west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "cannulated screw" 16 results
  • Treatment of Day type Ⅱ pelvic crescent fracture by using percutaneous cannulated screw fixation technique

    ObjectiveTo evaluate the feasibility and effectiveness of percutaneous cannulated screw fixation for the treatment of Day type Ⅱ pelvic crescent fracture.MethodsThe clinical data of 14 patients with Day type Ⅱ pelvic crescent fractures underwent closed reduction and percutaneous cannulated screw fixation between January 2009 and July 2016 were retrospectively analysed. There were 9 males and 5 females, aged 17-65 years (mean, 38 years). The causes of injury included traffic accident in 8 cases, falling from height in 3 cases, bruise injury in 3 cases; all were closed fractures. According to Tile classification, there were 8 cases of type B, 6 cases of type C. There were 13 cases combined with fracture of the anterior pelvic ring, including 8 cases of superior and inferior ramus of pubis fracture, 1 case of superior ramus of pubis fracture with symphysis separation, and 4 cases of symphysis separation. The interval of injury and admission was 1- 72 hours (mean, 16 hours), and the interval of injury and operation was 3-8 days (mean, 5 days). After operation, the reduction of fracture was evaluated by the Matta evaluation criteria, the clinical function was assessed by Majeed function assessment.ResultsThe operation time was 35-95 minutes (mean, 55 minutes), cumulative C-arm fluoroscopy time was 3-8 minutes (mean, 5 minutes), no iatrogenic vascular injury and pelvic organ damage occurred. Postoperative X-ray films at 2 days indicated that 2 cases of vertical shift and 2 cases of mild rotation were not completely corrected. Postoperative CT examination at 3 days indicated that 2 pubic joint screws broke through the obturator bone cortex. None of the pubic ramus screws entered into the acetabulum, but a screw of superior pubic branch broke through the posterior cortical of superior pubic branch, a screw of posterior ilium column broke through the medial bone cortex of the ilium, and no clinical symptom was observed. One patient suffered from wound infection in the pubic symphysis, then healed after 2 weeks of wound drainage, the other wounds healed by first intention. According to Matta criterion for fracture reduction, the results were excellent in 9 cases, good in 4 cases, and fair in 1 case with an excellent and good rate of 92.9%. All patients were followed up 8-24 months (mean, 14 months). All fractures healed at 4 months and restored to the normal walking at 6 months after operation, 3 patients suffered from slight pain in the sacroiliac joints and slight claudication when they were tired or walked for a long time and unnecessary for special treatment. One patient felt pain in the back of the iliac spine when he was lying down. During the follow-up, no screw loosening or other internal fixation failure occurred. At last follow-up, according to Majeed functional evaluation criteria, the results were excellent in 7 cases, good in 5 cases, and fair in 2 cases with an excellent and good rate of 85.7%.ConclusionThe percutaneous cannulated screw fixation is a safe treatment for Day type Ⅱ pelvic crescent fracture, which has a reliable fixation and good effectiveness.

    Release date:2018-02-07 03:21 Export PDF Favorites Scan
  • EXPERIMENTAL STUDY ON TREATMENT OF LATERAL FEMORAL CONDYLE FRACTURE WITH POLYLACTIC-CO-GLYCOLIC ACID/HYDROXYAPATITE ABSORBABLE CANNULATED SCREWS IN CANINE

    Objective To evaluate the internal fixation effect, degradation, and biocompatibility of polylactic-co-glycolic acid/hydroxyapatite (PLGA/HA) absorbable cannulated screws in treatment of lateral femoral condyle fracture of canine so as to provide the theory basis for their further improvement and clinical application. Methods Sixteen adult male Beagles (weighing, 9-12 kg) were selected to prepare the models of bilateral lateral femoral condyle fracture; left fracture was fixed with PLGA/HA absorbable cannulated screws as experimental group and right fracture with metal screws as control group. At 2, 4, 8, and 12 weeks after operation, general observation was done and X-ray films were taken for observing fracture healing; bone mineral density was measured; the histological examination was performed; and the degradation property of absorbable cannulated screws was detected. Results All animals survived to the end of the experiment. General observations showed that no fracture displacement occurred and fracture healed at 12 weeks in 2 groups; no breakage, displacement, or loosening of screws was observed in experimental group. X-ray films results showed that the absorbable cannulated screws could not be found out by X-ray in experimental group, but metal screws could be found out in control group; fracture healed with time in 2 groups. The bone mineral density reached the peak at 8 weeks in 2 groups, and no significant difference was found between 2 groups and among different time points in the same group (P gt; 0.05). Histological examination showed that 2 groups had similar fracture healing process at different time points; no obvious inflammatory reaction was found around absorbable cannulated screws in experimental group. The degradation results of absorbable cannulated screws showed that the intrinsic viscosity and molecular weight distribution obviously decreased at 2 weeks; the number average molecular weight and the weight average molecular weight markedly decreased at 4 weeks; and the maximum shear force did not decrease obviously at 8 weeks, and then decreased significantly. Significant differences were found in all indexes among different time points in the same group (P lt; 0.05). Conclusion PLGA/HA absorbable cannulated screws and metal screws show similar fracture healing process for fixing lateral femoral condyle fracture of canine, and the absorbable canulated screws have good biocompatibility. The maximum shear force of PLGA/HA absorbable cannulated screw has no obvious decrease during 8 weeks after operation, so it can ensure full healing of fracture.

    Release date:2016-08-31 04:07 Export PDF Favorites Scan
  • Dynamic hip screw combined with anti-rotation screw versus cannulated screw alone for femoral neck fracture in adults: a meta-analysis

    Objective To compare the efficacy and safety of dynamic hip screw (DHS) + anti-rotation screw and cannulated screw alone for femoral neck fracture in adults. Methods PubMed, Web of Science, Cochrane Library, China National Knowledge Infrastructure, SinoMed, Wanfang, and Chongqing VIP database were searched for the literature related to the comparison between DHS + anti-rotation screw and cannulated screw alone for femoral neck fracture in adults from the establishment of databases to 2022. RevMan 5.3 software was used for meta-analysis. Results Finally, 25 clinical studies were included, including 8 randomized controlled trials and 17 observational studies, 5 in English and 20 in Chinese. There were a total of 2099 patients, including 989 in the DHS + anti-rotation screw group and 1110 in the cannulated screw group. The meta-analysis results showed that the incidence of bone nonunion [odds ratio (OR)=0.29, 95% confidence interval (CI) (0.17, 0.48)], incidence of femoral head necrosis [OR=0.48, 95% CI (0.27, 0.88)], failure rate of internal fixation [OR=0.28, 95% CI (0.15, 0.51)] in the DHS + anti-rotation screw group were lower than those in the cannulated screw group (P<0.05). The surgical duration [mean difference (MD)=9.91, 95% CI (6.78, 13.05)], incision length [MD=1.25, 95% CI (0.15, 2.35)], and Harris score [MD=6.77, 95% CI (4.66, 8.88)] in the DHS + anti-rotation screw group were higher than those in the cannulated screw group (P<0.05). There was no statistically significant difference in intraoperative bleeding volume, Visual Analogue Scale score, hospital stay, and fracture healing time between the two groups (P>0.05). The incidence of bone nonunion in the DHS + anti-rotation screw group after Pauwels type Ⅲ fracture [OR=0.16, 95% CI (0.05, 0.50)] was lower than that in the cannulated screw group (P<0.05), and there was no statistically significant difference in the incidence of femoral head necrosis between the two groups (P>0.05). Conclusions For femoral neck fracture in adults, DHS + anti-rotation screw can reduce the incidence of bone nonunion, femoral head necrosis, and internal fixation failure compared with cannulated screw alone, and has a higher Harris score, but the surgical duration and incision are longer. Overall, DHS + anti-rotation screw are better at reducing the incidence of complications than cannulated screws alone.

    Release date:2023-04-24 08:49 Export PDF Favorites Scan
  • CLINICAL RESEARCH OF INDIVIDUAL PERCUTANEOUS CANNULATED SCREWS FIXATION FOR TREATMENT OF Herbert TYPE Ib SCAPHOID FRACTURE

    ObjectiveTo investigate the effectiveness of individual percutaneous cannulated screws fixation of computer-assisted design combined with three-dimensional (3D) guide plate by comparing with cast immobilization and open internal fixation for treatment of Herbert type Ib scaphoid fracture. MethodsBetween January 2010 and June 2015, 56 patients with fresh Herbert type Ib scaphoid fracture were treated with cast immobilization in 16 cases (external fixation group), with open reduction and internal fixation in 20 cases (open reduction group), and with individual percutaneous cannulated screws fixation of computer-assisted design combined 3D guide plate in 20 cases (minimal invasion group). There was no significant difference in gender, age, injury cause, side, disease duration, and classification of fractures between groups P>0.05).The time of bone union, bone nonunion rate, return-to-work time, wrist range of motion (ROM), and Mayo function score were recorded and compared. ResultsPrimary healing of incision was obtained in open reduction group and minimally invasion group, without related complications. The cases were followed up 10-24 months (mean, 16.6 months). The time of bone union and return-to-work time of minimal invasion group were significantly shorter than those of the other 2 groups (P<0.05), and the rate of bone nonunion was significantly lower than that of the other 2 groups (P<0.05). At last follow-up, the wrist ROM of minimal invasion group[(104.40±3.46)°] was significantly larger than that of external group[(94.20±2.42)°] and open reduction group[(96.40±2.66)°] (P<0.05). According to Mayo function score, the results were excellent in 6 cases, good in 5 cases, fair in 2 cases, and poor in 3 cases in external fixation group, with an excellent and good rate of 69%; the results were excellent in 9 cases, good in 7 cases, fair in 2 cases, and poor in 2 cases in open reduction group, with an excellent and good rate of 80%; the results were excellent in 16 cases, good in 3 cases, and fair in1 case in minimal invasion group, with an excellent and good rate of 95%; there was significant difference in excellent and good rate among groups (P<0.05). ConclusionIndividual percutaneous cannulated screws fixation of computer-assisted design combined with 3D guide plate has satisfactory effectiveness in the treatment of Herbert type Ib scaphoid fractures, with the advantages of mini-invasion, high accuracy, high rate of bone union, less complication, early return-to-work time.

    Release date:2016-10-21 06:36 Export PDF Favorites Scan
  • Comparison of full thread compression cannulated screw and partial thread cannulated screw in treatment of femoral neck fracture

    Objective To compare the effectiveness of full thread compression cannulated screw and partial thread cannulated screw in the treatment of femoral neck fracture. Methods A retrospective analysis was made on 152 patients with femoral neck fractures, who met the selection criteria, between April 2013 and February 2021. The fractures were fixed with the full thread compression cannulated screws in 74 cases (trial group) and the partial thread cannulated screws in 78 cases (control group). There was no significant difference in general data such as age, gender, body mass index, cause of injury, time from injury to operation, and the side, Garden typing, Pauwels typing of fracture between the two groups (P>0.05). The operation time, intraoperative blood loss, hospital stay, follow-up time, and Harris score were recorded in both groups. X-ray films were performed to evaluate the quality of fracture reduction and bone healing, the changes of neck-shaft angle, the changes of femoral neck, as well as the occurrence of internal fixation failure, screw back-out, and osteonecrosis of the femoral head. Results There was no significant difference in operation time and hospital stay between the two groups (P>0.05). However, the intraoperative blood loss in the trial group was significantly lower than that in the control group (P<0.05). Patients in both groups were followed up, with the follow-up time of (24.11±4.04) months in the trial group and (24.10±4.42) months in the control group, and the difference was not significant (P>0.05). Postoperative X-ray films showed that there was no significant difference in fracture reduction grading between the two groups (P>0.05). Six cases in the trial group developed bone nonunion and 7 cases in the control group, the fractures of the other patients healed, and the healing time was significantly shorter in the trial group than in the control group (P<0.05). There was no significant difference in the incidence of bone nonunion between the two groups (P>0.05). During follow-up, 2 cases in the trial group and 5 cases in the control group had osteonecrosis of the femoral head, the difference was not significant (P>0.05), and the patients with osteonecrosis of the femoral head were treated with secondary operation. The screw back-out occurred in 3 cases of the trial group and in 9 cases of the control group, showing no significant difference (P>0.05). But the screw back-out distance was significantly shorter in the trial group than in the control group (P<0.05). The incidence of internal fixation failure in the trial group (4 cases) was significantly lower than that in the control group (14 cases) (P<0.05). The incidence of femoral neck shortening and the change of neck-shaft angle at 1 year after operation were significantly lower in the trial group than in the control group (P<0.05). The Harris score at last follow-up was significantly higher in the trial group than in the control group (P<0.05). Conclusion Compared with the partial threaded cannulated screws, the full threaded cannulated compression screws can effectively maintain fracture reduction, avoid femoral neck shortening, and internal fixation failure. It is a better choice for femoral neck fracture.

    Release date:2023-02-13 09:57 Export PDF Favorites Scan
  • Analysis of effectiveness of Holosight robot navigation-assisted percutaneous cannulated screw fixation in treatment of femoral neck fractures

    Objective To investigate the effectiveness of Holosight robotic navigation-assisted percutaneous cannulated screw fixation for femoral neck fractures. Methods A retrospective analysis was conducted on 65 patients with femoral neck fractures treated with cannulated screw fixation between January 2022 and February 2024. Among them, 31 patients underwent robotic navigation-assisted screw placement (navigation group), while 34 underwent conventional freehand percutaneous screw fixation (freehand group). Baseline characteristics, including age, gender, fracture side, injury mechanism, Garden classification, Pauwels classification, and time from injury to operation, showed no significant differences between the two groups (P>0.05). The operation time, intraoperative blood loss, fluoroscopy frequency, fracture healing time, and complications were recorded and compared, and hip function was evaluated by Harris score at last follow-up. Postoperative anteroposterior and lateral hip X-ray films were taken to assess screw distribution accuracy, including deviation from the femoral neck axis, inter-screw parallelism, and distance from screws to the femoral neck cortex. Results No significant difference was observed in operation time between the two groups (P>0.05). However, the navigation group demonstrated superior outcomes in intraoperative blood loss, fluoroscopy frequency, deviation from the femoral neck axis, inter-screw parallelism, and distance from screws to the femoral neck cortex (P<0.05). No incision infections or deep vein thrombosis occurred. All patients were followed up 12-18 months (mean, 16 months). In the freehand group, 1 case suffered from cannulated screw dislodgement and nonunion secondary to osteonecrosis of femoral head at 1 year after operation, 1 case suffered from screw penetration secondary to osteonecrosis of femoral head at 5 months after operation; and 1 case suffered from nonunion secondary to osteonecrosis of femoral head at 6 months after operation in the navigation group. All the 3 patients underwent internal fixators removal and total hip arthroplasty. There was no significant difference in the incidence of complications between the two groups (P>0.05). The fracture healing time and hip Harris score at last follow-up in the navigation group were significantly better than those in the freehand group (P<0.05). ConclusionCompared to freehand percutaneous screw fixation, Holosight robotic navigation-assisted cannulated screw fixation for femoral neck fractures achieves higher precision, reduced intraoperative radiation exposure, smaller incisions, and superior postoperative hip function recovery.

    Release date:2025-06-11 03:21 Export PDF Favorites Scan
  • Comparison of femoral neck system and inverted triangle cannulated screws fixations in treatment of Pauwels typle Ⅲ femoral neck fractures

    ObjectiveTo compare the effectiveness of the femoral neck system (FNS) and inverted triangle cannulated screws (ITCS) for the treatment of Pauwels type Ⅲ femoral neck fractures.MethodsThe clinical data of 59 patients with Pauwels type Ⅲ femoral neck fractures treated between May 2019 and November 2020 were retrospectively analysed. The patients were divided into FNS group (28 cases) and ITCS group (31 cases) according to the different internal fixation. There was no significant difference in gender, age, affected side, body mass index, cause of injury, smoking history, alcohol abuse history, Pauwels angle, Garden classification, AO/Orthopaedic Trauma Association (AO/OTA) classification, and time from injury to operation between the two groups (P>0.05). The operation time, incision length, intraoperative blood loss, extra assisted reduction procedures (Kirschner wire prying reduction or open reduction), hospitalization stay, and early complications were recorded and compared between the two groups. Garden index and Haidukewych score were used to evaluate fracture reduction. Fracture healing time, lateral thigh irritation, time of partial or total weight-bearing postoperatively, shortening length and degree of femoral neck, change of caput-collum-diaphysis (CCD) angle (the difference of CCD angle between immediate after operation and last follow-up), incidence of osteonecrosis of femoral head and revision surgery were recorded and compared between the two groups. Hip joint function were evaluated by Harris score.ResultsThe operation time of FNS group was significantly shorter than ITCS group, and the incision length was significantly longer than ITCS group (P<0.05). There was no significant difference in intraoperative blood loss, assisted reduction, Garden index, Haidukewych score, and hospitalization stay between the two groups (P>0.05). All the incisions healed by first intention. There were 2 deep vein thrombosis in the FNS group and 1 pulmonary infection and 1 deep vein thrombosis in the ITCS group. No significant difference was found in the incidence of early postoperative complications (7.1% vs. 6.5%) between the two groups (P=1.000). Patients in both groups were followed up 3-14 months, and there was no significant difference in follow-up time between the two groups (t=–0.553, P=0.582). The fracture healing time, Harris score, and the partial weight-bearing time after operation of the FNS group were significantly better than those of the ITCS group (P<0.05). However, there was no significant difference in total weight-bearing time between the two groups (Z=–1.298, P=0.194). No lateral thigh irritation was found in the FNS group, while 10 patients in the ITCS group had lateral thigh irritation, and the incidence between the two groups (0 vs. 32.3%) was significant (P=0.001). At last follow-up, the shortening length and degree of femoral neck and the change of CCD angle in FNS group were significantly less than those in ITCS group (P<0.05). There was no patient with osteonecrosis of femoral head or reoperation in the FNS group, while 4 patients in the ITCS group underwent reoperation (including 2 cases of osteonecrosis of the femoral head). However, the incidences (0 vs. 6.5%; 0 vs. 12.9%) between the two groups were not significant (P=0.493; P=0.114).ConclusionUsing FNS to treat Pauwels type Ⅲ femoral neck fracture is simple as well as able to reduce the shortening of the femoral neck and the change of the CCD angle. Also, FNS is conducive to the recovery of hip joint function, which should be considered as a new choice for the treatment of young femoral neck fracture patients.

    Release date:2021-09-28 03:00 Export PDF Favorites Scan
  • Application of three-dimensional printing technology for closed reduction and percutaneous cannulated screws fixation of displaced intraarticular calcaneus fractures

    Objective To evaluate the effectiveness of three-dimensional (3-D) printing assisting minimally invasive for intraarticular calcaneal fractures with percutaneous poking reduction and cannulate screw fixation. Methods A retrospective analysis was performed of the 19 patients (19 feet) with intraarticular calcaneal fracture who had been treated between March 2015 and May 2016. There were 13 males and 6 females with an average age of 38.2 years (range, 24-73 years). There were 3 open fractures and 16 closed fractures. By Sanders classification, 12 cases were type Ⅱ, 7 cases were type Ⅲ. By Essex-Lopresti classification, 13 cases were tongue type, 6 cases were joint-depression type. The time from injury to surgery was 1-10 days (mean, 4.7 days). A thin slice CT scan was taken of bilateral calcaneus in patients. By using the mirror imaging technique, the contralateral mirror image and the affected side calcaneus model were printed according to 1∶1 ratio. The displacement of fracture block was observed and contrasted, and the poking reduction was simulated. Calcaneal fracture was treated by percutaneous minimally invasive poking reduction and cannulate screw fixation. The Böhler angle and Gissane angle at immediate after operation and last follow-up was measured on X-ray films, and compared with preoperative measurement. The functional recovery was evaluated by American Orthopaedic Foot and Ankle Society (AOFAS) scores. Results The operation time was 25-70 minutes (mean, 45 minutes). The intraoperative blood loss was 10-40 mL (mean, 14.5 mL). All the incisions healed by first intention and had no relevant postoperative complications such as skin necrosis, nail tract infection, and osteomyelitis. All the patients were followed up 12-25 months (mean, 14.6 months). All patients obtained fracture healing, and the fracture healing time was 8-14 weeks (mean, 10.3 weeks). No screw withdrawal or breakage occurred during follow-up; only 1 patient with Sanders type Ⅱ fracture, whose calcaneus height was partially lost at 6 weeks after operation, the other patients had no reduction loss and fracture displacement, and no traumatic arthritis occurred. The Böhler angle and Gissane angle at immediate after operation and last follow-up were significantly improved when compared with preoperative ones (P<0.05), but there was no significant difference between at immediate after operation and last follow-up (P>0.05). The AOFAS score was 76-100 (mean, 88.2), and the results were excellent in 10 feet, good in 7, and fair in 2, the excellent and good rate was 89.5%. Conclusion 3-D printing assisting minimally invasive for intraarticular calcaneal fractures with percutaneous poking reduction and cannulate screw fixation can reduce the surgical trauma, improve the quality of reduction and fixation, and make the operation more safe, accurate, and individualized.

    Release date:2017-11-09 10:16 Export PDF Favorites Scan
  • TiRobot-assisted percutaneous sacroiliac cannulated screw fixation for posterior pelvic ring injury with sacral variations

    ObjectiveTo investigate the effectiveness of TiRobot-assisted percutaneous sacroiliac cannulated screw fixation in the treatment of posterior pelvic ring injuries with sacral variations, and to evaluate its feasibility and safety. Methods The clinical data of 7 patients with Tile type C pelvic fractures and sacral variations treated with TiRobot-assisted percutaneous sacroiliac cannulated screw fixation between January 2020 and June 2021 were retrospectively analyzed. There were 5 males and 2 females with an average age of 36 years (range, 17-56 years). The causes of injury were traffic accident in 4 cases and falling from height in 3 cases. According to Tile classification of pelvic fractures, there were 1 case of type C1.1, 1 case of type C1.2, and 5 cases of type C1.3; according to Denis classification of sacral fractures, there were 3 cases of zone Ⅰ and 4 cases of zone Ⅱ; sacral deformities included 3 cases of lumbar sacralization, 2 cases of sacral lumbarization, and 2 cases of accessory auricular surface of the sacrum. The time from injury to operation ranged from 2 to 7 days, with an average of 4.6 days. The implantation time of each screw, the fluoroscopy times of each guide pin, the quality of fracture reduction (according to Matta score), the excellent and good rate of screw position, the healing time of fracture, and the incidence of complications were recorded, and the effectiveness was evaluated by Majeed score. Results A total of 13 screws were implanted during the operation, the implantation time of each screw was 10-23 minutes, with an average of 18.2 minutes; the position of the guide pin was good, and no guide pin was adjusted, the fluoroscopy times of each guide pin were 3-7 times, with a median of 4 times. Postoperative imaging data at 3 days showed that the position of sacroiliac screw implantation was evaluated as excellent. No complication such as incision infection or vascular nerve injury occurred, and no adverse events related to robotic devices occurred. At 3 days after operation, according to Matta score, the quality of fracture reduction was excellent in 6 cases and good in 1 case, and the excellent and good rate was 100%. All the 7 patients were followed up 6-15 months, with an average of 12.4 months. Bone union was achieved in all patients, and the healing time ranged from 18 to 24 weeks, with an average of 21.2 weeks. Majeed score at last follow-up was 81-95, with an average of 91.5; 5 cases were excellent, 2 cases were good, and the excellent and good rate was 100%. ConclusionTiRobot-assisted percutaneous sacroiliac cannulated screw fixation for posterior pelvic ring injury with sacral variation is accurate, safe, minimally invasive, and intelligent, and the effectiveness is satisfactory.

    Release date:2022-08-29 02:38 Export PDF Favorites Scan
  • Clinical application of new three-dimensional honeycomb guide in percutaneous cannulated screw fixation of femoral neck fracture

    Objective To design a new type of three-dimensional honeycomb guide for percutaneous cannulated screw placement in femoral neck fracture and evaluate its effectiveness. Methods The clinical data of 40 patients with femoral neck fracture who met the selection criteria between June 2019 and December 2020 were retrospectively analyzed. According to different intraoperative positioning methods, they were divided into control group (20 cases, free hand positioning screws) and study group (20 cases, new guide assisted positioning screws). There was no significant difference in gender, age, side, cause of injury, Garden classification, and time from injury to operation between the two groups (P>0.05). The operation time, fluoroscopy times, guide needle puncture times, and fracture healing time of the two groups were recorded. The hip function was evaluated by Harris score at last follow-up. At immediate after operation, the following imaging indexes were used to evaluate the accuracy of screw implantation distribution: screw spacing, screw coverage area, distance from screw to cervical cortex, parallelism between screws, and screw to cervical axial deviation. Results All operations were successfully completed, and the guide needle did not penetrate the femoral neck cortex. There was no significant difference in operation time and fluoroscopy times between the two groups (P>0.05); the guide needle puncture times in the study group was significantly less than that in the control group (t=8.209, P=0.000). Imaging detection at immediate after operation showed that the screw spacing and screw coverage area in the study group were significantly greater than those in the control group (P<0.05); the distance from screw to cervical cortex, parallelism between screws, and screw to cervical axial deviation were significantly smaller than those in the control group (P<0.05). All patients were followed up 7-25 months, with an average of 19.3 months. There was no significant difference in follow-up time between the two groups (t=−0.349, P=0.729). There were 2 cases of fracture nonunion in the control group and 1 case in the study group, and the other fractures completely healed. One case of osteonecrosis of the femoral head occurred in the control group. During the follow-up, there was no complication such as vascular and nerve injury, venous thrombosis, screw penetration, withdrawal, breakage, and refracture, etc. There was no significant difference in fracture healing time and Harris score at last follow-up between the two groups (P>0.05). ConclusionThe new three-dimensional honeycomb guide has the advantages of simple structure and convenient use. It can reduce the puncture times of the guide needle and effectively improve the accuracy distribution of cannulated screw implantation.

    Release date:2022-01-27 11:02 Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content