west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "coil" 15 results
  • Application of CT-guided microcoil localization in single utility port video-assisted thoracoscopic surgery for small pulmonary nodules (diameter≤15 mm): A retrospective cohort study

    ObjectiveTo explore the application value of CT-guided microcoil localization in pulmonary nodule (diameter≤15 mm) surgery.MethodsThe clinical data of 175 patients with pulmonary nodules who underwent single utility port video-assisted thoracoscopic surgery at Nanjing Drum Tower Hospital from August 2018 to December 2019 were retrospectively analyzed. According to whether CT-guided coil localization was performed before operation, they were divided into a locating group and a non-locating group. There were 84 patients (34 males, 50 females, aged 57.8±8.8 years) in the locating group and 91 patients (46 males, 45 females, aged 57.6±10.8 years) in the non-locating group. The localization success rate, localization time, incidence of complications, surgical and postoperative conditions were analyzed between the two groups.ResultsAll 84 patients in the locating group were successfully located, and localization time was 19.0±3.6 minutes. Among them, 19 (22.6%) patients had a small pneumothorax, 4 (4.8%) pulmonary hemorrhage and 2 (2.4%) coil shift; 6 (7.1%) patients had mild pain, 3 (3.6%) moderate pain and 1 (1.2%) severe pain. Sex (P=0.181), age (P=0.673), nodule location (P=0.167), nature of lesion (P=0.244), rate of conversion to thoracotomy (P=0.414), rate of disposable resection of nodules (P=0.251) and postoperative hospital stay (P=0.207) were similar between the two groups. There were significant differences in nodule size (P<0.001), nature of nodule (P<0.001), the shortest distance from nodule to pleura (P<0.001), operation time (P<0.001), lung volume by wedge resection (P=0.031), number of staplers (P<0.001) and total hospitalization costs (P<0.001) between the two groups.ConclusionCT-guided microcoil localization has the characteristics of high success rate, and is simple, practicable, effective, safe and minimally invasive. Preoperative CT-guided microcoil localization has important clinical application value for small pulmonary nodules, especially those with small size, deep location and less solid components. It can effectively shorten the operation time, reduce surgical trauma and lower hospitalization costs, which is a preoperative localization technique worthy of popularization.

    Release date:2022-01-21 01:31 Export PDF Favorites Scan
  • Effectiveness and Safety of Power Chain versus Nickel Titanium Coil Springs in Closing Dental Extraction Space: A Meta-Analysis

    Objective To systematically review the effectiveness and safety of power chain vs. nickel titanium coil springs in closing dental extraction space. Methods Databases including PubMed, EMbase, The Cochrane Library, Chinese Biomedicine Literature Database, Chinese Scientific Journals Full-text Database, and Chinese Journal Full-text Database were searched to collect the randomized controlled trials (RCTs) on comparing power chain with nickel titanium coil springs published before February 2012. Two reviewers independently screened literature, extracted data and assessed the quality of the included studies. Then meta-analysis was conducted using RevMan 5.0 software. Results A total of 4 RCTs involving 122 patients were included. The results of meta-analyses showed that there was a significant difference in the rate of space closure between the two groups (MD=0.30 mm per month, 95%CI 0.17 to 0.44, Plt;0.000 1); The results of subgroup analyses indicated that, both high-quality trials (MD=0.20, 95%CI 0.07 to 0.34, P=0.003) and low quality trials (MD=0.40, 95%CI 0.30 to 0.50, Plt;0.000 01) showed no significant difference in the rate of space closure. Conclusion Current clinical evidence indicates nickel titanium coil spring is superior to power chain in the rate of space closure, but its long-term effect still needs to be proved by more large-scale RCTs.

    Release date:2016-09-07 10:58 Export PDF Favorites Scan
  • Pulmonary nodules localization via microcoil and anchor with scaled suture guided by CT in thoracoscopic surgery: A retrospective cohort study

    ObjectiveTo compare the effectiveness and safety of preoperative lung localization by microcoil and anchor with scaled suture.MethodsA total of 286 patients underwent CT-guided puncture localization consecutively between October 2019 and December 2020 in our hospital. According to the different methods of localization, they were divided into a microcoil group (n=139, including 49 males and 90 females, aged 57.92±10.51 years) and an anchor group (n=147, including 53 males and 94 females, aged 56.68±11.31 years). The clinical data of the patients were compared.ResultsA total of 173 nodules were localized in the microcoil group, and 169 nodules in the anchor group. The localization success rate was similar in the two groups. However, the anchor group was significantly better than the microcoil group in the localization time (8.15±2.55 min vs. 9.53±3.08 min, P=0.001), the pathological receiving time (30.46±14.41 min vs. 34.96±19.75 min, P=0.029), and the hemoptysis rate (10.7% vs. 30.1%, P=0.001), but the pneumothorax rate was higher in the anchor group (21.3% vs. 11.0%, P=0.006).ConclusionPreoperative localization of small pulmonary nodules using anchor with suture is practical and safe. Due to its simplicity and convenience, it is worth of promotion in the clinic.

    Release date:2022-01-21 01:31 Export PDF Favorites Scan
  • An radio frequency coil design for rat spinal magnetic resonance imaging at 9.4 T

    For rat spinal magnetic resonance imaging (MRI) experiments, due to the lower main magnetic field strength, shallower detected depth and poor spatial compatibility of the traditional radio frequency (RF) coil, the image signal-to-noise ratio (SNR) of rat spinal was rather lower. In this paper, a RF coil for rat spinal MRI at 9.4 T was developed to improve the image quality and at the same time to avoid the space limitation while scanning in special conditions (cardiac catheterization, etc.). In this article, open birdcage structure was built and magnetic field distribution was calculated. The phantom and rat spine MRI imaging were experimented at 9.4 T to verify the advantage of the coil in rat spine MRI application.

    Release date:2019-02-18 03:16 Export PDF Favorites Scan
  • Application of preoperative computed tomography-guided embolization coil localization of pulmonary nodules in thoracoscopic pulmonectomy: A randomized controlled trial

    Objective To explore the diagnostic and treatment value of computed tomography (CT)-guided embolization coil localization of pulmonary nodules accurately resected under the thoracoscope. Methods Between October 2015 and October 2016, 40 patients with undiagnosed nodules of 15 mm or less were randomly divided into a no localization group (n=20, 11 males and 9 females with an average age of 60.50±8.27 years) or preoperative coil localization group (n=20, 12 males and 8 females with an average age of 61.35±8.47 years). Coils were placed with the distal end deep to the nodule and the superficial end coiled on the visceral pleural surface with subsequent visualization by video-assisted thoracoscopic (VATS). Nodules were removed by VATS wedge excision using endo staplers. The tissue was sent for rapid pathological examination, and the pulmonary nodules with definitive pathology found at the first time could be defined as the exact excision. Results The age, sex, forced expiratory volume in the first second of expiration, nodule size/depth were similar between two groups. The coil group had a higher rate of accurate resection (100.00% vs. 70.00%, P=0.008), less operation time to nodule excision (35.65±3.38 minvs. 44.38±11.53 min,P=0.003), and reduced stapler firings (3.25±0.85vs. 4.44±1.26,P=0.002) with no difference in total costs. Conclusion Preoperative CT-guided coil localization increases the rate of accurate resection.

    Release date:2017-11-01 01:56 Export PDF Favorites Scan
  • Development of RF Coil of Permanent Magnet Mini-magnetic Resonance Imager and Mouse Imaging Experiments

    In the development of radio frequency (RF) coils for better quality of the mini-type permanent magnetic resonance imager for using in the small animal imaging, the solenoid RF coil has a special advantage for permanent magnetic system based on analyses of various types of RF coils. However, it is not satisfied for imaging if the RF coils are directly used. By theoretical analyses of the magnetic field properties produced from the solenoid coil, the research direction was determined by careful studies to raise further the uniformity of the magnetic field coil, receiving coil sensitivity for signals and signal-to-noise ratio (SNR). The method had certain advantages and avoided some shortcomings of the other different coil types, such as, birdcage coil, saddle shaped coil and phased array coil by using the alloy materials (from our own patent). The RF coils were designed, developed and made for keeled applicable to permanent magnet-type magnetic resonance imager, multi-coil combination-type, single-channel overall RF receiving coil, and applied for a patent. Mounted on three instruments (25 mm aperture, with main magnetic field strength of 0.5 T or 1.5 T, and 50 mm aperture, with main magnetic field strength of 0.48 T), we performed experiments with mice, rats, and nude mice bearing tumors. The experimental results indicated that the RF receiving coil was fully applicable to the permanent magnet-type imaging system.

    Release date: Export PDF Favorites Scan
  • CT-guided Hook-wire versus microcoil localization in the pulmonary nodules surgery: A systematic review and meta-analysis

    ObjectiveTo systematically evaluate the application effect of CT-guided Hook-wire localization and CT-guided microcoil localization in pulmonary nodules surgery. MethodsThe literatures on the comparison between CT-guided Hook-wire localization and CT-guided microcoil localization for pulmonary nodules were searched in PubMed, EMbase, The Cochrane Library, Web of Science, Wanfang, VIP and CNKI databases from the inception to October 2021. Review Manager (version 5.4) software was used for meta-analysis. The Newcastle-Ottawa Scale (NOS) was used to evaluate the quality of studies.ResultsA total of 10 retrospective cohort studies were included, with 1 117 patients including 473 patients in the CT-guided Hook-wire localization group and 644 patients in the CT-guided microcoil localization group. The quality of the studies was high with NOS scores>6 points. The result of meta-analysis showed that the difference in the localization operation time (MD=0.14, 95%CI −3.43 to 3.71, P=0.940) between the two groups was not statistically significant. However, the localization success rate of the Hook-wire group was superior to the microcoil group (OR=0.35, 95%CI 0.17 to 0.72, P=0.005). In addition, in comparison with Hook-wire localization, the microcoil localization could reduce the dislocation rate (OR=4.33, 95%CI 2.07 to 9.08, P<0.001), the incidence of pneumothorax (OR=1.62, 95%CI 1.12 to 2.33, P=0.010) and pulmonary hemorrhage (OR=1.64, 95%CI 1.07 to 2.51, P=0.020). ConclusionAlthough Hook-wire localization is slightly better than microcoil localization in the aspect of the success rate of pulmonary nodule localization, microcoil localization has an obvious advantage compared with Hook-wire localization in terms of controlling the incidence of dislocation, pneumothorax and pulmonary hemorrhage. Therefore, from a comprehensive perspective, this study believes that CT-guided microcoil localization is a preoperative localization method worthy of further promotion.

    Release date:2023-06-13 11:24 Export PDF Favorites Scan
  • Deep transcranial magnetic stimulation coil design and multi-objective slime mould algorithm

    The therapeutic effects of transcranial magnetic stimulation (TMS) are closely related to the structure of the stimulation coil. Based on this, this study designed an A-word coil and proposed a multi-strategy fusion multi-objective slime mould algorithm (MSSMA) aimed at optimizing the stimulation depth, focality, and intensity of the coil. MSSMA significantly improved the convergence and distribution of the algorithm by integrating a dual-elite guiding mechanism, a hyperbolic tangent control strategy, and a hybrid polynomial mutation strategy. Furthermore, compared with other stimulation coils, the novel coil optimized by the MSSMA demonstrates superior performance in terms of stimulation depth. To verify the optimization effects, a magnetic field measurement system was established, and a comparison of the measurement data with simulation data confirmed that the proposed algorithm could effectively optimize coil performance. In summary, this study provides a new approach for deep TMS, and the proposed algorithm holds significant reference value for multi-objective engineering optimization problems.

    Release date:2025-08-19 11:47 Export PDF Favorites Scan
  • Predicting risk of severe elastic recoil after percutaneous transluminal angioplasty in femoropopliteal artery disease: based on intravascular ultrasound analysis

    ObjectiveTo identify risk factors for severe elastic recoil after percutaneous transluminal angioplasty (PTA) in the femoropopliteal artery disease based on intravascular ultrasound (IVUS) imaging and to develop a risk prediction model. MethodsA retrospective analysis was conducted on the clinical data from the patients with femoropopliteal artery disease treated at the First Affiliated Hospital of Chongqing Medical University from September 2020 to February 2022. Based on the IVUS images, a multivariate logistic regression analysis was conducted to identify the risk factors for severe elastic recoil in the patients with femoropopliteal artery disease after PTA. A nomogram prediction model was established to predict the occurrence of severe elastic recoil, and the area under receiver operating characteristic curve (AUC) was used to evaluate its ability to distinguish the occurrence of severe elastic recoil, which was validated using a calibration curve. ResultsA total of 34 patients with femoropopliteal artery disease who received PTA treatment were enrolled. Of the 803 vessel slices were analyzed, 451 (56.16%) demonstrated severe elastic recoil on IVUS imaging. The multivariate logistic regression analysis showed that the increased plaque burden, luminal eccentric index, external elastic membrane remodeling index, and the external elastic membrane-balloon area ratio were the risk factors for the occurrence of severe elastic recoil (P<0.05). The AUC of the nomogram prediction model based on these risk factors exhibited moderate discrimination [AUC (95%CI)=0.775 (0.732, 0.818)]. The predicted probability of the nomogram model for severe elastic recoil was in a good agreement with the actual probability (P=0.862). ConclusionThe severe elastic recoil prediction model developed in this study, based on IVUS imaging data, can effectively identify high-risk factors for severe elastic recoil after PTA in patients with femoropopliteal artery disease, demonstrating a moderate predictive discrimination capability.

    Release date:2025-04-21 01:06 Export PDF Favorites Scan
  • Study on the relaxing effect of salbutamol combined with Y-27632 on porcine airway smooth muscle

    Objective To explore the effect of salbutamol combined with Rho associated coiled-coil forming protein kinase (ROCK) inhibitor Y-27632 on airway smooth muscle and to find a new way for drug treatment of asthma. Methods Pig tracheal smooth muscle tissue strips were prepared, and after treatment they were divided into an electrical stimulation group (Fmax, 50%Fmax) and a blank group. The smooth muscle tissue strips were quickly frozen to determine the expression level of Rock-Ⅱ and the phosphorylation level of MLC20. The Fmax and 50%Fmax electrical stimulation groups were divided into a blank group, a salbutamol group, a Y-27632 group, and a salbutamol combined with Y-27632 group according to different intervention drugs. The relaxation of smooth muscle strips was observed. Results In the blank group, 50%Fmax group and Fmax group, the expression level of Rock-Ⅱ and the phosphorylation of MLC20 in smooth muscle tissue showed an increasing trend, with statistically significant differences (P<0.05). In the 4 subgroups of the 50%Fmax group intervention with different drugs (blank group, salbutamol group, Y-27632 group, salbutamol plus Y-27632 group), the diastolic ratio smooth muscle tissue strips showed an increasing trend. When the time reaches 10 min, the diastolic ratios were 0.7%, 2.5%, 6.0%, and 15.0%. the diastolic ratios were 1.8%, 4.5%, 7.5%, and 21.0% at the time of 20 min. the diastolic ratios were 1.9%, 7.5%, 7.9% and 22.0% at the time of 40 min. the diastolic ratios were 2.0%, 8.0%, 8.8%, and 22.5% at the time of 60 min. In the four subgroups of the Fmax electrical stimulation group, the relaxation ratio of smooth muscle tissue strips also showed an increasing trend. When the time reaches 10 min, the diastolic ratios were 1.0%, 3.0%, 7.0%, and 17.0%. the diastolic ratios were 2.6%, 5.5%, 9.0%, and 24.0% at the time of 20 min. the diastolic ratios were 2.8%, 9.0%, 9.5%, and 27.5% at the time of 40 min. diastolic ratios were 2.9%, 10.5%, 10.5%, and 28.0% at the time of 60 min. The analysis of difference between groups showed that at the same time, the diastolic ratio of smooth muscle in salbutamol combined with Y-27632 group was significantly higher than that in salbutamol alone group and Y-27632 group (P<0.05). In addition, the smooth muscle diastolic ratio of combined intervention was also better than the the mathematical sum effect of both single drug intervention (P<0.05). Conclusions The contractility and intensity of smooth muscle are positively correlated with the expression level of ROCK and the phosphorylation level of MLC20. Salbutamol combined with Y-27632 can enhance the relaxation of porcine airway smooth muscle, which may have a synergistic effect.

    Release date: Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content