ObjectiveTo investigate the surgical skills and clinical effects of the laparoscopic transabdominal preperitoneal (TAPP) inguinal hernia repair in treatment of recurrent inguinal hernia with plug prefix mesh. MethodsThe clinical data such as operation time, intraoperative blood loss, postoperative hospital stay, and postoperative complications of 87 patients with recurrent inguinal hernia reoperated in laparoscopic TAPP after inguinal hernioplasty with plug prefix mesh (recurrent hernia group), in the Department of Gastroenterology and Hernia surgery of the First Affiliated Hospital of Kunming Medical University from January 2011 to December 2013, were retrospectively analyzed, which were compared with the 834 incipient inguinal hernia patients operated first by TAPP (incipient hernia group) at the same time. ResultsThe operations were completed successfully in all of the 921 patients without conversion to open surgery. The operation time and intraoperative blood loss in the recurrent hernia group were significantly more than those in the incipient hernia group (P=0.000, P=0.000), the postoperative hospital stay had no signifcant difference between two groups (P=0.057). No recurrences were observed in the recurrent hernia group and incipient hernia group for following-up of (31±4) months and (28±6) months, respectively. Compared with the incipient hernia group, the rates of postoperative pain on day 30 and seroma on day 1 and 3 were higher in the recurrent hernia group (P=0.001, P=0.040, P=0.003, respectively). There were no severe complications such as collateral damage, foreign body sensation, incision infection, intestinal obstruction and so on in the two groups. ConclusionsThe laparoscopic TAPP inguinal hernia repair is safe and effective for patients with recurrent inguinal hernia with plug prefix mesh. More skills are required to reduce the complications. The operation time and intraoperative blood loss in reoperated patients with recurrent inguinal hernia are more than those in patients with incipient inguinal hernia. The rates of seroma on day 1 and 3 are also higher.
Objective To observe the effect of biological fixation of femoral stem prosthesis with multilayer macropores coating by combined use of autologousbone grafting. Methods The reconstructing femoral stem prostheses were designed personally, proximal 2/3 surfaces of which were reformed by thick multilayer stereo pore structure. Twentyfour adult mongrel canines underwent right femoralhead replacement and were divided randomly into two groups. The autogenous bonemud of femoral head and neck were not used in the control group. The histologicexamination, roentgenograms and biomechanical test were carried out in the 1st,3rd and 6th month after operation to observe the bone formation and fixation inthe exterior and interior sides of the prostheses. Results Onthe whole view,bone reconstruction occurred in experimental group in the 3rd and 6th month. Roentgenograms also proved to be superior to the control group. Histological examinationshowed that both the maximum bone inserting depth(μm) and average engorging ratio(%) of newly formed bone in experimental group surpassed those in the control group. The maximum shear strength of prosthesisbone interface in experimental group was significantly higher than that in the control group(Plt;0.01). Conclusion Intensity of biological fixation can be strengthened remarkably by using femoral stem prothesis with multilayer macropores coating by combined use of autologous bone grafting.
Objective To explore the method and effectiveness of laparoscopic bundled fastigiated mesh in repairing inguinal hernia. Methods Between January 2003 and December 2009, 1 215 patients (1 363 sides) with inguinal hernia were treated. There were 1 132 males (1 268 sides) and 83 females (95 sides), aged from 18 to 89 years (median, 58 years). The cases included 1 187 cases (1 329 sides) of primary hernia and 28 cases (34 sides) of recurrent hernia. There were indirect inguinal hernia in 728 cases (786 sides), direct inguinal hernia in 416 cases (499 sides), femoral hernia in 43 cases (45 sides), and unusual hernia in 28 cases (33 sides). According to the hernia classification criteria, there were 31 cases (38 sides) in type I, 683 cases (754 sides) of type II, 403 cases (452 sides) of type III, and 98 cases (119 sides) of type IV. The disease duration was 1 to 9 days with an average of 3.8 days. To repair the hernia, the bundled fastigiated mesh was patched through the internal inguinal ring and fixed on the internal inguinal fascia by three-point fixation. The mesh would be wrapped in the peritoneum by purse-string suture. Results The surgeries were performd successfully. The operative time ranged from 18-32 minutes (mean, 22 minutes). Postoperative tractional pain in the inguinal region occurred in 19 cases (21 sides), acute uroschesis in 8 cases, and far-end hernial sac effusion in 2 cases (2 sides); all were cured after symptomatic treatment. All incisions healed by first intention, and no complications of fever, infection, or hematoma occurred. A total of 1 095 cases (1 182 sides) were followed up 1 to 7 years (median, 3 years and 9 months). Five patients died of medical illnesses at 1-3 years after operation. Three cases recurred and then were cured by a second surgery. No intestinal adhesion or obstruction occurred. Conclusion The bundled fastigiated mesh in laparoscopic inguinal hernia repair has the advantages of minimal invasiveness, easy-to-operate, less complications, and lower recurrence rate.
Objective To compare the effect of small intestinal submucosa(SIS)and polypropylene mesh(PPM) on repairing abdominal wall defects in rats, and toprobe into the feasibility of using SIS to repair the abdominal wall defects. Methods 100 SD rats(50 males and 50 females)were randomly divided into 2 groups(n=50). Their weight ranged from 200 to 250 g.Full thickness abdominal wall defects (2 cm×2 cm) were created by surgery and were repaired with SIS and PPM respectively. At different postoperative time (1st, 2nd, 4th, 8th and 12th week), animals were sacrificed to make histological observation. The tensile strengthand the development of adhesions were measured and observed. Results 95 animals survived and were healthy after surgery. No inflammatory response and obvious immunoreaction were observed in both groups. One week after operation, the tensile strengthof abdominal wall in SIS group (204.30±5.13 mmHg) was lower than that in PPMgroup(240.0±10.0 mmHg) at 1st week(P<0.05),and there were no difference at 4th, 8th, 12th week. Adhesions were more marked in PPM group thanthat in SIS group(P<0.05). Conclusion Both SIS and PPM are histologically compatible when used in rats and can maintain sufficient tensile strength. SIS is superior to PPM in regards to tissue compatibility and adhesion formation.
Objective To investigate the effectiveness of laparoscopic Y-shaped polypropylene mesh in the treatment of uterine and vaginal vault prolapse. Methods Between June 2010 and December 2012, 24 patients with uterine and vaginal vault prolapse were treated by laparoscopic pelvic reconstruction (vagina and uterus-sacral fixation) with Y-shaped polypropylene mesh. The age of patients was 35-60 years (mean, 48.6 years). The disease duration was 2-8 years (mean, 5 years). According to the pelvic organ prolapse quatitative (POP-Q) classification by International Continence Society (ICS), 16 cases were classified as uterine prolapsed degree II and 8 cases as degree III; 15 cases were classified as vaginal prolapse degree I, 7 cases as degree II, and 2 cases as degree III. All patients received postoperative follow-up regularly. Subjective evaluation was done based on prolapse quality of life questionnaire (P-QOL), and objective evaluation based on POP-Q classification. Results All the patients were operated successfully. The operation time was 22-68 minutes (mean, 33 minutes); the blood loss was 30-80 mL (mean, 51 mL); the indwelling urethral catheter remain was 3-7 days (mean, 4 days); and the hospitalization days were 4-9 days (mean, 6.8 days). Twenty-four patients were followed up 3-12 months (mean, 9 months), of whom, 2 were followed up less than 6 months. All patients had normal urination after withdrawal of urethral catheter, and the residual urine volume was in normal range. No patients had mesh erosion and discomfort during sex, vaginal and anal bearing down. The P-QOL scores at 3, 6, and 12 months after operation were significantly improved when compared with the preoperative value (P lt; 0.05); but there was no significant difference among 3, 6, and 12 months after operation (P gt; 0.05). The postoperative POP-Q classification was degree 0 in 19 cases and degree I in 3 cases, and the objective cure rate was 91.7%. No recurrence was found during follow-up. Conclusion Laparoscopic Y-shaped polypropylene mesh for treatment of uterine and vaginal vault prolapse is a safe and effective method, especially applicable to preserve the uterus, and higher requirements of sexual life of patients.
ObjectiveTo compare the clinical efficacy of abdominal preperitoneal laparoscopic hernia repair with 3DMax patch and plain film for treatment of inguinal hernia. MethodsThe clinical and follow-up survey data of 120 patients with inguinal hernia in The Second Affiliated Hospital of Harbin Medical University, between January 2009 and May 2014, which were treated by laparoscopic transabdominal preperitoneal repair (TAPP) were retrospectively analyzed. One hundred and twenty cases were divided into two groups:plain film group (45 cases) and 3DMax group (75 cases) according to the intraoperative use of different patchs. The patches of 3DMax group were not fixed, the patches of plain film group were fixed with metal nails. The postoperative clinical effect of two groups were analyzed. ResultsThe operative time, intraoperative blood loss, and postoperative hospitalization days of two groups were no statistical significance (P > 0.05). The postoperative off bed activity time of patients in 3DMax group and plain film group was (20.2±8.1) h and (26.3±9.2) h, respectively, the average off bed activity time in 3DMax group was significantly earlier than that in plain film group (P=0.041). The material expenses and hospitalization expenses of the 3DMax group were significantly lower than those of the plain film group (P=0.001, P=0.038). The incidence of foreign body sensation of inguinal region in 1, 3, and 9 months after operation of 3DMax group were lower than those of plain film group (P=0.045). The VAS score in 1 and 3 months after operation of 3DMax group were lower than those of plain film group (P < 0.05), but there was no statistically significant in 6 months after operation of 2 groups (P > 0.05). There was no recurrence case in two groups. ConclusionsThe use of 3DMax patch in laparoscopic TAPP operation have more simple operation, hospitalization expenses decreased, recovery faster, postoperative inguinal nerve pain and foreign body sensation more lighter, and complications more less. It is worthy of clinical popularization and Application.
Test of tissue tolerance to domastic prosthetic materials (carbon fiber mesh, siliconized velvet, silk cloth and dacron cloth) as a subcutaneos transplant was performed in the adcominal wall of rabbit. These implants and their surroundding tissues were excied for studies at second , fourth, eighth and the twelfth weeks after operation. Ratio of fibroblast count to inflammatory cells count which is a common parameter of tissue tolerance was calculated in these four groups. The result shows that fibroblastic cell reaction elicited by carbon fiber mesh is the greates among the four prosthetic materials, the second one is dasron cloth. The inflammatory cell reaction elicited by silk is the greatest among the four materials, the second is carbon fiber mesh, and the dacron cloth the least. Tissure tolerance of dacron cloth is the best in the four prosthetic materials for implantation while sick is the worst.
ObjectiveTo analyze and identify the pathogenic mutation that caused a case of child’s renal coloboma syndrome (RCS).MethodsA child with congenital cataract in the right eye and optic disc defect in the left eye and his parents with normal phenotype were included in the study. The blood of the child and his parents were captured to extract DNA and make molecular test. The possible variants were screened through NGS sequencing using the ophthalmology gene panel on illumina NextSeq 500 platform, and proved the selected PAX2 mutation by Sanger sequencing. Pathogenicity report was retrieved through PubMed and related database. Pathogenicity analysis of the candidate mutated site has careful consideration of the patient’s clinical presentations and sequencing result base on Standards and Guidelines for the Interpretation of Sequence Variants revised by ACMG. According to the results of gene diagnosis, the child was executed related clinical examinations on kidney.ResultsThe sequence result showed that a heterozygous mutation in PAX2, c.70dupG (p.V26Gfs*28), which lead to truncated protein product that terminated after 28 amino acids of the mutated site. Both of his normal parents were not carriers of the heterozygous mutation. Sanger sequencing results of the child and his parents were consistent with the NGS sequencing. The autosomal dominant disease phenotype was inferred to be caused by the heterozygous mutation of c.70dupG (p.V26Gfs*28) of PAX2 gene. Renal color Doppler ultrasound results showed the child with small renal cysts on the left and mildly separated collecting system. Renal function tests showed the child with α1 microglobulin index increased.ConclusionThe heterozygous mutation c.70dupG (p.V26Gfs*28) in PAX2 is the genetic pathogenic cause for the patient with RCS.
Objective To evaluate the biomechanical characteristicsof titanium mesh with anterior plate fixation or ilium autograft in anterior cervical decompression.Methods Six fresh cervical spine specimens(C3-7) of young cadaver were used in the biomechanical test. After C5, C5,6 and C4-6 were given vertebrectomy,ilium autograft and titanium mesh with anterior plate fixation were performed. Their stabilities of flexion,bilateral axial rotation,the lateral bending and the extension were tested. Intact cervical spine specimens served as control group. Results Ilium autograft improved the stability of the unstable cervical vertebrae and decreased the flexion, the lateral bending or the extension, showing a significant difference when compared with control group(Plt;0.05). Whereas, axial rotational motion was decreased insignificantly(Pgt;0.05). Titanium meshwith anterior plate fixation improved the stability of the unstable spine and decreased the flexion,the bilateral axial rotation,the lateral bending or the extension, showing a significant difference when compared with control group(Plt;0.05). Conclusion The vertebrectomy and anterior cervical fusion by ilium autograft was the least stable construct of all modes tested,and the titanium mesh implantation is stabler than the intact cervical sample.
Objective To summarize the therapeutic experiences of abdominal wall bulge repair with compound patch intraperitoneal placement. Methods From October 2005 to October 2008, intraperitoneal onlay mesh with compound patch applied in 7 patients with abdominal wall bulge, whose clinical data were analyzed retrospectively. Results All the procedures were performed successfully, including 5 open operation and 2 laparoscopic repair. The mean operation time was 85 min (ranged 68 to 130 min). After operation, 1 seroma formation and 1 hemorrhage in the thoracic cavity developed and were cured with the conservative therapy. Mean postoperative hospital stay was 9.5 d (ranged 8 to 16 d). There was no recurrence, infection, or prolonged pain during 1-4 years follow-up. Conclusion Abdominal wall bulge is caused by the weakness of abdominal wall muscle, and the intraperitoneal onlay mesh repair with compound patch is an appropriate therapy.