west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "valve replacement" 312 results
  • Development of transcatheter heart valve therapy in the world in 2020

    In 2020, due to the impact of the novel coronavirus epidemic, the development of transcatheter heart valve therapy has been shown to slow down, but there are still many aspects worth noting. The indication of monoclonal antibody after transcatheter aortic valve replacement (TAVR) should be further clarified. Low surgical risk patients were included in TAVR relative indications. Mitraclip G4 was approved by CE. The indication of atrial septal occlusion after mitraclip should be further clarified. The technique of coaptation augmentation is expected to become a new method of mitral valve interventional repair. Tendyne transcatheter mitral valve was approved by European Union. Transcatheter tricuspid valve treatment equipments, TriClip and PASCAL obtained CE mark. TAVR technology is being popularized rapidly in China, and what’s more, balloon dilated valve Sapien 3 and new recyclable repositioning valve system-Venus plus have entered the domestic market. A number of mitral valve therapeutic instruments have appeared one after another, and China's first tricuspid valve lux has completed its FIM research. Finally, with the improvement of devices and technology in the future, interventional therapy of heart valve is expected to benefit more patients.

    Release date:2021-04-25 09:57 Export PDF Favorites Scan
  • The Affecting Factors on Sinus Rhythms Maintenance after Electric Cardioversion for Atrial Fibrillation in Patients after Cardiac Valve Replacement

    Objective To explore the affecting factors on sinus rhythm maintenance after electric cardioversion for patients with atrial fibrillation (Af) after cardiac valve replacement. Methods One hundred fifty two valvular disease patients with Af after cardiac valve replacement were randomized to 2 groups: Amiodarone group and control group (without anti arrhythmic drugs) after cardioversion. Af recurrence was observed during one year follow up. Results (1) No significant difference of Af recurrence betwe...

    Release date:2016-08-30 06:35 Export PDF Favorites Scan
  • Predictive factors of new-onset conduction abnormalities after transcatheter aortic valve replacement in patients with bicuspid aortic valve: a meta-analysis

    ObjectiveTo systematically review the predictive factors of new-onset conduction abnormalities(NOCAs) after transcatheter aortic valve replacement (TAVR) in bicuspid aortic valve (BAV) patients. MethodsThe CNKI, VIP, WanFang Data, PubMed, Cochrane Library and EMbase databases were electronically searched to collect the relevant studies on NOCAs after TAVR in patients with BAV from inception to December 5, 2022. Two researchers independently screened the literature, extracted data, and assessed the risk of bias of the included studies. Meta-analysis was then performed by using RevMan 5.4 software. ResultsSix studies involving 758 patients with BAV were included. The results of the meta-analysis showed that age (MD=−1.48, 95%CI −2.73 to −0.23, P=0.02), chronic kidney disease (OR=0.14, 95%CI 0.06 to 0.34, P<0.01), preoperative left bundle branch block (LBBB) (OR=2.84, 95%CI 1.11 to 7.23, P=0.03), membranous septum length (MSL) (MD=0.93, 95%CI 0.05 to 1.80, P=0.04), implantation depth (ID) (MD=−2.06, 95%CI −2.96 to −1.16, P<0.01), the difference between MSL and ID (MD=3.05, 95%CI 1.92 to 4.18, P<0.01), and ID>MSL (OR=0.27, 95%CI 0.15 to 0.49, P<0.01) could be used as predictors of NOCAs. ConclusionCurrent evidence shows that age, chronic kidney disease, LBBB, MS, ID, the difference between MSL and ID, and ID>MSL could be used as predictors of NOCAs. Due to the limited quantity and quality of included studies, more high-quality studies are required to verify the above conclusion.

    Release date:2023-06-20 01:48 Export PDF Favorites Scan
  • Research status of commissural alignment between biological valve and autologous valve in transcatheter aortic valve replacement

    Commissural misalignment of biological valve and autologous valve during transcatheter aortic valve replacement may affect the filling of coronary artery, reduce the feasibility of redo-aortic valve intervention and damage the valve function, which will adversely affect long-term prognosis of patients. Some studies have obtained achievement by changing the axial direction of valve and using individualized computer simulation technology to improve the alignment technology. However, there are still many unknown problems about the impact of commissural misalignment on patients, and accurate commissural alignment techniques still need to be further explored. This article systematically expounds the possible impact of commissural misalignment between biological valve and autologous valve in transcatheter aortic valve replacement, possibly effective accurate commissural alignment techniques and related research progress.

    Release date:2022-05-24 03:47 Export PDF Favorites Scan
  • Clinical research status and progress of redo-transcatheter aortic valve replacement for structural biovalvular degeneration

    Biological valves can lead to structural valve degeneration (SVD) over time and due to various factors, reducing their durability. SVD patients need to undergo valve replacement surgery again, while traditional open chest surgery can cause significant trauma and patients often give up treatment due to intolerance. Research has shown that as an alternative treatment option for reoperation of thoracic valve replacement surgery, redo-transcatheter aortic valve replacement for SVD is safe and effective, but still faces many challenges, including prosthesis-patient mismatch, high cross valve pressure difference, and coronary obstruction. This article aims to review the strategies, clinical research status and progress of redo-transcatheter aortic valve replacement in SVD patients.

    Release date:2024-02-29 12:02 Export PDF Favorites Scan
  • Research progress of transcatheter aortic valve replacement-related new valve prostheses

    Transcatheter aortic valve replacement has revolutionized the management of aortic stenosis and become the gold standard for the treatment of symptomatic and severe aortic valve stenosis in elderly patients. With the improvement in design and materials, newer generation transcatheter aortic valve prostheses had overcome the limitations of early-generation devices that were susceptible to paravalvular leak, atrioventricular block and vascular complications, to a certain extent. This review provides an update on the latest advances in transcatheter aortic valve prostheses.

    Release date:2023-09-28 02:17 Export PDF Favorites Scan
  • Emergent transcatheter aortic valve replacement under ultrasound guidance without CT angiography analysis: a case report

    An elderly female patient, with systemic multiple organ dysfunction, suffered from severe aortic valve stenosis, was to undergo transcatheter aortic valve replacement (TAVR). She was intolerance of the computed tomography examination before surgery. Bedside echocardiography was employed to evaluate the patient’s aortic valve stenosis, valve anatomy and type, the condition of aortic root, the distance from coronary to aortic root, and lower-extremity vascular access. Finally, the emergent TAVR was successfully performed under general anesthesia, and the aortic valve trans-prosthetic gradient met a remarkable decrease after surgery.

    Release date:2020-10-26 03:00 Export PDF Favorites Scan
  • Effect of early postoperative enteral nutrition support on the levels of free amino acids in plasma for patients with cardiac valve replacement

    Objective To investigate the effect of early postoperative enteral nutrition support on the balance of free amino acid spectrum in plasma for patients with cardiac valve replacement during perioperative period. Methods (Forty-seven) patients undergoing cardiac valve replacement were divided into two groups randomly, the routine diet group and the Nutrison Fibre group. The levels of free amino acids in plasma were measured with pre-column derivatization of high-performance liquid chromatography. Results During perioperative period most free amino acids in plasma decreased significantly in the routine diet group (Plt;0.05). Despite some free amino acids in plasma decreased significantly in the Nutrison Fibre group(Plt;0.05), all free amino acids in plasma returned to (Pgt;05) or were higher than the preoperative levels in the postoperative sixth day (Plt;0.05). At the same postoperative points, most free amino acids in plasma in the Nutrison Fibre group were higher than that of the routine diet group (Plt;0.05). Conclusions The levels of free amino acids in plasma decrease significantly in patients with cardiac valve replacement after operation. Early postoperative Nutrison Fibre enteral nutrition support is helpful for keeping the balance of free amino acids in plasma for patients with cardiac valve replacement.

    Release date:2016-08-30 06:28 Export PDF Favorites Scan
  • Preliminary analysis of subclinical leaflet thrombosis after percutaneous aortic valve replacement with balloon dilation

    ObjectiveTo analyze the factors influencing the occurrence of subclinical leaflet thrombosis (SLT) after percutaneous aortic valve replacement using balloon-expandable valve (Sapien3, S3). Methods Retrospective analysis was made on 62 patients with severe aortic stenosis undergoing percutaneous aortic valve replacement using S3 in our center from September 2020 to June 2022. Patients with a history of vascular atherosclerosis or with significant increase or insignificant decrease of aortic valve flow or gradient pressure during follow-up were selected for CT examination. Results A total of 26 patients were finally included, with an average age of 70.31±8.90 years, and the male proportion was higher (n=15, 57.69%). Among them, 5 patients had SLT. Compared with the non-SLT group, patients in the SLT group were older (68.52±8.80 years vs. 77.80±4.66 years, P=0.007). The age factor (≥75 years) and the diameter of the ascending aorta were associated with SLT (both P<0.05). Conclusion The incidence of SLT is higher in the elderly patients. It is speculated that SLT is related to the characteristics of short balloon dilation valves and low blood flow dynamics of valve racks.

    Release date:2023-03-01 04:15 Export PDF Favorites Scan
  • The analysis of mitral valve replacement on the old

    Objective To study effects of mitral valve replacement(MVR) on the old with mitral valve diseases(MVD). Methods The documents of 265 cases undergoing MVR were reviewed, who aged 60 years old or over between June 1991 and June 2003. Demographices, clinical preoperative conditions, indications to surgery, early postoperative course and long-term outcome were collected via hospital documents and outpatient follow-up. Many risk factors were analysed. Results Follow-up rate amounted to 93.7%(236/252). The mortality was 4.9% (13/265) within 30 days. Heart failure and renal failure were the main cause of death. Compared with younger patients(lt;60 years old), long-term survival rate was lower in the old, 5-year 87.52% vs 96.84%, 10-year 81.23% vs 94.87%. There were 15 late deaths(0.17% case/M), most of whom died of heart failure, cancers and lung infections. Risk factors for MVR in the old included New York Heart Association class Ⅳ, diabetes, and lung incompetence. Conclusions The patients with MVD over 60 years old tended to present high postoperatively mortality and morbidity.

    Release date:2016-08-30 06:28 Export PDF Favorites Scan
32 pages Previous 1 2 3 ... 32 Next

Format

Content