west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "knee" 311 results
  • Application of infiltration between the popliteal artery and capsule of the knee block in analgesia after total knee arthroplasty

    Effective postoperative pain management in patients undergoing total knee arthroplasty is an important part of the realization of enhanced recovery after surgery. Peripheral nerve block is of great significance to the control of postoperative pain, and clinicians are committed to finding a nerve block that has little impact on muscle strength and is conducive to the early recovery of motor function after total knee arthroplasty. Infiltration between the popliteal artery and capsule of the knee block can selectively block the sensory branch of the posterior end of the knee joint without affecting the motor branch of the common peroneal nerve, so that the muscle strength can be minimally affected under the condition of adequate analgesia. This article reviews the proposal of infiltration between the popliteal artery and capsule of the knee block, the approach and method of the block, and the advantages of combining with different nerve blocks for analgesia after total knee arthroplasty.

    Release date:2022-04-25 03:47 Export PDF Favorites Scan
  • Free latissimus dorsi myocutaneous flap transplantation combined with external fixation for bone and soft tissue defects around knee joint

    Objective To investigate the effectiveness of free latissimus dorsi myocutaneous flap transplantation combined with external fixation in the treatment of bone and soft tissue defects around the knee joint. Methods A retrospective analysis was conducted on the clinical data of 13 patients with high-energy trauma-induced bone and soft tissue defects around the knee joint admitted between January 2016 and July 2023. Among them, 11 were male and 2 were female, the age ranged from 23 to 61 years, with an average of 35.7 years. The causes of injury included 10 cases of traffic accident, 2 cases of machine entanglement injury, and 1 case of heavy object crush injury. According to the Gustilo-Anderson classification, 11 cases were type Ⅲ B and 2 cases were type Ⅲ C. Post-injury, 2 cases had wound infection and 2 cases had popliteal artery injury. The time from injury to flap repair was 40-49 days, with an average of 27.5 days. The wound size was 18 cm×13 cm to 32 cm×20 cm, all accompanied by distal femoral bone defects and quadriceps muscle defects. After primary debridement, vacuum sealing drainage combined with external fixation was used for treatment. In the second stage, free latissimus dorsi myocutaneous flaps were transplanted to repair soft tissue defects, with the flap size ranging from 20 cm×15 cm to 34 cm×22 cm. The donor sites of 9 flaps were directly sutured, and 4 cases with large tension were repaired with a keystone flap based on the posterior intercostal artery perforator. At 6-15 months postoperatively, with an average of 10.5 months, 11 patients underwent knee arthrodesis surgery; 2 patients with large bone defects at the distal femur and proximal tibia underwent multi-segment bone transport reconstruction of the bone defect. At last follow-up, the recovery of the flap and the donor site was recorded, and the function of the shoulder joint was evaluated by the American Shoulder and Elbow Surgeons (ASES) score, and the function of the affected knee joint was evaluated by the Knee Society Score (KSS). ResultsAll the flaps survived after operation, the wounds and donor site incisions healed by first intention. All 13 patients were followed up 15-55 months, with an average of 21.6 months. Four patients who underwent the restoration of the donor site with the thoracodorsal keystone perforator flap had obvious scar hyperplasia around the wound, but no contracture or symmetrical breasts on both sides. At last follow-up, the appearance and texture of the flaps were good; the bony fusion of the knee joint was good, and the range of motion and function recovered well; the shoulder joint function on the flap-harvested side was not significantly affected, and the range of motion was satisfactory. The ASES shoulder joint score of the latissimus dorsi muscle-harvested side was 85-95, with an average of 89.5. The knee joint function KSS score was 75-90, with an average of 81.2. ConclusionFree latissimus dorsi myocutaneous flap transplantation combined with external fixation for the treatment of bone and soft tissue defects around the knee joint caused by high-energy trauma can repair bone and soft tissue defects and reconstruct the stability of the knee joint, effectively preserve the integrity of the limb and soft tissues, and improve the patient’s ability of self-care.

    Release date: Export PDF Favorites Scan
  • Influence of lateral retinacular release on anterior knee pain following total knee arthroplasty

    Objective To investigate the effect of lateral retinacular release on the clinical outcomes after total knee arthroplasty (TKA) without resurfacing of the patella. Methods A prospective randomized controlled study was performed on 132 patients with unilateral degenerative knee arthritis undergoing TKA bewteen October 2012 and October 2014, who met the selection criteria. During TKA, lateral retinacular release was used in 66 cases (trial group) and was not used in 66 cases (control group). Two patients were excluded from the study due to missing the follow-up in trial group. Four patients were excluded from the study due to lateral retinacular release in control group. Finally, 64 patients and 62 patients were included in the trial group and in the control group. There was no significant difference in gender, age, body mass index, side, disease duration, preoperative patellar morphology, grading of patellofemoral arthritis, grade of patellar cartilage degeneration, patellar malposition, patellar maltracking, patellar score, and Knee Society Score (KSS) between 2 groups (P>0.05). The operation time, postoperative drainage volume, hospitalization time, postoperative complications, and patient satisfaction were recorded. Postoperative anterior knee pain was assessed by visual analogue scale (VAS), and the knee joint function was evaluated by KSS score and patellar score. The femoral angle, tibial angle, femoral flexion angle, and tibial posterior slope angle were measured on the X-ray film for postoperative prosthetic alignment. The postoperative patellar tracking and patellar position, as well as the presence of osteolysis, prosthesis loosening, patellar fracture and patellar necrosis were observed. Results All patients were followed up for 24 months. There was no significant difference in operation time, postoperative drainage volume, hospitalization time, and patient satisfaction between 2 groups (P>0.05). The incidence of anterior knee pain in the trial group was better than that in the control group (P=0.033). KSS score and patellar score were significantly improved in both groups at 24 months after operation when compared with preoperative scores (P<0.05), but no significant difference was found between 2 groups (P>0.05). Complications included hematoma (2 cases in the trial group, and 1 case in the control group), mild wound dehiscence (2 cases in each group respectively), skin-edge necrosis (1 case in the trial group), and superficial wound infection (1 case in each group respectively), which were cured by conservative treatment. No patellar necrosis, patella fracture, or knee lateral pain occurred in 2 groups. There was no significant difference in complication rate between groups (P=0.392). Satisfactory implant alignment was observed in both groups during follow-up. There was no significant difference in femoral angle, tibial angle, femoral flexion angle, and tibial posterior slope angle between 2 groups (P>0.05). No radiolucent line at the bone-implant interface was seen around the tibial components and femoral components in both groups. The patellar maltracking was observed in 3 patients of the trial group and 5 patients of the control group, showing no significant difference (P=0.488). However, the incidence of patellar malposition in the trial group (18.8%) was significantly lower than that in the control group (35.5%) (χ2=0.173,P=0.034). Conclusion Lateral retinacular release during primary TKA without resurfacing of the patella can reduce postoperative knee pain without increasing complications.

    Release date:2017-05-05 03:16 Export PDF Favorites Scan
  • ADVANCEMENT OF ROTATIONAL ALIGNMENT OF FEMORAL PROSTHESIS IN TOTAL KNEE ARTHROPLASTY

    Objective To introduce the concept and clinical applications of rotational alignment of the femoral prosthesis in total knee arthroplasty (TKA) so as to avoide the postoperative complications caused by rotational alignment. Methods The clinical and experimental research literature about rotational alignment of the femoral prosthesis in TKA was extensively reviewed and analyzed. Results Femoral prosthesis malrotation can lead to flexion gap unbalanced and undesirable patellar track. Rotation alignment of the femoral prosthesis is defined with radiological and computer assisted technique at pre- and post-operation, which can make the rotation alignment of the femoral prosthesis and the function of the knee favorable. Conclusion In recent years, many surgical skills and new techniques of defining the rotational alignment are developed, and good clinical results are achieved.

    Release date:2016-08-31 05:45 Export PDF Favorites Scan
  • Effect of surgeon’s handedness on distribution of prosthesis during primary total knee arthroplasty

    ObjectiveTo evaluate the effect of the surgeon’s handedness on the distribution of prosthesis during primary total knee arthroplasty (TKA).MethodsA retrospective analysis was performed on 86 patients (100 knees) with primary TKA completed by the same right-handed surgeon between December 2016 and December 2018, including 72 cases of single knee and 14 of bilateral knees. The patients were divided into dominant group (right side) and non-dominant group (left side) according to the operating position of the surgeon and each group had 50 knees. There was no significant difference in gender, age, body mass index, disease duration, clinical diagnosis, preoperative Hospital for Special Surgery (HSS) score, and other general data between the two groups (P>0.05). The operation time and complications were recorded in both groups. The function of knee was evaluated by HSS score. Hip-knee-ankle angle (HKA), mechanical lateral distal femoral angle (mLDFA), and mechanical medial proximal tibial angle (mMPTA) were measured by using X-ray film of full-length lower extremity before TKA and at 2 weeks after TKA that were used to evaluate the coronal position of the prosthesis. Posterior distal femoral angle (PDFA) and posterior proximal tibial angle (PPTA) were measured by using lateral X-ray films at 3 months after operation that were used to evaluate the sagittal position of the prosthesis.ResultsThere was no significant difference in operation time between the two groups (t=−1.128, P=0.262). One case of posterior tibial artery thrombosis occurred in the dominant group, and 1 case of poor healing of the incision occurred in each of the dominant group and the non-dominant group. Patients in both groups were followed up 12-34 months with an average of 22.0 months. The HSS scores at last follow-up were 87.2±4.3 in the dominant group and 86.8±5.0 in the non-dominant group. There was no significant difference between the two groups (t=0.471, P=0.639). No complications such as periprosthetic infection, prosthetic loosening, or periprosthetic fracture occurred during follow-up. There was no significant difference in the HKA, mLDFA, and mMPTA between the two groups before and after operation (P>0.05). The differences in the incidence of sagittal femoral prosthesis malposition and PDFA between the two groups were significant (P<0.05); however, there was no significant difference in the PPTA, the rate of femoral prosthesis distributed in the neutral position, the incidence of over-flexed femoral prosthesis, and the incidence of anterior femoral notch (P>0.05).ConclusionThe surgeon’s handedness is one of the factors affecting the placement of the sagittal femoral prosthesis in primary TKA. The incidence of sagittal femoral prosthesis malposition could increase when the surgeon performs on the non-dominant side.

    Release date:2020-07-07 07:58 Export PDF Favorites Scan
  • Effectiveness of one-stage total knee arthroplasty with tibial stem extender for knee arthritis complicated with tibial stress fracture

    ObjectiveTo evaluate the early effectiveness of one-stage total knee arthroplasty (TKA) with tibial stem extender for knee arthritis complicated with tibial stress fractures. MethodsBetween January 2014 and November 2016, 12 patients (12 knees) with knee arthritis and tibial stress fractures underwent one-stage TKA with tibial stem extender. There were 5 males and 7 females with an average age of 71.5 years (range, 60-77 years). There were 8 cases with osteoarthritis and 4 cases with rheumatoid arthritis. The radiographic examination showed the 6 cases of intra-articular fractures and 6 of extra-articular fractures (including transverse fractures in 4 cases and short oblique fractures in 2 cases); 2 cases complicated with middle and upper fibular fractures; 12 cases of varus deformities. Preoperative Knee Society Score (KSS) clinical score was 31.5±8.4 and functional score was 33.3±9.0. The preoperative range of motion (ROM) of the knee was (65.6±9.6)°. ResultsAll incisions healed primarily and no wound infection or skin necrosis occurred. All patients were followed up 36.5 months on average (range, 6-52 months). X-ray films showed that all fractures healed at 3-7 months (mean, 4 months); the position of the prosthesis was good, and no loosening or signs of infection occurred. At last follow-up, the KSS clinical score was 90.5±8.9 and functional score was 92.1±7.8; the ROM of the knee was (115.0±9.8)°. All indexes were significantly improved than those before operation (t=40.340, P=0.000; t=32.120, P= 0.000; t=8.728, P=0.000). ConclusionOne-stage TKA with tibial stem extender for patients with knee arthritis and tibial stress fractures can restore limb alignment, facilitate fracture healing, and obtain the satisfactory early effectiveness.

    Release date:2018-09-03 10:13 Export PDF Favorites Scan
  • Musculoskeletal multibody dynamics investigation for the different medial-lateral installation position of the femoral component in unicompartmental knee arthroplasty

    The surgical installation accuracy of the components in unicompartmental knee arthroplasty (UKA) is an important factor affecting the joint function and the implant life. Taking the ratio of the medial-lateral position of the femoral component relative to the tibial insert (a/A) as a parameter, and considering nine installation conditions of the femoral component, this study established the musculoskeletal multibody dynamics models of UKA to simulate the patients’ walking gait, and investigated the influences of the medial-lateral installation positions of the femoral component in UKA on the contact force, joint motion and ligament force of the knee joint. The results showed that, with the increase of a/A ratio, the medial contact force of the UKA implant was decreased and the lateral contact force of the cartilage was increased; the varus rotation, external rotation and posterior translation of the knee joint were increased; and the anterior cruciate ligament force, posterior cruciate ligament force and medial collateral ligament force were decreased. The medial-lateral installation positions of the femoral component in UKA had little effect on knee flexion-extension movement and lateral collateral ligament force. When the a/A ratio was less than or equalled to 0.375, the femoral component collided with the tibia. In order to prevent the overload on the medial implant and lateral cartilage, the excessive ligament force, and the collision between the femoral component and the tibia, it is suggested that the a/A ratio should be controlled within the range of 0.427−0.688 when the femoral component is installed in UKA. This study provides a reference for the accurate installation of the femoral component in UKA.

    Release date:2023-08-23 02:45 Export PDF Favorites Scan
  • Comparison of unicompartmental knee arthroplasty and total knee arthroplasty in the treatment of severe medial compartment osteoarthritis

    ObjectiveTo compare the effectiveness of unicompartmental knee arthroplasty (UKA) and total knee arthroplasty (TKA) in the treatment of severe medial compartment osteoarthritis (OA).MethodsA clinical data of 69 patients (69 knees), who underwent joint replacement due to severe medial compartment OA between February 2015 and September 2018 and met the selection criteria, was retrospectively analyzed. Among them, 38 cases were treated with UKA (UKA group) and 31 cases with TKA (TKA group). There was no significant difference in gender, age, body mass index, course of disease, lesion side, and preoperative visual analogue scale (VAS) score, Hospital for Special Surgery (HSS) score, Western Ontario and McMaster University Osteoarthritis Index (WOMAC) score, Feller score, range of motion of knee, physiological and psychological scores of short-form 12 health survey scale (SF-12) between the two groups (P>0.05). The femorotibial angle (FTA) of TKA group was bigger than that of UKA group, and hip-knee-ankle angle (HKA) was smaller, showing significant differences (P<0.05). The operative time, incision length, blood loss, time for flexion 90°, ambulation time, hospital stay, and incidence of deep venous thrombosis of lower extremity were recorded and compared between the two groups. The VAS score, HSS score, WOMAC score, Feller score, range of motion, and physiological and psychological scores of SF-12 were used to evaluate patients’ quality of life. FTA, HKA, and prosthesis looseness were observed by X-ray films. Kaplan-Merier survival analysis was used to evaluate the survival rate of prosthesis.ResultsAll operations were successfully completed in both groups. Compared with TKA group, UKA group had shorter incision length, longer operative time, and less blood loss (P<0.05). There was no significant difference in time for flexion 90°, ambulation time, hospital stay, and the incidence of deep venous thrombosis of lower extremity between the two groups (P>0.05). The incisions in both groups healed by first intention. During follow-up, 3 patients in the UKA group and 1 patient in the TKA group developed mild anterior knee pain. Patients were followed up (30.7±9.6) months in the UKA group and (34.9±8.7) months in the TKA group, and the difference was not significant (t=–1.832, P=0.071). At last follow-up, there were significant differences in the HSS score, Feller score, WOMAC score, range of motion, VAS score, and physiological and psychological scores of SF-12 between pre- and post-operation (P<0.05). The range of motion in the UKA group was bigger than that in the TKA group (Z=–2.666, P=0.008), and there was no significant difference in the other indexes between the two groups (P>0.05). X-ray films showed that the alignment of the two groups recovered well, and the FTA and HKA of the two groups were improved at 1 week after operation (P<0.05). No radiolucency was found around the prosthesis during follow-up, no prosthesis loosening and meniscal bearing dislocation occurred. The survival rates of the prostheses in the two groups were 100%.ConclusionFor severe medial compartment OA, the early survival rates of the two prostheses are similar, but UKA has less traumatic, can preserve the normal structure of the knee, and the range of motion of the knee after operation is significantly better than TKA.

    Release date:2021-09-28 03:00 Export PDF Favorites Scan
  • MODIFIED ROBOTIZED HYDRAULIC TENSOR FOR LIGAMENT BALANCE IN TOTAL KNEE ARTHROPLASTY

    Objective To investigate a modified robotized hydraulictensor for management of the ligament balance in the total knee arthroplasty. Methods The effect of the modified robotized hydraulic tensor on the mechanical behaviour of the ligament system balance in the total knee arthroplasty was analyzed andthe related information was obtained. Results The robotized hydraulic tensor acted as a tensorsensor system, which could assist the surgeon by providing thequantitative information to align the lower limb in extension, equalize the articular spaces in extension and flexion, balance the internal and external forces, and define the femoral component rotation, and by providing the information toplan the releasing of the soft tissues and the rotating of the femoral component. Conclusion The modified robotized hydraulic tensor can enable the surgeon to properly manage the ligament balance in the total knee arthroplasty.

    Release date:2016-09-01 09:20 Export PDF Favorites Scan
  • Biomechanical analysis of sitting-up movement of knee joint after robot-assisted unicompartmental knee arthroplasty

    Objective To investigate the effect of Navio robot-assisted unicompartmental knee arthroplasty (UKA) on the biomechanics of knee joint during sitting-up movement, and to determine whether UKA can maintain the biomechanical characteristics of knee joint. Methods The clinical data of 8 patients with medial compartment osteoarthritis treated with medial fixed platform of Navio robot-assisted UKA between January 2018 and January 2019 and had the complete follow-up data were retrospectively analyzed. There were 4 males and 4 females; the age ranged from 58 to 67 years, with an average of 62.3 years. The disease duration was 6-18 months, with an average of 13 months. The varus deformity ranged from 4° to 6°, with an average of 5°; the knee flexion range of motion was 0°-130°, with an average of 110°. All patients had no extension limitation. The imaging data of bilateral knees during sitting-up movement were collected by biplane C-arm X-ray machine at 3 weeks before operation and 7 months after operation. The three-dimensional models of femur and tibia were established by dual-energy CT scanning, and the three-dimensional models of femur and tibia were matched and synchronized with the femur and tibia in X-ray film by automatic matching tracer software. The biomechanical parameters of femur and tibia were measured, including internal rotation/external rotation, varus/valgus, forward/backward displacement of medial and lateral tibia contact center, and lateral compartment joint space. Results Eight patients were followed up 5-7 months, with an average of 6.4 months. In the comparison of the affected side before and after operation, except for the difference of varus/valgus which was significant (t=4.959, P=0.002), the differences in other indicators was not significant (P>0.05). There were significant differences in varus/valgus and internal rotation/external rotation between healthy and affected sides at 3 weeks before operation (P<0.05), and the differences in other indicators was not significant (P>0.05). At 7 months after operation, the difference in the forward and backward displacement of medial tibia contact center was significant (t=3.798, P=0.007), and the differences in other indicators was not significant (P>0.05). Conclusion UKA can effectively correct the varus and valgus of the knee joint, and restore the rotational biomechanical characteristics of the affected knee joint. It does not affect the establishment of the lateral compartment joint space, but the medial and lateral tibia contact center still changes.

    Release date:2021-10-28 04:29 Export PDF Favorites Scan
32 pages Previous 1 2 3 ... 32 Next

Format

Content