west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "3D 打印技术" 25 results
  • Clinical study of three-dimensional printed navigation template assisted Ludloff osteotomy in treatment of moderate and severe hallux valgus

    ObjectiveTo explore the effectiveness and advantage of three-dimensional (3D) printed navigation templates assisted Ludloff osteotomy in treatment of moderate and severe hallux valgus.MethodsBetween April 2013 and February 2015, 28 patients (28 feet) with moderate and severe hallux valgus who underwent Ludloff osteotomy were randomly divided into 2 groups (n=14). In group A, the patients were treated with Ludloff osteotomy assissted with a 3D printed navigation template. In group B, the patients were treated with traditional Ludloff osteotomy. There was no significant difference in gender, age, affected side, and clinical classification between 2 groups (P>0.05). The operation time and intraoperative blood loss were recorded. The ankle function of the foot at preoperation, immediate after operation, and last follow-up were assessed by the American Orthopedic Foot and Ankle Society (AOFAS) score. Besides, the X-ray film were taken to assess the hallux valgus angle (HVA), intermetatarsal angle (IMA), and the first metatarsal length shortening.ResultsAll patients were followed up 18-40 months (mean, 26.4 months). The operation time and intraoperative blood loss in group A were significantly less than those in group B (P<0.05). The HVA, IMA, and AOFAS scores in groups A and B at immediate after operaton and last follow-up were sinificantly improved when compared with preoperative values (P<0.05); but no significant difference was found between at immediate after operation and at last follow-up (P>0.05). No significant difference was found in HVA and IMA between group A and group B at difference time points (P>0.05). There were significant differences in AOFAS score and the first metatarsal length shortening at immediate after operation and at last follow-up between 2 groups (P<0.05). Except 1 case of metastatic metatarsalgia in group B, there was no other operative complications in both groups.Conclusion3D printed navigation template assisted Ludloff osteotomy can provide accurate preoperative planning and intraoperative osteotomy. It is an ideal method for moderate and severe hallux valgus.

    Release date:2018-07-12 06:19 Export PDF Favorites Scan
  • Treatment of giant cell tumor of bone around knee joint with three-dimensional printing personalized prosthesis

    ObjectiveTo investigate the short-term effectiveness of three-dimensional (3D) printing personalized prosthesis in the treatment of giant cell tumor of bone around knee joint.MethodsA clinical data of 9 patients with giant cell tumor of bone around knee joints and met the inclusive criteria between May 2014 and August 2017 was retrospectively analysed. There were 4 males and 5 females, with an average age of 35.8 years (range, 24-50 years). The lesion located at the distal femur in 4 cases and at the proximal tibia in 5 cases. The disease duration was 5-25 months (mean, 12.9 months). According to Campanacci grading, there were 2 patients of grade Ⅰ and 7 of grade Ⅱ. The 3D printing personalized prosthesis was designed based on the CT scanning and 3D reconstruction prepared before operation. All patients were treated with the tumor resection and 3D printing personalized prosthesis reconstruction. The radiological examination was taken to observe the tumor recurrence and the Musculoskeletal Tumor Society 1993 (MSTS93) score was used to evaluate the knee function.ResultsAll operations were successful and all incisions healed by first intention without early complications. All patients were followed up 24-40 months (mean, 31.2 months). At last follow-up, no complication such as pain, pathological fracture, prosthesis loosening, or tumor recurrence occurred. The MSTS93 score was 20-29 (mean, 24.7). The knee function was rated as excellent in 6 cases and good in 3 cases, with the excellent and good rate of 100%. ConclusionFor giant cell tumor of bone around knee joint, 3D printing personalized prosthesis has the advantages of bio-fusion with host bone, mechanical stability, good joint function, and ideal short-term effectiveness. But the middle- and long-term effectiveness still need to be further observed.

    Release date:2020-07-07 07:58 Export PDF Favorites Scan
  • Application of 3D printed lumbar puncture models in orthopedic clinical teaching

    ObjectiveTo explore the feasibility of lumbar puncture models based on 3D printing technology for training junior orthopaedic surgeons to find the optimal pedicle screw insertion points.MethodsMimics software was used to design 3D models of lumbar spine with the optimal channels and alternative channels. Then, the printed lumbar spine models, plasticine, and cloth were used to build lumbar puncture models. From January 2018 to June 2019, 43 orthopedic trainees performed simulated operations to search for the insertion points of pedicle screws base on the models. The operations were performed once a day for 10 consecutive days, and the differences in operation scores and operation durations of the trainees among the 10 days were compared.ResultsAll the trainees completed the surgical training operations successfully, and there were significant differences in the operation scores (13.05±2.45, 14.02±3.96, 17.58±3.46, 21.02±2.04, 23.40±4.08, 25.14±3.72, 27.26±6.09, 33.37±4.23, 35.00±4.15, 38.49±1.70; F=340.604, P<0.001) and operation durations [(22.51±4.28), (19.93±4.28), (18.05±2.89), (17.05±1.76), (16.98±1.97), (15.47±1.74), (13.51±1.42), (12.60±2.17), (12.44±1.71), (11.91±1.87) minutes; F=102.359, P<0.001] among the 10 days.ConclusionThe 3D models of lumbar puncture are feasible and repeatable, which can contribute to surgical training.

    Release date:2019-09-06 03:51 Export PDF Favorites Scan
  • Application of three-dimensional printing technology in treatment of internal or external ankle distal avulsed fracture

    ObjectiveTo explore the effectiveness and advantage of three-dimensional (3D) printing technology in treatment of internal or external ankle distal avulsed fracture.MethodsBetween January 2015 and January 2017, 20 patients with distal avulsed fracture of internal or external ankle were treated with the 3D guidance of shape-blocking steel plate fixation (group A), and 18 patients were treated with traditional plaster external fixation (group B). There was no significant difference in gender, age, injury cause, disease duration, fracture side, and fracture type between 2 groups (P>0.05). Recording the fracture healing rate, fracture healing time, the time of starting to ankle functional exercise, residual ankle pain, and evaluating ankle function recovery of both groups by the American Orthopaedic Foot and Ankle Society (AOFAS) score.ResultsAll patients were followed up 8-24 months, with an average of 15.5 months. In group A: all incisions healed by first intention, the time of starting to ankle functional exercise was (14±3) days, fracture healing rate was 100%, and the fracture healing time was (10.15±2.00) weeks. At 6 months, the AOFAS score was 90.35±4.65. Among them, 13 patients were excellent and 7 patients were good. All patients had no post-operative incision infection, residual ankle pain, or dysfunction during the follow-up. In group B: the time of starting to ankle functional exercise was (40±10) days, the fracture healing rate was 94.44%, and the fracture healing time was (13.83±7.49) weeks. At 6 months, the AOFAS score was 79.28±34.28. Among them, 15 patients were good, 2 patients were medium, and 1 patient was poor. During the follow-up, 3 patients (16.67%) had pain of ankle joint with different degrees. There were significant differences in the postoperative fracture healing rate, fracture healing time, the time of starting to ankle functional exercise, and postoperative AOFAS score between 2 groups (P<0.05).ConclusionApplication of 3D printing technology in treatment of internal or external ankle distal avulsed fracture is simple, safe, reliable, and effective. In particular, it is an ideal treatment for avulsed fracture.

    Release date:2018-02-07 03:21 Export PDF Favorites Scan
  • Applications of 3D printing technology in the treatment of mitral valve disease

    Mitral valve disease is the most common cardiac valve disease. The main treatment of mitral valve disease is surgery or interventional therapy. However, as the anatomy of mitral valve is complicated, the operation is particularly difficult. As a result, it requires sophisticated experiences for surgeons. Three-dimensional (3D) printing technology can transform two-dimensional medical images into 3D solid models. So it can provide clear spatial anatomical information and offer safe and personalized treatment for the patients by simulating surgery process. This article reviews the applications of 3D printing technology in the treatment of mitral valve disease.

    Release date:2019-04-29 02:51 Export PDF Favorites Scan
  • Three-dimensional printed Ti6Al4V-4Cu alloy promotes osteogenic gene expression through bone immune regulation

    ObjectiveTo investigate the effects of three-dimensional (3D) printed Ti6Al4V-4Cu alloy on inflammation and osteogenic gene expression in mouse bone marrow mesenchymal stem cells (BMSCs) and mouse mononuclear macrophage line RAW264.7.MethodsTi6Al4V and Ti6Al4V-4Cu alloys were prepared by selective laser melting, and the extracts of the two materials were prepared according to the biological evaluation standard of medical devices. The effects of two kinds of extracts on the proliferation of mouse BMSCs and mouse RAW264.7 cells were detected by cell counting kit 8 method. After co-cultured with mouse BMSCs for 3 days, the expression of osteogenesis- related genes [collagen type Ⅰ (Col-Ⅰ), alkaline phosphatase (ALP), Runx family transcription factor 2 (Runx-2), osteoprotegerin (OPG), and osteopontin (OPN)] were detected by real-time fluorescence quantitative PCR. After co-cultured with mouse RAW264.7 cells for 1 day, the expressions of inflammation-related genes [interleukin 4 (IL-4) and nitric oxide synthase 2 (iNOS)] were detected by real-time fluorescence quantitative PCR, and the supernatants of the two groups were collected to detect the secretion of vascular endothelial growth factor a (VEGF-a) and bone morphogenetic protein 2 (BMP-2) by ELISA. The osteogenic conditioned medium were prepared with the supernatants of the two groups and co-cultured with BMSCs for 3 days. The expressions of osteogenesis-related genes (Col-Ⅰ, ALP, Runx-2, OPG, and OPN) were detected by real-time fluorescence quantitative PCR.ResultsCompared with Ti6Al4V alloy extract, Ti6Al4V-4Cu alloy extract had no obvious effect on the proliferation of BMSCs and RAW264.7 cells, but it could promote the expression of OPG mRNA in BMSCs, reduce the expression of iNOS mRNA in RAW264.7 cells, and promote the expression of IL-4 mRNA. It could also promote the secretions of VEGF-a and BMP-2 in RAW264.7 cells. Ti6Al4V-4Cu osteogenic conditioned medium could promote the expressions of Col-Ⅰ, ALP, Runx-2, OPG, and OPN mRNAs in BMSCs. The differences were all significant (P<0.05).Conclusion3D printed Ti6Al4V-4Cu alloy can promote RAW264.7 cells to secret VEGF-a and BMP-2 by releasing copper ions, thus promoting osteogenesis through bone immune regulation, which lays a theoretical foundation for the application of metal prosthesis.

    Release date:2020-09-28 02:45 Export PDF Favorites Scan
  • Study on the preparation of polycaprolactone/typeⅠcollagen tissue engineered meniscus scaffold by three-dimensional printing and its physiochemical properties

    ObjectiveTo manufacture a polycaprolactone (PCL)/type Ⅰ collagen (COL Ⅰ) tissue engineered meniscus scaffold (hereinafter referred to as PCL/COL Ⅰ meniscus scaffold) by three-dimensional (3D) printing with low temperature deposition technique and to study its physicochemical properties.MethodsFirst, the 15% PCL/4% COLⅠ composite solution and 15% PCL simple solution were prepared. Then, 15% PCL/4% COL Ⅰmeniscus scaffold and 15% PCL meniscal scaffold were prepared by using 3D printing with low temperature deposition techniques. The morphology and microstructure of the scaffolds were observed by gross observation and scanning electron microscope. The compression modulus and tensile modulus of the scaffolds were measured by biomechanical test. The components of the scaffolds were analyzed by Fourier transform infrared spectroscopy (FTIR). The contact angle of the scaffold surface was measured. The meniscus cells of rabbits were cultured with the two scaffold extracts and scaffolds, respectively. After cultured, the cell proliferations were detected by cell counting kit 8 (CCK-8), and the normal cultured cells were used as controls. Cell adhesion and growth of scaffold-cell complex were observed by scanning electron microscope.ResultsAccording to the gross and scanning electron microscope observations, two scaffolds had orientated 3D microstructures and pores, but the surface of the PCL/COLⅠ meniscus scaffold was rougher than the PCL meniscus scaffold. Biomechanical analysis showed that the tensile modulus and compression modulus of the PCL/COL Ⅰ meniscus scaffold were not significantly different from those of the PCL meniscus scaffold (P>0.05). FTIR analysis results showed that COL Ⅰ and PCL were successful mixed in PCL/ COL Ⅰ meniscus scaffolds. The contact angle of PCL/COLⅠ meniscus scaffold [(83.19±7.49)°] was significantly lower than that of PCL meniscus scaffold [(111.13±5.70)°] (t=6.638, P=0.000). The results of the CCK-8 assay indicated that with time, the number of cells cultured in two scaffold extracts showed an increasing trend, and there was no significant difference when compared with the control group (P>0.05). Scanning electron microscope observation showed that the cells attached on the PCL/ COL Ⅰ meniscus scaffold more than that on the PCL scaffold.ConclusionPCL/COLⅠmeniscus scaffolds are prepared by 3D printing with low temperature deposition technique, which has excellent physicochemical properties without cytotoxicity. PCL/COLⅠmeniscus scaffold is expected to be used as the material for meniscus tissue engineering.

    Release date:2018-09-03 10:13 Export PDF Favorites Scan
  • Advance in research of esophageal stent

    The esophageal disease is a major clinical disease. The esophageal stent has extensive clinical applications in the treatment of esophageal diseases. However, the clinical application of esophageal stent is limited, because there are lots of complications after implantation of esophageal stent. Biodegradable esophageal stent has two advantages: biodegradability and good histocompatibility. It is expected to solve a variety of complications of esophageal stent and provide a new choice for the treatment of esophageal diseases. Standardized esophageal stents are not fully applicable to all patients. The application of 3D printing technology in the manufacture of biodegradable esophageal stent can realize the individualized treatment of esophageal stent. And meanwhile, the 3D printing technology can reduce the manufacturing cost of the stent. This review aimed to summarize and discuss the application of esophageal stent, the current research status and prospect of biodegradable esophageal stent and the prospect of 3D printing technology in degradable esophageal stent, hoping to provide evidence and perspectives for the research of biodegradable esophageal stent.

    Release date:2018-01-31 02:46 Export PDF Favorites Scan
  • Treatment of unstable pelvic fractures by cannulated screw internal fixation with the assistance of three-dimensional printing insertion template

    ObjectiveTo evaluate the effectiveness of unstable pelvic fractures treated by cannulated screw internal fixation with the assistance of three-dimensional (3D) printing insertion template.MethodsThe clinical data of 10 patients who underwent surgical treatment for unstable pelvic fractures by cannulated screw internal fixation with the assistance of 3D printing insertion template between May 2015 and June 2016 were retrospectively analysed. There were 7 males and 3 females with an average age of 37.5 years (range, 20-58 years). The causes of injury included falling from height in 5 cases, crushing from heavy load in 1 case, and traffic accidents in 4 cases. The interval from injury to admission was 1-5 hours (mean, 3.1 hours). The fracture situation included 6 cases of sacral fracture, 1 case of right sacroiliac joint dislocation, and 3 cases of iliac bone fracture. There were 10 cases of superior and inferior pubic rami fracture, including 3 cases on the left side (2 cases of suprapubic fracture adjacent to symphysis pubis), 2 cases on the right side, and 5 cases on the bilateral. All fractures were classified according to the Tile system, there were 4 cases of type B2, 1 of type B3, 4 of type C1, and 1 of type C2. The radiological outcome was evaluated by Matta scale, and the positions of the iliosacral screw and superior pubic ramus screw were evaluated according to 3D reconstruction of CT postoperatively. The functional outcome was evaluated by Majeed function scale.ResultsThe average time of each screw implantation was 30 minutes, and the average blood loss per screw incision was 50 mL. The time of implantation of each sacroiliac screw was 24-96 seconds (mean, 62 seconds), and the time of implantation of each suprapubic screw was 42-80 seconds (mean, 63.2 seconds). The hospitalization duration was 17-90 days (mean, 43.7 days). All incisions healed by first intention. All patients were followed up 12-22 months (mean, 15.6 months). The radiological outcome was excellent in 8 cases and good in 2 cases according to Matta scale; and 3D reconstruction of CT demonstrated that all the 9 iliosacral screws were placed as type Ⅰ, and all the 13 suprapubic ramus screws were placed as grade 0 on the first postoperative day. No complication such as neurovascular injury, screw back out or rupture, or secondary fracture displacement was observed during the follow-up. At 6 months after operation, the X-ray films showed good fracture healing in all the 10 patients. The functional outcome was excellent in 9 cases and good in 1 case according to Majeed scale at 1 year after operation. One patient sustained Tile C2 pelvic disruption complicated with L5 nerve root injury achieved complete nervous functional recovery at last follow-up.ConclusionIt has advantages of precise screw insertion and lower risk of neurovascular injury to treat unstable pelvic fractures by cannulated screw internal fixation with the assistance of 3D printing insertion template, which can be a good alternative for the treatment of unstable pelvic fractures.

    Release date:2018-02-07 03:21 Export PDF Favorites Scan
  • Research progress of three-dimensional printing technology for clinical application in intervertebral fusion region

    With the development of three-dimensional (3D) printing technology, more and more researches have focused on its application in the region of intervertebral fusion materials; the prospects are worth looking forward to. This article reviews the researches about 3D printing technology in spinal implants, and summarizes the materials and printing technology applied in the field of spinal interbody fusion, and the shortcomings in the current research and application. With the rapid development of 3D printing technology and new materials, more and more 3D printing spinal interbodies will be developed and used clinically.

    Release date:2018-09-25 02:22 Export PDF Favorites Scan
3 pages Previous 1 2 3 Next

Format

Content