west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "scapula" 13 results
  • COMBINED SCAPULAR/PARASCAPULAR BILOBAR FLAPS FOR RECONSTRUCTION OF SEVERE NECK CONTRACTURE

    Objective To discuss the reconstruction of severe neck contracture by transplanting combined scapular/parascapular bilobar flaps, and the probability to reestablish three-dimensional movement of the neck. Methods From January 2003 to November 2004, 9 cases of sustained severeneck contractures were treated (aged 9-32 years). The combined scapular/parascapular bilobar flaps, pedicled on the circumflex scapular vascular bundle, were microsurgically used to cover the soft tissue defect after excision of hypertrophic scar and release of contracture. The maximum size of the combined bilobar flap was 20 cm×8 cm to 20 cm×11 cm,while the minimum one was 15 cm×4 cm to 15 cm×6 cm. Results The combined scapular/parascapular flapswere successfully used to treat 9 cases of severe neck contracture. All patients were satisfied with the final functional and aesthetic results. There was no recurrence during 3-9 months follow-up for 8 patients. The cervicomental angle was 90-105°.Conclusion The combined bilobar scapular/parscapular flap, providing a large area of tissue for coverage in three dimensions with a reliable blood supply by only one pedicle anastomosis during operation, is agood option for reconstruction of the severe neck contracture.

    Release date:2016-09-01 09:26 Export PDF Favorites Scan
  • CLINICAL APPLICATION OF SCAPULAR FLAP PEDICAL ON LATERAL DESCENDING CUTANEOUS BRANCH OF CIRCUMFLEX SCAPULAR ARTERY

    Objective To introduce a new design of the scapular flap.Methods The lateral descending cutaneous branch of the circumflex scapular artery was investigated in 10 cadavers with radiography. Based on the results, we usedthe scapular flap(from 8 cm×25 cm to 11 cm×35 cm) pedical on the lateral descending cutaneous branch of the circumflex scapular artery to reconstruct defects offaciocervical region after burning in 7 patients, with direct suture the donatearea,or skin grafting.Results Sever flaps survived completely, satisfactoryresults were obtained except 2 patients’ flap to need to be thinned during the following up.Conclusion This flap can be designed to extend to the inframamary fold, the donor-site scar of the flap is well hidden. The design of the flap broadens the application of the scapular flap.

    Release date: Export PDF Favorites Scan
  • SURGICAL TREATMENT OF SUPRASCAPULAR NERVE COMPRESSION SYNDROME THROUGH POSTERIORAPPROACH

    Objective To discuss the optimal approach to treat suprascapular nerve compression syndrome. Methods From January 2000 to June 2003, 8 cases of suprascapular nerve compression syndrome were treated by surgical intervention to cut the transverse scapular ligament through posterior approach. Of the 8 patients, there were 2 males and 6 females (age ranged from 21 to 53) with duration of 6 months to 3 years. The change of symptom, muscle power, and muscle atrophy after operation were observed. Results One week after operation, pain around the scapular disappeared, muscle power of supraspinatus and infraspinatus muscles recovered to normal. One, 6, 12 and 16 months after the operation, the patients were followed up. No recurrence was observed. Muscle atrophy didn’t recover.Conclusion To treat suprascapular nerve compression syndrome with operation through posterior approach is easy to operate. When the suprascapular nerve is entrapped in scapular notch, this approach is a good choice.

    Release date:2016-09-01 09:28 Export PDF Favorites Scan
  • POKING REDUCTION TREATMENT OF DISPLACED SCAPULAR NECK FRACTURE WITH SHOULDER ARTHROSCOPY-ASSISTED SURGERY

    ObjectiveTo discuss the effectiveness of Poking reduction with shoulder arthroscopy-assisted surgery for displaced scapular neck fracture. MethodsBetween January 2009 and January 2012,9 cases of displaced scapular neck fracture underwent shoulder arthroscopy-assisted surgery for Poking reduction treatment.Of 9 cases,6 were men,and 3 were women,aged 21-54 years (mean,39 years).The causes were traffic accident injury in 7 cases,falling injury from height in 1 case,and hurt injury in 1 case.The shoulder abduction,flexion,and external rotation were obviously limited.X-ray films showed all cases had obvious displaced scapular neck fracture.Three-dimensional reconstruction of CT showed a grossly displaced of fracture.The time of injury to surgery was 4-27 days (mean,11 days). ResultsPatients obtained healing of incision by first intension,without infection,neurovascular injury,or other surgery-related complications.All patients were followed up 19-31 months (mean,23 months).X-ray films showed scapular neck fractures healed from 7 to 11 weeks (mean,8 weeks).At last follow-up,the shoulder abduction,flexion,and external rotation activity were improved significantly when compared with ones at preoperation (P<0.05);the shoulder Constant score,American Shoulder and Elbow Surgenos (ASES) score,and Rowe score were significantly better than preoperative scores (P<0.05). ConclusionThe reduction of displaced scapular neck fracture is necessary,and arthroscopic Poking reduction and fixation for displaced scapular neck fracture can reconstruct the shoulder stability and reduce complications

    Release date: Export PDF Favorites Scan
  • Short-term effectiveness of arthroscopic repair via modified subacromial viewing portal in treatment of LafosseⅠ subscapularis tendon tears

    Objective To investigate short-term effectiveness of arthroscopic repair via modified subacromial viewing portal (hereinafter referred to as modified viewing portal) in treatment of LafosseⅠsubscapularis tendon tears. Methods A clinical data of 52 patients with LafosseⅠsubscapularis tendon tears, who underwent the arthroscopic repair via modified viewing portal between October 2020 and November 2022 and met the selective criteria, was retrospectively analyzed. There were 15 males and 37 females with an average age of 63.4 years (range, 41-76 years). Twelve patients had trauma history and the other 40 patients had no obvious inducement. The main clinical symptom was shoulder pain and the hug resistance tests were positive in all patients. The interval between symptom onset and admission ranged from 3 to 26 months (mean, 7.2 months). The shoulder pain and function were evaluated by visual analogue scale (VAS) score, American Shoulder and Elbow Surgeons (ASES) score, and University of California Los Angeles (UCLA) score before operation and at 12 months after operation. The shoulder range of motion (ROM) of forward flexion, abduction, and external rotation and the internal rotation strength were measured before operation and at 3 and 12 months after operation. MRI was performed at 3-6 months after operation to assess the tendon healing and the structural integrity and tension of reattached tendon. Patient’s satisfactions were calculated at last follow-up. Results All incisions healed by first intention, no complication such as incision infection or nerve injury occurred. All patients were followed up 12-37 months (mean, 18.5 months). The VAS, UCLA, and ASES scores at 12 months after operation significantly improved when compared with those before operation (P<0.05). The ROMs of abduction and forward flexion and the internal rotation strength at 3 and 12 months significantly improved when compared with those before operation (P<0.05); and the ROMs at 12 months significantly improved compared to that at 3 months (P<0.05). However, there was no significant difference (P>0.05) in the ROM of external rotation at 3 months compared to that before operation; but the ROM at 12 months significantly improved compared to that before operation and at 3 months after operation (P<0.05). Thirty-one patients underwent MRI at 3-6 months, of which 28 patients possessed intact structural integrity, good tendon tension and tendon healing; 3 patients underwent tendon re-tear. At last follow-up, 41 patients (78.8%) were very satisfied with the effectiveness, 7 were satisfied (13.5%), and 4 were dissatisfied (7.7%). Conclusion Arthroscopic repair via modified viewing portal for Lafosse Ⅰsubscapularis tendon tears, which can achieve the satisfactory visualization and working space, can obtain good short-term effectiveness with low overall re-tear risk.

    Release date:2024-01-12 10:19 Export PDF Favorites Scan
  • Comparative study of posterior axillary edge approach and arthroscopic assisted reduction in treatment of Ideberg type Ⅰ and Ⅱ glenoid fracture of the scapula

    Objective To compare the effectiveness of posterior axillary edge approach and arthroscopic assisted reduction in the treatment of Ideberg type Ⅰ and Ⅱ glenoid fracture of the scapula. Methods The clinical data of 26 patients with fresh Ideberg type Ⅰ and Ⅱ scapular fractures admitted between June 2021 and September 2024 who met the selection criteria were analyzed retrospectively. The patients were divided into two groups according to different treatment methods. Ten cases in the posterior axillary edge group were fixed by open reduction plate through the posterior axillary edge approach, and 16 cases in the arthroscopy group were treated with suture anchor fixation under arthroscopy. There was no significant difference in baseline data between the two groups (P>0.05), such as gender, age, surgical side, Ideberg type, cause of injury, time from injury to operation, rotator cuff injury, and superior labrum anterior posterior (SLAP) injury, etc. The operation time and fracture healing time were recorded and compared between the two groups, and the shoulder pain was evaluated by visual analogue scale (VAS) score at 1 week, 1 month, and 3 months after operation. At 3 and 6 months after operation, the range of motion of shoulder joint in anteflexion, abduction, external rotation, internal rotation, and backward extension was evaluated, the upper limb dysfunction was evaluated by the Disability Assessment Scale of Arm, Shoulder, and Hand (DASH), and the shoulder joint function was evaluated by the Constant-Murley score. The differences between 6 months and 3 months after operation (changes) were statistically analyzed. ResultsPatients in both groups were followed up 11-13 months, with an average of 12.5 months. The operation time and fracture healing time in the posterior axillary edge group were significantly shorter than those in the arthroscopy group (P<0.05). There was no complication such as wound infection, vascular and nerve injury, loss of reduction, bone nonunion, or glenohumeral instability in both groups. At 1 week after operation, the VAS score in the posterior axillary edge group was significantly higher than that in the arthroscopy group (P<0.05); there was no significant difference in the VAS score between the two groups at 1 and 3 months after operation (P>0.05). At 6 months after operation, the changes of shoulder joint in anteflexion, internal rotation range of motion and DASH scores in the posterior axillary edge group were significantly lower than those in the arthroscopy group (P<0.05), while the changes of abduction, external rotation, backward extension range of motion and Constant-Murley scores were not significantly different between the two groups (P>0.05). ConclusionFor Ideberg type Ⅰ and Ⅱ glenoid fracture of the scapula, the posterior axillary edge approach for internal fixation has a short operation time, fast fracture healing, and is beneficial for early functional recovery; arthroscopic assisted reduction has minimal trauma and can handle joint injuries simultaneously. Both surgical procedures are safe and effective, and individualized selection should be made based on soft tissue conditions and combined injuries.

    Release date:2025-05-13 02:15 Export PDF Favorites Scan
  • Development of a risk stratification model for subscapularis tendon tear based on patient-specific data from 528 shoulder arthroscopy

    Objective To identify and screen sensitive predictors associated with subscapularis (SSC) tendon tear and develop a web-based dynamic nomogram to assist clinicians in early identification and intervention of SSC tendon tear. Methods Between July 2016 and December 2021, 528 consecutive cases of patients who underwent shoulder arthroscopic surgery with completely MRI and clinical data were retrospectively analyzed. Patients admitted between July 2016 and July 2019 were included in the training cohort, and patients admitted between August 2019 and December 2021 were included in the validation cohort. According to the diagnosis of arthroscopy, the patients were divided into SSC tear group and non-SSC tear group. Univariate analysis, least absolute shrinkage and selection operator (LASSO) method, and 10-fold cross-validation method were used to screen for reliable predictors highly associated with SSC tendon tear in a training set cohort, and R language was used to build a nomogram model for internal and external validation. The prediction performance of the nomogram was evaluated by concordance index (C-index) and calibration curve with 1 000 Bootstrap. Receiver operating curves were drawn to evaluate the diagnostic performance (sensitivity, specificity, predictive value, likelihood ratio) of the predictive model and MRI (based on direct signs), respectively. Decision curve analysis (DCA) was used to evaluate the clinical implications of predictive models and MRI. Results The nomogram model showed good discrimination in predicting the risk of SSC tendon tear in patients [C-index=0.878; 95%CI (0.839, 0.918)], and the calibration curve showed that the predicted results were basically consistent with the actual results. The research identified 6 predictors highly associated with SSC tendon tears, including coracohumeral distance (oblique sagittal) reduction, effusion sign (Y-plane), subcoracoid effusion sign, biceps long head tendon displacement (dislocation/subluxation), multiple posterosuperior rotator cuff tears (≥2, supra/infraspinatus), and MRI suspected SSC tear (based on direct sign). Compared with MRI diagnosis based on direct signs of SSC tendon tear, the predictive model had superior sensitivity (80.2% vs. 57.0%), positive predictive value (53.9% vs. 53.3%), negative predictive value (92.7% vs. 86.3%), positive likelihood ratio (3.75 vs. 3.66), and negative likelihood ratio (0.25 vs. 0.51). DCA suggested that the predictive model could produce higher clinical benefit when the risk threshold probability was between 3% and 93%. ConclusionThe nomogram model can reliably predict the risk of SSC tendon tear and can be used as an important tool for auxiliary diagnosis.

    Release date:2022-06-29 09:19 Export PDF Favorites Scan
  • Application of three-dimensional printed total scapula for reverse shoulder arthroplasty in treatment of scapular tumors

    ObjectiveTo investigate the effectiveness of three-dimensional (3D) printed total scapula for reverse shoulder arthroplasty in the treatment of scapular tumors. MethodsBetween November 2017 and December 2021, 5 patients with scapular tumors were treated by reverse shoulder arthroplasty with 3D printed total scapula. There was 1 male and 4 females. The age ranged from 44 to 59 years, with an average of 50.4 years. There were 2 cases of chondro sarcoma, 1 case of high-grade osteosarcoma, 1 case of lung cancer with scapular metastasis, and 1 case of ligamentoid fibromatosis recurrence. The disease duration was 4-8 months, with an average of 5.8 months. According to the Musculoskeletal Tumor Society (MSTS) scapular girdle classification criteria, 4 cases of tumors involved both S1 and S2 zones, and 1 case involved S2 zone. The tumor diameters ranged from 4.2 to 11.2 cm, with an average of 6.1 cm. The operation time, intraoperative blood loss, and blood transfusion were recorded. During follow-up, the MSTS score was used to evaluate the recovery of limb function of the patients. The sink depth of the affected shoulder, complications, and oncological outcomes were observed. The position of the prosthesis was reviewed by imaging. ResultsThe operation time ranged from 155 to 230 minutes, with an average of 189 minutes. The intraoperative blood loss was 100-1 500 mL, with a median of 600 mL. Two patients were received blood transfusion of 800 mL and 1 850 mL respectively during operation. All incisions healed by first intention, and no complications such as infection occurred. All patients were followed up 4-22 months, with an average of 13 months. Two patients died at 8 and 15 months after operation respectively due to multiple metastases and organ failure. At last follow-up, the MSTS score of all patients was 73%-83%, with an average of 77.4%. The affected shoulder was 2-4 cm lower than the contralateral side, with an average of 3 cm. Imaging examinations showed that no prosthesis loosening, dislocation, or fracture occurred during follow-up. Conclusion Reverse shoulder arthroplasty with 3D printed total scapula can obtain good shoulder function and appearance. Patients have high acceptance and satisfaction with this surgical method.

    Release date:2022-08-04 04:33 Export PDF Favorites Scan
  • Modified Latarjet splitting subscapularis muscle under arthroscopy: an anatomical study based on axillary nerve, glenoid, and subscapularis muscle

    Objective To testify the spatial relationship between the subscapularis muscle splitting window and the axillary nerve in modified arthroscopic Latarjet procedure, which could provide anatomical basis for the modification of the subscapularis muscle splitting. MethodsA total of 29 adult cadaveric shoulder specimens were dissected layer by layer, and the axillary nerve was finally confirmed to walk on the front surface of the subscapularis muscle. Keeping the shoulder joint in a neutral position, the Kirschner wire was passed through the subscapularis muscle from back to front at the 4 : 00 position of the right glenoid circle (7 : 00 position of the left glenoid circle), and the anterior exit point (point A, the point of splitting subscapularis muscle during Latarjet procedure) was recorded. The vertical and horizontal distances between point A and the axillary nerve were measured respectively. Results In the neutral position of the shoulder joint, the distance between the point A and the axillary nerve was 27.37 (19.80, 34.55) mm in the horizontal plane and 16.67 (12.85, 20.35) mm in the vertical plane. Conclusion In the neutral position of the shoulder joint, the possibility of axillary nerve injury will be relatively reduced when radiofrequency is taken from the 4 : 00 position of the right glenoid (7 : 00 position of the left glenoid circle), passing through the subscapularis muscle posteriorly and anteriorly and splitting outward.

    Release date:2023-05-11 04:44 Export PDF Favorites Scan
  • APPLIED ANATOMY OF BONE FLAP PEDICLED WITH SPINA SCAPULAR BRANCH OF TRANSVERSE CERVICAL ARTERY FOR MANDIBULAR RECONSTRUCTION

    OBJECTIVE To study the anatomical basis of vascularized spina scapular bone flap, which was used in mandibular reconstruction. METHODS Fifteen adult cadavers were adopted in this study. The two common carotid arteries of each cadaver were intubed and perfused with red emulsion respectively. Then the course and distribution of the transverse cervical artery(TCA) and its spina scapular branches were observed on 30 sides. RESULTS The TCA was divided into two segments: the cervical segment originated from the origin of the artery to the superior margin of the trapezius muscle, and the dorsal segment originated from the superior margin of the trapezius muscle to the site where the TCA bifurcated into the superficial and deep branches. The average length and original caliber of the cervical segment were(4.7 +/- 0.1) cm and (4.0 +/- 0.1) mm. The average length and original caliber of the dorsal segment were (5.88 +/- 0.63) cm and (3.30 +/- 0.35) mm. 86.7% spina scapular branches originated from the superficial branch of TCA and 13.3% from TCA. The length of the spina scapular branch was (4.97 +/- 1.68) cm and its external diameter was (2.08 +/- 0.27) mm. It constantly sent 4-8 periosteal branches to spina with 0.20-1.25 mm in caliber. CONCLUSION The spina scapular branch of TCA is one of the main blood supplier to the spina scapular area. The spina scapular flap pedicled with spina scapular branch of TCA may provide a new operation for mandibular reconstruction, whose circumpoint locates at the origin of the dorsal segment and the average length of the pedicle is 10.85 cm which enough to transposite to mandibular area.

    Release date:2016-09-01 11:05 Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content