ObjectiveTo research the procedure for creating an animal model of mitral regurgitation by implanting a device through the apical artificial chordae tendineae, and to assess the stability and dependability of the device. MethodsTwelve large white swines were employed in the experiments. Through a tiny hole in the apex of the heart, the artificial chordae tendineae of the mitral valve was inserted under the guidance of transcardiac ultrasonography. Before, immediately after, and one and three months after surgery, cardiac ultrasonography signs were noted. Results All models were successfully established. During the operation and the follow-up, no swines died. Immediately after surgery, the mitral valve experienced moderate regurgitation. Compared with preoperation, there was a variable increase in the amount of regurgitation and the values of heart diameters at a 3-month follow-up (P<0.05). ConclusionIn off-pump, the technique of pulling the mitral valve leaflets with chordae tendineae implanted transapically under ultrasound guidance can stably and consistently create an animal model of mitral regurgitation.
Objective To investigate the feasibility and early efficacy of transapical transcatheter aortic valve replacement (TAVR) combined with transcatheter mitral valve edge-to-edge repair (TEER) in patients with high-risk aortic valve lesions combined with severe mitral regurgitation. Methods The clinical data of patients who underwent "one-stop" transapical TAVR+TEER in our hospital from August 2022 to October 2023 were retrospectively analyzed. Results Five patients were collected, including 3 males and 2 females with a mean age of 66.6±1.8 years. Four patients had aortic valve insufficiency combined with mitral regurgitation and one had aortic valve stenosis and insufficiency combined with mitral regurgitation. All patients successfully completed transapical TAVR+TEER, and the immediate postoperative echocardiographic results revealed that none of them had more than mild perivalvular leakage and mitral regurgitation, and the prosthetic valves were in good position and function. At 1 week postoperatively, echocardiographic results showed 5 patients with no displacement of the prosthetic valve, detachment of the mitral clip, or damage to the leaflets. At 1 month postoperatively, cardiac function was improved to varying degrees in 4 patients, and 1 patient died of multiorgan failure. At 2 months postoperatively, 1 patient died of cerebrovascular accident, and at 3 months postoperatively the echocardiographic results of the remaining 3 patients revealed that there was no more than mild perivalvular leakage or mitral regurgitation, and the patients' postoperative cardiac function and daily life ability were significantly improved. Conclusion In high-risk aortic valve lesions combined with severe mitral regurgitation, "one-stop" transapical TAVR+TEER is feasible with favorable early efficacy and safety.
ObjectiveTo evaluate the safety and efficacy of transapical mitral valve repair with moderate-to-severe or severe mitral regurgitation (MR) by using LifeClip system. Methods We retrospectively analyzed the clinical data of 7 symptomatic patients with moderate-to-severe or severe MR who received transapical mitral valve repair by using the LifeClip system in our hospital from July to November 2021. There were 5 males and 2 females with an average age of 76.0±7.5 years. ResultsThere were 2 patients with degenerative MR and 5 patients with functional MR. All of the procedures were successful and 6 patients received 1 LifeClip while the other one patient received 2. The operation time was 135.7±46.9 min, the mechanical ventilation time was 12 (3, 14) h, and the hospital stay time was 18.1±4.1 d. No serious complications or death occurred during the perioperative or follow-up period. MR reduction by ≥2 grades was achieved in all the patients at the one-month follow-up. The classification of cardiac function was improved in varying degrees. Conclusion Transapical mitral valve repair using the LifeClip system shows good safety and efficacy for severe MR patients, and MR degree is significantly improved at early follow-up. However, the benefit of LifeClip should be validated in a larger sample size of Chinese population and through long-term follow-up.
ObjectiveTo compare the in-hospital outcomes of transapical transcatheter aortic valve replacement (TA-TAVR) for bicuspid aortic valve (BAV) patients and tricuspid aortic valve (TAV) patients. MethodsPatients (including BAV and TAV patients) who underwent TA-TAVR with the J-ValveTM in West China Hospital from July 2014 to July 2020 were included consecutively. The clinical outcomes of the patients were analyzed. ResultsA total of 354 patients were included in the study, 75 in the BAV group and 279 in the TAV group. There were 229 males and 125 females with a mean age of 72.2±6.0 years. No death occurred during the procedure, and the overall technical success rate was 97.7%. The all-cause in-hospital mortality rate was 1.4%. Twenty (26.7%) patients with BAV and 46 (16.5%) patients with TAV had mild or higher perivalvular leaks immediately after the procedure. No patients with BAV required permanent pacemaker implantation postoperatively, while 13 (4.7%) TAV patients required permanent pacemaker implantation, with an overall pacemaker implantation rate of 3.7%. One (1.3%) BAV patient and 7 (2.5%) TAV patients developed acute kidney injury postoperatively. One (1.3%) BAV patient and 1 (0.4%) TAV patient developed perioperative myocardial infarction. The average postoperative hospital stay was 7.6±3.6 d for BAV patients and 8.6±6.1 d for TAV patients. There was no statistical difference in primary or secondary in-hospital outcomes between BAV and TAV patients (P>0.05). ConclusionCompared to TAV patients, BAV patients have similar in-hospital outcomes, with a low incidence of adverse clinical outcomes, which provides preliminary evidence for its implementation in Chinese patients with a high proportion of BAV.
The technique of transcatheter aortic valve implantation has become increasingly mature. Although the transapical approach has a certain degree of minimally invasive trauma, it still has the characteristics such as heart beating without cardiopulmonary bypass, and the low technical requirements of catheter guide wire. In particular, the valve path is short and coaxial, which is easy to manipulate, and pure regurgitation and stenosis can be easily operated and are not subject to the limit of peripheral artery stenosis. It is still one of China's main approaches for transcatheter aortic valve replacement. Its perioperative management still has specific features and differs from the femoral artery approach. In addition, there is little relevant literature abroad. Therefore, domestic experts in this field were organized to discuss the development of perioperative management specifications to provide reference and techniques support for developing this field in China and further improve the quality of clinical operation and perioperative management. It will provide more safe and more effective medical services to these patients.
Patients with Takayasu arteritis combined with aortic valve disease often have a poor prognosis following surgical valve replacement, frequently encountering complications such as perivalvular leakage, valve detachment, and anastomotic aneurysm. This article presents a high-risk case wherein severe aortic valve insufficiency associated with Takayasu arteritis was successfully managed through transcatheter aortic valve implantation via the transapical approach. The patient had satisfactory valve function with no complications observed during the six-month postoperative follow-up period. This case provides a minimally invasive and feasible alternative for the clinical management of such high-risk patients.
Transcatheter aortic valve replacement (TAVR) techniques have been rapidly developed in recent years. Current guidelines and studies mainly focus on aortic stenosis patients treated by transfemoral approach, but they are not completely appropriate to patients with isolated aortic regurgitation or other patients who need transapical TAVR (TA-TAVR), which affects the standardized treatment of those patients. Therefore, our team pronounced the operational standards for TA-TAVR, based on fully reviewing the literatures worldwide, combined with the opinions of experts from 15 heart centers with rich experience in carrying out TA-TAVR in China. This standard aims to provide clinicians with standardized diagnosis and treatment principles of TA-TAVR and improve the quality of TA-TAVR in China.
ObjectiveTo evaluate the early and mid-term safety of transcatheter aortic valve replacement via transfemoral (TF), transapical (TAp) and transsubclavian (TSc) approaches by meta-analysis.MethodsWe systematically searched the clinical comparative trials published from inception to June 2019 from PubMed, Web of Science, EMbase and The Cochrane Library, to evaluate the safety of transcatheter aortic valve replacement through TF, TAp or TSc approaches. The information of all-cause mortality at 30 days, 1 year, 2 years and the incidence of common complications at 30 days after operation (including pacemaker-dependent block, major vascular complications, severe bleeding events, acute renal injury and stroke) were exacted, and a meta-analysis was conducted by RevMan 5.3 software.ResultsThis study included 11 literatures, with a total of 7 833 patients, among whom 5 348 patients were treated by TF TAVR, 1 796 patients by TAp TAVR and 689 patients by TSc TAVR. The results of the meta-analysis were as follows: (1) at 30 days after operation, the mortality of TF and TSc approaches were lower than that of the TAp approach (TF vs. TAp: OR=0.57, 95%CI 0.39-0.84, P=0.004; TSc vs. TAp: OR=4.12, 95%CI 1.93-8.79, P=0.000 3). There was no statistical difference between the TF and TSc approaches (TF vs. TSc: OR=0.98, 95%CI 0.38-2.51, P=0.97); at 1 year, there was no statistical difference in mortality among the three approaches (P>0.05); at 2 years, there was no statistical difference between TSc and TF or TAp approaches (TF vs. TSc: OR=1.21, 95%CI 0.95-1.54, P=0.13; TSc vs. TAp: OR=1.02, 95%CI 0.76-1.36, P=0.91). (2) The incidence of acute kidney injury after TF approach was lower than that of the TAp approach (OR=0.30, 95%CI 0.22-0.41, P<0.000 01). (3) There was no statistical difference in major vascular complications between TSc and TF or TAp approaches (TF vs. TSc: OR=0.75, 95%CI 0.38-1.49, P=0.41; TSc vs. TAp: OR=1.37, 95%CI 0.56-3.32, P=0.49). (4) There was no statistical difference in severe bleeding events between TF and TSc (OR=0.97, 95%CI 0.53-1.76, P=0.92). (5) There was no statistical difference in the incidence of postoperative stroke, pacemaker dependent block among the three approaches (P>0.05).ConclusionTAp and TSc approaches are safe and effective. They are not only an alternative to TF approach, but also the first choice in some patients with poor condition of iliofemoral artery.
According to the needs of CT image evaluation for transapical transcatheter aortic valve replacement (TAVR), 20 clinical questions were proposed by the Delphi method, 15 questions were initially determined, and 12 clinical questions were summarized and determined by domestic experts. PubMed, Web of Science, Wanfang, and CNKI databases were searched by computer to collect the relevant literature from inception to November 2022, and finally 53 studies were included. Based on evidence-based study and evaluation experience, 3 meetings were held to give recommendations for preoperative CT data acquisition method, preoperative imaging evaluation of aortic root, imaging evaluation of transapical approach, preoperative auxiliary guidance of TAVR by CT images combined with 3D printing, and postoperative imaging evaluation of transapical TAVR, hoping to promote the standardized and successful development of transapical TAVR in China.
Transcatheter aortic valve replacement (TAVR) has become the preferred treatment for severe aortic stenosis. The localization and anchor of many transcatheter heart valves available in the clinic today are dependent on the calcific aortic valve leaflet of patients. We reported here a successful case of transapical aortic valve implantation with Ken-Valve heart valve in an 82-year-old male patient with pure severe aortic regurgitation without native valve calcium. Postoperative follow-up (3 months after the surgery) showed that the cardiac function significantly improved. The echocardiography indicated that the Ken-Valve prosthesis worked well without perivalvular regurgitation. The short-term clinical effect was satisfactory. The Ken-Valve with three position anchors is proved to be suitable for the treatment of pure aortic regurgitation.