west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "plasty" 807 results
  • REPLACEMENT OF INVERT-TYPE ARTIFICIAL TOTAL SCAPULA AND SHOULDER JOINT PROSTHESIS FOR MALIGNANT TUMOR

    Objective To estimate the clinical curative effect of replacement of inverttype artificial total scapula and shoulder joint prosthesis and reserving arm with rehabilitation of function in the treatment of malignant tumor in shoulder. Methods From February 2001 and November 2004, five youth patients with primary malignant shoulder tumors were treated operatively by resection of neoplasmsthoroughly, replacement of inverttype artificial total shoulder blade and joint prosthesis, the functional reconstruction. Of them, there were 4 males and 1 female, aging from 19 to 26 years with an average of 23.6 years. Two cases were diagnosed as having osteosarcoma, one as having chondrosarcoma, and 2 as having Ewing sarcoma. After operation, the upper limbs was immobilized for 3 weeks. The rehabilitation training including passive exercise and initiative exercise. Results The average operative time was 425 min (380 to 530 min), and the blood loss ranged from 1 250 ml to1 900 ml(1 540 ml on average). The follow-up ranged from 7 to52 onths,with an average of 24.6 months. Postoperative complication included 1 case of pneumothorax, one case of shoulder incision skin part necrosis and 1 case of clavicle stump raising and pierce skin with shallow infection. No complication of postoperative incision deeply infection, nerve damage and prosthesis exposure or dislocation occurred. According to the scoring system of JOA(Japan orthopaedics association), the average score was 65 (60 to 72). The flexion and extension function of elbow joint recovered to normal. Conclusion The replacement of inverttype artificial total scapula and shoulder joint prosthesis is an efficacious method for the treatment of malignant tumor in shoulder. There are advantages of numerous adaption, wide range of motion and goodstability. It can not only reserve arm but also rehabilitate function.

    Release date:2016-09-01 09:22 Export PDF Favorites Scan
  • RELATIONSHIP BETWEEN INITIAL STABILITY AND INFECTED LOOSENING OF TOTAL HIP ARTHROPLASTY PROSTHESIS

    Objective To investigate the relationship between the initial stabil ity and infected loosening of the total hip arthroplasty (THA) prosthesis. Methods From January 2000 to December 2008, 110 cases (110 hips) were treated with THA revision. Among them, 15 cases (15 hips) were confirmed infected loosening. There were 8 males and 7 females with anaverage age of 62 years (range 42-75 years). The infected signs were found from 6 months to 2 years after initial THA. All of them had Tsukayama type IV and late infection, including 6 cases of acetabular infected loosening (5 cases of one-stage and 1 case of two-stage acetabular revision), 7 cases of simple infected loosening of femoral prosthesis (4 cases of one-stage and 3 cases of twostage femoral prosthesis revision), and 2 cases of joint capsule infection and sinus without prosthesis loosening (debridement and continuous irrigation). Results All incisions healed by first intention. Fifteen patients were followed up for 12 to 36 months (average 24 months). In 13 cases of revision, postoperative X-ray films showed that femoral acetabular prostheses were in good position, and had no cl inical and imaging infective signs of loosening. In 2 cases of joint capsule infection, sinus recurred 6 months postoperation without hip joint pain, the function of weight-bearing and walking of hip joint was normal. Harris score increased from preoperative average of 42 to postoperative average of 85; the results were excellent in 4 cases, good in 7 cases, and fair in 4 cases. Conclusion The infection of THA may occur in the whole joint, half-joint or just in joint capsule. The initial stabil ity of the prosthesis would affect the long-term survival of the prothesis. If the prosthesis initial stabil ity is obtained, even if there are infective factors, infections would also be l imited.

    Release date:2016-08-31 05:47 Export PDF Favorites Scan
  • SHORT-TERM FOLLOW-UP OF RIBBED ANATOMIC CEMENTLESS TOTAL HIP ARTHROPLASTY

    Objective To summarize the clinical outcome of the Ribbed anatomic cementless total hip arthroplasty (THA) in the treatment of hip-joint disease. Methods From January 2001 to June 2005, 34 patients(38 hips) with hip-joint disease were treated with Ribbed anatomic cementless THA. Their ages ranged from 29 to 55 years with an average age of 42.7 years.The disease course was from 3 to 18 years. Among these cases, there were 7 cases (7 hips) of femoral neck fracture, 5 cases(5 hips) of traumatic arthritis after fracture of acetabulum, 15 cases(16 hips) of necrosis of the femoral head and 7 cases(10 hips) of ankylosing spondylitis. Four patients were operated on both hip joints. The average Harris hip score was 38.6(25-57) before operation. Results Twenty-one patients(23 hips) were followed up 861 months with an average of 35 months. The Harris hip score was 76-98 after operation with an average of 92.3, showing significant difference when compared with that before operation(Plt;0.05). The excellent and good result was achieved in 93.5 % of patients. Radiographs showed no prosthetic osteolysis and no evidence of loosening. Pain in the thigh occurred in 4 patients,and it can be relieved by using nonsteroid antiinflammatory drug. Conclusion Ribbed anatomic cementless THA has good clinical and radiographic results in treating patients with hip-joint disease.

    Release date:2016-09-01 09:22 Export PDF Favorites Scan
  • ANALYSIS OF THE COMPLICATION ABOUT SILICONE GEL IMPLANTS IN AUGME NTATION MAMMAPLASTY

    Along with the wide application of silicone gel implants in augmentation mammaplasty, more complications appeared. The author reported 24 cases of complicationssince 1989, including one case of heamtoma, one case of infection, two cases of injury of the sensory nerves to the nipple, four cases of asymmetric breast (as ymmetry in position and size), three cases of deformed appearance, six cases of constracture of the fibrous coating membrane, one case of rupture of prosthesis,one case of sinus formation and three cases of abnormal milk secretion. The causes of the complications and their prevention were discussed.

    Release date:2016-09-01 11:16 Export PDF Favorites Scan
  • PRELIMINARY EXPERIENCES IN MINIMALLY INVASIVE AND MINIINCISION SURGERY TOTAL HIP ARTHROPLASTY FOR LATE OSTEONECROSIS OF THE FEMORAL HEAD

    Objective To explore the effect of minimally invasive and mini-incision surgery (MIS) in total hip arthroplasty (THA) on late osteonecrosis of femoral head (ONFH). Methods From March 2003, Eighteen patients (22 hips) with ONFH underwent MIS in THA. Their ages ranged from 24to 57 years, including 13 males and 5 females. The mean body mass index ranged from 17.1 to 30.1(24.6 on average). The Harris hip score was 46 points before operation. Modified posterior-lateral approach was adopted, and the MIS THA was performed by cementless prosthesis. As a comparison, 18 patients (22 hips) were performed by conventional THA at the same period. The data, including bleeding volume during operation, incision length, operative time, and postoperative function recovery, were compared. Results Follow-ups were done for 6 to 20 months (11 months on average). Dislocation occurred in one patient that underwent conventional THA 2 days after operation. No complication occurred in MIS THA group. The incision lengths ranged from 8.7 to 10.5 cm (9.3 cm on average) in MIS THA group, being statistically different (Plt;0.01). There was no significant difference in Harris scoring of the function between the two groups both before the operation and after the operation (Pgt;0.05). The operative time was almost the same, but the bleeding volume in MIS THA group was less (Plt;0.05). The function recovery was faster in MIS THA group.Conclusion The MIS THA is an alternative to the treatment of late ONFH. The advantages of MIS THA are fewer trauma, less bleeding volume, and faster recovery. The MIS THA should be performed by surgeons with rich experiences in THA and hospitals with necessary instruments. 

    Release date:2016-09-01 09:30 Export PDF Favorites Scan
  • A LONG-TERM FOLLOW-UP OF LUMBAR LAMINOTOMY AND REPLANTATION

    Objective To evaluate lumbar laminotomy and replantation in prevention of spinal unstability and peridural adhesion after laminectomy.Methods From February 1995 to March 2001,a total of 169 patients(96 males, 73 females,aged 22-63) with lesions in the lumbar vertebral canals underwent surgery, in which the lesions were removed afterlaminectormy and then the excised laminae were replanted. Results The follow-up for 5-9 years showed that all the patients had no complications after the lesions were removed. According to the evaluation criteria formulated by WANG Yongti,81 patients had an excellent result, 67 had a good result, 19 had a fair result, and2 had a poor result. 87.6% of the patients obtained quite satisfactory results.The X-ray films demonstrated that the replanted laminae obtained bony healing and the spine was stable. The CT scanning demonstratedthat the canals were enlarged with a smooth and glossy interior. Conclusion Lumbar laminotomy and replantation is reasonable in design and convenient in performance, which can be promoted as a basic operation in spinal surgery.

    Release date:2016-09-01 09:25 Export PDF Favorites Scan
  • ONE-STAGE RADICAL DEBRIDEMENT AND TOTAL HIP ARTHROPLASTY FOR TREATMENT OF ACTIVE TUBERCULOSIS OF THE HIP

    ObjectiveTo investigate the short-term effectiveness of one-stage radical debridement and total hip arthroplasty (THA) in the treatment of active tuberculosis of the hip. MethodsBetween January 2006 and June 2011,one-stage radical debridement and THA were performed on 12 cases (12 hips) of active tuberculosis of the hip.There were 7 males and 5 females,aged 18-60 years (mean,46.3 years).The disease duration ranged from 6 to 24 months (mean,10.5 months).According to Babhulkar and Pande staging criteria,5 cases were at stage Ⅲ and 7 cases were at stage IV.One case had sinus,and 2 cases had previous pulmonary tuberculosis.Preoperative hip range of motion was (35.83±9.25)°; hip Harris score was 36.83±6.44.Erythrocyte sedimentation rate (ESR) was 45-90 mm/1 h (mean,62.4 mm/1h); C-reactive protein (CRP) was 19-50 mg/L (mean,33.6 mg/L).Perioperatively all the patients accepted the regular anti-tuberculous medication. ResultsThe results of histopathological examination and PCR detection were positive for tuberculosis bacillus.Postoperatively the incisions healed primarily.All the patients were followed up 25-60 months (mean,40.8 months).The ESR and CRP returned to normal level with no liver injury.Tuberculosis recurrence occurred in 1 patient at 4 months after operation,which was cured after revision.X-ray film showed no prosthesis shift,prosthesis loosening,or sinus tract.At 18-24 months after operation,the bilateral sides had the same bone density,which was similar to that at the final follow-up.Hip range of motion was significantly improved to (107.08±13.56)° (t=14.571,P=0.000).Hip Harris score was significantly increased to 88.00±10.78 (t=16.750,P=0.000). ConclusionA combination of one-stage radical debridement and THA is a safe method to treat active tuberculosis of the hip,which can relief symptoms and improve hip function,with low recurrence and satisfactory short-term effectiveness.

    Release date: Export PDF Favorites Scan
  • ACCURACY IMPROVEMENT OF ACETABULAR COMPONENT PLACEMENT USING NONIMAGE BASED SURGICAL NAVIGATION SYSTEM

    Objective To improve the accuracy of the acetabular component placement using the nonimage based surgical navigation system. Methods Twenty-three patients (14 males, 9 females; age, 28-55 years;26 hips)with hip disease underwent the total hip arthroplasty (THA) using the nonimage based surgicalnavigation system from February 2004 to April 2006. Rheumatoid arthritis was found in 3 patients (3 hips), necrosis of the femoral head in 6 patients (6 hips), and osteoarthritis in 14 patients (16 hips). All the patients were randomly divided into the following 2 groups: the navigated group (11 patients, 13 hips), treated by THA using the nonimage based surgical navigation system; and the control group (12 patients, 13 hips), treated by the traditional THA. According to thedesign of the study, the acetabular component was placed in the best inclination angle (45°) and the anteversion angle (15°). The postoperative component position was examined. Results No fracture, dislocation, infection or injury to the sciatic nerve was found. In the navigated group, the inclination and the anteversion reached 15.4±1.4° and 45.5±1.3°, respectively. In the control group,the inclination and the anteversion were 13.9±7.6° and 43.7±6.4°, respectively. The inclination difference was considered statistically significant (Plt;0.01). All the patients were followed up for 10-40 months,averaged 26 months. In the navigated group, the postoperative average Harris hip score was 95 (range,85-110), with an excellent result in 11 hips and a good result in 2 hips. In the control group, the postoperative average Harris hip score was 92 (range,75-110), with an excellent result in 9 hips, a good result in 3 hips, and a fair result in 1 hip. The Harris hip score difference was considered statistically significant (Plt;0.05). There was a significantly better result obtained in the navigated group than in the control group. Conclusion The acetabular component can be implanted accurately by the nonimage based surgical navigation system, which can reduce the incidence of the loosening of the prostheses and has an important value in clinical practice.

    Release date:2016-09-01 09:20 Export PDF Favorites Scan
  • A BIOMECHANICAL STUDY ON POLYETHYLENE LINER CEMENTING INTO A FIXED ACETABULAR SHELL IN REVISION TOTAL HIP ARTHROPLASTY

    Objective To evaluate the strength of polyethylene l inercement interface when cementing a new linerinto a fixed acetabular cup in revision. Methods Twenty-five pairs of metal acetabular cups with polyethylene l iners were randomly divided into 5 groups: 1 group with standard locking device as control group (group A), other l iners were cemented into acetabular cups as 4 experimental groups. According to different intersection angles of metal acetabular cups with polyethylene liners and the polyethylene l iners with or without metal ball, the 4 experimental groups were no ball 0° group (group B), 0° group (group C), 10° group (group D), and 20° group (group E), metal acetabular cups intersected with polyethylene liners without metal ball in group B, with metal ball in groups C, D, and E, respectively. The lever-out biomechanical test reproduced in vivo failure mechanism was then performed to evaluate the lever-out failure strength of l iner-cement-metalcup interface. Results The values of l iver-out failure force were (626.68 ± 206.12), (915.04 ± 197.49), (449.02 ± 119.78),(814.68 ± 53.89), and (1 033.05 ± 226.44) N in groups A, B, C, D, and E, respectively, showing significant differences forcomparison among groups (F=8.989,P=0.000). The values of l iver-out failure force in groups B and E were significantlyhigher than that in group A (P lt; 0.05), but no significant difference was found between groups C, D and group A (P gt; 0.05).Conclusion Cementation of polyethylene l iner into a malposition shell meeting within 20° can provide enough fixed strength.

    Release date:2016-08-31 04:23 Export PDF Favorites Scan
  • A NEW METHOD TO REPAIR ARTERY INJURIES IN EXTREMITIES BY PHLEBOPLASTY OF BRANCHED VEIN GRAFT

    In order to develope a new method to overcome the difficulties in anastomosis of blood vessels with different diameter, phleboplasty was utilized at the join-point to expand the diameter of branched vein graft, with a funnel-shaped stoma formed consequently. After successfully experimented in fresh blood vessels in vitro, the method was practised clinically to repair injured arteries in extremities, with the outcome that phleboplasty of branched vein graft could enlarge the diameter by 1-1.25 times, and with satisfied effects in 3 clinic cases. So, the conclusion was that: phleboplasty of branched vein graft was a new effective and convinient method to repair injured arteries with different diameters

    Release date:2016-09-01 11:07 Export PDF Favorites Scan
81 pages Previous 1 2 3 ... 81 Next

Format

Content