find Keyword "detection" 99 results
  • Research on pulmonary nodule recognition algorithm based on micro-variation amplification

    Objective To develop an innovative recognition algorithm that aids physicians in the identification of pulmonary nodules. MethodsPatients with pulmonary nodules who underwent thoracoscopic surgery at the Department of Thoracic Surgery, Affiliated Drum Tower Hospital of Nanjing University Medical School in December 2023, were enrolled in the study. Chest surface exploration data were collected at a rate of 60 frames per second and a resolution of 1 920×1 080. Frame images were saved at regular intervals for subsequent block processing. An algorithm database for lung nodule recognition was developed using the collected data. ResultsA total of 16 patients were enrolled, including 9 males and 7 females, with an average age of (54.9±14.9) years. In the optimized multi-topology convolutional network model, the test results demonstrated an accuracy rate of 94.39% for recognition tasks. Furthermore, the integration of micro-variation amplification technology into the convolutional network model enhanced the accuracy of lung nodule identification to 96.90%. A comprehensive evaluation of the performance of these two models yielded an overall recognition accuracy of 95.59%. Based on these findings, we conclude that the proposed network model is well-suited for the task of lung nodule recognition, with the convolutional network incorporating micro-variation amplification technology exhibiting superior accuracy. Conclusion Compared to traditional methods, our proposed technique significantly enhances the accuracy of lung nodule identification and localization, aiding surgeons in locating lung nodules during thoracoscopic surgery.

    Release date:2025-02-28 06:45 Export PDF Favorites Scan
  • Research on the detection algorithm of electrocardiogram characteristic wave based on energy segmentation and stationary wavelet transform

    The detection of electrocardiogram (ECG) characteristic wave is the basis of cardiovascular disease analysis and heart rate variability analysis. In order to solve the problems of low detection accuracy and poor real-time performance of ECG signal in the state of motion, this paper proposes a detection algorithm based on segmentation energy and stationary wavelet transform (SWT). Firstly, the energy of ECG signal is calculated by segmenting, and the energy candidate peak is obtained after moving average to detect QRS complex. Secondly, the QRS amplitude is set to zero and the fifth component of SWT is used to locate P wave and T wave. The experimental results show that compared with other algorithms, the algorithm in this paper has high accuracy in detecting QRS complex in different motion states. It only takes 0.22 s to detect QSR complex of a 30-minute ECG record, and the real-time performance is improved obviously. On the basis of QRS complex detection, the accuracy of P wave and T wave detection is higher than 95%. The results show that this method can improve the efficiency of ECG signal detection, and provide a new method for real-time ECG signal classification and cardiovascular disease diagnosis.

    Release date:2022-02-21 01:13 Export PDF Favorites Scan
  • Automatic epileptic seizure detection algorithm based on dual density dual tree complex wavelet transform

    It is very important for epilepsy treatment to distinguish epileptic seizure and non-seizure. In this study, an automatic seizure detection algorithm based on dual density dual tree complex wavelet transform (DD-DT CWT) for intracranial electroencephalogram (iEEG) was proposed. The experimental data were collected from 15 719 competition data set up by the National Institutes of Health (NINDS) in Kaggle. The processed database consisted of 55 023 seizure epochs and 501 990 non-seizure epochs. Each epoch was 1 second long and contained 174 sampling points. Firstly, the signal was resampled. Then, DD-DT CWT was used for EEG signal processing. Four kinds of features include wavelet entropy, variance, energy and mean value were extracted from the signal. Finally, these features were sent to least squares-support vector machine (LS-SVM) for learning and classification. The appropriate decomposition level was selected by comparing the experimental results under different wavelet decomposition levels. The experimental results showed that the features selected in this paper were different between seizure and non-seizure. Among the eight patients, the average accuracy of three-level decomposition classification was 91.98%, the sensitivity was 90.15%, and the specificity was 93.81%. The work of this paper shows that our algorithm has excellent performance in the two classification of EEG signals of epileptic patients, and can detect the seizure period automatically and efficiently.

    Release date:2022-02-21 01:13 Export PDF Favorites Scan
  • An endpoint-detection algorithm of surface electromyography insensitive to electrocardiogram interference

    Surface electromyography (sEMG) has been widely used in the study of clinical medicine, rehabilitation medicine, sports, etc., and its endpoints should be detected accurately before analyzing. However, endpoint detection is vulnerable to electrocardiogram (ECG) interference when the sEMG recorders are placed near the heart. In this paper, an endpoint-detection algorithm which is insensitive to ECG interference is proposed. In the algorithm, endpoints of sEMG are detected based on the short-time energy and short-time zero-crossing rates of sEMG. The thresholds of short-time energy and short-time zero-crossing rate are set according to the statistical difference of short-time zero-crossing rate between sEMG and ECG, and the statistical difference of short-time energy between sEMG and the background noise. Experiment results on the sEMG of rectus abdominis muscle demonstrate that the algorithm detects the endpoints of the sEMG with a high accuracy rate of 95.6%.

    Release date:2019-02-18 02:31 Export PDF Favorites Scan
  • A comparative study of nasal and pharyngeal swabs in the diagnosis of coronavirus disease 2019

    ObjectiveTo investigate a more convenient and safe sampling method for viral nucleic acid detection of coronavirus disease 2019.MethodsAn oropharyngeal swab and nasopharyngeal swab were simultaneously taken from 100 patients with coronavirus disease 2019 in a hospital in Wuhan. Then the efficacies of two sampling methods were compared on the positive rates of viral nucleic acid detection.ResultsThe positive rate for SARS-CoV-2 was 54% in oropharyngeal swabs, while 89% positive in nasopharyngeal swabs. There was a significant difference in the detection rate between oropharyngeal swab and nasopharyngeal swab (χ2=3.850 4, P=0.049 7).ConclusionsThe positive rate for nucleic acid testing from nasopharyngeal swabs are significantly better than that from oropharyngeal swabs. Therefore, sampling by nasopharyngeal swabs, rather than oropharyngeal swabs, should be chosen as the preferred virological screening method for patients with coronavirus disease 2019.

    Release date:2020-05-26 09:32 Export PDF Favorites Scan
  • Direct fecal detection ofClostridium difficile in patients with recurrent inflammatory bowel disease

    Objective To explore the application of two methods of direct fecal detection ofClostridium difficilein patients with recurrent inflammatory bowel disease (IBD), including nucleic acid amplification test (NAAT) and enzyme immunoassay (EIA), in order to provide support for hospitals to prevent and control clostridium difficile infection (CDI). Methods Fresh feces of 48 patients with recurrent IBD treated between November 2014 and April 2015 were collected within 48 hours after admission. Anaerobic culture and identification, NAAT and EIA were used to test the same samples. Statistical analysis was performed using Kappa test. Results Among the 48 fecal samples,Clostridium difficilewas negative in 37 and positive in 11 including 2 (4.2%) with toxigenicClostridium difficile characterized as toxin type A+B+. Compared with anaerobic culture and identification, NAAT had a perfect correlation (Kappa=1.00,P<0.05), and EIA had an almost perfect correlation (Kappa=0.89,P<0.05). But EIA toxin test had missed detection of toxigenic samples. Conclusions For patients with recurrent IBD combined with CDI, both NAAT and EIA test may be applied to detctClostridium difficile in feces directly, while NAAT may show a better performance. Samples from highly suspected patients with negative toxin result tested by EIA should be confirmed by other methods such as NAAT.

    Release date:2017-03-27 11:42 Export PDF Favorites Scan
  • Research on the influence of light with different wavelength on the motion behavior of carp robots

    In order to study the effect of light with different wavelengths on the motion behavior of carp robots, phototaxis experiment, anatomical experiment, light control experiment and speed measurement experiment were carried out in this study. Blue, green, yellow and red light with different wavelength were used to conduct phototaxis experiments on carp to observe their movement behavior. By dissecting the skull bones of the carp to determine the appropriate location to carry the light control device, we independently developed a light control carrying device which was suitable for any illumination intensity environment. The experiment of the light-controlled carp robots was carried out. The motion behavior of the carp robot was checked by using computer binocular stereo vision technology. The motion trajectory of the carp robot was tracked and obtained by applying kernel correlation filter (KCF) algorithm. The motion velocity of the carp robot at different wavelengths was calculated according to their motion trajectory. The results showed that carps’ sensitivity to different light changed from strong to weak in the order of blue, red, yellow and green, so that using light with different wavelengths to control the speed of the carp robot has certain laws to follow. A new method to avoid brain damage in carp robots control can be provided in this study.

    Release date:2021-10-22 02:07 Export PDF Favorites Scan
  • Pulmonary nodule detection method based on convolutional neural network

    A method was proposed to detect pulmonary nodules in low-dose computed tomography (CT) images by two-dimensional convolutional neural network under the condition of fine image preprocessing. Firstly, CT image preprocessing was carried out by image clipping, normalization and other algorithms. Then the positive samples were expanded to balance the number of positive and negative samples in convolutional neural network. Finally, the model with the best performance was obtained by training two-dimensional convolutional neural network and constantly optimizing network parameters. The model was evaluated in Lung Nodule Analysis 2016(LUNA16) dataset by means of five-fold cross validation, and each group's average model experiment results were obtained with the final accuracy of 92.3%, sensitivity of 92.1% and specificity of 92.6%.Compared with other existing automatic detection and classification methods for pulmonary nodules, all indexes were improved. Subsequently, the model perturbation experiment was carried out on this basis. The experimental results showed that the model is stable and has certain anti-interference ability, which could effectively identify pulmonary nodules and provide auxiliary diagnostic advice for early screening of lung cancer.

    Release date:2020-02-18 09:21 Export PDF Favorites Scan
  • Efficacy and safety of computer-aided detection(CADe) in colonoscopy for colorectal neoplasia detection: a meta-analysis

    ObjectiveTo systematically evaluate the efficacy and safety of computer-aided detection (CADe) and conventional colonoscopy in identifying colorectal adenomas and polyps. MethodsThe PubMed, Embase, Cochrane Library, Web of Science, WanFang Data, VIP, and CNKI databases were electronically searched to collect randomized controlled trials (RCTs) comparing the effectiveness and safety of CADe assisted colonoscopy and conventional colonoscopy in detecting colorectal tumors from 2014 to April 2023. Two reviewers independently screened the literature, extracted data, and evaluated the risk of bias of the included literature. Meta-analysis was performed by RevMan 5.3 software. ResultsA total of 9 RCTs were included, with a total of 6 393 patients. Compared with conventional colonoscopy, the CADe system significantly improved the adenoma detection rate (ADR) (RR=1.22, 95%CI 1.10 to 1.35, P<0.01) and polyp detection rate (PDR) (RR=1.19, 95%CI 1.04 to 1.36, P=0.01). It also reduced the missed diagnosis rate (AMR) of adenomas (RR=0.48, 95%CI 0.34 to 0.67, P<0.01) and the missed diagnosis rate (PMR) of polyps (RR=0.39, 95%CI 0.25 to 0.59, P<0.01). The PDR of proximal polyps significantly increased, while the PDR of ≤5 mm polyps slightly increased, but the PDR of >10mm and pedunculated polyps significantly decreased. The AMR of the cecum, transverse colon, descending colon, and sigmoid colon was significantly reduced. There was no statistically significant difference in the withdrawal time between the two groups. Conclusion The CADe system can increase the detection rate of adenomas and polyps, and reduce the missed diagnosis rate. The detection rate of polyps is related to their location, size, and shape, while the missed diagnosis rate of adenomas is related to their location.

    Release date:2024-11-12 03:38 Export PDF Favorites Scan
  • Diagnosis of Arteriosclerosis Obliterans of Lower Extremity in Early Stage

    Objective To explore the methods of early diagnosis of arteriosclerosis obliterans of lower extremity (ASOLE). Methods The related literatures on ASOLE detection means adopted clinically were reviewed, and their advantages and disadvantages were compared.Results Asymptomatic ASOLE could be discovered by determination of ankle brachial index (ABI) and toe brachial index (TBI), which was a good index for arterial function assessment of lower extremity. Pulse wave velocity (PWV) was more vulnerable and less sensitive than ABI, and therefore more suitable for screening of a large sample. ASI was an index to assess arterial structure and function, and it had a good correlation with PWV. Flow-mediated dilation (FMD) was a measurement evaluating the function of endothelial cell; Pulse wave measurement was simple, sensitive, and its result was reliable. Color Doppler ultrasonography could localizate the lesion and determine the degree of stenosis at the same time. Multiple-slice CT angiography (MSCTA) was more accurate than color Doppler ultrasonography, but its inherent shortcomings, such as nephrotoxicity of contrast agent, was still need to be resolved. 3D-contrast enhancement magnetic resonance angiography (CEMRA) had little nephrotoxicity, but a combination of other imaging methods was necessary. Microcirculation detections required high consistency of the measurement environment, but they were simple, sensitive and noninvasive, and therefore could be used for screening of ASO. Conclusion Publicity and education of highrisk groups, and reasonable selection of all kinds of detection means, are helpful to improve the early diagnosis of ASOLE.

    Release date:2016-09-08 10:54 Export PDF Favorites Scan