west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "left ventricular" 44 results
  • Surgical strategies of atrioventricular septal defect with left ventricular outflow tract stenosis: Clinical outcome of single center

    ObjectiveTo explore the anatomical characteristics and surgical strategies of atrioventricular septal defect (AVSD) with left ventricular outflow tract (LVOT) stenosis.MethodsThe clinical data of 11 AVSD patients with LVOT stenosis who underwent surgeries in our hospital from 2008 to 2019 were retrospectively analyzed, including 6 males and 5 females with a median age of 15.0 (7.6-22.0) years.ResultsThere were 3 patients of complete AVSD and 8 patients of partial AVSD. Subaortic stenosis resulted from discrete subaortic membrane in 3 patients, diffused subaortic membrane in 4 patients, hypertrophied muscle bundles in 3 patients and distorted valve frame in 1 patient. Among these patients, 5 patients underwent LVOT stenosis and AVSD repairs simultaneously for the first time, 5 patients underwent LVOT stenosis repair for the second time and 1 patient for the third time. No postoperative death occurred. The postoperative LVOT flow velocity decreased dramatically after LVOT stenosis repair compared with preoperative one [449.0 (393.0, 507.5) cm/s vs. 212.0 (183.0, 253.5) cm/s, P<0.05].ConclusionSurgical results of AVSD combined with LVOT stenosis are satisfactory, but the restenosis should be paid attention to via long-term follow-up.

    Release date:2021-09-18 02:21 Export PDF Favorites Scan
  • Value of transthoracic echocardiography to monitor and evaluate aortic insufficiency after implantation of left ventricular assist device

    ObjectiveTo explore the value of transthoracic echocardiography (TTE) to monitor and evaluate aortic insufficiency (AI) within one year after the implantation of the left ventricular assist device (LVAD).MethodsWe retrospectively collected and analyzed the TTE data of 12 patients who received LVAD implantation from 2018 to 2020 in our hospital. All patients were males, with an average age of 43.3±8.6 years. We analyzed temporal changes in the aortic annulus (AA), aortic sinus (AoS), ascending aorta (AAo), the severity of AI and the opening of aortic valve before operation and 1 month, 3 months, 6 months and 12 months after LVAD implantation.ResultsAll 12 patients survived within 1 year after LVAD implantation. One patient was bridged to heart transplantation 6 months after implantation, and two patients did not receive TTE after 3 and 6 months. Compared to pre-implantation, AoS increased at 1 month after implantation (31.58±5.09 mm vs. 33.83±4.69 mm). The inner diameters of AA, AoS and AAo increased at 3, 6 and 12 months after LVAD implantation compared to pre-implantation (P<0.05), but all were within the normal range except for one patient whose AoS slightly increased before operation. After LVAD pump speed was adjusted, the opening of aortic valve improved. The severity of AI increased at 6 and 12 months after LVAD implantation compared to pre-implantation, and increased at 12 months compared to 6 months after LVAD implantation (P<0.05).ConclusionTTE can evaluate aortic regurgitation before and after LVAD implantation and monitor the optimization and adjustment of LVAD pump function, which has a positive impact on the prognosis after LVAD implantation.

    Release date:2021-07-02 05:22 Export PDF Favorites Scan
  • Current status and progress of implantable left ventricular assist devices

    Implantable left ventricular assist device (LVAD) has become an essential treatment for end-stage heart failure, and its effect has been continuously improved. In the world, magnetic levitation LVAD has become mainstream and is increasingly used as a destination treatment. China has also entered the era of ventricular assist device. The continuous improvement of the ventricular assist device will further improve the treatment effect. This article reviews the current situation and development trend of LVAD treatment in China and abroad.

    Release date:2023-08-31 05:57 Export PDF Favorites Scan
  • Effect of transcatheter aortic valve replacement on postoperative left ventricular reverse remodeling in patients with aortic regurgitation

    Objective To investigate the left ventricular reverse remodeling (LVRR) in patients with aortic valve insufficiency with reduced ejection fraction (AIrEF) and aortic valve insufficiency with preserved ejection fraction (AIpEF) after transcatheter aortic valve replacement (TAVR). MethodsThe clinical and follow-up data of patients who underwent TAVR in the Department of Cardiothoracic Surgery, Xinhua Hospital Affiliated to Shanghai Jiao Tong University School of Medicine from 2018 to 2021 were retrospectively analyzed. According to the guideline, the patients with left ventricular ejection fraction<55% were allocated to an AIrEF group, and the patients with left ventricular ejection fraction≥55% were allocated to an AIpEF group. ResultsA total of 50 patients were enrolled. There were 19 patients in the AIrEF group, including 15 males and 4 females with a mean age of 74.5±7.1 years. There were 31 patients in the AIpEF group, including 19 males and 12 females with a mean age of 72.0±4.8 years. All patients underwent TAVR successfully. Echocardiographic results showed that TAVR significantly promoted LVRR in the patients. Significant LVRR occurred in the early postoperative period (the first day after the surgery) in both groups. It remained relatively stable after the LVRR in the early postoperative period (the first day after surgery) in the AIpEF patients, while it continued to occur in the early postoperative period (the first day after surgery) to three months after the surgery in the AIrEF patients, and then remained relatively stable. Compared to preoperative values, AIrEF patients had a reduction in the average left ventricular end-diastolic volume index and left ventricular end-systolic volume index by 16.8 mL/m2 (P=0.003) and 8.6 mL/m2 (P=0.005), respectively, and the average left ventricular end-diastolic diameter index and end-systolic diameter index decreased by 2.5 mm/m2 (P=0.003) and 1.9 mm/m2 (P=0.003), respectively on the first day after the surgery. In comparison to the first day after the surgery, AIrEF patients experienced an average increase of 12.1% in the left ventricular ejection fraction three months after the surgery (P<0.001). ConclusionTAVR has achieved good therapeutic effects in patients with aortic valve insufficiency, significantly promoting the LVRR in patients, and has better curative effects in AIrEF patients.

    Release date:2023-07-25 03:57 Export PDF Favorites Scan
  • Multiple factors analysis on the recovery of left ventricular ejection fraction in the revascularized patients with ischaemic cardiomyopathy

    Objective We probed how to predict left ventricular ejection fraction (LVEF) of the ischaemic cardiomyopathy (ICM) patients would be improved apparently after revascularization. Methods Between July 2010 and December 2015, 245 ICM patients (30%≤LVEF≤40%) with coronary bypass grafting (CABG) were retrospectively observed. Among them, 146 patients were accompanied by ischemic mitral regurgitation (IMR) (146/245, 59.6%), and 41 patients underwent mitral valvuloplasty or replacement because of more than moderate IMR. There were 13 patients early death, and other 232 patients who were followed up over 6 months were divided into two groups based on whether or not post-operative LVEF increased by 10%: a LVEF recovered group (group A, 124 patients) and a non-recovered group (group B, 108 patients). Results Preoperative NT-proBNP in the group A was significantly higher than that in the group B (P=0.036). There were less patients with myocardial infarction in the group A than that in the group B (P=0.047), and more with angina pectoris in the group A than that in the group B (P=0.024). There was no significant difference in the extent of mitral regurgitation or mitral surgery between the groups A and B (P>0.05). There were lower left ventricular end-diastolic diameter (LVEDD), left ventricular end-systolic diameter (LVESD) and left ventricular end-diastolic volume (LVEDV) in the group A than those in the group B (P<0.05). Multivariate analysis revealed that preoperative LVEDD dilated apparently and no angina pectoris existed before surgery were independent risk factors for LVEF with no recovery in the ICM patients (30%≤LVEF≤40%) after revascularization. The LVEDD of 245 patients (including 13 early deaths) was 41-71 mm. We found that the ICM patients with LVEDD ≥60 mm were more likely to signify the unfavourable prognosis (χ2=8.63, P=0.003, OR=2.21, 95% confidence interval 1.25 to 3.91). Conclusion Preoperative LVEDD dilated and no angina pectoris before surgery are independent risk factors for LVEF with no recovery in the ICM patients (30%≤LVEF≤40%) after revascularization. LVEDD≥60 mm can be regarded as the preoperative forecasting factors for the unfavourable prognosis in the ICM patients (30%≤LVEF≤40%) after revascularization.

    Release date:2018-11-27 04:47 Export PDF Favorites Scan
  • Study on regurgitation using the coupling model of left ventricular assist device and cardiovascular system

    Regurgitation is an abnormal condition happens when left ventricular assist devices (LVADs) operated at a low speed, which causes LVAD to fail to assist natural blood-pumping by heart and thus affects patients’ health. According to the degree of regurgitation, three LVAD’s regurgitation states were identified in this paper: no regurgitation, slight regurgitation and severe regurgitation. Regurgitation index (RI), which is presented based on the theory of dynamic closed cavity, is used to grade the regurgitation of LVAD. Numerical results showed that when patients are in exercising, resting and sleeping state, the critical speed between slight regurgitation and no regurgitation are 6 650 r/min, 7 000 r/min and 7 250 r/min, respectively, with corresponding RI of 0.401, 0.300 and 0.238, respectively. And the critical speed between slight regurgitation and severe regurgitation are 5 500 r/min, 6 000 r/min and 6 450 r/min, with corresponding RI of 0.488, 0.359 and 0.284 respectively. In addition, there is a negative relation correction between RI and rotational speed, so that grading the LVAD’s regurgitation can be achieved by determining the corresponding critical speed. Therefore, the detective parameter RI based on the signal of flow is proved to be able to grade LVAD’s regurgitation states effectively and contribute to the detection of LVAD’s regurgitation, which provides theoretical basis and technology support for developing a LVADs controlling system with high reliability.

    Release date:2017-10-23 02:15 Export PDF Favorites Scan
  • Analysis of preoperative left ventricular dysfunction and perioperative complications in coronary artery bypass grafting: A case control study

    Objective To identify the relationship between preoperative left ventricular dysfunction and perioperative risk factors in coronary artery bypass grafting (CABG). Methods The clinical data of 192 patients who underwent CABG from November 2015 to October 2016 were analyzed retrospectively. The patients were divided into three groups by preoperative left ventricular ejection fraction (LVEF) in echocardiography: a serious left ventricular dysfunction group (LVEF≤35%, 23 patients, 15 males and 8 females at age of 63.91±5.36 years), a moderate left ventricular dysfunction group (35%<LVEF<50%, 24 patients, 20 males and 4 females at age of 66.29±6.03 years) and a normal left ventricular function group (LVEF≥50%, 145 patients, 86 males and 59 females at age of 66.60±6.41 years). Results The overall mortality was 4.16% (8/192), 17.39% (4/23) in patients with LVEF≤35% and 2.76% (4/145) in those with LVEF≥50%. Preoperative LVEF≤35%, hypoxia, assisted circulation, acute kidney injury (AKI) and postoperative continuous renal replacement therapy (CRRT) were risk factors of perioperative mortality in coronary artery surgery. LVEF≤35% and CRRT were independent preditors of mortality. There were significant differences in mortality and postoperative complications between the serious left ventricular dysfunction group and other two groups. Conclusion Postoperative mortality and complications are obviously serious in the patients with LVEF≤35%. We should pay more attention to preoperative risk factors. Postoperative individual manipulation, intra-aortic balloon pump and CRRT can enhance survival of those patients.

    Release date:2018-05-02 02:38 Export PDF Favorites Scan
  • Research progress on the efficacy of novel oral anticoagulant for left ventricular thrombus

    Left ventricular thrombus (LVT) is a common complication of heart diseases such as myocardial infarction and heart failure. Vitamin K antagonist (VKA) is currently the main method for LVT, but its use requires frequent monitoring of coagulation indicators, which may lead to poor patient compliance. The novel oral anticoagulant (NOAC) is easy to administer and does not require monitoring of international normalized ratio or dietary restrictions. With the development of NOAC, the position of VKA for LVT may gradually be replaced in the future. This article provides a review of the comparative efficacy of NOAC and VKA for LVT in recent years, in order to provide new ideas for the clinical use of NOAC for LVT.

    Release date:2025-04-27 01:50 Export PDF Favorites Scan
  • Original Study of A Long-term Aortic Valve Pump of 23mm Outer Diameter, Weighing 31g

    Objective To investigate the feasibility of a long-term left ventricular assist device placed in the aortic valve annulus for terminal cardiopathy. Methods An implantable aortic valve pump (23ram outer diameter, weighing 31g) was developed. There were a central rotor and a stator in the device. The rotor was consisted of driven magnets and an impeller, the stator was consisted of a motor coil with an iron core and outflow guide vanes. The device was implanted identical to an aortic valve replacement, occupying no additional anatomic space. The blood was delivered directly from left ventricle to the aortic root by aortic valve pump like natural ventricle, neither connecting conduits nor "bypass" circuits were necessary, therefore physiologic disturbances of natural circulation was less. Results Aortic valve pump was designed to cycle between a peak flow and zero net flow to approximate systole and diastole. Bench testing indicated that a blood flow of 7L/min with 50 mmHg(1kPa = 7.5mmHg) pressure could be produced by aortic valve pump at 15 000r/min. A diastole aortic pressure of 80mmHg could be maintained by aortic valve pump at 0L/min and the same rotating speed. Conclusions This paper exhibits the possibility that an aortic valve pump with sufficient hemodynamic capacity could be made in 23mm outer diameter, 31g and it could be implantable. This achievement is a great progress to extend the applications of aortic valve pump in clinic and finally in replacing the natural donor heart for heart transplantation. Meanwhile, this is only a little step, because many important problems, such as blood compatibility and durability, require further investigation.

    Release date:2016-08-30 06:22 Export PDF Favorites Scan
  • Dissipative energy loss within the left ventricle detected using vector flow mapping technology in hypertension

    We have tried to explore the energy loss (EL) within the left ventricle in hypertension by using vector flow mapping (VFM) to detect left ventricular hemodynamic changes in hypertensive patients as early as possible and reflect changes of left ventricular function in hypertension by using EL. Twenty-one hypertensive patients with increased left ventricle mass index (LVMI), 14 hypertensive patients with normal LVMI and 22 control subjects were enrolled in this study. Systolic and diastolic EL derived from VFM within the left ventricle and E/e' by dual Doppler were recorded and analyzed. Compared with those of the controls, diastolic and systolic EL were significantly increased in hypertensive group (P<0.05). In diastole, EL=0.439×SBP (systolic blood pressure)–8.349; in systole, EL=0.385×SBP+0.644×LVMI–10.854. And the EL was positively correlated with E/e', but there was no significant correlation between EL and ejection fraction (EF) in the pooled population. The study shows that the increased EL can help us detect changes of left ventricular hemodynamic in hypertensive patients. It needs further investigation to prove whether EL within the left ventricle could be a new parameter to evaluate diastolic function. SBP and LVMI are the independent predictors for systolic EL, while SBP is the independent predictor for diastolic EL.

    Release date:2017-04-13 10:03 Export PDF Favorites Scan
5 pages Previous 1 2 3 4 5 Next

Format

Content