OBJECTIVE: To investigate the location of transverse rectus abdominis musculocutaneous (TRAM) flap perforators on abdomen skin and the peak systolic flow velocities of the perforators. METHODS: A series of 94 consecutive patient’s TRAM flap perforators were detected by color-flow duplex Doppler scanning peroperatively. Perforator locations were tabulated on the abdomen skin according to their vertical position relative to the umbilicus and their lateral location relative to the abdominal midline. RESULTS: The perforators on both left and right side of TRAM flap were quite not symmetry. The peri-umbilical region contained 81.1% of the perforators. All perforators were detected with peak systolic flow velocities ranging from 5 to 81 cm/s. CONCLUSION: The preoperative color-flow Doppler localization of TRAM flap perforators improves the surgeon’s ability to design the flap in order to capture the dominant vessels, and select single- or double-pedicle and free TRAM flaps based on each patient’s individual characteristics.
Objective To determine the affected factors of intraorbital hemodynamic results in diabetic retinopathy (DR) and the risk factors related to the occurrence of DR. Methods Posterior ciliary artery (PCA), central retinal artery (CRA), central retinal vein (CRV), and vortex vein (VV) of 68 patients with DR were measured by color Doppler flow image (CDFI). Thirty-one hemodynamic parameters, including systolic velocity, diastolic velocity, mean velocity, resistive index, pulsatility index and accelerative velocity of ophthalmic artery (OA), and other variates (blood pressure, blood sugar, gender, age, duration of the disease, and so on) were collected and clustered in a principal components analys is following a forward, stepwise logistic regression on these components. Results Nine principal components were extracted from 37 original variates, reflecting the velocity of OA, velocity of PCA, resistance of OA, velocity of CRA,resistance of CRA, resistance of PCA, time-related factor, venous drainage factor and gender factor, respectively. In the result of logistic regression, resistance of OA, velocity of CRA, resistance of PCA, time-related factor, and venous drainage factor were the risk factors related to DR. Conclusion The first risk factor affecting DR is time, and intraorbital hemodynamic abnormity influencing the development of diabetic retinopathy may be the increase of resistance of OA, decrease of velocity of CRA, decrease of resistance of PCA, and increase of venous drainage. (Chin J Ocul Fundus Dis,2004,20:98-100)
Objective To explore the value of color Doppler ultrasonography and plasma D-dimer in diagnosis of lower limb deep venous thrombosis (DVT).Methods The clinical data of 70 cases of patients with lower limb DVT diagnosed clinically were retrospectively studied. The lower limb venous of each patient was examined by color Doppler ultrasonography and the plasma level of D-dimer were measured, furthermore the plasma levels of D-dimer in different phase and different type of thrombosis were compared. Results The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of plasma D-dimer and ultrasonography examination in lower limb DVT were 100%, 66.7%, 97.0%, 100%, and 97.1%, and 98.4%, 83.3%, 98.4%, 83.3%, and 97.1%, respectively. The plasma D-dimer in acute phase 〔(6 451±4 012.22) μg/L〕 and subacute phase 〔(2 063±1831.35) μg/L〕 of lower limb venous thrombosis were significantly higher than that in normal control group 〔(310±66.70) μg/L〕, Plt;0.01 and Plt;0.05, which was not different from that in chronic phase 〔(466±350.52) μg/L〕. Meanwhile, the plasma D-dimer in mixed limb venous thrombosis group 〔(4 464±3 753.16) μg/L〕 and central limb venous thrombosis group 〔(2 149±1 911.53) μg/L〕 were significantly higher than that in control group (Plt;0.05 and Plt;0.01), which was not different from that in peripheral limb venous thrombosis group 〔(560±315.62) μg/L〕. Conclusion Color Doppler ultrasonography is an optimal method and the plasma D-dimer is a predictive index in diagnosis of lower limb DVT.
Objective To investigate a method of improving design of the skin flap pedicled with descending branch of lateral femoral circumflex artery, in order to increase the accuracy of preoperative Doppler location. Methods Firstly, the interspace between rectus femoris and vastus lateralis was regarded as line A, and the point of intersection between line A and the vertical line through the midpoint of the line between anterior superior iliac spine and lateral margin of patella was point A. And then the line between the midpoint of groin and point A was regarded as line B. Based on this , the perforating point of cutaneous branch could be located by Doppler along the line B. From November 2001 to October 2004, this method was used in 38 skin flaps of 37 cases, being all males and 16-48 years old. The area of the flap ranged from 7 cm×6 cm to 24 cm×16 cm. Results All the perforatingpoint of cutaneous branch were located outward the line A. The rate that the preoperative Doppler location was consistent with the utility point of formatting skin flap was 97.4%. All the cases were followed up postoperatively 1-20 months. Among the cases, 36 skin flaps of 35 cases was successful and only 2 skin flaps partially necrosed, which healed after changing dressings or skin graft.Out of 35 cases, the sensation restoration of the skin flap was S2-S3 in 6 cases owing to the anastomosis of lateral femoral cutaneous nerve and a skin nerve of the recipient site, while that of the other cases was S0-S1. Conclusion Preoperative Doppler location and improving design of lineB can be a useful instruction for the design of skin flap pedicled with descending branch of lateral femoral circumflex artery.
Objective To discuss the relationship between the changes of hepatic blood flow detected by usingspectral Doppler ultrasound and serum TNF- α and IL-1 β levels after liver ischemia/reperfusion (I/R) of rat. Methods The hepatic ischemia 15 min and reperfusion models were established by using pringle method. The hepatic blood flow of hepatic artery and portal vein at 1, 6, and 24 hours after liver I/R were detected by using spectral Doppler ultrasound, the total blood flow volume (FV) was calculated, and the serum TNF- α and IL-1 β levels at each time point were detected. The correlation between the TNF-α, IL-1 β, and FV were analyzed. Results The FV at 1 hour and 6 hours after reperfusion in I/R group were less than those in sham operation (SO) group 〔(52.08±11.88) mL/min vs. (85.32±29.85) mL/min and (44.69±8.75)mL/min vs. (81.41±28.67) mL/min, P<0.05〕. The FV at 24 hours after operation or reperfusion of 2 groups was no significant differences (P>0.05). The serum content of TNF-α at 1 hour after reperfusion in I/R group was higher than that in SO group 〔(310.52±39.83)pg/mL vs. (240.74±31.65)pg/mL, P<0.05〕. The serum contents of TNF-α at 6 and 24 hours after operation or reperfusion of 2 groups were no significant differences (P>0.05). The serum contents of IL-1β at 1 hour and 6 hours in I/R group were higher than those in SO group 〔(38.08±3.73) pg/mLvs. (22.03±0.79) pg/mL and (27.44±6.11) pg/mL vs. (21.78±0.71) pg/mL, P<0.05〕. The serum content of IL-1β at 24 hours after operation or reperfusion of 2 groups was no significant differences (P>0.05). There was a negative correlation between the FV and TNF-α or IL-1β (r=-0.43, P<0.05;r=-0.46, P<0.05). Conclusions Spectral Doppler ultrasound can observe the changes of hepatic blood flow and evaluate the hepatic microcirculation indirectly. The hepatic blood flow after liver I/R decreases and it may be related to over expression of TNF-α and IL-1β.
Objective To investigate the effectiveness of high frequency color Doppler ultrasound for detecting perforators in the anterolateral thigh (ALT) flap surgery. Methods Between February 2011 and July 2012, 8 patients underwent high frequency color Doppler ultrasound to detect the perforator anatomy before ALT flap surgery. There were 5 males and 3 females, aged 21-46 years (mean, 34 years). Defects were caused by excision of squamous cell carcinoma in 2 cases, by scalp avulsion in 2 cases, by soft tissue necrosis after neck trauma in 1 case, by excision of groin fibrosarcoma in 1 case, by excision of groin melanoma in 1 case, and by malformation of the face in 1 case. The defect size varied from 12 cm × 7 cm to 22 cm × 18 cm. The perforator with wider caliber, faster flow speed, and shorter intramuscular trajectory was selected, and the flap was designed according to the observed results, which size varied from 14 cm × 9 cm to 25 cm × 20 cm. The donnor sites were repaired by free skin graft. Results Totally, 19 perforators in the flap area were detected by high frequency color Doppler ultrasound, and 18 were identified during operation, with an accuracy rate of 94.7%. The point going out muscle, the travel and direction of perforators observed during operation were basically in accordance with those detected by high frequency color Doppler ultrasound. The other flaps survived, and obtained healing by first intention except 1 flap which had partial fat necrosis with healing by second intention. The skin graft at donor site survived. All patients followed up 4-16 months (mean, 8 months). The flaps had good color and texture. Conclusion High frequency color Doppler ultrasound is a valuable imaging modality for the preoperative assessment of the vascular supply for ALT flap.
In order to investigate the mechanism of blood supply to the delayed separated skin flap and the time and criteria for its transfer, 5 smallsized Banna pigs were selected to produce 14 skin flaps. In the experimental group the skin flap on one side was made from the middle of the back having an extrathin steel sheet intervened between the flap and the soft tissue of the back whereas the flap on the opposite side without a steel sheet intervened was served as the selfcontrol. The skin flaps were examined 3,7,10 and 20 days after the operation and 3,7 and 10 days after transfer, respectively, by (1) gross observation; (2) ultrasonic Doppler; (3) superficial skin temperature measurement and; (4) histomorphological examination. In the experimentalgroup the survival rate of the flap was 100 percent whereas in the control group all of the flaps had necrosis from 30 to 50 percent after the flap being transfered. In the experimental group, the echo sound from the arterial blood flow from ultrasonic Doppler was heard at the pedicle 7 days after the operation, and as time elapsed, the echo sound spread distally, whereas in the controls no echo sound could be heard over the skin flap. There was significant difference statistically between the experimental and control groups in the temperature of the flaps while the flaps were being transferred (P lt; 0.01). The external diameters of the blood vessels in the central area of the skin flap were larger in the experimental group, 0.8 to l.2mm in comparison to 0.4mm.
Objective To observe the ultrasonographic features of idiopathic uveal effusion syndrome (IUES). MethodsA retrospective controlled study. From January 2012 to December 2023, 13 patients with IUES (26 eyes) diagnosed by ophthalmology examination in Department of Ophthalmonogy of Beijing Tongren Hospital (IUES group) and 22 healthy people with 30 eyes (control group) were included in the study. Both eyes of all participants were examined by color Doppler ultrasound (CDU) and ultrasonic biomicroscopy (UBM). The thickness of the ocular wall at 300 μm on the temporal side of the optic disc was measured by CDU. UBM was used to measure the thickness of the nasal and temporal scleral processes. Corneal thickness (CT), anterior chamber depth (AD), lens thickness (LT) and axial length (AL) were measured by A-mode ultrasound. There were no significant differences in age (t=0.842), sex component ratio (χ2=0.540), eye difference (χ2=0.108) and AL (t=0.831) between IUES group and control group (P>0.05). The CDU and UBM imaging features and biometrics of IUES affected eyes were observed. Independent sample t test was used for comparison between groups. ResultsCDU examination results showed that in 26 eyes of IUES group, choroidal detachment occurred in 20 eyes (76.9%, 20/26), which showed arc-shaped band echo connected with peripheral and equatorial eye wall echo, with uniform low echo area below, and blood flow signal could be seen on the band echo. The echo thickened and decreased in 4 eyes (15.3%, 4/26). Nine eyes (33.3%, 9/26) were accompanied by retinal detachment, which showed that the posterior pole vitreous echo was connected to the optic disc echo, and the blood flow signal was seen on the ribbon echo. UBM results showed ciliary detachment in 22 eyes (84.7%, 22/26), showing a spongy thickening of the ciliary body with interlamellar echo separation and an echoless area between the sclera. Ciliary body echo thickened and decreased in 2 eyes (7.7%, 2/26). Shallow space between ciliary body and sclera was observed in 2 eyes (7.7%, 2/26). Compared with the control group, CT (Z=2.054), LT (Z=1.867), scleral thickness (Z=2.536) and ocular wall thickness (Z=2.094) were thickened in IUES group, and AD (Z=1.888) were decreased, with statistical significance (P<0.05). ConclusionsThe CDU of IUES is characterized by a thickened echo of the ocular wall and a uniform low echo area under the detached choroid. UBM is characterized by a spongy thickening of the ciliary body echo with interlaminar echo separation.
Objective To investigate theory guidance for preoperative appraisal of advanced stage lower limb arteriosclerosis obliterans and clinical application of arteriae surales. Methods From September 2007 to June 2008, one hundred cases without obviously arteriosclerosis were collected to accepted color Doppler ultrasonography, and parameters of the arteriae surales were observed, such as location, macro-body morphous, caliber, and blood parameters value, meanwhile the caliber and blood parameters value of anterior tibial artery and posterior tibial artery were also measured. Results Detection rate of arteriae surales was 96% (96/100). Arteriae surales located midpiece sequentiae of popliteal fossa, and above flatfish tendinous arch, which in 89 cases were geminous branched from popliteal artery; in the remaining 7 cases, popliteal artery diverged a bole, walked 1-3 cm, then diverged two branches and ingressed gastrocnemius. Diameter and cross section area of arteriae surales were smaller than those of anterior tibial artery and posterior tibial artery (P<0.05), but peak flow rate of systolic phase, maximum positive direction flow rate of relaxing period and mean flow rate were not significantly differents between arteriae surales and anterior tibial artery or posterior tibial artery (P>0.05). The flow of geminous arteriae surales was 63.1% of anterior tibial artery, and 59.1% of posterior tibial artery. Conclusion Through the ultrasonic study, it is significant for clinical therapy to master the normal anatomy, blood parameters value and flow of arteriae surales.
ObjectiveTo evaluate liver perfusion in pregnant women with hepatitis between 13 and 41 weeks of gestation by three-dimensional color power Doppler angiography (3D-CPA) vascular indexes. MethodsThis study involved 73 pregnant women with hepatitis and 44 healthy pregnant women who had the pregnancy examination between February 2012 and June 2013. We sampled in the area which was near the right lobe of the pregnant women liver's portal vein branch, and obtained the vascularization index (VI), flow index (FI) and vascularization flow index (VFI) via the virtual organ computer-aided analysis (VOCAL) method. Then, we compared the liver perfusion differences between the pregnant women with hepatitis and healthy pregnant women. ResultsThe hepatic flow indexes obtained by 3D-CPA were significantly different between the HBV-DNA viral load and the control groups. The cutoff values of the three vascular indexes of patients with hepatitis with HBV-DNA viral load and the healthy pregnant women were respectively VI=8.760 (P<3×10-4); FI=22.180 (P<6×10-7); and VFI=1.575 (P<3×10-5). ConclusionApplication of the 3D-CPA on liver perfusion may differentiate pregnant women with hepatitis B from normal ones, thus offer a support for clinical prevention and treatment for pregnant women with hepatitis B.