes were open [(11.06±1.36) vs. (16.54±2.22) mm], deviation of the center of gravity on X-axis when eyes were closed [(11.15±0.96) vs. (23.31±3.06) mm], deviation of the center of gravity on Y-axis when eyes were open [(12.57±1.84) vs. (15.56±2.06) mm], deviation of the center of gravity on Y-axis when eyes were closed [(15.69±2.05) vs. (18.96±3.56) mm], stride length [(0.57±0.12) vs. (0.49±0.10) m], step frequency [(1.09±0.29) vs. (0.94±0.20) step/s] and comfortable pace [(0.35±0.12) vs. (0.29±0.10) m/s] of the intervention group were better than those of the control group (P<0.05). There was no significant difference in the track length when eyes were open or track length per unit time when eyes were open between the two groups (P>0.05).ConclusionIn patients with osteoporotic vertebral body fractures, core stabilization exercise with unstable support surface on the basis of conventional rehabilitation interventions after surgery can effectively restore the height and shape of the vertebral body, and improve the stability and gait to a certain extent.

    Release date:2021-09-24 01:23 Export PDF Favorites Scan
  • Biomechanical study of a newly-designed Y type pedicle screw in osteoporotic synthetic bone

    Objective To evaluate the biomechanical stability of a newly-designed Y type pedicle screw (YPS) in osteoporotic synthetic bone. Methods The osteoporotic synthetic bone were randomly divided into 3 groups (n=20). A pilot hole, 3.0 mm in diameter and 30.0 mm in deep, was prepared in these bones with the same method. The YPS, expansive pedicle screw (EPS), and bone cement-injectable cannulated pedicle screw (CICPS) were inserted into these synthetic bone through the pilot hole prepared. X-ray film examination was performed after 12 hours; the biomechanical stability of YPS, EPS, and CICPS groups was tested by the universal testing machine (E10000). The test items included the maximum axial pullout force, the maximum running torque, and the maximum periodical anti-bending. Results X-ray examination showed that in YPS group, the main screw and the core pin were wrapped around the polyurethane material, the core pin was formed from the lower 1/3 of the main screw and formed an angle of 15° with the main screw, and the lowest point of the inserted middle core pin was positioned at the same level with the main screw; in EPS group, the tip of EPS expanded markedly and formed a claw-like structure; in CICPS group, the bone cement was mainly distributed in the front of the screw and was dispersed in the trabecular bone to form a stable screw-bone cement-trabecular complex. The maximum axial pullout force of YPS, EPS, and CICPS groups was (98.43±8.26), (77.41±11.41), and (186.43±23.23) N, respectively; the maximum running torque was (1.42±0.33), (0.96±0.37), and (2.27±0.39) N/m, respectively; and the maximum periodical anti-bending was (67.49±3.02), (66.03±2.88), and (143.48±4.73) N, respectively. The above indexes in CICPS group were significantly higher than those in YPS group and EPS group (P<0.05); the maximum axial pullout force and the maximum running torque in YPS group were significantly higher than those in EPS group (P<0.05), but there was no significant difference in the maximum periodical anti-bending between YPS group and EPS group (P>0.05). Conclusion Compared with EPS, YPS can effectively enhance the maximum axial pullout force and maximum rotation force in the module, which provides a new idea for the design of screws and the choice of different fixation methods under the condition of osteoporosis.

    Release date:2017-10-10 03:58 Export PDF Favorites Scan
  • Effects of different puncture levels in bilateral percutaneous vertebroplasty on distribution of bone cement and effectiveness of osteoporotic thoracolumbar compression fractures

    Objective To investigate the effects of different puncture levels on bone cement distribution and effectiveness in bilateral percutaneous vertebroplasty for osteoporotic thoracolumbar compression fractures. Methods A clinical data of 274 patients with osteoporotic thoracolumbar compression fractures who met the selection criteria between December 2017 and December 2020 was retrospectively analyzed. All patients underwent bilateral percutaneous vertebroplasty. During operation, the final position of the puncture needle tip reached was observed by C-arm X-ray machine. And 118 cases of bilateral puncture needle tips were at the same level (group A); 156 cases of bilateral puncture needle tips were at different levels (group B), of which 87 cases were at the upper 1/3 layer and the lower 1/3 layer respectively (group B1), and 69 cases were at the adjacent levels (group B2). There was no significant difference in gender, age, fracture segment, degree of osteoporosis, disease duration, and preoperative visual analogue scale (VAS) score, and Oswestry disability index (ODI) between groups A and B and among groups A, B1, and B2 (P>0.05). The operation time, bone cement injection volume, postoperative VAS score, ODI, and bone cement distribution were compared among the groups. Results All operations were successfully completed without pulmonary embolism, needle tract infection, or nerve compression caused by bone cement leakage. There was no significant difference in operation time and bone cement injection volume between groups A and B or among groups A, B1, and B2 (P>0.05). All patients were followed up 3-32 months, with an average of 7.8 months. There was no significant difference in follow-up time between groups A and B and among groups A, B1, and B2 (P>0.05). At 3 days after operation and last follow-up, VAS score and ODI were significantly lower in group B than in group A (P<0.05), in groups B1 and B2 than in group A (P<0.05), and in group B1 than in group B2 (P<0.05). Imaging review showed that the distribution of bone cement in the coronal midline of injured vertebrae was significantly better in group B than in group A (P<0.05), in groups B1 and B2 than in group A (P<0.05), and in group B1 than in group B2 (P<0.05). In group A, 7 cases had postoperative vertebral collapse and 8 cases had other vertebral fractures. In group B, only 1 case had postoperative vertebral collapse during follow-up. ConclusionBilateral percutaneous vertebroplasty in the treatment of osteoporotic thoracolumbar compression fractures can obtain good bone cement distribution and effectiveness when the puncture needle tips locate at different levels during operation. When the puncture needle tips locate at the upper 1/3 layer and the lower 1/3 layer of the vertebral body, respectively, the puncture sites are closer to the upper and lower endplates, and the injected bone cement is easier to connect with the upper and lower endplates.

    Release date:2023-03-13 08:33 Export PDF Favorites Scan
  • PEDICLE SUBTRACTION OSTEOTOMY ASSISTED WITH ANTERIOR COLUMN RECONSTRUCTION FOR TREATMENT OF CHRONIC OSTEOPOROTIC VERTEBRAL COMPRESSION FRACTURE

    ObjectiveTo evaluate the effectiveness of pedicle subtraction osteotomy (PSO) assisted with anterior column reconstruction in the treatment of chronic osteoporotic vertebral compression fracture (OVCF). MethodsBetween January 2008 and October 2014, 11 cases of chronic OVCF were treated. There were 2 males and 9 females, aged 65-76 years (mean, 72.3 years). The vertebral compression fracture segment involved T11 in 2 cases, T12 in 2 cases, L1 in 4 cases, L2 in 2 cases, and L3 in 1 case. At preoperation, the Oswestry disability index (ODI) score was 31.1±10.2; kyphosis Cobb angle of fractured vertebrae was (36.5±10.2)° on the lateral X-ray films of the spine; and distance between C7 plumb vertical line (C7 PL) and sagittal vertical axis (SVA) of the S1 superior border was (5.2±2.5) cm. Six cases had spinal cord injury (SCI), including 4 cases of Frankel grade C and 2 cases of grade D. At last follow-up, ODI score, kyphosis Cobb angle of fractured vertebrae, and distance between C7 PL and SVA were recorded and compared with preoperative values. Postoperative Frankle scores were recorded in SCI cases. X-ray film and CT scan were taken to evaluate bone fusion at 12 months after operation. ResultsThe operation was completed successfully without serious complications. Nerve root radiation symptoms occurred in 2 cases undergoing lumbar PSO, which was relieved after conservative treatment. Cerebrospinal fluid leakage occurred in 1 case and was cured after 2 weeks. All cases were followed up 12-24 months (mean, 15.6 months). No internal fixation failure or pseudarthrosis was found postoperatively.Screw loosening was found in 1 case (2 screws of the upper level) and titanium Cage cutting vertebral body was found in 1 case. Bone fusion was obtained in all cases at 12 months after operation. At last follow-up, ODI score was significantly improved to 13.7±5.7(t=4.417, P=0.018), kyphosis Cobb angle of fractured vertebrae to (7.0±15.2)° (t=5.113, P=0.009), and the distance between C7 PL and SVA to (2.8±2.2) cm (t=3.285, P=0.032). In 6 SCI cases, Frankle grade was recovered to E (1 case), to D (1 case), and no improvement (2 cases) from C, and to E from D (2 cases). ConclusionPSO assisted anterior column reconstruction was an effective method in treatment of chronic OVCF.

    Release date: Export PDF Favorites Scan
  • 股骨近端锁定钢板治疗老年股骨转子间骨折

    目的 总结股骨近端锁定钢板在治疗老年股骨转子间骨折的手术经验及成功率。 方法 对2008年1月-2009年3月收治的57例老年股骨转子间骨折患者,行切开复位股骨近端锁定钢板内固定治疗。 结果 在Evans分型1~5型中手术成功率为100%,优良率为98.2%。 结论 股骨近端锁定钢板适用于老年股骨转子间骨折的各种类型。

    Release date:2016-09-08 09:47 Export PDF Favorites Scan
  • Observation on the Effect of Glucosamine Hydrochloride Combined with Antiosteoporosis Drugs in the Treatment of Senile Knee Osteoarthritis

    ObjectiveTo observe the clinical effect of combined glucosamine hydrochloride and antiosteoporosis drugs in the treatment of senile knee osteoarthritis. MethodsA total of 120 patients with osteoarthritis of the knee treated from January 2014 to December 2015 were randomly divided into observation group and control group with 60 cases in each. The observation group received not only oral glucosamine hydrochloride, but calcium D3, alfacalcidol, and sodium phosphate for anti-osteoporosis treatment, while the control group was only given oral glucosamine hydrochloride. Lequesne score, curative effect and adverse drug reactions were compared between the two groups 2, 4, and 6 weeks after the beginning of treatment. ResultsWithin two weeks of treatment, there was no significant difference between the two groups in the effective rate (P > 0.05) . But four and six weeks after treatment, the efficiency in the observation group was significantly higher than that in the control group (χ2=6.806, P < 0.01; χ2=24.762, P < 0.01) . Four and six weeks after treatment, Lequesne score of the observation group was significantly lower than that of the control group (t=2.199, P < 0.05; t=4.748, P < 0.001) . There was no significant difference in terms of adverse reactions between the two groups before and after treatment (χ2=0.617, P > 0.05) . ConclusionCompared with single hydrochloric amino glucose treatment, glucosamine hydrochloride combined with anti-osteoporosis treatment for senile knee osteoarthritis has better treatment effect without increase in adverse drug reactions, and it is worth of clinical application.

    Release date: Export PDF Favorites Scan
  • Comparison of short-segment and long-segment bone cement-augmented fixation combined with vertebroplasty in treatment of stage Ⅲ Kümmell disease

    ObjectiveTo compare the effectiveness of short-segment and long-segment bone cement-augmented fixation combined with vertebroplasty in treatment of stage Ⅲ Kümmell disease.MethodsA clinical data of 44 patients with stage Ⅲ Kümmell disease met the selection criteria between January 2014 and December 2017 was retrospectively analyzed. Eighteen cases were treated with short-segment bone cement-augmented fixation combined with vertebroplasty (short-segment group) and 26 cases were treated with long-segment bone cement-augmented fixation combined with vertebroplasty (long-segment group). There was no significant difference in gender, age, disease duration, fracture segment, bone mineral density (T value), Frankle grading, and preoperative pain visual analogue scale (VAS) score, Oswestry disability index (ODI), anterior edge height of injured vertebrae, kyphosis Cobb angle, and thoracolumbar kyphosis (TLK) between the two groups (P>0.05). The operation time, intraoperative blood loss, bone cement injection volume, bone cement leakage rate, VAS score, ODI, anterior edge height of injured vertebrae, kyphosis Cobb angle, and TLK were compared between the two groups.ResultsThe operation time and the intraoperative blood loss in the short- segment group were significant lower than those in the long-segment group (P<0.05). There was no significant difference in bone cement injection volume and bone cement leakage rate between the two groups (P>0.05). All patients were followed up 12-36 months, with an average of 24.4 months. The VAS score, ODI, anterior edge height of injured vertebrae, kyphosis Cobb angle, and TLK significantly improved at 1 week after operation and last follow-up in the two groups (P<0.05), there was no significant difference between the two groups (P>0.05). At last follow-up, the neurological function of the two groups recovered, and there was no significant difference in Frankle grading between the two groups (P>0.05). There were 3 cases (16.67%) of non-surgical vertebral fractures in the short-segment group and 6 cases (23.08%) in the long-segment group, showing no significant difference between the two groups (P>0.05). Bone rejection occurred in 1 case in the short-segment group, and neither internal fixation failure nor collapse of the injured vertebrae occurred during follow-up.ConclusionBoth short-segment and long-segment bone cement-augmented fixation combined with vertebroplasty can achieve good effectiveness in treatment of stage Ⅲ Kümmell disease, and can maintain the height of the injured vertebra and prevent the collapse of the injured vertebra. Compared with long-segment fixation, short-segment fixation has the advantages of shorter operation time and less intraoperative bleeding.

    Release date:2020-11-02 06:24 Export PDF Favorites Scan
  • DIFFERENT SURGICAL METHODS FOR TREATMENT OF SENILE OSTEOPOROTIC COMMINUTED PROXIMAL HUMERUS FRACTURE

    Objective To compare the efficacy and indication of the three different surgical methods in the treatment of the senile osteoporotic comminuted proximal humerus fracture. Methods From January 2006 to April 2008, 70 senile patients with osteoporotic comminuted proximal humerus fracture were randomly divided into three groups to receive different surgical methods. There were 21 patients in the group A receiving Kirschner tension band or screw internal fixation, 37 patients in group B receiving internal fixation of locking proximal humeral plate, and 12 patients in group C receiving humeral head replacement. There were 36 males and 34 females aged 53-76 years old (average 61.9 years old). All the fractureswere closed, osteoporotic, and III and IV-part according to Neer classification. The disease course was 1-8 days (average 2.8 days). There was no significant difference among three groups in terms of basel ine information (P gt; 0.05). The effective antiosteoporosis therapy was given during perioperative period. Results All the incision healed by first intention. All patients reached anatomical or almost anatomical reduction without compl ications such as postoperative infection, neurovascular injury, and nonunion of bone. Seventy patients were followed up for 9-20 months (average 11.5 months). The heal ing time of the fracture was 8-12 weeks in group A and group B, the average heal ing time was 10.5 weeks in group A and 10 weeks in group B, and there was no significant difference between two groups (P gt; 0.05). Group C presented with no sign of prosthesis loosening or shoulder dislocation. Six cases in group A suffered from frozen shoulder, pain or acromion impingement syndrome 6 months after operation and obtained various degrees of improvement via functional exercises. One of them had humeral head avascular necrosis 12 months later and achieved fair recovery after performing humeral head replacement. Two cases in group B had frozen and painful shoulder 6 months after operation and achieved fair recovery after functional exercises. One cases in group C had frozen shoulder and poor performance of abduction and upl ifting and achieved improvement after exercises. The rest patients achieved satisfactory curative effects. The incidence of compl ication was 28.6% in group A, 5.4% in group B, and 8.3% in group C. The incidence of complication in group A was significantly higher than that of group B and group C (P lt; 0.05), and there was no significant difference between group B and group C (P gt; 0.05). Neer scale system was adopted to evaluate the postoperative shoulder function, the excellent and good rate was 66.7% in group A, 78.4% in group B, and 83.3% in group C. The excellent and good rate in group A was significantly less than that of group B and group C (P lt; 0.05), and there was no significant difference between group B and group C (P gt; 0.05). Conclusion The senile osteoporotic comminuted proximal humerus fracture treated by surgery can obtain satisfied results. Most patients can use locking plate fixation. Those with poor general condition can use Kirschner wire fixation with tension band or screws, but this method is subject to certain constraints. For some elder patients with humeral head necrosis and humeral head crushed, priority should be given to the use of humeral head replacement.

    Release date:2016-09-01 09:08 Export PDF Favorites Scan
  • Preliminary study on osteoporosis screening among postmenopausal patients with maintenance hemodialysis

    ObjectiveTo preliminarily explore the effect of Osteoporosis Self-assessment Tool for Asians (OSTA) and Fracture Risk Assessment Tool (FRAX) on predicting osteoporosis and osteoporosis fracture in postmenopausal patients with maintenance hemodialysis (MHD).MethodsThirty-six postmenopausal patients undergoing MHD from August 2017 to October 2018 in Hemodialysis Center of Nephrology Department, West China Hospital of Sichuan University were selected. Relevant data such as age, height, and weight were collected. OSTA index and the 10-year probability of major osteoporotic fractures and 10-year probability of hip fractures of FRAX score were calculated. Bone mineral densities (BMD) of the hip and lumbar spine were measured by dual energy X-ray absorptiometry (DXA) at the same time. The value of OSTA index and FRAX scale in evaluating the risk of osteoporosis predicated on T value ≤−2.5 determined by DXA BMD and fracture in postmenopausal patients with MHD were analyzed.ResultsThe DXA BMD of the 36 patients showed that 50.0% (18/36) had a T value≤−2.5, and 30.6% (11/36) had a fracture history. BMD in postmenopausal patients with MHD was negatively correlated with FRAX score (model without BMD values), and positively correlated with OSTA index. The sensitivity and specificity of OSTA in the prediction of osteoporosis were 94.4% and 61.1%, respectively; and the sensitivity and specificity of FRAX (the model without BMD values) in the prediction of osteoporosis were 88.9% and 50.0%, respectively. The FRAX score with or without BMD had the same clinical value in predicting osteoporosis.ConclusionsPostmenopausal MHD patients have a higher risk of osteoporosis and fracture. Both OSTA index and FRAX scale can predict osteoporosis risk among postmenopausal MHD patients, and the FRAX scale with or without BMD has the same clinical value in predicting osteoporosis risk. In clinical work, for primary hospitals and dialysis centers lacking DXA, preliminary screening of osteoporosis in MHD patients can be performed with OSTA and FRAX scales.

    Release date:2019-08-15 01:18 Export PDF Favorites Scan
  • Photoelectric guided navigation unilateral puncture of the percutaneous kyphoplasty in treatment of thoracolumbar osteoporotic vertebral compression fracture

    ObjectiveTo evaluate the safety of photoelectric guided navigation unilateral puncture of the percutaneous kyphoplasty (PKP) in the treatment of thoracolumbar osteoporotic vertebral compression fracture (OVCF).MethodsA randomized controlled clinical research was performed between June 2015 and January 2017. Eighty-five cases of OVCF were treated with photoelectric guided navigation unilateral puncture of the PKP (trial group, 43 cases) or C arm fluoroscopy unilateral puncture of the PKP (control group, 42 cases) respectively. There was no significant difference in gender, age, disease duration, segmental fracture, AO classification, bone mineral density, and preoperative visual analogue scale (VAS) score between 2 groups (P>0.05). The concordance rate of puncture path and design path, the incidence of pedicle wall breaking, the incidence of bone cement leakage, and the rate of bone cement distribution center were observed and calculated on postoperative CT images; the intraoperative X-ray exposure frequency, frequency of puncture, operation time, VAS scores before operation and at 2 days after operation, and postoperative blood vessel or nerve injury were recorded and compared.ResultsThe intraoperative X-ray exposure frequency and puncture frequency in trial group were significantly less than those in control group (P<0.05), but there was no significant difference in operation time between 2 groups (t=0.440, P=0.661). The VAS scores of 2 groups at 2 days after operation were significantly improved when compared with preoperative ones (P<0.05), but there was no significant difference in VAS score at 2 days after operation between 2 groups (t=0.406, P=0.685). All the patients were followed up 6-18 months (mean, 10 months). No blood vessel or nerve injury occurred in 2 groups. The incidence of pedicle wall breaking, the incidence of bone cement leakage, the concordance rate of puncture path and design path, and the rate of bone cement distribution center in trial group were 2.33% (1/43), 2.33% (1/43), 86.05% (37/43), and 88.37% (38/43) respectively, all showing significant differences when compared with those of control group [19.05% (8/42), 21.43% (9/42), 45.24% (19/42), and 50.00% (21/42) respectively] (P<0.05).ConclusionIntraoperative photoelectric guided navigation unilateral puncture of the PKP can improve the success rate of target puncture and reduce the incidence of pedicle wall breaking effectively, and achieve better bone cement distribution and better security.

    Release date:2018-02-07 03:21 Export PDF Favorites Scan
18 pages Previous 1 2 3 ... 18 Next

Format

Content