On the basis of Poincare scatter plot and first order difference scatter plot, a novel heart rate variability (HRV) analysis method based on scatter plots of RR intervals and first order difference of RR intervals (namely, RdR) was proposed. The abscissa of the RdR scatter plot, the x-axis, is RR intervals and the ordinate, y-axis, is the difference between successive RR intervals. The RdR scatter plot includes the information of RR intervals and the difference between successive RR intervals, which captures more HRV information. By RdR scatter plot analysis of some records of MIT-BIH arrhythmias database, we found that the scatter plot of uncoupled premature ventricular contraction (PVC), coupled ventricular bigeminy and ventricular trigeminy PVC had specific graphic characteristics. The RdR scatter plot method has higher detecting performance than the Poincare scatter plot method, and simpler and more intuitive than the first order difference method.
Objective To explore the hemodynamic assessment after radical surgery in children with tetralogy of Fallot (TOF) by both echocardiography and Mostcare monitor. Methods Clinical data of 63 children with TOF who underwent radical surgery in our hospital from February 2016 to June 2018 were retrospectively analyzed, including 34 males and 29 females, aged 6-24 (9.82±5.77) months. There were 19 patients undergoing transannular patch reconstruction of the right ventricular outflow tract (a transannular patch group) while 44 patients retained the pulmonary valve annulus (a non-transannular patch group) . The echocardiography and Mostcare monitor parameters were recorded and brain natriuretic peptide was tested at the time points of 0, 8, 12, 24 and 48 hours after operation (T 0, T 1, T 2, T 4) to analyze their correlations and the change trend at different time points after radical surgery. Results The left ventricular ejection fraction at T 1 (43.49%±3.82%) was lower than that at T 0 (48.29%±4.55%), T 2 (45.83%±3.69%), T 3 (53.76%±4.43%) and T 4 (60.54%±3.23%, P<0.05). The cardiac index at T 1 (1.85±0.35 L·min−1·m−2) was lower than that at T 0 (2.11±0.38 L·min−1·m−2), T 2 (2.07±0.36 L·min−1·m−2), T 3 (2.42±0.37 L·min−1·m−2) and T 4 (2.82±0.42 L·min−1·m−2, P<0.05). The cardiac circulation efficiency at T1 (0.19±0.05) was lower than that at T 0 (0.22±0.06), T 2 (0.22±0.05), T 3 (0.28±0.06) and T 4 (0.34±0.06, P<0.05). The right ventricular two-chambers view fraction area change at T 1 (23.17%±3.11%) was lower than that at T 0 (25.81%±3.74%), T 2 (25.38%±3.43%), T 3 (30.60%±4.50%) and T 4 (36.94%±5.85%, P<0.05). The pulse pressure variability was the highest at T 0 (18.76%±3.58%), followed by T 1 (14.81%±3.32%), T 2 (12.44%±2.94%), T 3 (10.39%±2.96%) and T 4 (9.18%±1.92%, P<0.05). The blood brain natriuretic peptide was higher at T 1 (846.67±362.95 pg/ml) than that at T 0 (42.60±18.06 pg/ml), T 2 (730.95±351.09 pg/ml), T 3 (510.98±290.39 pg/ml) and T 4 (364.41±243.56 pg/ml, P<0.05). There was no significant difference in left ventricular ejection fraction, cardiac circulation efficiency and heart index between the two groups (P>0.05). The right ventricular two-chambers view fraction area change of the transannular patch group was significantly lower than that of the non-transannular patch group at each time point (P<0.05). The blood brain natriuretic peptide and pulse pressure variability of the transannular patch group were significantly higher than those of the non-transannular patch group (P<0.05). Left ventricular ejection fraction was positively correlated with cardiac index (r=0.637, P=0.001) and cardiac circulation efficiency (r=0.462, P=0.001) while was significantly negatively correlated with blood brain natriuretic peptide (r=–0.419, P=0.001). Conclusion Both methods can accurately reflect the state of cardiac function. Mostcare monitor has a good consistency with echocardiography. Using transannular patch to recontribute right ventricular outflow tract in operation has more influence on right ventricular systolic function. The Mostcare monitor can guide the hemodynamic management after surgery in real time, continuously and accurately.
ObjectiveTo observe the effect of different preoxygenation methods for emergency intubation in severe patients in intensive care unit (ICU). MethodsProspective randomized study was performed in the intensive care unit between June 2013 and January 2014. Forty patients were randomly divided into 4 groups:group A (control group, n=10), group B (bag-valve-mask preoxygenation group, n=10), group C (noninvasive ventilator-mask preoxygenation group, n=10), and group D (invasive ventilator-mask preoxygenation group, n=10). Standardized rapid sequence intubation was performed without preoxygenation in group A; preoxygenation was performed by using a bag-valve-mask rose pulse oxygen saturation (SpO2) to 90% before a rapid sequence intubation in group B; preoxygenation was performed by using noninvasive ventilator through a face mask rose SpO2 to 90% before a rapid sequence intubation in group C; and preoxygenation was performed by using invasive ventilator through a face mask rose SpO2 to 90% before a rapid sequence intubation in group D. We recorded the time when SpO2 was more than or equal to 90% in group B, C, and D, and arterial blood gases and complications were observed. ResultsThere was no significant difference in the basic indexes before preoxygenation among the four groups (P>0.05). The time of the patients in group D and C was significantly lower than that of group B. The arterial oxygen saturation (SaO2) and arterial oxygen partial pressure (PaO2) in the group C and D were higher than those in group B after preoxygenation (P<0.05). After intubation, SpO2 in group B, C and D was significantly higher than that in group A (P<0.05). At the same time, SpO2 in group C and D was higher than that in group B (P<0.05); PaO2 and SaO2 in group C and D were higher than in those in group A and B (P<0.05); SaO2 in group D was higher than that in group B (P<0.05). The incidence of abdominal distension in group D was significantly lower than that of group B and C (P<0.05). ConclusionFor emergency tracheal intubation in critically ill patients in the ICU, preoxygenation is more effective than the rapid sequence intubation without preoxygenation in improving oxygenation indicators. Invasive ventilator-mask preoxygenation efficacy and safety are superior to other methods.
The hospital information structure, which is made up of various medical business systems, is suffering from the problems of the "information isolated island". Medical business systems in the hospital are mutually isomerous and difficult to become a whole. How to realize the internal barrier-free interaction of the patients effective medical information in the hospital and further to complete the area sharing of patients longitudinal diagnosis and treatment information has become a question having to be solved urgently in the process of healthcare informatization. Based on the HL7 standard, this paper refers to the IHE technical framework, expounds the overall structure of the interaction in the hospital internal and area sharing of medical information with the medical information exchange platform. The paper also gives the details of the whole process of the complete display of the discrete patient health information using Portal technology, which is saved in the business systems in different hospitals. It interacts internally through the information exchange platform and at last stores the information in the regional cinical data repository (CDR).
Objective To observe the functional state of the optic nerve and discover the injury of visual pathway function in time under general ane sthesia. The flash visual evoked potential (F-VEP) was used to monitor visual function during orbital surgery. Methods A total of 252 out of 282 patients undergoing orbital surgery under general anesthesia were successfully monitored by F-VEP during the surgery. All patients were monitored by this method under the following conditions:consious state before operation, under general anaesthesia, during and after dissection of orbital tumor and at the end of operation. Results ①There was no significant difference of wave amplitude and latency under general anesthesia and consciousness condition. ②The amplitude and latency of F-VEP were normal in the orbital surgery withou toptic nerve injury. ③Pulling and oppression of optic nerve could cause temporary wave loss, but the wave recovered after removal of the pull and oppression. ④ The wave loss of F-VEP would occur immedicately when optic nerve was severe injured and its blood supply was deficient. Since the application of the visual function monitoring, 24 cases were treated in time during disturbance of visual function and no patient has unexpected visual loss during orbital surgery. Conclusion The intraoperative monitoring of F-VEP during orbital surgery can decrease the proportion of permanent visual loss caused by orbit al surgery, and help the surgical procedures go to function-anatomy stage from experience-anatomy stage. (Chin J Ocul Fundus Dis, 2001,17:260-263)
With nearly four decades of progress in healthcare-associated infection prevention and control in China, the national quality control efforts in this field have been ongoing for the past ten years, advancing rapidly with significant achievements. Over the last decade, the team of infection control professionals involved in quality management and control in China has consistently expanded, accompanied by an enhancement of their skills. Management capabilities have steadily grown, and operational mechanisms have been continuously refined. As public hospitals transition into a new phase of high-quality development, emphasizing refined management models and intrinsic development of medical quality, it becomes crucial to further fortify the foundation and foster innovation in infection control work to ensure quality. This article provides an overview of the establishment and implementation of the National Center for Quality Control of Infection Prevention and Control, examines the current shortcomings and challenges in the field, and collectively explores the positioning and direction of the development of quality control efforts for infection prevention and control in China.
Objective To explore the colonization of Klebsiella pneumoniae in the intensive care unit of our hospital and analyze the risk factors. Methods A total of 226 patients were actively screened in the surgical intensive care unit and neurosurgery intensive care unit from June to December 2020 in the hospital, and their clinical data were retrospectively analyzed. Results Totally, 87 strains of Klebsiella pneumoniae were screened out, 69 strains were carbapenem-resistant Klebsiella pneumoniae (CRKP), and the resistant genotype was mainly KPC genotype (79.6%). The resistance rates of meropenem were 75.0% and 77.4%, respectively. Age and pulmonary infection before admission are risk factors for CRKP colonization, while pulmonary infection before admission is an independent risk factor for CRKP colonization. Conclusions Both the CRKP colonization rate of patients and the rate of resistance to carbapenem antimicrobials are relatively high in the intensive care unit of our hospital. Pulmonary infection before admission is an independent risk factor for CRKP colonization.
With the establishment and development of regional healthcare big data platforms, regional healthcare big data is playing an increasingly important role in health policy program evaluations. Regional healthcare big data is usually structured hierarchically. Traditional statistical models have limitations in analyzing hierarchical data, and multilevel models are powerful statistical analysis tools for processing hierarchical data. This method has frequently been used by healthcare researchers overseas, however, it lacks application in China. This paper aimed to introduce the multilevel model and several common application scenarios in medicine policy evaluations. We expected to provide a methodological framework for medicine policy evaluation using regional healthcare big data or hierarchical data.
摘要:目的: 通过分析地市级急救中心院前急救资料,探讨ICD10疾病分类方法在院前急救中的实用性。 方法 :回顾性分析2007年1~12月份自贡市急救中心出诊的全部有效急救患者的急诊诊断以及随访诊断,使用ICD10编码进行归类,比较疾病性别构成比。 结果 :全年院前急救4109例,排5位的疾病分别为损伤、中毒和外因的某些其他后果(484%)、循环系统疾病(170%)、消化系统疾病(81%)、呼吸系统疾病(64%)、精神和行为障碍(52%),损伤、中毒和外因的某些其他后果、循环系统疾病以及消化系统疾病出诊量男性多于女性(P<005),耳和乳突疾病以及妊娠、分娩和产褥期疾病出诊量女性多于男性(P<005)。 结论 :采用ICD10标准对院前急救病谱分类有进一步探讨的价值。Abstract: Objective: To investigate the value of ICD10 in prehospital care by the analysis of cases in Zigong Urgent Rescue Center. Methods : All cases of prehospital care during the year of 2007 were studied, whose emergency Diagnoses and followup diagnoses were recorded, and they were classified by international classification of diseases 10th revision (ICD10). The gender composition ratio of diseases was analyzed. Results : Four thousand one hundred and nine cases of prehospital care in 2007 were included. Topfive diseases were injury, poisoning and certain other consequences of external causes (484%), diseases of the circulatory system (170%), diseases of the digestive system (81%), diseases of the respiratory system (64%), and mental and behavioral disorders (52%) respectively. The amout of the male prehospital cases was more that of than the female’s in the diseases of injury, poisoning and certain other consequences of external causes, diseases of the circulatory system, diseases of the digestive system (P<005); the amount of the female prehospital cases was more than that of the male’s in the diseases of the ear and mastoid process, pregnancy, childbirth and the puerperium (P<005). Conclusion : Further research on the spectrum of diseases classified by ICD10 is valuable.