Objective To explore the effectiveness of thumb blocking technique through closed reduction of ulnar Kirschner wire threading in the treatment of Gartland type Ⅲ supracondylar humerus fractures in children. MethodsThe clinical data of 58 children with Gartland type Ⅲ supracondylar humerus fractures treated with closed reduction of ulnar Kirschner wire threading by thumb blocking technique between January 2020 and May 2021 were retrospectively analyzed. There were 31 males and 27 females with an average age of 6.4 years ranging from 2 to 14 years. The causes of injury were falling in 47 cases and sports injury in 11 cases. The time from injury to operation ranged from 24.4 to 70.6 hours, with an average of 49.6 hours. The twitch of ring and little fingers was observed during operation, the injury of ulnar nerve was observed after operation, and the healing time of fracture was recorded. At last follow-up, the effectiveness was evaluated by Flynn elbow score, and the complications were observed. Results There was no twitch of the ring and little fingers when the Kirschner wire was inserted on the ulnar side during operation, and the ulnar nerve was not injured. All children were followed up 6-24 months, with an average of 12.9 months. One child had postoperative infection in the operation area, local skin redness and swelling, and purulent secretion exudation at the eye of the Kirschner wire, which was improved after intravenous infusion and regular dressing change in the outpatient department, and the Kirschner wire was removed after the initial healing of the fracture; 2 children had irritation at the end of the Kirchner wire, and recovered after oral antibiotics and dressing change in the outpatient department. There was no serious complication such as nonunion and malunion, and the fracture healing time ranged from 4 to 6 weeks, with an average of 4.2 weeks. At last follow-up, the effectiveness was evaluated by Flynn elbow score, which was excellent in 52 cases, good in 4 cases, and fair in 2 cases, and the excellent and good rate was 96.6%. ConclusionThe treatment of Gartland type Ⅲ supracondylar humerus fractures in children by closed reduction and ulnar Kirschner wire fixation assisted with thumb blocking technique is safe and stable, and will not cause iatrogenic ulnar nerve injury.
ObjectiveTo investigate the feasibility and effectiveness of absorbable anchor combined with Kirschner wire fixation in the reconstruction of extension function of old mallet finger. MethodsBetween January 2020 and January 2022, 23 cases of old mallet fingers were treated. There were 17 males and 6 females with an average age of 42 years (range, 18-70 years). The cause of injury included sports impact injury in 12 cases, sprain in 9 cases, and previous cut injury in 2 cases. The affected finger included index finger in 4 cases, middle finger in 5 cases, ring finger in 9 cases, and little finger in 5 cases. There were 18 patients of tendinous mallet fingers (Doyle type Ⅰ), 5 patients were only small bone fragments avulsion (Wehbe type ⅠA). The time from injury to operation was 45-120 days, with an average of 67 days. The patients were treated with Kirschner wire to fix the distal interphalangeal joint in a mild back extension position after joint release. The insertion of extensor tendon was reconstructed and fixed with absorbable anchors. After 6 weeks, the Kirschner wire was removed, and the patients started joint flexion and extension training. Results The postoperative follow-up ranged from 4 to 24 months (mean, 9 months). The wounds healed by first intention without complications such as skin necrosis, wound infection, and nail deformity. The distal interphalangeal joint was not stiff, the joint space was good, and there was no complication such as pain and osteoarthritis. At last follow-up, according to Crawford function evaluation standard, 12 cases were excellent, 9 cases were good, 2 cases were fair, and the good and excellent rate was 91.3%. Conclusion Absorbable anchor combined with Kirschner wire fixation can be used to reconstruct the extension function of old mallet finger, which has the advantages of simple operation and less complications.
ObjectiveTo summarize the effectiveness of mini locking plate combined with Kirschner wire in treatment of comminuted Jones fracture.MethodsBetween January 2011 and October 2016, 25 cases with comminuted Jones fracture were treated with mini locking plate combined with Kirschner wire. There were 9 males and 16 females with an average age of 31.4 years (range, 16-66 years). The fractures located on the left side in 11 cases and on the right side in 14 cases. The causes of injury included spraining in 21 cases, falling down in 3 cases, and bruise in 1 case. The bone fragment of all cases was more than 3 pieces. The fracture line was mostly Y-shape or T-shape. Twelve of them were combined with other fractures. The time from injury to operation was 1-9 days (mean, 5 days). The mini locking plate and Kirschner wire were removed at 9-12 months postoperatively. At 12 months postoperatively, the pain was evaluated by the visual analogue scale (VAS) score, and the function by the American Orthopaedic Foot & Ankle Society (AOFAS) score.ResultsAll incisions healed by first intention. All cases were followed up 12-36 months with an average of 21.7 months. Fracture union was observed in all patients without complications such as nonunion, delayed union, and malunion. The fracture union time was 8-12 weeks (mean, 9.4 weeks). At 12 months postoperatively, the VAS score was 1.15±0.87; the AOFAS score was 89.45±6.24, and the results were excellent in 14 cases, good in 9 cases, fair in 1 case, and poor in 1 case, with an excellent and good rate of 92%.ConclusionThe procedure of mini locking plate combined with Kirschner wire for comminuted Jones fracture has such advantages as convenient operation, more rigid fixation, high rate of fracture healing, and good functional recovery in foot.
Objective To evaluate the short-term effectiveness of Kirschner wire (K-wire) elastic fixation in the treatment of Doyle type Ⅰ and Ⅱ mallet finger. Methods Between July 2016 and March 2017, 18 patients with Doyle type Ⅰ and Ⅱ mallet finger were treated. There were 12 males and 6 males, with an average age of 45 years (range, 16-61 years). The index finger was involved in 2 cases, the middle finger in 3 cases, the ring finger in 10 cases, and the little finger in 3 cases. The interval from injury to operation ranged from 2 hours to 45 days (median, 5.5 hours). There were 8 patients of closed wound and 10 patients of open wound. Fourteen patients were simply extensor tendon rupture and 4 were extensor tendon rupture complicated with avulsion fracture. The distal interphalangeal joints (DIPJ) of injured fingers were elastically fixed with the K-wire at mild dorsal extend position. The K-wire was removed after 6 weeks, and the functional training started. Results The operation time was 34-53 minutes (mean, 38.9 minutes). Patients were followed up 3-8 months (mean, 5 months). All incisions healed primarily and no K-wire loosening or infection happened during the period of fixation. All mallet fingers were corrected. The range of motion (ROM) in terms of active flexion of injured DIPJ was (75.83±11.15)° at 6 weeks after operation, showing significant difference when compared with the normal DIPJ of contralateral finger [(85.28±6.06)°] (t=3.158, P=0.003). The ROM in terms of active flexion was (82.67±6.78)° in 15 patients who were followed up at 8 months after operation, showing no significant difference when compared with the normal DIPJ of contralateral finger [(86.00±5.73)°] (t=1.454, P=0.157). After the removal of K-wire at 6 weeks, visual analogue scale (VAS) score of active flexion and of passive flexion to maximum angle were 1.78±0.88 and 3.06±1.06, respectively. According to the total active motion criteria, the effectiveness was rated as excellent in 10 cases, good in 5 cases, moderate in 2 cases, and poor in 1 case, and the excellent and good rate was 83.33%. The patients’ satisfaction were accessed by Likert scale, which were 3-5 (mean, 4.2). Conclusion K-wire elastic fixation in the treatment of Doyle typeⅠand Ⅱ mallet finger can repair the extensor effectively, correct the mallet finger deformity, and also be benefit for the flexion-extension function restoration of DIPJ.
Objective To investigate the effectiveness of one-stage closed reduction and elastic compression fixation with double Kirschner wires for Wehbe-Schneider types ⅠB and ⅡB bony mallet fingers. Methods Between May 2017 and June 2020, 21 patients with Wehbe-Schneider type ⅠB and ⅡB bony mallet fingers were treated with one-stage closed reduction and elastic compression fixation using double Kirschner wires. There were 15 males and 6 females with an average age of 39.2 years (range, 19-62 years). The causes of injury were sports injury in 9 cases, puncture injury in 7 cases, and sprain in 5 cases. The time from injury to admission was 5-72 hours (mean, 21.0 hours). There were 2 cases of index finger injury, 8 cases of middle finger injury, 9 cases of ring finger injury, and 2 cases of little finger injury. The angle of active dorsiflexion loss of distal interphalangeal joint (DIPJ) was (40.04±4.02)°. According to the Wehbe-Schneider classification standard, there were 10 cases of typeⅠB and 11 cases of type ⅡB. The Kirschner wire was removed at 6 weeks after operation when X-ray film reexamination showed bony union of the avulsion fracture, and the functional exercise of the affected finger was started. Results The operation time was 35-55 minutes (mean, 43.9 minutes). The length of hospital stay was 2-5 days (mean, 3.4 days). No postoperative complications occurred. All patients were followed up 6-12 months (mean, 8.8 months). X-ray films reexamination showed that all avulsion fractures achieved bony union after 4-6 weeks (mean, 5.3 weeks). Kirschner wire was removed at 6 weeks after operation. After Kirschner removal, the visual analogue scale (VAS) score of pain during active flexion of the DIPJ was 1-3 (mean, 1.6); the VAS score of pain was 2-5 (mean, 3.1) when the DIPJ was passively flexed to the maximum range of motion. The angle of active dorsiflexion loss of affected finger was (2.14±2.54)°, showing significant difference when compared with preoperative angle (t=52.186, P<0.001). There was no significant difference in the active flexion angle between the affected finger (79.52±6.31)° and the corresponding healthy finger (81.90±5.36)° (t=1.319, P=0.195). At 6 months after operation, according to Crawford functional evaluation criteria, the effectiveness was rated as excellent in 11 cases, good in 9, and fair in 1, with an excellent and good rate of 95.24%. Conclusion For Wehbe-Schneider typesⅠB and ⅡB bony mallet fingers, one-stage closed reduction and elastic compression fixation with double Kirschner wires can effectively correct the deformity and has the advantages of simple surgery, no incision, and no influence on the appearance of the affected finger.
Objective To analyze the effectiveness comparison of external fixator combined with Kirschner wire fixation and Kirschner wire fixation in the treatment of cubitus varus deformity in children. Methods A retrospective case-control study was conducted to collect 36 children of postoperative supracondylar humerus fracture complicating cubitus varus deformity between January 2018 and July 2022. Among them, 17 cases were treated with distal humeral wedge osteotomy external fixation combined with Kirschner wire fixation (observation group), and 19 cases were treated with distal humeral wedge osteotomy and Kirschner wire fixation (control group). The baseline data including age, gender, deformity side, time from fracture to operation, carrying angle of the healthy side and preoperative carrying angle of the affected side, elbow flexion and extension range of motion, and lateral condylar prominence index (LCPI) showed no significant difference between the two groups (P>0.05). The operation time, hospitalization cost, healing time of osteotomy, postoperative complications, and the carrying angle, LCPI, and elbow flexion and extention range of motion were recorded and compared between the two groups. The elbow function was assessed by Oppenheim score at 3 months after operation and at last follow-up. Results The children in both groups were followed up 13-48 months, with an average of 26.7 months. There was 1 case of needle tract infection in the observation group and 2 cases in the control group, and no nerve injury occurred, the difference in the incidence of complication (5.88% vs 10.53%) between the two groups was not significant (χ2=0.502, P=0.593). There was no significant difference in the operation time and fracture healing time between the two groups (P>0.05); the hospitalization cost of the observation group was significantly higher than that of the control group (P<0.05). The Oppenheim score of the observation group was significantly better than that of the control group at 3 months after operation (P<0.05), but there was no significant difference in the Oppenheim score between the two groups at last follow-up (P>0.05). At last follow-up, the carrying angle of affected side significantly improved in both groups when compared with preoperative ones (P<0.05); the differences of the pre- and post-operative carrying angle of affected side and elbow flexion and extension range of motion showed no significant differences between the two groups (P>0.05), but the difference in pre- and post-operative LCPI of the observation group was significantly better than that of the control group (P<0.05). ConclusionExternal fixator combined with Kirschner wire fixation and Kirschner wire fixation both can achieve satisfactory correction of cubitus varus deformity in children, and the former can achieve better short-term functional recovery of elbow joint and reduce the incidence of humeral lateral condyle protrusion.
ObjectiveTo analyze the effectiveness of external fixator combined with Kirschner wire (EF-KW) fixation in the treatment of oblique and comminuted distal humeral metaphyseal-diaphyseal junction (DHMDJ) fractures in children. Methods A clinical data of 22 children with DHMDJ fractures who met the selection criteria between April 2021 and December 2023 was retrospectively analyzed. All patients were treated with EF-KW fixation. There were 14 boys and 8 girls with an average age of 6.8 years (range, 1.5-12.0 years). The time from injury to operation was 14-38 hours (mean, 24.2 hours). There were 18 cases of comminuted fractures and 4 cases of oblique fractures; and 1 case of median nerve injury and 1 case of radial nerve injury before operation. The occurrence of postoperative complications was recorded. At last follow-up, the function of the affected elbow joint was evaluated according to the Mayo elbow joint function score, and the Baumann’s angle (BA) and humero-capitellar angle (HCA) of the affected and healthy sides were recorded and compared. ResultsAll fractures were successfully treated with closed reduction and no complications such as nerve injury occurred. Superficial infection occurred in 4 cases after operation and healed after symptomatic treatment. The incisions of other patients healed by first intention. All patients were followed up 9-24 months (mean, 13.8 months). At last follow-up, according to the Mayo elbow joint function score, the elbow joint function was rated as excellent in 15 cases, good in 6 cases, and fair in 1 case, with an excellent and good rate of 95.5%. The neurologic injury before operation recovered gradually. X-ray films reexamination showed that all fractures healed, and the healing time of fractures ranged from 29 to 61 days, with an average of 35.6 days. At last follow-up, there was no significant difference in BA and HCA between the healthy side and the affected side (P>0.05). During follow-up, 1 case developed mild cubitus varus, while the other patients had no serious complications. ConclusionEF-KW fixation for oblique and comminuted DHMDJ fractures in children has the advantages of less trauma, simple operation, easy reduction, good stability after reduction, low incidence of serious complications, and good elbow functional recovery.
Objective To compare the biomechanical stability of Kirschner wire and tension band wiring, reconstruction plate combined with tension band wiring, and olecranon anatomical plate in fixing proximal ulna combined with olecranon fracture, so as to provide the theoretical evidence for clinical selection of internal fixation. Methods Eight specimens of elbow joints and ligaments were taken from eight fresh male adult cadaveric elbows (aged 26-43 years, mean 34.8 years) donated voluntarily. The model of proximal ulna combined with olecranon fracture was made by an osteotomy in each specimen. Fracture end was fixed successively by Kirschner wire and tension band wiring (group A), reconstruction plate combined with tension band wiring (group B), and olecranon anatomical plate (group C), respectively. The biomechanical test was performed for monopodium compression experiments, and load-displacement curves were obtained. The stability of the fixation was evaluated according to the load value when the compression displacement of fracture segment was 2 mm. Results No Kirschner wire withdrawal, broken plate and screw, loosening and specimens destruction were observed. The load-displacement curves of 3 groups showed that the displacement increased gradually with increasing load, while the curve slope of groups B and C was significantly higher than that of group A. When the compression displacement was 2 mm, the load values of groups A, B, and C were (218.6 ± 66.9), (560.3 ± 116.1), and (577.2 ± 137.6) N, respectively; the load values of groups B and C were significantly higher than that of group A (P lt; 0.05), but no significant difference was observed between groups B and C (t=0.305, P=0.763). Conclusion The proximal ulna combined with olecranon fracture is unstable. Reconstruction plate combined with tension band wiring and olecranon anatomical plate can meet the requirement of fracture fixation, so they are favorable options for proximal ulna combined with olecranon fracture. Kirschner wire and tension band wiring is not a stable fixation, therefore, it should not be only used for proximal ulna combined with olecranon fracture.
Objective To evaluate the effectiveness of Kirschner wire fixation and coracoclavicular ligament reconstruction with suture anchor in the treatment of Cho type ⅡC distal clavicle fractures. Methods The data of 17 patients with Cho type ⅡC distal clavicular fractures, who were treated with Kirschner wire fixation and coracoclavicular ligament reconstruction with suture anchor between June 2019 and June 2021, was retrospectively analyzed. There were 11 males and 6 females with an average age of 38.7 years (range, 19-72 years). The fractures were caused by falling in 12 cases and traffic accident in 5 cases. All patients had fresh closed fractures. The interval from injury to operation was 1-5 days (mean, 2.6 days). The preoperative injury severity score (ISS) was 6-27 (mean, 10.2). The operation time, intraoperative blood loss, hospital stay, fracture healing, and postoperative complications were analyzed. The shoulder joint function was evaluated by disabilities of the arm, shoulder, and hand (DASH) score and Constant score at last follow-up. Results All operations were completed successfully. The operation time was 20-50 minutes (mean, 31.6 minutes). The intraoperative blood loss was 30-100 mL (mean, 50.6 mL). The hospital stay was 4-9 days (mean, 5.3 days). All incisions healed by first intention. All patients were followed up 12-16 months (mean, 13 months). All clavicle fractures healed, and the healing time was 8-15 weeks (mean, 11 weeks). No complications such as fracture displacement or nonunion caused by internal fixation failure occurred. During the follow-up, skin irritation caused by the Kirschner wire withdrawal occurred in 3 cases. The Kirschner wires were removed after fracture healing in 17 patients. At last follow-up, the Constant score of shoulder joint was 90-100 (mean, 98.2). The DASH score was 0-10 (mean, 1.5). ConclusionKirschner wire fixation combined with coracoclavicular ligament reconstruction with suture anchor in the treatment of Cho type ⅡC distal clavicle fractures has less postoperative complications and slight complications. It is convenient to remove the internal fixator. The Kirschner wire does not fix the distal clavicle fracture through the acromion, which has little effect on shoulder joint function and can obtain good effectiveness.
Objective To compare the effectiveness of open reduction and internal fixation with plate and closed reduction and internal fixation with Kirschner wire (K-wire) in the treatment of intra-articular displaced calcaneal fractures in older children. MethodsA clinical data of 35 older children (37 feet) with intra-articular displaced calcaneal fractures who were admitted between November 2014 and November 2020 and met the selection criteria were retrospectively analyzed. Among them, 19 cases (20 feet) underwent open reduction and internal fixation with plate (plate group), and 16 cases (17 feet) underwent closed reduction and internal fixation with K-wire (K-wire group). There was no significant difference in gender, age, cause of injury, side and type of fracture, and time from injury to admission, and preoperative calcaneal Gissane angle and Böhler angle (P>0.05). The postoperative calcaneal Gissane angle, Böhler angle, complications, and fracture healing were compared between the two groups. The ankle function was evaluated based on the American Orthopedic Foot and Ankle Society (AOFAS) ankle-hindfoot scoring system. Results Incision necrosis occurred in 1 foot in the plate group after operation, which healed after symptomatic treatment; the other incisions in the two groups healed by first intention. All children were followed up 12-39 months (mean, 19 months). X-ray films showed that the fractures in both groups healed; the healing time was (2.65±0.71) months in the plate group and (2.24±1.38) months in the K-wire group respectively, with no significant difference (t=1.161, P=0.253). At last follow-up, the calcaneal Gissane angle and Böhler angle returned to normal; and the difference between pre- and post-operation in the two group was significant (P<0.05), but there was no significant difference between the two groups in the difference between before and after operation (P>0.05). In the plate group, the plate was removed at 11-22 months after operation (mean, 16.8 months). At last follow-up, the AOFAS ankle-hindfoot score in the plate group was 91.2±5.1, which was significantly higher than that in the K-wire group (86.9±6.1) (t=2.316, P=0.027). The ankle function was rated as excellent in 15 feet, good in 4 feet, and fair in 1 foot in the plate group, and excellent in 14 feet and good in 3 feet in the K-wire group, and the difference between the two groups was not significant (Z=1.712, P=0.092). ConclusionFor intra-articular displaced calcaneal fracture in older children, the open reduction and internal fixation with plate and closed reduction and internal fixation with K-wire can achieve good effectiveness, but the former has better recovery of ankle function.