west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "minimally invasive treatment" 4 results
  • Intelligent monitoring system assisted pelvic fracture closed reduction for treating one case with complex pelvic fracture

    ObjectiveTo introduce the experience of intelligent monitoring system assisted pelvic fracture closed reduction to treat complex pelvic fracture in a minimally invasive method.MethodsA 30-year-old male patient with complex pelvic fracture caused by a falling injury was treated in December 2019. The pelvic fracture was diagnosed by X-ray film and CT three-dimensional reconstruction. The AO/Orthopaedic Trauma Association (AO/OTA) classification was 61-C3.3 type (H-shaped sacrum fracture with pubic symphysis separation). At 48 hours after injury, the vital signs were stable, and the operation was performed. The pelvic fracture was reduced with the help of pelvic reduction frame and skeletal traction, the intelligent monitoring system, and fixed with the channel screws.ResultsThe intraoperative blood loss was 50 mL, the operation time was 180 minutes, and the fluoroscopy time was 45 seconds. The incision healed well after operation. The X-ray film of pelvis was taken on the next day after operation, and the fracture reduction was evaluated as anatomical reduction according to Matta standard; CT three-dimensional reconstruction showed that the fixation screws were all located in the cortex of bone, without penetrating the cortex of bone.ConclusionThe intelligent monitoring system assisted pelvic fracture closed reduction is reliable in the minimally invasive treatment of complex pelvic fractures, which can achieve good results and reduce intraoperative fluoroscopy.

    Release date:2020-07-27 07:36 Export PDF Favorites Scan
  • Early effectiveness of computer navigation system-assisted transiliac-transsacral screws placement for posterior pelvic ring injuries

    Objective To investigate the early effectiveness of transiliac-transsacral screws internal fixation assisted by augmented reality navigation system HoloSight (hereinafter referred to as “computer navigation system”) in the treatment of posterior pelvic ring injuries. MethodsA retrospective analysis was made in the 41 patients with posterior pelvic ring injuries who had been treated surgically with transiliac-transsacral screws between June 2022 and June 2023. The patients were divided into navigation group (18 cases, using computer navigation system to assist screw implantation) and freehand group (23 cases, using C-arm X-ray fluoroscopy to guide screw implantation) according to the different methods of transiliac-transsacral screws placement. There was no significant difference in gender, age, body mass index, causes of injuries, Tile classification of pelvic fracture, days from injury to operation, usage of unlocking closed reduction technique between the two groups (P>0.05). The time of screw implantation, the fluoroscopy times, the guide wire adjustment times of each screw, and the incidence of complications were recorded and compared between the two groups. The position of the transiliac-transsacral screw was scanned by CT within 2 days after operation, and the position of the screw was classified according to Gras standard. ResultsThe operation was successfully completed in both groups. The time of screw implantation, the fluoroscopy times, and the guide wire adjustment times of each screw in the navigation group were significantly less than those in the freehand group (P<0.05). There were 2 cases of incision infection in the freehand group, and the incision healed by first intention after active dressing change; there was no screw-related complication in the navigation group during operation and early period after operation; the difference in incidence of complications between the two groups (8.7% vs. 0) was not significant (P=0.495). According to the Gras standard, the screw position of the navigation group was significantly better than that of the freehand group (P<0.05). ConclusionCompared with the traditional freehand method, the computer navigation system assisted transiliac-transsacral screws internal fixation in the treatment of posterior pelvic ring injuries has advantages of improving the accuracy of screw implantation and reducing radiation damage and the time of screw implantation.

    Release date: Export PDF Favorites Scan
  • Short-term effectiveness of minimally invasive treatment for posterolateral depressed tibial plateau fractures assisted by robots and arthroscopy

    Objective To investigate short-term effectiveness of robot-assisted fracture reduction and fixation combined with arthroscopic exploration for posterolateral depressed tibial plateau fractures. Methods Between January 2022 and January 2024, 8 patients with posterolateral depressed tibial plateau fractures (Schatzker type Ⅲ) were treated using robot-assisted fracture reduction and fixation combined with arthroscopic exploration, with simultaneous treatment of concomitant ligament or meniscus tears. There were 3 males and 5 females with an average age of 54.1 years (range, 42-68 years). Injury mechanisms included traffic accidents (3 cases) and falls (5 cases). The time from injury to operation ranged from 2 to 4 days (mean, 3.1 days). Operation time, intraoperative blood loss, hospital stay duration, visual analogue scale (VAS) score for pain, and complications were recorded. Fracture healing and knee Rasmussen scores were assessed radiographically, while knee function was evaluated using range of motion and Hospital for Special Surgery (HSS) scores. Results All operations were successfully completed. The operation time was 108-129 minutes (mean, 120.1 minutes). The intraoperative blood loss was 10-100 mL (mean, 41.3 mL). The hospital stay duration was 4-7 days (mean, 5.6 days). All incisions healed by first intention without complication such as peroneal nerve injury, vascular damage, or infection. All patients were followed up 32-48 weeks (mean, 40 weeks). Radiographic follow-up confirmed that the knee Rasmussen scores rated as excellent in 8 patients and all fractures healed with the healing time of 12-16 weeks (mean, 13.5 weeks). The VAS score for pain was 2-4 (mean, 2.8) at discharge and improved to 0 at 1 month after operation. The knee range of motion was 80°-110° (mean, 96.1°) at discharge and increased to 135°-140° (mean, 137.9°) at 1 month after operation. At 3 months after operation, the HSS score was 91-94 (mean, 92.8), all graded as excellent. No severe complication, including implant failure, occurred during follow-up. Conclusion For posterolateral depressed tibial plateau fractures, the minimally invasive approach combining robot-assisted fracture reduction and fixation with arthroscopic exploration demonstrates multiple advantages, including shorter operation time, reduced intraoperative blood loss, excellent wound healing, fewer complications, and rapid recovery of knee function. This technique achieves satisfactory short-term effectiveness, while its long-term effectiveness requires further evaluation.

    Release date: Export PDF Favorites Scan
  • Effectiveness analysis of Zhang’s double reverse traction reducer in minimally invasive treatment of bilateral tibial plateau fractures

    Objective To evaluate the effectiveness and safety of minimally invasive treatment for bilateral tibial plateau fractures using the double reverse traction reducer. Methods The clinical data of 4 patients with bilateral tibial plateau fractures who met the selection criteria and treated between January 2016 and April 2024 were retrospectively analyzed. The cohort included 3 males and 1 female, aged 30-65 years (mean, 52.5 years). Injury mechanisms comprised traffic accidents (2 cases) and falls (2 cases). According to the Schatzker classification, 2 limbs were type Ⅱ and 6 were type Ⅵ. The time from injury to surgery ranged from 5 to 9 days (mean, 7 days). All patients underwent minimally invasive reduction using the double reverse traction reducer. Surgical duration, intraoperative blood loss, and hospitalization time were recorded. Functional outcomes were assessed at last follow-up using the Hospital for Special Surgery (HSS) knee score and range of motion (ROM), while fracture reduction quality was evaluated using the Rasmussen radiological score. Results All 4 patients successfully completed the procedure without conversion to open reduction. The total mean operation time was 80.25 minutes (range, 73-86 minutes), with a mean total intraoperative blood loss of 132.5 mL (range, 100-150 mL). The mean hospitalization time was 13.5 days (range, 11-16 days). All incisions healed primarily without neurovascular complications. X-ray film at 1 day after operation confirmed satisfactory reduction and articular surface alignment. Follow-up time ranged from 12 to 26 months (mean, 17.0 months). Fractures achieved clinical union at an average of 13 weeks (range, 12-16 weeks). No complication, such as deep vein thrombosis, joint stiffness, post-traumatic arthritis, or implant failure, was observed. At last follow-up, the mean HSS score was 92.9 (range, 90-97), mean knee ROM was 128.1° (range, 115°-135°), and mean Rasmussen radiological score was 16.4 (range, 15-19), with 2 limbs rated as excellent and 6 as good. Conclusion The double reverse traction reducer facilitates minimally invasive treatment of bilateral tibial plateau fractures with advantages including minimal trauma, shorter surgical duration, precise reduction, and fewer complications, effectively promoting fracture healing and functional recovery of the knee joint.

    Release date: Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content