Objective To study the advances in clinical application of hernioplasty by high molecular material. Methods The literature in the recent years on the advances of hernioplasty by high molecular material was reviewed. Results At present time many operative techniques of hernioplasty by high molecular material have been developed. The representative techniques were ①Rives-Stoppa′s mesh inlay hernioplasty; ②Lichtenstein′s tesion-free herniorrhaphy; ③mesh plug hernioplasty; ④Gilbert′s sutureless hernioplasty; ⑤laparoscopic inguinal hernioplasty. The reparing high molecular material was divided into absorbable and unabsorbable material, the former included polyglycolic-acid and polyglaction, the later consists of polypropylene polyester and expanded polytetrafluoroethylene.Conclusion The clinical application of henioplasty by high molecular material is increasing. According to the hernia type and patient condition, excellent outcome will be achieved by the application of proper repairing method and repair material.
Objective To prepare a new sirolimus drug-coated polypropylene (SRL-PP) mesh by grafting he sirolimus onto the surface of the polypropylene (PP) mesh via chemical reaction, and to apply the new mesh to animal experiment to explore its anti-adhesion properties.MethodsThe sirolimus was grafted onto the surface of the mesh by chemical reaction to prepare the SRL-PP mesh, which was compared with the PP mesh and the polyethylene glycol modified polypropylene (PEG-PP) mesh. The three groups of meshes were respectively characterized (infrared spectroscopy test, contact angle measurement), and their tensile property was measured. These meshes were implanted into the abdominal cavity of the rats respectively. The anti-adhesion properties of the new sirolimus drug-coated mesh was studied by intraperitoneal adhesion and histopathological change in rats.ResultsThe results of infrared spectrum analysis showed that there was a new absorption peak at the wavelength 1 643 cm–1 (amide group) of SRL-PP mesh, suggesting that sirolimus drug was successfully uploaded onto the surface of the mesh; the SRL-PP mesh was excellent in hydrophilicity, which provided a favorable condition for the growth of peritoneal mesothelial cells. There was no significant difference in mechanical properties between SRL-PP mesh and PP mesh or PEG-PP mesh, which provided a good mechanical guarantee for clinical application. The degree of abdominal adhesion in SRL-PP mesh group (1.00±0.58) was significantly lower than that in PP mesh group (5.17±0.69) and PEG-PP mesh group (4.00±0.58), and the tD value between SRL-PP mesh group and PP mesh group was 2.76 (P<0.05). The number of inflammatory cells and the expression of inflammatory cytokines in the adhesion tissue in SRL-PP mesh group were significantly lower than those in PP mesh group and PEG-PP mesh group.ConclusionsThe sirolimus is successfully loaded onto the surface in the PP mesh by chemical reaction. Animal experiment shows that the sirolimus drug-coated mesh can significantly reduce the abdominal adhesion of the rats, which provides a basis for clinical trial and application.
ObjectiveTo observe the effects and security of dexmedetomidine in combined spinal epidural anesthesia (CSEA) for laparoscopic total extraperitoneal hernia repair (TEP). MethodsFrom January 2010 to January 2013, we selected 90 patients who were going to receive TEP surgery as our study subjects. The patients were divided into three groups:M1, M2 and M3 with 30 patients in each. The patients had left lateral position, and anesthesia was done between 3-4 lumbar epidural line. Injection of 0.5% bupivacaine 2 mL was carried out, and epidural catheter was 3-5 cm. Anesthesia plane was adjusted from the chest 4 or 6 vertebra to the sacral vertebra. The three groups of patients were treated with micro pump using dexmedetomidine given at a pre-charge of 0.5 μg/kg, and then group M1 was maintained by 0.3 μg/(kg·h), M2 by 0.5 μg/(kg·h), and M3 by 0.7 μg/(kg·h). The changes of mean arterial pressure (MAP), heart rate, respiration and pulse oximetry (SpO2) were observed at each time point, and bispectral index (BIS) monitor and Ramsay sedation score test were also conducted. ResultsThe changes of MAP, heart rate and respiration in group M1 were not obvious; the Ramsay score for group M1 was 2 to 3, and BIS value after pre-charge was 65-84. For group M2, MAP, heart rate and respiration had a slight decline; Ramsay score was 3-5 points, and BIS value was 60-79. In group M3, patients had a milder decline in their MAP and respiration; the heart rate declined obviously after receiving dexmedetomidine and one patient with severe decline of the heart rate alleviated after active treatment; Ramsay score was 5 to 6 points, and BIS value was between 55 and 75. There was little change in SpO2 in all the three groups, and the difference was not statistically significant (P>0.05). ConclusionContinuous injection of dexmedetomidine at 0.3-0.5 μg/(kg·h) in CSEA is an alternative way for anesthesia, which can effectively promote sedation and reduce pain and discomfort.
ObjectiveTo investigate the clinical value of veress needle with thread for laparoscopic high ligation of hernia sac in children. MethodsThe clinical data of 56 cases of pediatric inguinal hernia using laparoscopic high ligation of hernia sac with veress needle from May 2013 to May 2014 were analyzed retrospectively. ResultsAll patients were successfully carried out operation by laparoscopic high ligation of hernia sac.Forty-one cases underwent unilateral surgery, and operative time was 6-18 min (mean 9.6 min); 15 cases underwent bilateral surgery, and operative time was 10-32 min (mean 14.3 min).Nine cases of contralateral recessive hernia were found and ligated during operation.There was no complications, such as scrotal edema, scrotal gas or incision infection after operation, and all patients were discharged in l-2 days after operation.No recurrence or testicular dysplasia was found during 3 to 15 months (mean 10.8 months) follow-up. ConclusionsThere are many advantages in laparoscopic high ligation of hernia sac with veress needle, such as less damage, hidden incision, faster recovery, shorter hospital stay, simple operation, and better efficacy.We can find contralateral recessive hernia during operation and avoid second surgery with high clinical value, therefore it is worthy of clinical application.
Objective To explore the operative result of intrarectal proctoptosis accompanying hernia of pelvic floor due to common outlet obstructive constipation(OOC).MethodsEleven cases of intrarectal proctoptosis with of pelvic floor surgically treated were analysed. Results In a week following operation, 9 of 11 patients’ symptoms disappeared, the other 2 cases recovered after 3 months, functional exercise. Conclusion Functional rectal suspension combined with repair of pelvic, partial sigmoidectomy, surgical elevation of pelvic floor and hysteropexy are highly effective in alleviating symptoms in patients with intrarectal proctoptosis accompanying pelvic floor herniation.
【Abstract】Objective To investigate the effects and advantages of laparoscopic hernioplasty for hernia. Methods From June 1995 to June 2005, 222 patients with hernia were treated with laparoscopy. Transabdominal preperitoneal hernia repair (TAPP) were performed in 166 patients. Totally extraperitoneal hernia repair(TEP) were performed in 25 patients. Closure of the internal orifice of hernia was performed in 21 patients. Furthermore, incisional hernia in 2 patients, diaphragmatic hernia in 1 patient and mesenteric hernia in 1 patient were performed by laparoscopic hernioplasty and 6 patients with hernia of oesophagus finestra performed hernioplasty combined collapse gastric fundus with laparoscopy. In this series 45 patients associated with other abdominal disease were simultaneously treated with laparoscopy. Results All cases were operated successfully. The span of operation reduration was 42.5 min 〔(10~180 min)〕. The average length of postoperative hospital stay were 4.6 days. There was one early failure owing to the use of too small a piece of mesh.Conclusion The results indicate that mesh repair of hernias is a satisfactory technique with a low recurrence rate and a low major complication rate.
Objective To investigate the application of transverse fascia in inguinal hernia repair. Methods In this study, 617 patients underwent inguinal hernia repair between January 1990 and December 2005 in our hospital were included, which were divided into two groups according to different operative ways: transverse fascia method group (n=337) and Bassini method group (n=280). Then intraoperative results, postoperative complications, and rehabilitated results of patients in two groups were compared. Results Compared with Bassini method group, the patients in transverse fascia method group did not show significant difference in operative time and blood loss during operation (Pgt;0.05). The differences of severe postoperative pain, testicular swelling, the time of the body’s restore for normal activities, and recurrence rate of patients between two groups were significant (Plt;0.05), while the difference of hematoma of scrotum and infection of incisional wound (Pgt;0.05). Conclusion The strengthening of posterior wall by transverse fascia and reconstruction of inner ring is a simple and effective method for inguinal hernia repair.
To summarize the therapeutic method and effectiveness of parastomal hernia repair in situ with sublay methods. Methods Between February 2003 and May 2009, 34 patients with parastoma hernia were treated with Sublay methods using primary midl ine incision approach and polypropylene patch. There were 23 males and 11 females withan average age of 58.4 years (range, 43-78 years). The disease duration was 1 to 17 years (mean, 4.7 years). Of 34 patients, 6 had recurrent parastoma hernia. The diameter of hernia ring was 5-12 cm (mean, 7.2 cm). Results Sublay technique repair was successfully performed in all patients. The operative time was 96-160 minutes (mean, 116 minutes). The gastric tube was pulled out 12 hours to 5 days (mean, 3 days) after operation. The drainage tube was taken out at 2-7 days (mean, 4 days) after operation. The postoperative hospital ization time was 7 to 15 days (mean, 9 days). And the incisions of 32 patients healed by first intention. Incisional fat l iquefaction occurred in 1 case and infection in 1 case, and their incisions healed after dressing change. Seroma at the upper of the patch occurred in 7 patients and was cured by 2 to 3 times of percutaneous puncture and local pressure. Thirty-two patients were followed up 6-75 months (mean, 32 months). No chronic pain, lumping sensation, or local expansion in wound area occurred. Two recurrences occurred 3 months and 7 months after operation, respectively, and patients restored after expectant treatment or re-operation. Conclusion The in situ Sublay methods using primary midl ine incision approach and nonabsorbable patch is a feasible and safe method for parastomal hernia repair.
Objective To explore surgical technique and clinical outcome of transabdominal preperitoneal hernia repair (TAPP) and totally extraperitoneal hernia repair (TEP) in inguinal hernia repair. Methods 〗The clinical data of 23 patients underwent laparoscopic herniorrhaphy were retrospectively analyzed. Nine patients were underwent TAPP, and 14 patients underwent TEP. Results 〗None of patients was changed to open operation. Only one patient of TEP was changed to TAPP. Average operative time was (82.1±40.6) min. Blood loss was (5.7±3.0) ml. Disruption of peritoneum happened to 2 patients underwent TEP. The rate of postoperative complications was 21.7% (5/23), which included serum swelling (1 case), scrotal emphysema (2 cases), transient neurapraxia in the area of repair (1 case) and urinary retention (1 case). No chronic pain, foreign body sensation and infection were found. Average hospitalization after operation was (4.3±0.9) d. No recurrence was observed during a follow-up period of 1-15 months. Conclusion 〗Laparoscope herniorrhaphy is safe due to lower recurrence and complications. It also has the advantages of slight pain and rapid recovery.
OBJECTIVE: To investigate the effectiveness of polypropylene path (Prolene) in hernia prevention following harvesting of rectus abdominis is myocutaneous flap. METHODS: From November 1999 to October 2000, Prolene patches were applied in 26 cases to repair the anterior rectus sheath following harvesting free rectus abdominis myocutaneous flap. Data concerning each case included size of rectus flap, defect of rectus sheath, size of patch used, wound healing and complications. RESULTS: Prolene patch showed good biocompatibility with abdominal tissue. No foreign-body rejection occurred after operation. Seroma developed in 1 case, and was drained bedside without complication. All prolene patches healed well in the body during follow-up. Hernia formation and abdominal bulge were not observed. CONCLUSION: Prolene patch is a satisfactory material for repair of the anterior rectus sheath after harvesting free rectus abdominis myocutaneous flap.