west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "transcatheter" 108 results
  • A case of transcatheter aortic valve replacement with right-&-left coronary protection

    Transcatheter aortic valve replacement (TAVR) has become a common theraputic option for aortic stenosis, but the evidence for precise anatomy for TAVR is accumulating. This paper presents the case of an 71-year-old female patient who had an extremely high risk of coronary obstruction due to both coronary ostia lying too low. The patient underwent TAVR with the help of coronary protection successfully. During the procedure, the patient was protected with wires only for both coronaries. After deployment, angiofluoroscopy suggested that chimney stenting should be applied for left coronary. The whole procedure was unenventful and both coronaries were seen.

    Release date:2022-05-24 03:47 Export PDF Favorites Scan
  • Research advance of surgical transcatheter mitral valve repair

    Mitral regurgitation (MR) with multi-pathogenesis is a common disease in cardiac surgery department. MR can be classified into two categories-primary mitral regurgitation and secondary mitral regurgitation. With the development of cardiac intervention, numerous patients who cannot tolerate open heart surgery for the reason of high risk of surgery receive the treatment of intervention and achieve the favorable endpoint. The technique of transcatheter therapy which could be used to treat MR is comprised of leaflet repair, annuloplasty and implantation of artificial chordae. Comparing to primary mitral regurgitation, surgical effect of secondary mitral regurgitation is not desirable for the reasons of complex pathophysiologic mechanism. Hence, based on the perspective of surgeon, we will introduce the research progress of transcatheter interventional mitral valve repair which is focused on the treatment of primary mitral valve regurgitation and reviewed from three aspects of surgical risks, surgical types and outlook.

    Release date:2019-06-18 10:20 Export PDF Favorites Scan
  • Simultaneous TAVI and McKeown for esophageal cancer with severe aortic regurgitation: A case report

    A 71-year-old male presented with esophageal cancer and severe aortic valve regurgitation. Treatment strategies for such patients are controversial. Considering the risks of cardiopulmonary bypass and potential esophageal cancer metastasis, we successfully performed transcatheter aortic valve implantation and minimally invasive three-incision thoracolaparoscopy combined with radical resection of esophageal cancer (McKeown) simultaneously in the elderly patient who did not require neoadjuvant treatment. This dual minimally invasive procedure took 6 hours and the patient recovered smoothly without any surgical complications.

    Release date:2025-01-21 11:07 Export PDF Favorites Scan
  • Transcatheter valve-in-valve implantation using the J-Valve for bioprosthetic degeneration at different anatomic positions: A single-center experience

    Objective To summarize the early results and clinical experience of using the J-Valve for transcatheter valve-in-valve implantation in patients with degenerated bioprosthesis at different anatomic positions. Methods A retrospective analysis was conducted to evaluate the short-term outcomes of 39 consecutive patients who underwent transcatheter valve-in-valve implantation using the J-Valve System in the Department of Cardiac Surgery of Guangdong Provincial People’s Hospital from April 2020 to August 2021 due to bioprosthetic degeneration at different anatomic positions. Among them, 35 patients underwent transcatheter mitral valve-in-valve (TMViV) implantation, 1 transcatheter aortic valve-in-valve (TAViV) implantation, 1 transcatheter tricuspid valve-in-valve (TTViV) implantation, 1 TMViV implantation with simultaneous TAViV implantation, and another one TMViV implantation with simultaneous transcatheter aortic valve replacement (TAVR) and perivalvular leakage (PVL) closure. Results Among the 35 patients who underwent isolated TMViV implantation, 17 were male and 18 were female with a mean age of 72.6±10.8 years. Mean duration between two operations was 10.5±2.7 years. The mean Society of Thoracic Surgeons and EuroSCORE Ⅱ scores were 12.95%±9.61% and 13.91%±8.94%, respectively. The device success rate was 97.1% and no death occured during the operation. One patient was transferred to thoracotomy due to device displacement, 1 was re-opened for uncontrolled bleeding, and 1 presented left ventricular outflow tract obstruction. One patient underwent craniotomy due to intracranial hemorrhage within 30 days after surgery, and no other complications occurred including death, stroke, permanent pacemaker implantation, cardiac tamponade, or re-hospitalization. The mean follow-up time was 6.0±4.4 months, the mean mitral valve gradient was significantly improved (10.4±2.0 mm Hg vs. 5.5±1.2 mm Hg, P<0.05), and the New York Heart Association class≤Ⅱ in all the patients at the last follow-up. Among the other 4 patients who did not undergo isolated TMViV implantation, the transapical TAViV implantation and the trans-right atrium TTViV implantation were successful without intra- or post-operative complications. The patient who underwent TMViV and TAViV implantation simultaneously via transapical approach died of severe pulmonary hemorrhage and multiple organ failure 16 days after surgery. The other patient who underwent transapical TMViV combined with TAVR and PVL closure died of septic shock 10 days after the surgery. Conclusion Transcatheter valve-in-valve implantation using the J-Valve system is shown to be a safe and effective procedure to treat mitral, aortic and tricuspid bioprosthetic valve dysfunction in high-risk patients, providing a new alternative to surgical surgery for degenerated bioprosthesis at different anatomic positions. However, simultaneous different valves intervention should be very cautious.

    Release date:2022-11-22 02:01 Export PDF Favorites Scan
  • Short-term results of valve-in-valve transcatheter aortic valve implantation in patients with degenerated bioprosthesis

    Objective To summarize the short-term results of valve-in-valve transcatheter aortic valve implantation (ViV-TAVI) in the treatment of bioprosthetic valve failure after aortic valve replacement. Methods We reviewed the clinical data of patients who underwent ViV-TAVI from 2021 to 2022 in the First Affiliated Hospital of Zhengzhou University. The valve function was evaluated by echocardiography before operation, immediately after operation and 3 months after operation. The all-cause death and main complications during hospitalization were analyzed. Results A total of 13 patients were enrolled, including 8 males and 5 females with a mean age of (65.9±8.5) years, and the interval time between aortic valve replacement and ViV-TAVI was (8.5±3.4) years. The Society of Thoracic Surgeons mortality risk score was 10.3%±3.2%. None of the 13 patients had abnormal valve function after operation. The mean transvalvular pressure gradient of aortic valve was decreased (P<0.001), the peak flow velocity of aortic valve was decreased (P<0.001), and the left ventricular ejection fraction was not changed significantly (P=0.480). There were slight perivalvular leakage in 2 patients and slight valve regurgitation in 3 patients. Three months after operation, the mean transvalvular pressure difference and peak flow velocity of aortic valve in 12 patients were significantly decreased compared with those before operation (P≤0.001). Conclusion This study demonstrates that ViV-TAVI for the treatment of bioprosthetic valve failure after aortic valve replacement is associated with favorable clinical and functional cardiovascular benefits, the short-term results are satisfactory.

    Release date:2025-06-24 11:15 Export PDF Favorites Scan
  • Comparison of 1-year clinical results of transcatheter aortic valve replacement (TAVR) using prostheses with two different frame designs in 124 patients in a single center

    ObjectiveTo compare and analyze the clinical effects of two kinds of frame design valves after transcatheter aortic valve replacement (TAVR).MethodsWe retrospectively reviewed 124 patients who underwent TAVR and were followed up for 1 year. There were 71 males and 53 females aged 75.57±6.21 years. These patients were treated with Venus-A or Edwards Sapien aortic valves. The hemodynamics and cardiac function of these two kinds of transcatheter aortic valves (THV) were evaluated by echocardiography. The 30-day mortality and 1-year clinical effect of the patients were calculated.ResultsEight-one patients used Venus-A valve and 43 patients used Edwards Sapien valve. The aortic valve transaortic pressure gradient was reduced and the rate of perivalvular leakage was low (both 2.6%) in both groups, and there was no statistical difference between the two groups. The implantation rate of permanent pacemaker was 17.3% and 11.6%, respectively. The 1-month survival (94.0% and 93.0%) and 1-year survival (94.0% and 91.0%) rates were not statistically different.ConclusionThe two groups of THV with different stent structures have good short-term clinical effect and low implantation rate of permanent pacemaker.

    Release date:2021-07-28 10:22 Export PDF Favorites Scan
  • Transapical transcatheter aortic valve replacement using Ken-Valve for severe aortic stenosis combined with severe aortic regurgitation: A case report

    Transcatheter aortic valve replacement (TAVR) for severe aortic stenosis is growing rapidly. The use of new heart valves prosthesis has improved surgical safety and efficacy. This report described a 72-year-old male patient with severe aortic stenosis combined with severe aortic regurgitation, who was evaluated at moderate-high risk of surgery and received a transapical TAVR using the Ken-Valve heart valve. The transcatheter operation time was 8 min, and the blood loss was 50 mL. The tracheal intubation was removed immediately after the surgery. Transesophageal echocardiography on the 4th postoperative day showed that the aortic valve leaflets worked well, and there was no valve orifice and paravalvular leakage. The patient was discharged on the 5th day after the surgery without complications. Transapical TAVR using Ken-Valve was an easy surgical procedure for aortic valve disease, and had short operation time.

    Release date:2022-05-23 10:52 Export PDF Favorites Scan
  • Echocardiography-guided transseptal mitral valve replacement: a case report

    In recent years, transcatheter mitral valve replacement is a focused issue in the field of valve intervention, which brings hope to mitral regurgitation patients who are not suitable for surgical thoracotomy. This paper presents the case of echocardiography-guided transseptal mitral valve replacement with the HighLife system in an elderly female patient with severe mitral regurgitation who failed to respond to standard medical therapy. During the procedure, echocardiography was used to guide the wire looping, cinching, atrial septal puncture, ring closure, atrial septal balloon dilatation, prosthetic valve implantation and immediate postoperative evaluation. Echocardiography plays an important role in transseptal mitral valve replacement, which can help the procedural process and improve the safety of the procedure.

    Release date:2024-10-25 01:48 Export PDF Favorites Scan
  • Transapical transcatheter aortic valve replacement for aortic regurgitation in a patient with extremely horizontal aorta

    An 81-year-old male patient was admitted to Guangdong Provincial People's Hospital due to chest distress and shortness of breath after activity for half a year. Examination after admission revealed severe aortic insufficiency, tricuspid aortic valve and extremely horizontal aorta with an aortic root angulation of 99°. The Society of Thoracic Surgeons score was 7%. And taking the strong demand of the patient and his family into consideration, we decided to perform transapical transcatheter aortic valve replacement after multidisciplinary evaluation. The procedure was successfully performed by means of low deployment land zone and traction of pre-exist Prolene suture. Three-month follow-up confirmed the normal function of aortic prosthetic valve without residual regurgitation. This case provides a reference for the interventional treatment in patients with extremely horizontal aorta.

    Release date:2022-05-23 10:52 Export PDF Favorites Scan
  • Establishment of tricuspid regurgitation via right anterior-lateral minimal incision in goats model

    ObjectiveTo explore the feasibility of goat tricuspid regurgitation (TR) model by one chordae tendineae cutter via right anterior-lateral minimal incision.MethodsTR model was established in 6 goats with a self-made tricuspid valve chordae tendineae cutter. The goats were placed in a left lateral position and procedure was performed via a right anterior-lateral minimal thoracotomy in the fourth intercostal. Under the guidance of transesophageal ultrasound and digital subtraction angiography, the chordae tendineae of anterior leaflet was cut until moderate to severe regurgitation was confirmed. Echocardiography and laboratory examinations were performed preoperatively, immediately and 3 months after surgery. Additionally, all goats were sacrificed to clarify pathological evaluation.ResultsTR was successfully established in 6 goats. The right atrium pressure increased significantly immediately after surgery (P<0.05). During a follow-up of 3 months, the progression of TR was aggravated (P<0.05), and the annular diameter increased from 2.15±0.23 cm to 2.65±0.20 cm. Overall, there was no statistically significant change in transvalvular gradient and velocity between preoperation and postoperation. Laboratory test results showed no abnormalities between preoperation and postoperation. Autopsy evaluation demonstrated obvioue chordae tendineae transection of the anterior leaflet.ConclusionIt is feasible to establish TR model via a right minimal anterior lateral thoracotomy in the fourth intercostal space. This novel TR goats model will allow investigation of transcatheter interventional device and serve as a chronic model in the future.

    Release date:2019-10-12 01:36 Export PDF Favorites Scan