west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Prosthesis" 31 results
  • Incidence of prosthesis-patient mismatch and early postoperative outcome in elderly patients undergoing aortic valve replacement

    Objective To analyze the incidence of valve prosthesis-patient mismatch (PPM) and ventricular remodeling of elderly patients after aortic valve replacement (AVR). Methods We retrospectively analyzed the clinical data of 134 patient aged over 65 years who underwent AVR for the aortic stenosis or regurgitation at our hospital between January 2016 and December 2016. There were 73 males and 61 females aged 69.7±3.6 years ranging from 65-79 years. The clinical and ultrasound cardiography data were evaluated. PPM was defined as an effective orifice area index (EOAI) of ≤0.85 cm2/m2. The incidence of PPM and the left ventricular remodeling after surgical AVR in the patients with aortic stenosis and aortic regurgitation was analyzed, and the outcomes of aortic valve mechanical prosthesis and aortic valve bioprosthesis were compared. Results The incidence of PPM was 32.5% in aortic stenosis and 13.0% in aortic regurgitation (P<0.05). One patient died in the early post-operation, and the incidence of severe PPM was 6.0%. Conclusion The incidence of PPM after AVR in the patients with aortic regurgitation is less than that in the patients with aortic stenosis.

    Release date:2018-07-27 02:40 Export PDF Favorites Scan
  • REVIEW ON THE PROGRESS OF PERIPHERAL NERVOUS MICROELECTRODE

    Objective To review the progress and application of peripheral nervous microelectrode. Methods The recent articles on peripheral nervous microelectrode were extensively reviewed. The classification, the progress of the peripheral nervous microelectrode and its utilizable prospect in the control of electronic prosthesis were summarized. Results The microelectrodes had favorable functions of selective stimulation and recording. It provided an information transmitting interface between the electric prosthesis and peripheral nerves. Conclusion Peripheral nervous signal is a feasible signal source to control electronic prosthesis.

    Release date:2016-09-01 09:29 Export PDF Favorites Scan
  • APPLICATIONS OF MYO-PERIOSTEAL FIBULAR BONE BRIDGING FOR TRAUMATIC TRANSTIBIAL AMPUTATION

    Objective To compare the effectiveness between the myo-periosteal fibular bone bridging and traditional transtibial amputation in the treatment of amputation below knee so as to provide theoretical basis for choosing transtibial amputation in clinical application. Methods Between November 2001 and November 2011, 38 patients with mangled lower extremity were treated by transtibial amputation. Among 38 patients, 17 (group A) underwent myo-periosteal fibular bone bridging (the operation techniques of an attached peroneal muscle myo-periosteal fibular strut bridge between the end of the tibia and fibula below knee amputation), and other 21 (group B) underwent traditional transtibial amputation. There was no significant difference in age, gender, injury cause, amputation cause, side, and disease duration between 2 groups (P gt; 0.05). The quality of life (QOL) was analyzed using 36-item short form health survey (SF-36), and prosthesis satisfaction by Trinity amputation and prosthesis experience scale (TAPES). Results Healing of incision by first intention was obtained in all patients of 2 groups; no necrosis, infection, or poor stumps was observed. The mean follow-up time was 22 months (range, 14-30 months) in group A, and 26 months (range, 15-30 months) in group B. The patients achieved good healing of bone bridging, no bone nonunion occurred. The healing time was (5.1 ± 1.1) months in group A and (3.3 ± 0.6) months in group B, showing significant difference between 2 groups (t=9.82, P=0.00). Spur occurred at the distal fibula in an 11-year-old boy of group B after 2 years of operation, which blocked use of prosthesis; prosthesis was well used in the other patients. After 12 months of operation, SF-36 score was 55.84 ± 14.01 in group A and 49.93 ± 12.78 in group B, showing significant difference (P lt; 0. 05); the physical functioning, social functioning, role-physical, vitality, body pain, general health scores in group A were significantly higher than those in group B (P lt; 0.05), but no significant difference was found in role-emotional and mental health scores between 2 groups (P gt; 0.05). TAPES score was 12.12 ± 2.23 in group A and 10.10 ± 2.00 in group B, showing significant difference (t=2.891, P=0.006). Conclusion It is a very effective method to treat traumatic amputation using an attached myo-periosteal fibular bone bridging between the end of the tibia and fibula below knee, which can afford better quality of life and prosthesis satisfaction.

    Release date:2016-08-31 04:05 Export PDF Favorites Scan
  • INFLUENCES OF PREOPERATIVE SEVERE LOWER LIMB DEFORMITY ON PROSTHESIS INSTALLATION AND ALIGNMENT RESTORATION IN TOTAL KNEE ARTHROPLASTY

    ObjectiveTo investigate the effect of preoperative valgus or varus deformity on the prosthesis installation and alignment restoration in total knee arthroplasty (TKA). MethodsBetween January 2012 and December 2013, 198 patients (245 knees) with osteoarthritis underwent primary TKA, and the clinical data were retrospectively analyzed. There were 23 males and 175 females, with the average age of 67 years (range, 43-90 years). Single knee and double knees were involved in 151 and 47 cases respectively. The disease duration was from 1 month to 30 years (mean, 8.99 years). The anteroposterior X-ray films of whole lower limbs were taken, and the femorotibial angle (FT) was measured before operation and at 1 week after operation; the mechanical femoral angle (MF) and the anatomical tibial angle (AT) at 1 week after operation were measured. The correlation analysis was made for pre-and post-operative FT, MF, and AT. According to the valgus or varus deformity before operation, all patients were divided into 5 groups:≥20° varus (group A), 10-20° varus (group B), ≤10° varus (group C), < 10° valgus (group D), and≥10° valgus (group E), and the above indicators were compared between groups. And the rate of the good limb alignment was recorded after operation. ResultsThe pre-and post-operative FT were (171.53±9.12) and (177.38±3.57)° respectively, and postoperative MF and AT were (89.00±2.68) and (88.62±2.16)° respectively. Preoperative FT was associated with postoperative FT and MF (r=0.375, P=0.000; r=0.386, P=0.000), but it was not correlated with AT (r=0.024, P=0.710). Postoperative FT was associated with MF and AT (r=0.707, P=0.000; r=0.582, P=0.000). Postoperative FT was significantly increased when compared with preoperative FT in each group (P < 0.05). There were significant differences in preoperative FT between groups (P < 0.05). There were significant differences in postoperative FT when compared group A with groups B, C, D, and E (P < 0.05), and when compared groups B and C with groups D and E (P < 0.05), but there was no significant difference between groups B and C, and between groups D and E (P>0.05). The rate of good alignment was 70.2% (172/245); it was 27.8% (5/18), 66.0% (62/94), 74.4% (67/90), 88.9% (32/36), and 85.7% (6/7) in groups A, B, C, D, and E respectively, showing significant differences between groups (P < 0.05). There was no significant difference in postoperative AT between groups (P>0.05). Except for between group D and group E (P>0.05), significant difference in MF was shown between the other groups (P < 0.05). ConclusionThe more severe deformity of lower limb before TKA, the higher risk of deviation for prosthesis installation and poor alignment in TKA.

    Release date: Export PDF Favorites Scan
  • PHOTOELASTIC STUDY OF FRACTURE OF PROSTHETIC STEM AFTER FEMORAL HEAD REPLACEMENT

    Abstract The fracture of the prosthetic stem after prosthetic replacement of femoral head is not rare. In this study, the photoeastic instrument was used to study the stress distribution on the prosthetic stem following its insertion and to analyse the factors influencing the fracture of the stem. Through the examination of 9 places in 8 cases, it was found that:(1) The removal of femoral calcar and the inframedullary filling of the bone cement directly influenced the stress distribution. (2) The valgus or varus condition of the prosthesis would lead to stress concentration on the stem. (3) Once lossening of the prosthesis occured it would change the preliminary installingstress distribution in the upper femur which would lead to fatigue fracture. Ths experimental data and clinical observation would provide scientific basis forthe prevention of fracture of prosthetic stem following prosthetic replacement of femoral head.

    Release date:2016-09-01 11:10 Export PDF Favorites Scan
  • Rehabilitation Nursing for Patients with Lower Limb Amputation before Prosthetic Fitting

    ObjectiveTo explore the clinical effect of systematic rehabilitation nursing for patients with lower limb amputation before prosthesis fitting. MethodsFifty patients with lower limb amputation before prosthetic fitting from January 2009 to December 2012 were assessed by rehabilitation team members, and then received the nursing progress according to the assessment results. The conditions of the patients before and after nursing intervention were evaluated and compared. ResultsAfter the patients received systematic rehabilitation nursing intervention, the standard rate of rehabilitation nursing knowledge and satisfaction rate of the nursing quality at the departure of the patients was 87.24% and 93.25% respectively. The muscle strength reached level 4 or higher in 4 patients, who could have the prosthesis fitting. ConclusionSystematic rehabilitation nursing for patients with lower limb amputation before prosthesis fitting can help patients to reserve the function as possible, improve the ability of living and quality of life, and reduce the burden of the patients and family to return to society earlier.

    Release date: Export PDF Favorites Scan
  • IMPACT OF DIFFERENCES OF POSTERIOR CONDYLE CARTILAGE WEAR ON ROTATIONAL POSITIONING OF FEMORAL PROSTHESIS IN TOTAL KNEE ARTHROPLASTY FOR OSTEOARTHRITIS PATIENTS

    Objective To investigate the impact of difference between the medial and lateral posterior condyle cartilage thickness on osteotomy in total knee arthroplasty (TKA) by measuring the thickness of the medial and lateral femur posterior condylar cartilage and the posterior condylar angle (PCA) in osteoarthritis (OA) patients. Methods Between May and December 2011, 53 OA patients (60 knees) scheduled for TKA met the inclusion criteria (OA group). There were 12 males (14 knees) and 41 females (46 knees), aged 57-82 years (mean, 71.9 years). The tibiofemoral angle was (183.2 ± 2.6) ° . Fifteen healthy volunteers (30 knees) were taken as controls (control group); there were 6 males and 9 females, aged 59-68 years (mean, 66.3 years). MRI scan data were imported into Mimics10.01 medical image control system to measure the thickness of femur posterior condylar cartilage and the PCA with and without femur posterior condylar cartilage. Results In the control group, the thickness of the medial and lateral femur posterior condylar cartilage was (1.85 ± 0.33) mm and (1.92 ± 0.27) mm respectively, the PCA with and without femur posterior condylar cartilage was (5.0 ± 0.9)° and (5.1 ± 0.8)° respectively, all showing no significant differences (P gt; 0.05). In OA group, the thickness of the medial and lateral femur posterior condylar medial cartilage was (0.45 ± 0.40) mm and (1.78 ± 0.51) mm respectively, the PCA with and without femur posterior condylar cartilage was (3.3 ± 1.7)° and (4.8 ± 1.8)° respectively, all showing significant differences (P lt; 0.05). In OA group, the difference between lateral and medial cartilage thickness was (1.33 ± 0.45) mm, and the difference between PCA with and without femur posterior condylar cartilage was (1.5 ± 1.3)°. There was a positive correlation between the difference of cartilage thickness and the difference of PCA (r=0.75, P=0.01). Conclusion There is significant difference between medial and lateral femur posterior condylar cartilage wear, which leads to difference of PCA. The difference will impact knee function and longevity of the prosthesis, so the difference should be considered during osteotomy.

    Release date:2016-08-31 04:21 Export PDF Favorites Scan
  • Application of Preperitoneal Tension-Free Repair in Inguinal Hernia by Easy Prosthesis D-10

    Objective To evaluate the clinical effect of Easy Prosthesis D-10 on open preperitoneal groin tension-free hernioplasty. Methods The operative time, operation-correlated complications, hospital stay and recent follow-up findings of 63 patients underwent preperitoneal groin tension-free hernioplasty were analyzed from October 2006 to April 2008. Results No case died in perioperative period. The average operative time was (47.6±10.5) minutes. None of incision infection and scrotal hydrocele occurred. The average hospital stay was (7.7±2.1) days. During follow-up period of 6 to 24 months, no recurrence, chronic pain and foreign body sensation were found. Conclusion The open preperioneal groin tension-free hernioplasty by Easy Prosthesis D-10 is safe and reliable, especially for the inguinal hernia with large hernia ring or defect of transversalis fascia and recurrent hernia.

    Release date:2016-09-08 10:57 Export PDF Favorites Scan
  • Compar ing Study of Heart Function of Biolog ical Valves Replacemen t with Mechan ical Valves Replacemen t in Patien ts with Small Aortic Root

    Abstract:  Objective  To compare the change of left heart funct ion in pat ients w ith bio logical valves replacement of small ao rt ic roo t w ith mechanical valve rep lacement, and to find w hether there is p ro sthesis-patient mismatch (PPM ) or not after operation.  Methods Left ventricular ejection fraction (LV EF ) , left ventricular fractional shortening (LVFS) , left vent ricular mass index, the indexed effective orifice area (EOA I) , and peak pressure gradients across aortic valve in 20 patients with small aortic root (≤21mm in diameter) receiving biological valves rep lacement (biological valves group ) were studied by Doppler echocardiography before the operation and 6 months to 1 year after operation. The results were compared with those of 20 patients who received mechanical valves replacement (mechanical valves group ).  Results Comparing with those before operation, there was a significant increase in LVEF, LV FS, EOAI of all patients 6 months to 1 year after operation . There was a significant reduction in the left ventricular mass index, peak pressure gradients across aortic valve in all patients. EOAI of all patients were between 0.88 cm2/m2 and 1. 32 cm 2/m 2. LVEF, LVFS, EOAI, left ventricular mass index, and peak pressure gradients across aortic valve between biological valves group and mechanical valves group (79% ±8% vs. 81%±10%; 43%±9% vs. 37%±8%; 1. 11±0. 14 vs. 0. 92±0. 11; 89. 10±16. 70g/m 2 vs. 95. 30±15.10 g/m 2; 18. 80±12. 60 mmHg vs. 22. 30±12. 00 mmHg) showed no significant difference 6 months to 1 year after operation (P gt;0.05).  Conclus ion Patients with small aortic root receiving biological valves have a significant increase in the left heart function, and have no PPM.

    Release date:2016-08-30 06:08 Export PDF Favorites Scan
  • Finite element analysis of the effect of knee movable unicompartmental prosthesis insertion shape and mounting position on stress distribution in the knee joint after replacement

    In unicompartmental replacement surgery, there are a wide variety of commercially available unicompartmental prostheses, and the consistency of the contact surface between the common liner and the femoral prosthesis could impact the stress distribution in the knee after replacement in different ways. Medial tibial plateau fracture and liner dislocation are two common forms of failure after unicompartmental replacement. One of the reasons is the mismatch in the mounting position of the unicompartmental prosthesis in the knee joint, which may lead to failure. Therefore, this paper focuses on the influence of the shape of the contact surface between the liner and the femoral prosthesis and the mounting position of the unicompartmental prosthesis on the stress distribution in the knee joint after replacement. Firstly, a finite element model of the normal human knee joint was established, and the validity of the model was verified by both stress and displacement. Secondly, two different shapes of padded knee prosthesis models (type A and type B) were developed to simulate and analyze the stress distribution in the knee joint under single-leg stance with five internal or external rotation mounting positions of the two pads. The results showed that under a 1 kN axial load, the peak contact pressure of the liner, the peak ACL equivalent force, and the peak contact pressure of the lateral meniscus were smaller for type A than for type B. The liner displacement, peak contact pressure of the liner, peak tibial equivalent force, and peak ACL equivalent force were the smallest for type A at 3° of internal rotation in all five internal or external rotation mounting positions. For unicompartmental replacement, it is recommended that the choice of type A or type B liner for prosthetic internal rotation up to 6° should be combined with other factors of the patient for comprehensive analysis. In conclusion, the results of this paper may reduce the risk of liner dislocation and medial tibial plateau fracture after unicompartmental replacement, providing a biomechanical reference for unicompartmental prosthesis design.

    Release date:2022-10-25 01:09 Export PDF Favorites Scan
4 pages Previous 1 2 3 4 Next

Format

Content