west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "exoskeleton" 14 results
  • Research progress on compliant characteristics of lower extremity exoskeleton robots

    The lower extremity exoskeleton robot is a wearable device designed to help people suffering from a walking disorder to regain the power of the legs and joints to achieve standing and walking functions. Compared with traditional robots that include rigid mechanisms, lower extremity exoskeleton robots with compliant characteristics can store and release energy in passive elastic elements while minimizing the reaction force due to impact, so it can improve the safety of human-robot interaction. This paper reviews the compliant characteristics of lower extremity exoskeleton robots from the aspects of compliant drive and compliant joint, and introduces the augmentation, assistive, rehabilitation lower extremity exoskeleton robots. It also prospect the future development trend of lower extremity exoskeleton robots.

    Release date:2019-02-18 03:16 Export PDF Favorites Scan
  • Construction and analysis of muscle functional network for exoskeleton robot

    Exoskeleton nursing robot is a typical human-machine co-drive system. To full play the subjective control and action orientation of human, it is necessary to comprehensively analyze exoskeleton wearer’s surface electromyography (EMG) in the process of moving patients, especially identifying the spatial distribution and internal relationship of the EMG information. Aiming at the location of electrodes and internal relation between EMG channels, the complex muscle system at the upper limb was abstracted as a muscle functional network. Firstly, the correlation characteristics were analyzed among EMG channels of the upper limb using the mutual information method, so that the muscle function network was established. Secondly, by calculating the characteristic index of network node, the features of muscle function network were analyzed for different movements. Finally, the node contraction method was applied to determine the key muscle group that reflected the intention of wearer’s movement, and the characteristics of muscle function network were analyzed in each stage of moving patients. Experimental results showed that the location of the myoelectric collection could be determined quickly and efficiently, and also various stages of the moving process could effectively be distinguished using the muscle functional network with the key muscle groups. This study provides new ideas and methods to decode the relationship between neural controls of upper limb and physical motion.

    Release date:2019-08-12 02:37 Export PDF Favorites Scan
  • Effects of ankle exoskeleton assistance during human walking on lower limb muscle contractions and coordination patterns

    Lower limb ankle exoskeletons have been used to improve walking efficiency and assist the elderly and patients with motor dysfunction in daily activities or rehabilitation training, while the assistance patterns may influence the wearer’s lower limb muscle activities and coordination patterns. In this paper, we aim to evaluate the effects of different ankle exoskeleton assistance patterns on wearer’s lower limb muscle activities and coordination patterns. A tethered ankle exoskeleton with nine assistance patterns that combined with differenet actuation timing values and torque magnitude levels was used to assist human walking. Lower limb muscle surface electromyography signals were collected from 7 participants walking on a treadmill at a speed of 1.25 m/s. Results showed that the soleus muscle activities were significantly reduced during assisted walking. In one assistance pattern with peak time in 49% of stride and peak torque at 0.7 N·m/kg, the soleus muscle activity was decreased by (38.5 ± 10.8)%. Compared with actuation timing, the assistance torque magnitude had a more significant influence on soleus muscle activity. In all assistance patterns, the eight lower limb muscle activities could be decomposed to five basic muscle synergies. The muscle synergies changed little under assistance with appropriate actuation timing and torque magnitude. Besides, co-contraction indexs of soleus and tibialis anterior, rectus femoris and semitendinosus under exoskeleton assistance were higher than normal walking. Our results are expected to help to understand how healthy wearers adjust their neuromuscular control mechanisms to adapt to different exoskeleton assistance patterns, and provide reference to select appropriate assistance to improve walking efficiency.

    Release date:2022-04-24 01:17 Export PDF Favorites Scan
  • Research on performance optimization method of human-machine physical interaction system considering exoskeleton wearing comfort

    In order to improve the wearing comfort and bearing effectiveness of the exoskeleton, based on the prototype and working mechanism analysis of a relaxation wearable system for knee exoskeleton robot, the static optimization synthesis and its method are studied. Firstly, based on the construction of the virtual prototype model of the system, a comprehensive wearable comfort evaluation index considering the factors such as stress, deformation and the proportion of stress nodes was constructed. Secondly, based on the static simulation and evaluation index of system virtual prototype, multi-objective genetic optimization and local optimization synthesis of armor layer topology were carried out. Finally, the model reconstruction simulation data confirmed that the system had good wearing comfort. Our study provides a theoretical basis for the bearing performance and prototype construction of the subsequent wearable system.

    Release date:2023-02-24 06:14 Export PDF Favorites Scan
  • Exoskeleton robot system based on real-time gait analysis for walking assist

    This paper presents a wearable exoskeleton robot system to realize walking assist function, which oriented toward the patients or the elderly with the mild impairment of leg movement function, due to illness or natural aging. It reduces the loads of hip, knee, ankle and leg muscles during walking by way of weight support. In consideration of the characteristics of the psychological demands and the disease, unlike the weight loss system in the fixed or followed rehabilitation robot, the structure of the proposed exoskeleton robot is artistic, lightweight and portable. The exoskeleton system analyzes the user's gait real-timely by the plantar pressure sensors to divide gait phases, and present different control strategies for each gait phase. The pressure sensors in the seat of the exoskeleton system provide real-time monitoring of the support efforts. And the drive control uses proportion-integral-derivative (PID) control technology for torque control. The total weight of the robot system is about 12.5 kg. The average of the auxiliary support is about 10 kg during standing, and it is about 3 kg during walking. The system showed, in the experiments, a certain effect of weight support, and reduction of the pressure on the lower limbs to walk and stand.

    Release date:2017-04-13 10:03 Export PDF Favorites Scan
  • Application of digital intellectualization technique in rehabilitation of spinal cord injury

    With the breakthroughs of digitization, artificial intelligence and other technologies and the gradual expansion of application fields, more and more studies have been conducted on the application of digital intelligence technologies such as exoskeleton robots, brain-computer interface, and spinal cord neuromodulation to improve or compensate physical function after spinal cord injury (SCI) and improve self-care ability and quality of life of patients with SCI. The development of digital intelligent rehabilitation technology provides a new application platform for the functional reconstruction after SCI, and the digital and intelligentized rehabilitation technology has broad application prospects in the clinical rehabilitation treatment after SCI. This article elaborates on the current status of exoskeleton robots, brain-computer interface technology, and spinal cord neuromodulation technology for functional recovery after SCI.

    Release date: Export PDF Favorites Scan
  • A pace recognition method for exoskeleton wearers based on support vector machine-hidden Markov model

    In order to improve the motion fluency and coordination of lower extremity exoskeleton robots and wearers, a pace recognition method of exoskeleton wearer is proposed base on inertial sensors. Firstly, the triaxial acceleration and triaxial angular velocity signals at the thigh and calf were collected by inertial sensors. Then the signal segment of 0.5 seconds before the current time was extracted by the time window method. And the Fourier transform coefficients in the frequency domain signal were used as eigenvalues. Then the support vector machine (SVM) and hidden Markov model (HMM) were combined as a classification model, which was trained and tested for pace recognition. Finally, the pace change rule and the human-machine interaction force were combined in this model and the current pace was predicted by the model. The experimental results showed that the pace intention of the lower extremity exoskeleton wearer could be effectively identified by the method proposed in this article. And the recognition rate of the seven pace patterns could reach 92.14%. It provides a new way for the smooth control of the exoskeleton.

    Release date:2022-04-24 01:17 Export PDF Favorites Scan
  • Study on the influence of wearable lower limb exoskeleton on gait characteristics

    The purpose of this paper was to investigate the effects of wearable lower limb exoskeletons on the kinematics and kinetic parameters of the lower extremity joints and muscles during normal walking, aiming to provide scientific basis for optimizing its structural design and improving its system performance. We collected the walking data of subjects without lower limb exoskeleton and selected the joint angles in sagittal plane of human lower limbs as driving data for lower limb exoskeleton simulation analysis. Anybody (the human biomechanical analysis software) was used to establish the human body model (the human body model without lower limb exoskeleton) and the man-machine system model (the lower limb exoskeleton model). The kinematics parameters (joint force and joint moment) and muscle parameters (muscle strength, muscle activation, muscle contraction velocity and muscle length) under two situations were compared. The experimental result shows that walking gait after wearing the lower limb exoskeleton meets the normal gait, but there would be an occasional and sudden increase in muscle strength. The max activation level of main lower limb muscles were all not exceeding 1, in another word the muscles did not appear fatigue and injury. The highest increase activation level occurred in rectus femoris (0.456), and the lowest increase activation level occurred in semitendinosus (0.013), which means the lower limb exoskeletons could lead to the fatigue and injury of semitendinosus. The results of this study illustrate that to avoid the phenomenon of sudden increase of individual muscle force, the consistency between the length of body segment and the length of exoskeleton rod should be considered in the design of lower limb exoskeleton extremity.

    Release date:2019-12-17 10:44 Export PDF Favorites Scan
  • Comfort optimization of a new type of foot mechanism for lower extremity exoskeleton

    In order to reduce the impact caused by the contact between the foot and the ground when wearing the lower extremity exoskeleton under the condition of high load, this paper proposed an exoskeleton foot mechanism for improving the foot comfort, and optimized the key index of its influence on the comfort. Firstly, the physical model of foot mechanism was established based on the characteristics of foot stress in gait period, and then the mathematical model of vibration was abstracted. The correctness of the model was verified by the finite element analysis software ANSYS. Then, this paper analyzed the influence of vibration parameters on absolute transmissibility based on vibration mathematical model, and optimized vibration parameters with MATLAB genetic algorithm toolbox. Finally, this paper took white noise to simulate the road elevation as the vibration input, and used the visual simulation tool Simulink in MATLAB and the vibration equation to construct the acceleration simulation model, and then calculated the vibration weighted root mean square acceleration value of the foot. The results of this study show that this foot comfort mechanism can meet the comfort indexes of vibration absorption and plantar pressure, and this paper provides a relatively complete method for the design of exoskeleton foot mechanism, which has reference significance for the design of other exoskeleton foot and ankle joint rehabilitation mechanism.

    Release date:2020-06-28 07:05 Export PDF Favorites Scan
  • Design and support performance evaluation of medical multi-position auxiliary support exoskeleton mechanism

    Aiming at the status of muscle and joint damage caused on surgeons keeping surgical posture for a long time, this paper designs a medical multi-position auxiliary support exoskeleton with multi-joint mechanism by analyzing the surgical postures and conducting conformational studies on different joints respectively. Then by establishing a human-machine static model, this study obtains the joint torque and joint force before and after the human body wears the exoskeleton, and calibrates the strength of the exoskeleton with finite element analysis software. The results show that the maximum stress of the exoskeleton is less than the material strength requirements, the overall deformation is small, and the structural strength of the exoskeleton meets the use requirements. Finally, in this study, subjects were selected to participate in the plantar pressure test and biomechanical simulation with the man-machine static model, and the results were analyzed in terms of plantar pressure, joint torque and joint force, muscle force and overall muscle metabolism to assess the exoskeleton support performance. The results show that the exoskeleton has better support for the whole body and can reduce the musculoskeletal burden. The exoskeleton mechanism in this study better matches the actual working needs of surgeons and provides a new paradigm for the design of medical support exoskeleton mechanism.

    Release date:2024-04-24 09:50 Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content