west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "echocardiography" 69 results
  • Real-time Three Dimensional Echocardiography Guided Closure of Atrial Septal Defect through a RightMinithoracotomy in Comparison with Traditional Surgical Repair under Cardiopulmonary Bypass

    Objective To compare surgical results between real-time three dimensional echocardiography(RT-3DE) guided closure of atrial septal defect (ASD) through a right minithoracotomy and traditional surgical repair under cardiopulmonary bypass (CPB). Methods Sixty-four patients with secundum ASD received surgical repair in the First People’s Hospital of Honghe Autonomous Prefecture from April 2009 to April 2012. According to different surgical approach, all the patients were divided into group A and B. In group A, 35 patients underwent traditional ASD repair under CPB including 20males and 15 females with their age of 12-56 (16.4±4.0) years. In group B, 29 patients received real-time RT-3DE guidedASD closure through a right minithoracotomy without CPB, including 20 males and 15 females with their age of 15-50 (18.5±0.2) years. Operation time,postoperative mechanical ventilation time,hospital stay,chest drainage,mortality,morbidity and follow-up outcomes were compared between the 2 groups. Results Operation time (110.47±35.90 minutesvs. 159.32±20.60 minutes),postoperative mechanical ventilation time (10.40±22.30 hours vs. 16.40±12.20 hours),chestdrainage (106.71±85.20 ml vs. 146.70±75.63 ml)and postoperative hospital stay (4.0±1.0 days vs. 7.0±1.0 days)ofgroup B were significantly shorter or less than those of group A. In group A, 1 patient died postoperatively and 7 patientshad postoperative complications. In group B, there was no in-hospital mortality and 3 patients had postoperative complications.Postoperative morbidity of group A was significantly higher than that of group B (20.0% vs. 10.3%,P<0.05) . ConclusionFor ASD patients with definite surgical indications,RT-3DE guided ASD closure through a right minithoracotomy has more advantages over traditional surgical repair under CBP.

    Release date:2016-08-30 05:47 Export PDF Favorites Scan
  • Efficacy and safety of ultrasound-guided percutaneous retrograde closure of patent ductus arteriosus

    ObjectiveTo evaluate the efficacy and safety of transcatheter closure of patent ductus arteriosus (PDA) with transthoracic echocardiography (TTE).MethodsFrom February 2016 to November 2018, 98 patients of pure PDA were selected, including 43 patients of funnel type and 55 patients of tube type. There were 38 males and 60 females at age of 2-48 (9.8±10.4) years. All patients underwent TTE-guided retrograde closure of the PDA through the femoral artery to establish a femoral-abdominal aorta-thoracic aorta-ductus arteriosus-aorta-right ventricle trajectory.Under the guidance of TTE, a suitable closure umbrella was placed through the femoral artery. One month, 3 months, 6 months, 12 months after the surgery, the patients received out-patient clinical follow-up.ResultsNinety eight patients were successfully occluded by TTE. The occluder was replaced many times in an adult PDA patient, but finally it was successfully plugged. The operation time was 33.2±5.8 min. The lumbar diameter was 12±6 mm. And the postoperative murmur disappeared. Ultrasound showed no shunt between the aorta and the pulmonary artery, and the postoperative hospital stay was 3-4 days. No shunt signal was found in 1, 3, 6, 12 months follow-up. Left atrial anteroposterior diameter (25.8±6.1 mm vs. 30.6±8.4 mm) and left ventricular end diastolic diameter (38.5±9.1 mm vs. 45.2±11.5 mm) were significantly smaller (P < 0.05).ConclusionTTE-guided transcatheter closure of PDA via femoral artery is a safe and effective method to avoid the damage of X-ray and contrast medium. The prospect of clinical application is good.

    Release date:2019-12-13 03:50 Export PDF Favorites Scan
  • Real-time Three-dimensional Echocardiography (RT-3DE) Application in Evaluation of Left Ventricular Motion in Patients with Rheumatic Mitral Stenosis

    ObjectiveTo evaluate myocardial segmental motion function in left ventricular of patients with rheumatic mitral stenosis by using the technology of real-time three-dimensional echocardiography (RT-3DE). MethodsWe retrospectively analyzed the clinical data of 14 patients with rheumatic mitral stenosis between October and November 2014 in our hospital as a trial group. There were 4 males and 10 females with a mean age of 50.9±9.0 years ranging from 34 to 64 years. We chose 11 healthy individuals as a control group. There were 7 males and 4 females with a mean age of 49.5±9.7 years ranging from 32 to 67 years. Both the two groups were subjected to myocardial performance evaluation using two-dimensional echocardiography (2DE) and real-time three-dimensional echocardiography (RT-3DE) to examine the left ventricular ejection fraction (LVEF), left ventricular end-diastolic volume (LVEDV), left ventricular end systolic volume (LVESV), longitudinal strain, circumferential strain, area strain, and lateral strain of each left ventricular myocardial segments. Result RT-3DE detected that the trial group had significantly lower values of LVEF, LVEDV and LVESV than those of the control group (P < 0.05). RT-3DE also revealed that the trial group had a significantly weaker longitudinal strain than the control group (P < 0.05). ConclusionRT-3DE is an accurate technology for assessing myocardial motion and function in patients with rheumatic mitral valve disease.

    Release date: Export PDF Favorites Scan
  • Progress of Transesophageal Echocardiography in Paediatric Surgery

    With the development of surgical technology and the need of clinical, transesophageal echocardiography is more and more favored by clinicians. Although the transesophageal echocardiography has developed more than 20 years, yet it has not been widely used in operation at present in domestic. In addition, its application in surgery of children is more rare. It has been confirmed that intraoperative use of transesophageal echocardiography has good safety and wide range of application. We will summarize indications, complications, and the progress of the current technology from the scope of transesophageal echocardiography in pediatric surgery.

    Release date: Export PDF Favorites Scan
  • Minimally Invasive Transthoracic Closure of Perimembranous Ventricular Septal Defect without Cardiopulmonary Bypass

    Abstract: Objective To introduce a new technique: transthoracic closure of perimembranous ventricular septal defect (VSD) without cardiopulmonary bypass (CPB) under transesophageal echocardiography (TEE)guidance, and summarize the clinical experiences and midterm followup results. Methods A total of 136 patients with perimembranous VSD, 3 months to 15 years averaging 1.8 years, underwent transthoracic device closure. The weight of these patients ranged from 4.0 to 26.0 kg with an average weight of 12.7 kg. The diameter of their VSD ranged from 3 to 12 mm averaging 5.1 mm. A small transthoracic incision (34 cm incision by inferior sternotomy or 23 cm transverse incision in the third intercostal space) was made and the best location for right ventricular puncture was chosen and the delivery pathway was established under TEE guidance. Proper devices were delivered and then deployed to close the defect. Patients were followed up closely with a standard protocol, arranged for echocardiography, electrocardiogram and chest Xray film. Results In all the cases, 131 cases of VSD (96.3%) were successfully closed. The procedure time was less than 90 minutes and the implanting time was 5.42 minutes (16.3±5.7 min). Symmetrical devices were implanted into 89(67.9%) of the 131 patients and the other 42 patients (32.1%) were closed with asymmetrical ones. The result of TEE soon after operation showed that 3 patients had tiny residual shunt, 4 had new trivial and mild tricuspid regurgitation (TR). However, no TR worsening, aortic regurgitation (AR), complete atrioventricular heart block, or left or right outflow tract obstruction was detected in all patients. One patient 〖CM(159mm〗with transient atrioventricular block restored to sinus rhythm after 3 days of medical treatment. Five cases (3.7%) were converted to conventional open heart repair during the operation. Followup was done to all the patients for a period ranged from 6 months to 30 months (18.3±6.6 months). Tiny residual shunt in the 3 cases mentioned above vanished during the followup period. No new TR, AR, hemolysis, thrombosis, dislocation of the devices, or outflow stenosis was detected postoperatively. The tiny incision caused less psychologic depression. Conclusion Minimally invasive transthoracic device closure of VSD without CPB is a simple, effective and safe intervention under guidance of TEE for most of perimembranous VSD patients. The short and midterm clinical outcomes are promising. Longterm followup is indispensable.

    Release date:2016-08-30 06:02 Export PDF Favorites Scan
  • Recent clinical development of minimally invasive closure for atrial septal defect

    Atrial septal defect (ASD) is a congenital heart disease that causes blood communication between the left and right ventricles due to partial atrial septal tissue defects, accounting for about 13% of all heart malformations. Secondary ASD is the most common type of ASD and can generally be treated with minimally invasive closure. At present, the commonly used minimally invasive methods in clinical practice mainly include X-ray-guided percutaneous occlusion, transesophageal ultrasound-guided transthoracic occlusion and ultrasound-guided percutaneous occlusion. This review focuses on the basic research process of occluder materials, and advantages and disadvantages of three different surgical methods.

    Release date:2021-12-27 11:31 Export PDF Favorites Scan
  • Predictive value of systolic pulmonary artery pressure on autonomic nerve excitation in 186 patients with valvular disease: A prospective study

    ObjectiveTo explore the predictive value of systolic pulmonary artery pressure (SPAP) on autonomic nerve excitation in patients with valvular disease, so as to provide reference for the formulation of clinical intervention plans. Methods The clinical data of patients with valvular disease who received surgical treatment in the General Hospital of Northern Theater Command from August 28, 2020 to February 3, 2021 were prospectively collected. According to the standard deviation of normal-to-normal R-R intervals (SDNN) of the heart rate variability (HRV) of the long-range dynamic electrocardiogram (ECG) 7 days before the operation, the patients were divided into three groups: a sympathetic dominant (SE) group (SDNN≤50 ms), a balance group (50 ms<SDNN<100 ms) and a parasympathetic dominant (PSE) group (SDNN≥100 ms). The correlation between the changes of echocardiographic indexes and autonomic nerve excitation among the groups and the predictive values were analyzed. Results A total of 186 patients were enrolled, including 108 males and 78 females aged 55.92±11.99 years. There were 26 patients in the SE group, 104 patients in the balance group, and 56 patients in the PSE group. The left anteroposterior diameter (LAD), left ventricular end diastolic inner diameter, ratio of peak E to peak A of mitral valve (Em/Am), left ventricular end diastolic volume, left ventricular end systolic volume and SPAP in the SE group were higher than those in the balance group (P<0.05), while peak A of tricuspid valve (At) and left ventricular ejection fraction (LVEF) were lower than those in the balance group (P<0.05). The LAD and Em/Am in the balance group were significantly higher than those in the PSE group (P<0.05). Multivariate analysis showed that patients in the SE group had lower At (right atrial systolic function declines), lower LVEF and higher SPAP than those in the balance group (P=0.04, 0.04 and 0.00). When HRV increased and parasympathetic nerve was excited in patients with valvular disease, Em/Am decreased (left atrial function and/or left ventricular diastolic function declined) with a normal LAD. Pearson analysis showed that there was a linear negative correlation between SPAP and SDNN, with a coefficient of −0.348, indicating that the higher SPAP, the lower HRV and the more excited sympathetic nerve. Receiver operating characteristic curve showed that when SPAP≥45.50 mm Hg (1 mm Hg=0.133 kPa), the sensitivity and specificity of sympathetic excitation in patients with valvular disease were 84.60% and 63.70%, respectively. ConclusionParasympathetic excitation is an early manifestation of the disease, often accompanied by decreased left atrial function and/or left ventricular diastolic function. Sympathetic nerve excitation can be accompanied by the increase of SPAP and the decrease of left ventricular and right atrial systolic function. SPAP has a unique predictive value for the prediction of autonomic nerve excitation in patients with valvular disease.

    Release date:2024-02-20 03:09 Export PDF Favorites Scan
  • Value of transthoracic echocardiography to monitor and evaluate aortic insufficiency after implantation of left ventricular assist device

    ObjectiveTo explore the value of transthoracic echocardiography (TTE) to monitor and evaluate aortic insufficiency (AI) within one year after the implantation of the left ventricular assist device (LVAD).MethodsWe retrospectively collected and analyzed the TTE data of 12 patients who received LVAD implantation from 2018 to 2020 in our hospital. All patients were males, with an average age of 43.3±8.6 years. We analyzed temporal changes in the aortic annulus (AA), aortic sinus (AoS), ascending aorta (AAo), the severity of AI and the opening of aortic valve before operation and 1 month, 3 months, 6 months and 12 months after LVAD implantation.ResultsAll 12 patients survived within 1 year after LVAD implantation. One patient was bridged to heart transplantation 6 months after implantation, and two patients did not receive TTE after 3 and 6 months. Compared to pre-implantation, AoS increased at 1 month after implantation (31.58±5.09 mm vs. 33.83±4.69 mm). The inner diameters of AA, AoS and AAo increased at 3, 6 and 12 months after LVAD implantation compared to pre-implantation (P<0.05), but all were within the normal range except for one patient whose AoS slightly increased before operation. After LVAD pump speed was adjusted, the opening of aortic valve improved. The severity of AI increased at 6 and 12 months after LVAD implantation compared to pre-implantation, and increased at 12 months compared to 6 months after LVAD implantation (P<0.05).ConclusionTTE can evaluate aortic regurgitation before and after LVAD implantation and monitor the optimization and adjustment of LVAD pump function, which has a positive impact on the prognosis after LVAD implantation.

    Release date:2021-07-02 05:22 Export PDF Favorites Scan
  • Pure echocardiography-guided implantation and localization of transcatheter left ventricular assist pump: A report of two cases

    Transcatheter left ventricular assist pump (LVAP) is widely used in cardiogenic shock, post-circulatory hypoperfusion syndrome and high-risk percutaneous coronary intervention (PCI), and its application scenarios cover various complex environments such as ICU, operating room, emergency department and catheterization room. It is important to quickly and accurately implant the transcatheter LVAP and monitor its position in real time. This paper reported 2 male patients with high-risk PCI, aged 47 and 45 years, both with triple coronary artery disease and reduced ejection fraction (<35%). The domestically produced transcatheter LVAP was implanted using an echocardiography guidance technology system, and PCI treatment was performed under the assistance of the interventional pump. The operation was smooth, and the interventional pump assisted for 1 h in 2 patients, and the pump was successfully removed. There were no obvious complications related to the pump and PCI after the operation, and the patients were discharged smoothly.

    Release date:2024-11-27 02:45 Export PDF Favorites Scan
  • Study on Downstream Flow Field Uniformity of Aortic Stenosis by Using Pulse Wave Doppler Echocardiography

    ObjectiveBy comparing the difference between different stenosed degree of aortic valve in flow field uniformity and turbulent shear stress (TSS), to explore the relation between flow field uniformity and different stenosed degree of aortic valve, and probe the clinical value for deciding the operation timing, and analyze the possible role of TSS in the progress of the disease.MethodsThe flow field uniformity values and TSS in parasternal long axis plane and apical five cavity plane on each point were measured and calculated by pulse wave Doppler echocardiography technique for 33 patients with different stenosed degree of aortic valve.ResultsThere were significant difference between the different stenosed degree of aortic valve in maximal velocity difference(ΔV max )and TSS( P lt;0.05, 0.01). The more severe the aortic stenosis was, the worse the flow field uniformity was, the lower the TSS was.ConclusionsThere are significant difference between the patients of different stenosed degree of aortic valve in flow field uniformity. Flow field uniformity has important value in classifying the degree of aortic stenosis and deciding the timing of operation. The more severe the aortic stenosis is ,the lower TSS is. It can be thought that low TSS distribution has important role in pathological process of constriction in cardiovascular system diseases.

    Release date:2016-08-30 06:24 Export PDF Favorites Scan
7 pages Previous 1 2 3 ... 7 Next

Format

Content