west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Doppler" 50 results
  • COLOR-FLOW DUPLEX DOPPLER SCANNING STUDY IN THE TRAM FLAP PERFORATORS:A REPORT OF 94 CONSECUTIVE PATIENTS

    OBJECTIVE: To investigate the location of transverse rectus abdominis musculocutaneous (TRAM) flap perforators on abdomen skin and the peak systolic flow velocities of the perforators. METHODS: A series of 94 consecutive patient’s TRAM flap perforators were detected by color-flow duplex Doppler scanning peroperatively. Perforator locations were tabulated on the abdomen skin according to their vertical position relative to the umbilicus and their lateral location relative to the abdominal midline. RESULTS: The perforators on both left and right side of TRAM flap were quite not symmetry. The peri-umbilical region contained 81.1% of the perforators. All perforators were detected with peak systolic flow velocities ranging from 5 to 81 cm/s. CONCLUSION: The preoperative color-flow Doppler localization of TRAM flap perforators improves the surgeon’s ability to design the flap in order to capture the dominant vessels, and select single- or double-pedicle and free TRAM flaps based on each patient’s individual characteristics.

    Release date:2016-09-01 10:27 Export PDF Favorites Scan
  • Multiple factor analysis of intraorbital hemodynamic results in diabetic retinopathy

    Objective To determine the affected factors of intraorbital hemodynamic results in diabetic retinopathy (DR) and the risk factors related to the occurrence of DR. Methods Posterior ciliary artery (PCA), central retinal artery (CRA), central retinal vein (CRV), and vortex vein (VV) of 68 patients with DR were measured by color Doppler flow image (CDFI). Thirty-one hemodynamic parameters, including systolic velocity, diastolic velocity, mean velocity, resistive index, pulsatility index and accelerative velocity of ophthalmic artery (OA), and other variates (blood pressure, blood sugar, gender, age, duration of the disease, and so on) were collected and clustered in a principal components analys is following a forward, stepwise logistic regression on these components. Results Nine principal components were extracted from 37 original variates, reflecting the velocity of OA, velocity of PCA, resistance of OA, velocity of CRA,resistance of CRA, resistance of PCA, time-related factor, venous drainage factor and gender factor, respectively. In the result of logistic regression, resistance of OA, velocity of CRA, resistance of PCA, time-related factor, and venous drainage factor were the risk factors related to DR. Conclusion The first risk factor affecting DR is time, and intraorbital hemodynamic abnormity influencing the development of diabetic retinopathy may be the increase of resistance of OA, decrease of velocity of CRA, decrease of resistance of PCA, and increase of venous drainage. (Chin J Ocul Fundus Dis,2004,20:98-100)

    Release date:2016-09-02 05:58 Export PDF Favorites Scan
  • Value of Color Doppler Ultrasonography and Plasma D-imer in Diagnosis of Lower Limb Venous Thrombosis

    Objective To explore the value of color Doppler ultrasonography and plasma D-dimer in diagnosis of lower limb deep venous thrombosis (DVT).Methods The clinical data of 70 cases of patients with lower limb DVT diagnosed clinically were retrospectively studied. The lower limb venous of each patient was examined by color Doppler ultrasonography and the plasma level of D-dimer were measured, furthermore the plasma levels of D-dimer in different phase and different type of thrombosis were compared. Results The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of plasma D-dimer and ultrasonography examination in lower limb DVT were 100%, 66.7%, 97.0%, 100%, and 97.1%, and 98.4%, 83.3%, 98.4%, 83.3%, and 97.1%, respectively. The plasma D-dimer in acute phase 〔(6 451±4 012.22) μg/L〕 and subacute phase 〔(2 063±1831.35) μg/L〕 of lower limb venous thrombosis were significantly higher than that in normal control group 〔(310±66.70) μg/L〕, Plt;0.01 and Plt;0.05, which was not different from that in chronic phase 〔(466±350.52) μg/L〕. Meanwhile, the plasma D-dimer in mixed limb venous thrombosis group 〔(4 464±3 753.16) μg/L〕 and central limb venous thrombosis group 〔(2 149±1 911.53) μg/L〕 were significantly higher than that in control group (Plt;0.05 and Plt;0.01), which was not different from that in peripheral limb venous thrombosis group 〔(560±315.62) μg/L〕. Conclusion Color Doppler ultrasonography is an optimal method and the plasma D-dimer is a predictive index in diagnosis of lower limb DVT.

    Release date:2016-09-08 10:54 Export PDF Favorites Scan
  • Relationship Between The Changes of Hepatic Blood Flow Detected by Using Spectral Doppler Ultrasound and Serum TNF-α and IL-1 β Levels after Liver Ischemia/Reperfusion of Rat

    Objective To discuss the relationship between the changes of hepatic blood flow detected by usingspectral Doppler ultrasound and serum TNF- α and IL-1 β levels after liver ischemia/reperfusion (I/R) of rat. Methods The hepatic ischemia 15 min and reperfusion models were established by using pringle method. The hepatic blood flow of hepatic artery and portal vein at 1, 6, and 24 hours after liver I/R were detected by using spectral Doppler ultrasound, the total blood flow volume (FV) was calculated, and the serum TNF- α and IL-1 β levels at each time point were detected. The correlation between the TNF-α, IL-1 β, and FV were analyzed. Results The FV at 1 hour and 6 hours after reperfusion in I/R group were less than those in sham operation (SO) group 〔(52.08±11.88) mL/min vs. (85.32±29.85) mL/min and (44.69±8.75)mL/min vs. (81.41±28.67) mL/min, P<0.05〕. The FV at 24 hours after operation or reperfusion of 2 groups was no significant differences (P>0.05). The serum content of TNF-α at 1 hour after reperfusion in I/R group was higher than that in SO group 〔(310.52±39.83)pg/mL vs. (240.74±31.65)pg/mL, P<0.05〕. The serum contents of TNF-α at 6 and 24 hours after operation or reperfusion of 2 groups were no significant differences (P>0.05). The serum contents of IL-1β at 1 hour and 6 hours in I/R group were higher than those in SO group 〔(38.08±3.73) pg/mLvs. (22.03±0.79) pg/mL and (27.44±6.11) pg/mL vs. (21.78±0.71) pg/mL, P<0.05〕. The serum content of IL-1β at 24 hours after operation or reperfusion of 2 groups was no significant differences (P>0.05). There was a negative correlation between the FV and TNF-α or IL-1β (r=-0.43, P<0.05;r=-0.46, P<0.05). Conclusions Spectral Doppler ultrasound can observe the changes of hepatic blood flow and evaluate the hepatic microcirculation indirectly. The hepatic blood flow after liver I/R decreases and it may be related to over expression of TNF-α and IL-1β.

    Release date:2016-09-08 10:35 Export PDF Favorites Scan
  • EXPERIMENTAL STUDY OF THE MECHANISM ON BLOOD SUPPLY TO DELAYED SEPARATED SKIN FLAP BY ULTRASONIC DOPPLER

    In order to investigate the mechanism of blood supply to the delayed separated skin flap and the time and criteria for its transfer, 5 smallsized Banna pigs were selected to produce 14 skin flaps. In the experimental group the skin flap on one side was made from the middle of the back having an extrathin steel sheet intervened between the flap and the soft tissue of the back whereas the flap on the opposite side without a steel sheet intervened was served as the selfcontrol. The skin flaps were examined 3,7,10 and 20 days after the operation and 3,7 and 10 days after transfer, respectively, by (1) gross observation; (2) ultrasonic Doppler; (3) superficial skin temperature measurement and; (4) histomorphological examination. In the experimentalgroup the survival rate of the flap was 100 percent whereas in the control group all of the flaps had necrosis from 30 to 50 percent after the flap being transfered. In the experimental group, the echo sound from the arterial blood flow from ultrasonic Doppler was heard at the pedicle 7 days after the operation, and as time elapsed, the echo sound spread distally, whereas in the controls no echo sound could be heard over the skin flap. There was significant difference statistically between the experimental and control groups in the temperature of the flaps while the flaps were being transferred (P lt; 0.01). The external diameters of the blood vessels in the central area of the skin flap were larger in the experimental group, 0.8 to l.2mm in comparison to 0.4mm.

    Release date:2016-09-01 11:08 Export PDF Favorites Scan
  • Study on Downstream Flow Field Uniformity of Aortic Stenosis by Using Pulse Wave Doppler Echocardiography

    ObjectiveBy comparing the difference between different stenosed degree of aortic valve in flow field uniformity and turbulent shear stress (TSS), to explore the relation between flow field uniformity and different stenosed degree of aortic valve, and probe the clinical value for deciding the operation timing, and analyze the possible role of TSS in the progress of the disease.MethodsThe flow field uniformity values and TSS in parasternal long axis plane and apical five cavity plane on each point were measured and calculated by pulse wave Doppler echocardiography technique for 33 patients with different stenosed degree of aortic valve.ResultsThere were significant difference between the different stenosed degree of aortic valve in maximal velocity difference(ΔV max )and TSS( P lt;0.05, 0.01). The more severe the aortic stenosis was, the worse the flow field uniformity was, the lower the TSS was.ConclusionsThere are significant difference between the patients of different stenosed degree of aortic valve in flow field uniformity. Flow field uniformity has important value in classifying the degree of aortic stenosis and deciding the timing of operation. The more severe the aortic stenosis is ,the lower TSS is. It can be thought that low TSS distribution has important role in pathological process of constriction in cardiovascular system diseases.

    Release date:2016-08-30 06:24 Export PDF Favorites Scan
  • Measurement of ocular hemodynamics in retinal vein occlusion using color Doppler imaging

    Objective To investigate the changes of ocular hemodynamics in patients with retinal vein occlussion(RVO). Methods The hemodynamic parameters(PSV,EDV,PI,Vmax)of central retinal artery(CRA)and central retinal vein(CRV)were measured in the involved eyes(n=48) with RVO and the contralateral clinically healthy eyes(n=39) and in the control eyes(n=40) by color Doppler imaging (CDI)(ATLHDI3000). Results Peak systolic velocity (PSV) and end diastolic velocity (EDV) were significantly lower in the CRA of involved eyes and clinically healthy eyes of patients with RVO compared with control eyes,and pulsatility index(PI)was significantly higher in the CRA of involved eyes of patients with RVO compared with control eyes.PSV were significantly lower in the CRA of involved eyes of patients with RVO compared with their clinically healthy eyes.Pulsatility index(PI)was significantly higher in the CRA of involved eyes of patients with RVO compared with their clinically healthy eyes.Maximun vein velocity (Vmax) was significantly lower in the CRV of involved eyes and clinically healthy eyes of patients with RVO compared with control eyes. Conclusion The changes of hemodynamics in CRA,CRV of involved eyes of patients with RVO may invade their clinically healthy eyes.CDI may be helpful to early diagnosis for RVO. (Chin J Ocul Fundus Dis,1998,14:111-113)

    Release date:2016-09-02 06:11 Export PDF Favorites Scan
  • CONTROL STUDY OF INFRA-RED LIGHT SCANNING AND COLORED ULTRASONIC DOPPLER IN DIAGNOSIS OF BREAST MASSES

    【Abstract】Objective To estimate the value of the infra-red light scanning and the colored ultrasonic Doppler in diagnosis of breast masses. Methods Two hundred and seventy nine patients with breast mass were examined with the infrared light scanning and the colored ultrasonic Doppler in our hospital.Following the two examinations the masses were resected and pathologically examined as a control. Results The conformity of the infra-red light scanning with pathologic diagnosis was 94.0% in 182 hyperplasia masses, while that of the ultrasonic Doppler was 84.6%(P<0.01). The conformity of the infra-red light scanning with pathology was 91.7% and that of the colored ultrasonic Doppler was 83.3%(Pgt;0.05). The colored ultrasonic Doppler was seemingly more effective than infrared light scanning in diagnosing 9 galactocele and 5 intraductal papilloma, but there is no significant difference(Pgt;0.05). The conformity of the two exams with pathology in 59 fibroadenoma was almost the same.Conclusion The infra-red light scanning is more effective than the colored ultrasonic Doppler in diagnosing the hyperplasia masses, there is no significant difference in diagnosing the breast cancer and the fibroadenoma between the two exams. Combined use of this two exams would increase the accurase of the breast masses.

    Release date:2016-08-28 05:30 Export PDF Favorites Scan
  • A prospective study of super-thin anterolateral thigh flap harvesting assisted by high-frequency color Doppler ultrasound in detecting perforators in deep adipose layers

    Objective To investigate the clinical application of high-frequency color Doppler ultrasound (HFCDU) in detecting perforators in the deep adipose layers for harvesting super-thin anterolateral thigh flap (ALTF). Methods Between August 2019 and January 2023, 45 patients (46 sides) with skin and soft tissue defects in the foot and ankle were treated, including 29 males and 16 females, aged from 22 to 62 years, with an average of 46.7 years. The body mass index ranged from 19.6 to 36.2 kg/m2, with an average of 23.62 kg/m2. The causes of injury included traffic accident injury in 15 cases, heavy object crush injury in 20 cases, mechanical injury in 8 cases, heat crush injury in 1 case, and chronic infection in 1 case. There were 20 cases on the left side, 24 cases on the right side, and 1 case on both sides. After thorough debridement, the wound size ranged from 5 cm×4 cm to 17 cm×11 cm. All patients underwent free super-thin ALTF transplantation repair. HFCDU was used to detect the location of the perforators piercing the deep and superficial fascia, as well as the direction and branches of the perforators within the deep adipose layers before operation. According to the preoperative HFCDU findings, the dimensions of the super-thin ALTF ranged from 6 cm×4 cm to 18 cm×12 cm. The donor sites of the flaps were directly sutured. Results A total of 55 perforators were detected by HFCDU before operation, but 1 was not found during operation. During operation, a total of 56 perforators were found, and 2 perforators were not detected by HFCDU. The positive predictive value of HFCDU for identifying perforator vessels was 98.2%, and the sensitivity was 96.4%. Among the 54 perforators accurately located by HFCDU, the orientation of the perforators in the deep adipose layers was confirmed during operation. There were 21 perforators (38.9%) traveled laterally and inferiorly, 12 (22.2%) traveled medially and inferiorly, 14 (25.9%) traveled laterally and superiorly, 5 (9.3%) traveled medially and superiorly, and 2 (3.7%) ran almost vertically to the body surface. Among the 54 perforators accurately located by HFCDU, 35 were identified as type 1 perforators and 12 as type 2 perforators (HFCDU misidentified 7 type 2 perforators as type 1 perforators). The sensitivity of HFCDU in identifying type 1 perforators was 100%, with a positive predictive value of 83.3%. For type 2 perforators, the sensitivity was 63.2%, and the positive predictive value was 100%. The surgeries were successfully completed. The super-thin ALTF had a thickness ranging from 2 to 6 mm, with an average of 3.56 mm. All super-thin ALTF survived, however, 1 flap experienced a venous crisis at 1 day after operation, but it survived after emergency exploration and re-anastomosis of the veins; 1 flap developed venous crisis at 3 days after operation but survived after bleeding with several small incisions; 3 flaps had necrosis at the distal edge of the epidermis, which healed after undergoing dressing changes. All 45 patients were followed up 6-18 months (mean, 13.6 months). Three flaps required secondary defatting procedures, while the rest had the appropriate thickness, and the overall appearance was satisfactory. Conclusion Preoperative application of HFCDU to detect the perforator in the deep adipose layers can improve the success and safety of the procedure by facilitating the harvest of super-thin ALTF.

    Release date:2024-01-12 10:19 Export PDF Favorites Scan
  • Tissue Doppler Strain Rate Imaging to Evaluate the Impact of Dopamine and Milrinone on Left Ventricular Function of Patients Undergoing Heart Valve Replacement

    Abstract: Objective To use tissue Doppler strain rate imaging to evaluate the impact of low dose dopamine and milrinone on systolic and diastolic function of the left ventricle of patients undergoing heart valve replacement. Methods  Forty patients undergoing selective heart valve replacement in West China Hospital of Sichuan University between March and May 2011 were included in this study. All the patients were randomized into 2 groups with 20 patients in each group: milrione group and dopamine group. After anesthesia induction and before cardiopulmonary bypass setup, left ventricular ejection fraction (LVEF) was measured by echocardiography. Tissue Doppler strain rate imaging was used to measure the left ventricular lateral wall and midventricular segment from the four-chamber view, which was compared with Doppler parameters. Results LVEF, ratio of early-diastolic to end-diastolic velocity (E/A) of transmitral flow, ratio of mitral  inflow velocity to early diastolic velocity in the annulus (E/Et) of both 2 groups were significantly different between before and after dopamine and milrinone administration (P<0. 05). In the milrinone group, 4 segments systolic peak velocity (Vs), 1 segment early diastolic peak velocity (Ve), 4 segments late diastolic peak velocity (Va), 3 segments Ve/Va ratio, 2 segments systolic peak strain rate (SRs), 2 segments late diastolic peak strain rate (SRa), and 3 segments early diastolic peak strain rate SRe/SRa ratio after dopamine and milrinone administration were significantly higher than those before dopamine  and milrinone administration (P<0. 05). In the dopamine group, 4 segments systolic peak velocity (Vs), 1 segment Ve, 4 segments Va, 1 segment Ve/Va ratio, 2 segments SRs, 1 segment SRe, 1 segment SRa, and 1 segment SRe/SRa ratio after dopamine and milrinone administration were significantly higher than those before dopamine and milrinone administration (P<0.05). To compare the milrione group and dopamine group after medication administration, 2 segments Vs, 4 segments Va, 1 segment SRe, 1 segment SRa, 2 segments Ve/Va ratio, and 2 segments SRe/SRa ratio of the milrione group were significantly higher than those of the dopamine group (P<0.05), and 1 segment Vs, two segments SRs of the milrione group were significantly lower than those of the dopamine group (P<0.05). Conclusion Both milrinone and dopamine can improve left ventricular systolic function of perioperative patients undergoing heart valve replacement assessed by tissue Doppler strain rate imaging, while milrinone can improve the diastolic function of the left ventricle on the long axis more significantly.

    Release date:2016-08-30 05:28 Export PDF Favorites Scan
5 pages Previous 1 2 3 4 5 Next

Format

Content